This document is a set of vendor questions and customer responses related to a federal solicitation for a Load Cell Monitoring Device. The key details are:
The solicitation number is 80NSSC24879786Q for a requirement at the NASA Armstrong Flight Research Center. The government is seeking a Load Cell Indicator Straight point Wireless Link with two compatible 2" Shackles with a 120,000 lbs. / 55t capacity. This is a Brand Name or Equal To requirement that is set aside for small businesses. The vendor questions cover details such as the crane's serial number, the existing inoperative Load Moment Indicator (LMI) model, and requesting pricing for both a standard Straightpoint RLP55T dynamometer and an ATEX-approved version. The government responses provide the requested information. This procurement has a Net 30 FOB Destination delivery requirement.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SATPC0036237 Tab 10 Vendor Question and Customer Response.pdf | ||
| SATPC0036237 Tab 10 1 RFQ Open Market.pdf | ||
| SATPC0036237 Tab 04 4 SOW_Redacted.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Vendor Question and Answers – Load Moment Indicator
80NSSC24879786Q
Vendor Question Blue/Customer Response Red
Questions:
1. The factory is asking for a crane serial number? The crane’s serial number is 36431.
2. I see you are after an 8K Load Cell for a Broderson attached. What LMI system is on this Crane now? The current inoperative LMI has no serial number, but its model number is LSI GS 550.
3. Please advise, for I am preparing a quote for the Straightpoint RLP55T dynamometer with shackles for NASA. The RLP55T (item 1) is the standard product from Straightpoint and NOT ATEX approved. If you definitely need the item to be ATEX approved I can quote it that way as well. Please quote for the LMI, both as none & ATEX-approved