UNITED STATES DEPARTMENT OF TRANSPORTATION,
EISENHOWER AND SNELL LOCKS
SHIP ARRESTOR HYDRAULIC POWER UNITS
SAINT LAWRENCE SEAWAY DEVELOPMENT CORPORATION
AND BOOM/PIN CYLINDER UPGRADES
MASSENA, NEW YORK
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text
SLSDC
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text U
0.4320
TAO
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text
SLSDC
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
COORDINATED:
AutoCAD SHX Text
RECOMMENDED:
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
OFFICE OF ENGINEERING AND MAINTENANCE
AutoCAD SHX Text
MASSENA, NEW YORK
AutoCAD SHX Text
DEVELOPMENT CORPORATION
AutoCAD SHX Text
SAINT LAWRENCE SEAWAY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES
AutoCAD SHX Text
OF
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
SLS-370-246/1
AutoCAD SHX Text 11/01/19
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ANDREWS ST.
AutoCAD SHX Text
%%UST. LAWRENCE SEAWAY
AutoCAD SHX Text
%%UADMINISTRATION BUILDING
AutoCAD SHX Text
%%U180 ANDREWS STREET
AutoCAD SHX Text
BAY
AutoCAD SHX Text
WATERTOWN
AutoCAD SHX Text
ALEX.
AutoCAD SHX Text
LAKE ONTARIO
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ONTARIO
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
NEW YORK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CARTHAGE
AutoCAD SHX Text
AutoCAD SHX Text
WADDINGTON
AutoCAD SHX Text
GOUVERNEUR
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
OGDENSBURG
AutoCAD SHX Text
MORRISTOWN
AutoCAD SHX Text
ST. LAWRENCE RIVER
AutoCAD SHX Text
CANTON
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TUPPER LAKE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
POTSDAM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MALONE
AutoCAD SHX Text
VT.
AutoCAD SHX Text
AutoCAD SHX Text
LAKE CHAMPLAIN
AutoCAD SHX Text
AutoCAD SHX Text
PLATTSBURGH
AutoCAD SHX Text
AutoCAD SHX Text
QUEBEC
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
AutoCAD SHX Text
MASSENA
AutoCAD SHX Text
AutoCAD SHX Text
CORNWALL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ROUSES PT.
AutoCAD SHX Text
TO US/CANADA BRIDGE
AutoCAD SHX Text
%%UST. LAWRENCE SEAWAY
AutoCAD SHX Text
%%UMARINE BASE/
AutoCAD SHX Text
%%UMAINTENANCE FACILITY
AutoCAD SHX Text
MASSENA CENTER ROAD
AutoCAD SHX Text
DONAHUE ROAD
AutoCAD SHX Text
MAIN STREET
AutoCAD SHX Text
RAQUETTE RIVER ROAD
AutoCAD SHX Text
MASSENA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RR TRACKS
AutoCAD SHX Text
EAST ORVIS ST.
AutoCAD SHX Text
MASSENA
AutoCAD SHX Text
AIRPORT
AutoCAD SHX Text
ALCOA
AutoCAD SHX Text
AutoCAD SHX Text
HORTON ROAD
AutoCAD SHX Text
ST. LAWRENCE
AutoCAD SHX Text
CENTRE MALL
AutoCAD SHX Text
DENNISON ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%UEISENHOWER
AutoCAD SHX Text
%%ULOCK
AutoCAD SHX Text
RAQUETTE RIVER ROAD
AutoCAD SHX Text
O'NEIL ROAD
AutoCAD SHX Text
RAQUETTE RIVER
AutoCAD SHX Text
FREGOE ROAD
AutoCAD SHX Text
SO. GRASS RIVER RD.
AutoCAD SHX Text
GRASS RIVER
AutoCAD SHX Text
KINNIE ROAD
AutoCAD SHX Text
AutoCAD SHX Text
ST. LAWRENCE RIVER
AutoCAD SHX Text
TO NYPA
AutoCAD SHX Text
POWER
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
%%USNELL
AutoCAD SHX Text
%%ULOCK
AutoCAD SHX Text
SNELL LOCK ROAD
AutoCAD SHX Text
TO ROBINSON BAY ROAD
AutoCAD SHX Text W.E.
AutoCAD SHX Text
SNELL LOCK
AutoCAD SHX Text W.E.
AutoCAD SHX Text W.E.
AutoCAD SHX Text N67
AutoCAD SHX Text
EISENHOWER LOCK
AutoCAD SHX Text
NORTH OVERLOOK PARKING AREA
AutoCAD SHX Text
VISITORS CENTER
AutoCAD SHX Text
VISITORS CENTER RESTROOM /SECURITY BUILDING
AutoCAD SHX Text
EISENHOWER LOCK ROAD TO BARNHART ISLAND ROAD
AutoCAD SHX Text BARNHART ISLAND ROAD TO ST. ISLAND ROAD TO ST. ISLAND ROAD TO ST. ROAD TO ST. ROAD TO ST. TO ST. TO ST. ST. ST. LAWRENCE/FDR POWER PROJECT
AutoCAD SHX Text
AKC
AutoCAD SHX Text
TAO
AutoCAD SHX Text
EISENHOWER DOWNSTREAM SHIP ARRESTOR - FENDER #2
AutoCAD SHX Text
SNELL UPSTREAM SHIP ARRESTOR - FENDER #1
AutoCAD SHX Text
SNELL DOWNSTREAM SHIP ARRESTOR - FENDER #2
AutoCAD SHX Text
EISENHOWER LOCK SITE MAP SCALE: NOT TO SCALE
AutoCAD SHX Text
SNELL LOCK SITE MAP SCALE: NOT TO SCALE
AutoCAD SHX Text
PROJECT SITE MAP SCALE: NOT TO SCALE
AutoCAD SHX Text
MASSENA AREA SITE MAP SCALE: NOT TO SCALE
AutoCAD SHX Text
EISENHOWER UPSTREAM SHIP ARRESTOR - FENDER #1
AutoCAD SHX Text N
N
GENERAL NOTES:
1. THE "TYPICAL SHIP ARRESTOR BOOM AND PIN MACHINERY RECESS LAYOUT DETAIL" MAY VARY SOMEWHAT FROM LOCATION TO LOCATION.
THE DETAIL IS TO CONVEY INTENT AND BASIC EQUIPMENT LAYOUT ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY
EACH LOCATION.
2. THIS LAYOUT IS TYPICAL FOR FOUR (4) LOCATIONS, THEY ARE , EISENHOWER LOCK FENDER #1 AND FENDER #2, SNELL LOCK FENDER #1
AND FENDER #2.
3. FOR THE SCOPE OF THIS PROJECT THE MAJOR COMPONENTS THAT THE CONTRACTOR SHALL DEMOLISH AND INSTALL NEW INCLUDES
BOOM HYDRAULIC POWER UNIT (HPU), PIN HPU, BOOM CYLINDER AND PIN CYLINDER. THE LISTED EQUIPMENT COMPONENTS ARE
CONSISTENT FOR ONE FENDER ASSEMBLY(ALSO REFEREED TO AS SHIP ARRESTOR).
4. THE BOOM HPU, PIN HPU, BOOM CYLINDERS AND PIN CYLINDERS HAVE BEEN PROCURED BY THE SAINT LAWRENCE SEAWAY
DEVELOPMENT CORPORATION (SLSDC) AND WILL BE FURNISHED TO THE CONTRACTOR FOR CONTRACTOR INSTALLATION.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION AS OUTLINED IN THE PLANS AND SPECIFICATIONS AND INSTALLATION OF
ALL NEW EQUIPMENT AS OUTLINED IN THE PLANS AND SPECIFICATIONS.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL APPURTENANCES REQUIRED FOR A COMPLETE INSTALL, SUCH AS BUT NOT LIMITED
TO, CONDUIT, WIRING, JUNCTION BOXES, CABLE, PIPE FITTINGS, ETC. ALL FASTENERS, ANCHORAGE, BOLTS, NUTS, WASHERS, STRUT, ETC.
SHALL BE STAINLESS STEEL.
AutoCAD SHX Text
HPU
AutoCAD SHX Text
HPU
AutoCAD SHX Text
HYDRAULIC EQUIPMENT MACHINERY RECESS - BOOM SIDE
AutoCAD SHX Text
FENDER MACHINERY RECESS - BOOM SIDE
AutoCAD SHX Text
BOLLARD RECESS - BOOM SIDE
AutoCAD SHX Text
BRAKE CYLINDER RECESS - BOOM SIDE
AutoCAD SHX Text
BOLLARD RECESS - PIN SIDE
AutoCAD SHX Text
BRAKE CYLINDER RECESS - PIN SIDE
AutoCAD SHX Text
HYDRAULIC EQUIPMENT MACHINERY RECESS - PIN SIDE
AutoCAD SHX Text
GABLE GALLERY
AutoCAD SHX Text
GABLE GALLERY
AutoCAD SHX Text
PIN MACHINERY RECESS
AutoCAD SHX Text
QUADRANT RECESS
AutoCAD SHX Text
SHIP ARRESTOR CABLE RECESS
AutoCAD SHX Text
SHIP ARRESTOR CABLE RECESS
AutoCAD SHX Text
CENTER OF LOCK
AutoCAD SHX Text
CENTER OF LOCK
AutoCAD SHX Text
CENTER OF LOCK
AutoCAD SHX Text
LOCK WALL
AutoCAD SHX Text
LOCK WALL
AutoCAD SHX Text
LOCK WALL
AutoCAD SHX Text
LOCK WALL
AutoCAD SHX Text
LOCK WALL
AutoCAD SHX Text
LOCK WALL
AutoCAD SHX Text
LOCK WALL
AutoCAD SHX Text
PIN SIDE HPU
AutoCAD SHX Text
PIN CYLINDER
AutoCAD SHX Text
BOOM CYLINDER
AutoCAD SHX Text
BOOM SIDE HPU
AutoCAD SHX Text
SHIP ARRESTOR BOOM
AutoCAD SHX Text
4" PIPE SLEEVE FOR PIN CYLINDER HYDRAULIC LINES
AutoCAD SHX Text
TWO ELECTRICAL CONDUITS FOR LIMIT SWITCHES
AutoCAD SHX Text
3" BREAK CYLINDER VENT LINE SLEEVE
AutoCAD SHX Text
SLEEVE FOR BREAK CYLINDER HYDRAULIC LINES
AutoCAD SHX Text
THROUGH WALL SLEEVES
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
AREA OF WORK
AutoCAD SHX Text
PIPE SLEEVE FOR BREAK CYLINDER HYDRAULIC LINES
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text
SLSDC
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
COORDINATED:
AutoCAD SHX Text
RECOMMENDED:
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
OFFICE OF ENGINEERING AND MAINTENANCE
AutoCAD SHX Text
MASSENA, NEW YORK
AutoCAD SHX Text
DEVELOPMENT CORPORATION
AutoCAD SHX Text
SAINT LAWRENCE SEAWAY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
OF
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SLS-370-246/2
AutoCAD SHX Text
TAO
AutoCAD SHX Text
TAO
AutoCAD SHX Text
AKC
AutoCAD SHX Text 11/01/19
AutoCAD SHX Text
TYPICAL SHIP ARRESTOR BOOM AND PIN MACHINERY RECESS PLAN SCALE: NOT TO SCALE
EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES MACHINERY RECESS PLAN
S
KEY NOTES:
1. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING HPU UNIT AND ALL ASSOCIATED HYDRAULIC AND ELECTRICAL
CONNECTIONS. CONTRACTOR SHALL DRAIN AND DISPOSE OF ALL HYDRAULIC FLUID.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING WALL MOUNTED HYDRAULIC MANIFOLD AND RELATED EQUIPMENT.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING 3" BREAK CYLINDER VENT LINE. LINE SHALL BE REMOVED BACK TO BREAK
CYLINDER RECESS, VENT LINE TAKES A 90 DEGREE BEND AFTER IN ENTERS RECESS. BEND AND FIRST SECTION OF STRAIGHT PIPE SHALL
BE REMOVED.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING KLEEN VENT.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING HYDRAULIC LINES.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING HYDRAULIC CYLINDER. THE BOOM CYLINDER HAS A HEAT TRACE TAPE AND
BLANKET THAT SHALL NEED TO BE REMOVED.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ELECTRIC HEATER, HEATER HOOD, AND HEATER WALL MOUNTED BRACKET.
CONTRACTOR SHALL STORE FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE ALL RELATED WIRING AND CONDUIT.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING HPU CONTROL PANEL AND STORE FOR RE-INSTALLMENT. CONTRACTOR SHALL
REMOVE ALL RELATED WIRING AND CONDUIT. SEE TYPICAL PIN AND BOOM HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM FOR
ADDITIONAL DETAILS.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING EQUIPMENT RELATED DISCONNECT AND ALL ASSOCIATED WIRING.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING SPEAKER AND STORE FOR RE-INSTALLMENT. CONTRACTOR SHALL
REMOVE ALL EXISTING WIRING.
11. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL LIGHTING FIXTURES AND ASSOCIATED WIRING, CONDUITS, SWITCHES AND
JUNCTION BOXES.
12. THERE ARE THREE PROXIMITY SWITCHES FOR INDICATING BOOM POSITION. CONTRACTOR SHALL REMOVE ALL THREE PROXIMITY
SWITCHES, MOUNTING BRACKETS AND WIRING BACK TO HYDRAULIC CONTROL PANEL (HCP). CONTRACTOR SHALL STORE BRACKETS AND
PROXIMITY SWITCHES FOR RE-INSTALLMENT. SEE TYPICAL BOOM HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM FOR ADDITIONAL
DETAILS.
13. CONTRACTOR SHALL REMOVE ALL CONVENIENCE AND UTILIZATION RECEPTACLES AND ASSOCIATED WIRING,, ANCHORAGE AND CONDUITS.
14. BOOM POSITION INDICATOR SHALL REMAIN IN PLACE. TWO EXISTING 1/2" STAINLESS STEEL BREAK CYLINDER HYDRAULIC LINES TO REMAIN.
GENERAL NOTES:
1. THE CONTRACTOR SHALL BE REQUIRED TO REMOVE THE EXISTING RECESS ACCESS COVERS FOR REMOVAL AND
INSTALLATION OF NEW HPU UNITS. REFER TO RECESS COVER REMOVAL AND INSTALLATION PLAN FOR DETAILS.
2. THE "TYPICAL DEMOLITION MACHINERY RECESS PLAN - TYPICAL" IS CONSISTENT FOR ONE SHIP ARRESTOR BOOM AND PIN HPU
SYSTEM (FENDER). ACTUAL LOCATION AND RELATED ACCESSORIES IN EACH RECESS MACHINERY ROOM MAY VARY. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL EQUIPMENT INCLUDING BUT NOT LIMITED TO, PIPING, WRING, CONDUIT, ELECTRICAL DEVICES, CONTROL PANEL, JUNCTION BOXES, WALL HANGERS, LIGHTING FIXTURES, SPEAKERS, RECEPTACLES, LIGHT SWITCHES, DISCONNECTS, CABLE TRAY, UNIT HEATERS, HEATER COVER, HEATER WALL MOUNTED
BRACKET AND ANY OTHER DEVICES REQUIRED TO STRIP THE RECESS AREAS DOWN TO BARE WALLS.
3. RECESS MACHINERY ROOM AND HPU UNIT DIMENSIONS ARE SCALED AS INDICATED. OTHER RELATED EQUIPMENT MAY NOT
BE TO SCALE.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL EQUIPMENT WHICH THE SLSDC DOES NOT WISH TO RETAIN.
THE SLDSC WILL COORDINATE REQUIREMENTS WITH CONTRACTOR DURING CONSTRUCTION.
5. ALL EXISTING USED AND UNUSED WALL ANCHORAGE SHALL BE REMOVED, ALL WALL PENETRATIONS FOR ANCHORAGE SHALL
BE PATCHED.
HPU CONTROL
PANEL
COMMUNICATION CABLING
HPU MOTOR HEATER CABLE
PIN PROX SWITCH CABLE (BPS1)
BOOM CYLINDER SOLENOID CABLE
COMMUNICATION WIRING TO PLC
PIN PROX SWITCH CABLE (BPS2)
SEE NOTE 1.
SEE NOTE 2.
SEE NOTE 3.
SEE NOTE 3.
SEE NOTE 4.
SEE NOTE 5.
HPU CONTROL
PANEL
COMMUNICATION CABLING
HPU MOTOR HEATER CABLE
BOOM PROX SWITCH CABLE (BPS1)
BOOM CYLINDER SOLENOID CABLE
COMMUNICATION WIRING TO PLC
BOOM PROX SWITCH CABLE (BPS2)
BOOM PROX SWITCH CABLE (BPS3)
SEE NOTE 1.
SEE NOTE 2.
SEE NOTE 3.
SEE NOTE 3.
SEE NOTE 3.
SEE NOTE 4.
SEE NOTE 5.
AutoCAD SHX Text
HYDRAULIC EQUIPMENT MACHINERY RECESS - BOOM SIDE
AutoCAD SHX Text
FENDER MACHINERY RECESS - BOOM SIDE
AutoCAD SHX Text
BOLLARD RECESS - BOOM SIDE
AutoCAD SHX Text
BRAKE CYLINDER RECESS - BOOM SIDE
AutoCAD SHX Text
BRAKE CYLINDER RECESS - PIN SIDE
AutoCAD SHX Text
HYDRAULIC EQUIPMENT MACHINERY RECESS - PIN SIDE
AutoCAD SHX Text
GABLE GALLERY
AutoCAD SHX Text
PIN MACHINERY RECESS
AutoCAD SHX Text
SHIP ARRESTOR CABLE RECESS
AutoCAD SHX Text
LT
AutoCAD SHX Text
LT
AutoCAD SHX Text
LT
AutoCAD SHX Text
UH
AutoCAD SHX Text S
AutoCAD SHX Text
HCP
AutoCAD SHX Text
PS1
AutoCAD SHX Text
PS2
AutoCAD SHX Text
PS3
AutoCAD SHX Text
JB
AutoCAD SHX Text
JB
AutoCAD SHX Text
HPU
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LT
AutoCAD SHX Text
UH
AutoCAD SHX Text S
AutoCAD SHX Text
HCP
AutoCAD SHX Text
HPU
AutoCAD SHX Text
LT
AutoCAD SHX Text
LT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SHIPS LADDER
AutoCAD SHX Text
SHIPS LADDER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text
SLSDC
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
COORDINATED:
AutoCAD SHX Text
RECOMMENDED:
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
OFFICE OF ENGINEERING AND MAINTENANCE
AutoCAD SHX Text
MASSENA, NEW YORK
AutoCAD SHX Text
DEVELOPMENT CORPORATION
AutoCAD SHX Text
SAINT LAWRENCE SEAWAY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
OF
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SLS-370-246/3
AutoCAD SHX Text
TAO
AutoCAD SHX Text
TAO
AutoCAD SHX Text
AKC
AutoCAD SHX Text 11/01/19
AutoCAD SHX Text
TYPICAL DEMOLITION MACHINERY RECESS PLAN - TYPICAL SCALE: 3/8" = 1'-0"
AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES DEMOLITION PLAN
AutoCAD SHX Text
TYPICAL PIN HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM SCALE: NOT TO SCALE
AutoCAD SHX Text 1)
AutoCAD SHX Text 2)
AutoCAD SHX Text TYPICAL PIN HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM NOTES: NOTES: : CONTRACTOR SHALL REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY SHALL REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY SHALL REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CONTROL WIRING CABLE BACK TO CABLE GALLERY CONTROL WIRING CABLE BACK TO CABLE GALLERY WIRING CABLE BACK TO CABLE GALLERY WIRING CABLE BACK TO CABLE GALLERY CABLE BACK TO CABLE GALLERY CABLE BACK TO CABLE GALLERY BACK TO CABLE GALLERY BACK TO CABLE GALLERY TO CABLE GALLERY TO CABLE GALLERY CABLE GALLERY CABLE GALLERY GALLERY GALLERY CABLE TRAY LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR TRAY LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR TRAY LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR CONTROL WIRING CABLE SHALL BE SECURED FOR CONTROL WIRING CABLE SHALL BE SECURED FOR WIRING CABLE SHALL BE SECURED FOR WIRING CABLE SHALL BE SECURED FOR CABLE SHALL BE SECURED FOR CABLE SHALL BE SECURED FOR SHALL BE SECURED FOR SHALL BE SECURED FOR BE SECURED FOR BE SECURED FOR SECURED FOR SECURED FOR FOR FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE PIN CYLINDER SOLENOID CABLE. CONTRACTOR SHALL REMOVE PIN CYLINDER PROXIMITY SWITCH CABLE AND STORE FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE HPU MOTOR HEATER CABLE. CONTRACTOR SHALL REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY SHALL REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY SHALL REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY CABLES BACK TO CABLE GALLERY CABLE TRAY CABLES BACK TO CABLE GALLERY CABLE TRAY BACK TO CABLE GALLERY CABLE TRAY BACK TO CABLE GALLERY CABLE TRAY TO CABLE GALLERY CABLE TRAY TO CABLE GALLERY CABLE TRAY CABLE GALLERY CABLE TRAY CABLE GALLERY CABLE TRAY GALLERY CABLE TRAY GALLERY CABLE TRAY CABLE TRAY CABLE TRAY TRAY TRAY LOCATED JUST OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE JUST OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE JUST OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE COMMUNICATION CABLES, TWO ETHERNET AND ONE COMMUNICATION CABLES, TWO ETHERNET AND ONE CABLES, TWO ETHERNET AND ONE CABLES, TWO ETHERNET AND ONE TWO ETHERNET AND ONE TWO ETHERNET AND ONE ETHERNET AND ONE ETHERNET AND ONE AND ONE AND ONE ONE ONE TWISTED PAIR. CABLES SHALL BE SECURED FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, CONDUIT, CABLE TRAY, ANCHORAGE, CONDUIT, CABLE TRAY, ANCHORAGE, CABLE TRAY, ANCHORAGE, CABLE TRAY, ANCHORAGE, TRAY, ANCHORAGE, TRAY, ANCHORAGE, ANCHORAGE, ANCHORAGE, FITTINGS AND ANY OTHER RELATED EQUIPMENT ASSOCIATED WITH HPU CONTROL PANEL CIRCUITS.
AutoCAD SHX Text 3)
AutoCAD SHX Text 4)
AutoCAD SHX Text 5)
AutoCAD SHX Text
TYPICAL BOOM HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM SCALE: NOT TO SCALE
AutoCAD SHX Text 1)
AutoCAD SHX Text 2)
AutoCAD SHX Text TYPICAL BOOM HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM NOTES: NOTES: : CONTRACTOR SHALL REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE SHALL REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE SHALL REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE WIRING CABLE BACK TO CABLE GALLERY CABLE WIRING CABLE BACK TO CABLE GALLERY CABLE CABLE BACK TO CABLE GALLERY CABLE CABLE BACK TO CABLE GALLERY CABLE BACK TO CABLE GALLERY CABLE BACK TO CABLE GALLERY CABLE TO CABLE GALLERY CABLE TO CABLE GALLERY CABLE CABLE GALLERY CABLE CABLE GALLERY CABLE GALLERY CABLE GALLERY CABLE CABLE CABLE TRAY OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE BOOM CYLINDER SOLENOID CABLE. CONTRACTOR SHALL REMOVE PROXIMITY SWITCH CABLE. CONTRACTOR SHALL REMOVE HPU MOTOR HEATER CABLE CONTRACTOR SHALL REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE SHALL REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE SHALL REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE BACK TO CABLE GALLERY CABLE TRAY OUTSIDE BACK TO CABLE GALLERY CABLE TRAY OUTSIDE TO CABLE GALLERY CABLE TRAY OUTSIDE TO CABLE GALLERY CABLE TRAY OUTSIDE CABLE GALLERY CABLE TRAY OUTSIDE CABLE GALLERY CABLE TRAY OUTSIDE GALLERY CABLE TRAY OUTSIDE GALLERY CABLE TRAY OUTSIDE CABLE TRAY OUTSIDE CABLE TRAY OUTSIDE TRAY OUTSIDE TRAY OUTSIDE OUTSIDE OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES TWO ETHERNET AND ONE TWISTED PAIR. CABLES TWO ETHERNET AND ONE TWISTED PAIR. CABLES ETHERNET AND ONE TWISTED PAIR. CABLES ETHERNET AND ONE TWISTED PAIR. CABLES AND ONE TWISTED PAIR. CABLES AND ONE TWISTED PAIR. CABLES ONE TWISTED PAIR. CABLES ONE TWISTED PAIR. CABLES TWISTED PAIR. CABLES TWISTED PAIR. CABLES PAIR. CABLES PAIR. CABLES CABLES CABLES SHALL BE SECURED FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, CONDUIT, CABLE TRAY, ANCHORAGE, CONDUIT, CABLE TRAY, ANCHORAGE, CABLE TRAY, ANCHORAGE, CABLE TRAY, ANCHORAGE, TRAY, ANCHORAGE, TRAY, ANCHORAGE, ANCHORAGE, ANCHORAGE, FITTINGS AND ANY OTHER RELATED EQUIPMENT ASSOCIATED WITH HPU CONTROL PANEL CIRCUITS.
AutoCAD SHX Text 3)
AutoCAD SHX Text 4)
AutoCAD SHX Text 5)
AutoCAD SHX Text 6)
6)
KEY NOTES:
1. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SLSDC SUPPLIED HPU UNIT AS PER MANUFACTURERS WRITTEN INSTRUCTIONS.
INSTALLATION REQUIREMENTS INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING:
1.1. HPU SHALL BE SECURELY ANCHORED TO CONCRETE FLOOR.
1.2. PUMP MOTOR BRANCH CIRCUIT
1.3. MOTOR HEATER BRANCH CIRCUIT
1.4. BOOM/PIN SOLENOID WIRING
1.5. INITIAL FILL OF HYDRAULIC FLUID, TANK IS SHIPPED EMPTIED.
1.6. ALL HYDRAULIC LINES INTERCONNECTIONS (REFER TO BOOM AND PIN HYDRAULIC SCHEMATICS FOR ADDITIONAL DETAILS)
2. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SLSDC SUPPLIED 3" BREAK CYLINDER VENT LINE VALVE.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING NEW 3" BREAK CYLINDER VENT LINE FROM HPU UNIT TO CONNECTION POINT IN
BREAK CYLINDER RECESS. VENT LINE TAKES A 90 DEGREE BEND AFTER IT ENTERS BREAK CYLINDER RECESS. BEND AND FIRST SECTION
OF STRAIGHT PIPE SHALL BE REPLACED BY CONTRACTOR. CONTRACTOR SHALL PAINT PIPE AS REQUIRED BY SLSDC.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SLSDC SUPPLIED PIN CYLINDER. CONTRACTOR SHALL COORDINATE INSTALLATION
AND ALIGNMENT REQUIREMENTS WITH SLSDC PRIOR TO DOING ANY WORK.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SLSDC SUPPLIED BOOM CYLINDER. CONTRACTOR SHALL COORDINATE
INSTALLATION AND ALIGNMENT REQUIREMENTS WITH SLSDC PRIOR TO DOING ANY WORK.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR NEW HYDRAULIC LINES FROM BOOM MANIFOLD ON NEW HPU TO BOOM CYLINDER. HYDRAULIC
TUBING, HYDRAULIC HOSE, MOUNTING AND ROUTING SHALL BE COORDINATED WITH SLSDC PRIOR TO DOING ANY WORK. ALL REQUIRED
FITTINGS, ANCHORAGE AND FASTENERS SHALL BE STAINLESS STEEL.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING EXISTING HYDRAULIC LINES TO RECESS CONCRETE WALL. CONTRACTOR SHALL
INSTALL STAINLESS STEEL STRUT EVERY SIX FEET AND ANCHOR HYDRAULIC TUBING TO STRUT.
8. CONTRACTOR SHALL CONNECT NEW HYDRAULIC LINES FROM HPU MANIFOLD TO EXISTING HYDRAULIC LINES IN THIS AREA. CONTRACTOR
SHALL MODIFY AS NEEDED.
GENERAL NOTES:
1. ALL ANCHORS, FASTENERS, STRUT, BOLTS, WASHERS SCREWS AND ANY OTHER MATERIAL USED FOR SECURING EQUIPMENT
IN THE RECESS AREAS SHALL BE STAINLESS STEEL.
2. CONTRACTOR SHALL INSTALL ALL EQUIPMENT AS PER MANUFACTURERS WRITTEN INSTRUCTIONS.
3. THE "TYPICAL PROPOSED MACHINERY RECESS MECHANICAL PLAN" IS INTENDED TO CONVEY INTENT ONLY FOR A TYPICAL
BOOM AND PIN RECESS INSTALL. ACTUAL EQUIPMENT LOCATIONS MAY VARY, INCLUDING BUT NOT LIMITED TO, INCIDENTAL
DEVICES, SUCH AS, RECEPTACLES, SWITCHES, DISCONNECTS, LIGHT FIXTURES, ETC.
4. CONTRACTOR SHALL VERIFY FINAL EQUIPMENT LOCATION WITH SLSDC PRIOR TO DOING ANY WORK.
AutoCAD SHX Text
FENDER MACHINERY RECESS - BOOM SIDE
AutoCAD SHX Text
BOLLARD RECESS - BOOM SIDE
AutoCAD SHX Text
BRAKE CYLINDER RECESS - BOOM SIDE
AutoCAD SHX Text
BRAKE CYLINDER RECESS - PIN SIDE
AutoCAD SHX Text
GABLE GALLERY
AutoCAD SHX Text
PIN MACHINERY RECESS
AutoCAD SHX Text
SHIP ARRESTOR CABLE RECESS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SHIPS LADDER
AutoCAD SHX Text
SHIPS LADDER
AutoCAD SHX Text
AutoCAD SHX Text
HPU
AutoCAD SHX Text
AutoCAD SHX Text
HPU
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
STATION MANIFOLD - BOOM ONLY
AutoCAD SHX Text
ANCHOR POINT- TYPICAL
AutoCAD SHX Text
3" BREAK CYLINDER VENT
AutoCAD SHX Text
STATION MANIFOLD - PIN ONLY
AutoCAD SHX Text
STATION MANIFOLD - PIN ONLY
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
RETURN FILTER
AutoCAD SHX Text
KLEEN VENT
AutoCAD SHX Text
HEATER
AutoCAD SHX Text
PUMP MOTOR
AutoCAD SHX Text
ELECTRICAL ENCLOSURE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text
SLSDC
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
COORDINATED:
AutoCAD SHX Text
RECOMMENDED:
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
OFFICE OF ENGINEERING AND MAINTENANCE
AutoCAD SHX Text
MASSENA, NEW YORK
AutoCAD SHX Text
DEVELOPMENT CORPORATION
AutoCAD SHX Text
SAINT LAWRENCE SEAWAY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
OF
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SLS-370-246/4
AutoCAD SHX Text
TAO
AutoCAD SHX Text
TAO
AutoCAD SHX Text
AKC
AutoCAD SHX Text 11/01/19
AutoCAD SHX Text
TYPICAL PROPOSED MACHINERY RECESS MECHANICAL PLAN SCALE: 3/8" = 1'-0"
AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES PROPOSED MECHANICAL PLAN
TYPICAL HYDRAULIC POWER UNIT ISOMETRIC AND PLAN VIEW SCALE: NONE
S
KEY NOTES:
1. CONTRACTOR SHALL BE RESPONSIBLE FOR RE-INSTALLING HYDRAULIC UNIT CONTROL PANEL. REFER TO HPU CONTROL PANEL WIRING
DIAGRAMS FOR ADDITIONAL DETAILS.
2. CONTRACTOR SHALL PROVIDE STAINLESS STEEL MOTOR DISCONNECT, 7.5HP RATED, 480V, 3 PHASE.
3. CONTRACTOR SHALL PROVIDE STAINLESS STEEL MOTOR HEATER DISCONNECT, VERIFY SIZE WITH MANUFACTURE.
4. CONTRACTOR SHALL ADJUST PROXIMITY SWITCHES AS NEEDED AFTER NEW PIN CYLINDER IS INSTALLED.
5. CONTRACTOR SHALL MODIFY EXISTING HEAT TRACE BRANCH CIRCUIT FOR BOOM CYLINDER. CONTRACTOR SHALL INSTALL BRANCH
CIRCUIT IN SCHEDULE 80 PVC CONDUIT AND PROVIDE WEATHER PROOF RECEPTACLE.
6. CONTRACTOR SHALL PROVIDE GENERAL PURPOSE WEATHERPROOF RECEPTACLE. CONTRACTOR SHALL INSTALL BRANCH CIRCUIT IN
SCHEDULE 80 PVC CONDUIT.
7. CONTRACTOR SHALL SUPPLY 60AMP, 480V, THREE PHASE STAINLESS STEEL DISCONNECT TO REPLACE EXISTING WELDING DISCONNECT.
CONTRACTOR SHALL REUSE EXISTING WELDING DISCONNECT BRANCH CIRCUIT. BRANCH CIRCUIT SHALL BE INSTALLED IN SCHEDULE 80
PVC CONDUIT. FINAL LOCATION TO BE FIELD DETERMINED WITH SLSDC.
8. CONTRACTOR SHALL INSTALL NEW LIGHTING IN RECESS INCLUDING ALL LIGHTING FIXTURES, SCHEDULE 80 PVC CONDUIT AND BOXES, WIRING AND TOGGLE SWITCHES. CONTRACTOR SHALL REUSE EXISTING LIGHTING FIXTURE BRANCH CIRCUIT WHICH SERVES THE RECESS.
LIGHTING FIXTURE SHALL BE C-LITE C-VTB-19L-40K OR EQUAL.
9. CONTRACTOR SHALL INSTALL NEW TOGGLE SWITCH, SCHEDULE 80 PVC CONDUIT AND WIRING FOR EXISTING BREAK CYLINDER LIGHTING
CIRCUIT.
10. CONTRACTOR SHALL RE-INSTALL EXISTING PROXIMITY SWITCHES. CONTRACTOR SHALL INSTALL ALL WIRING IN SCHEDULE 80 PVC
CONDUIT. CONTRACTOR SHALL REFINISH AND PAINT PROXIMITY SWITCH MOUNTING BRACKETS.
GENERAL NOTES:
1. ALL FITTINGS, ANCHORS, FASTENERS, STRUT, BOLTS, WASHERS SCREWS. ETC.INSTALLED IN THE RECESS AREAS SHALL BE
STAINLESS STEEL.
2. CONTRACTOR SHALL INSTALL ALL EQUIPMENT AS PER MANUFACTURERS WRITTEN INSTRUCTIONS.
3. THE "TYPICAL PROPOSED MACHINERY RECESS ELECTRICAL PLAN" IS INTENDED TO CONVEY INTENT ONLY FOR A TYPICAL
BOOM AND PIN RECESS INSTALL. ACTUAL EQUIPMENT LOCATIONS MAY VARY, INCLUDING BUT NOT LIMITED TO, INCIDENTAL
DEVICES, SUCH AS, RECEPTACLES, SWITCHES, DISCONNECTS, LIGHT FIXTURES, ETC.
4. CONTRACTOR SHALL VERIFY FINAL EQUIPMENT LOCATION WITH SLSDC PRIOR TO DOING ANY WORK.
5. ALL CONDUITS AND FITTINGS SHALL BE SCHEDULE 80 PVC.
6. ALL WIRING SHALL BE CABLE TRAY RATED.
7. ALL CONDUIT RUNS SHALL BE SECURED TO WALL MOUNTED STAINLESS STEEL STRUT. CONTRACTOR SHALL REVIEW CONDUIT
PLAN WITH SLSDC PRIOR TO DOING ANY WORK.
8. ALL WORK SHALL BE IN COMPLIANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE.
HPU CONTROL
PANEL
COMMUNICATION CABLING
HPU MOTOR HEATER CABLE
PIN PROX SWITCH CABLE (BPS1)
BOOM CYLINDER SOLENOID CABLE
COMMUNICATION WIRING TO PLC
PIN PROX SWITCH CABLE (BPS2)
SEE NOTE 1.
SEE NOTE 2.
SEE NOTE 3.
SEE NOTE 3.
SEE NOTE 4.
SEE NOTE 5.
HPU CONTROL
PANEL
COMMUNICATION CABLING
HPU MOTOR HEATER CABLE
BOOM PROX SWITCH CABLE (BPS1)
BOOM CYLINDER SOLENOID CABLE
COMMUNICATION WIRING TO PLC
BOOM PROX SWITCH CABLE (BPS2)
BOOM PROX SWITCH CABLE (BPS3)
SEE NOTE 1.
SEE NOTE 2.
SEE NOTE 3.
SEE NOTE 3.
SEE NOTE 3.
SEE NOTE 4.
SEE NOTE 5.
AutoCAD SHX Text
PS1
AutoCAD SHX Text
PS2
AutoCAD SHX Text
PS3
AutoCAD SHX Text
AutoCAD SHX Text
FENDER MACHINERY RECESS - BOOM SIDE
AutoCAD SHX Text
BOLLARD RECESS - BOOM SIDE
AutoCAD SHX Text
BRAKE CYLINDER RECESS - BOOM SIDE
AutoCAD SHX Text
BRAKE CYLINDER RECESS - PIN SIDE
AutoCAD SHX Text
GABLE GALLERY
AutoCAD SHX Text
PIN MACHINERY RECESS
AutoCAD SHX Text
SHIP ARRESTOR CABLE RECESS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HPU
AutoCAD SHX Text
HPU
AutoCAD SHX Text
LT
AutoCAD SHX Text
LT
AutoCAD SHX Text
LT
AutoCAD SHX Text
LT
AutoCAD SHX Text
LT
AutoCAD SHX Text
HCP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HCP
AutoCAD SHX Text
AutoCAD SHX Text
LT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LT
AutoCAD SHX Text
LT
AutoCAD SHX Text
LT
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text
SLSDC
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
COORDINATED:
AutoCAD SHX Text
RECOMMENDED:
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
OFFICE OF ENGINEERING AND MAINTENANCE
AutoCAD SHX Text
MASSENA, NEW YORK
AutoCAD SHX Text
DEVELOPMENT CORPORATION
AutoCAD SHX Text
SAINT LAWRENCE SEAWAY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
OF
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SLS-370-246/5
AutoCAD SHX Text
TAO
AutoCAD SHX Text
TAO
AutoCAD SHX Text
AKC
AutoCAD SHX Text 11/01/19
AutoCAD SHX Text
TYPICAL PROPOSED MACHINERY RECESS ELECTRICAL PLAN SCALE: 3/8" = 1'-0"
AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES PROPOSED ELECTRICAL PLAN
AutoCAD SHX Text
TYPICAL PIN HPU CONTROL PANEL WIRING DIAGRAM SCALE: NOT TO SCALE
AutoCAD SHX Text 1)
AutoCAD SHX Text 2)
AutoCAD SHX Text TYPICAL PIN HPU CONTROL PANEL WIRING DIAGRAM NOTES: NOTES: : CONTRACTOR SHALL RE-INSTALL MULTI-CONDUCTOR CONTROL WIRING CABLE. CONTRACTOR SHALL INSTALL PIN CYLINDER SOLENOID CABLE. CONTRACTOR SHALL RE-INSTALL PIN CYLINDER PROXIMITY SWITCH CABLE. CONTRACTOR SHALL INSTALL HPU MOTOR HEATER CABLE. CONTRACTOR SHALL RE-INSTALL THREE COMMUNICATION CABLES. ALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL ALL CONDUIT SHALL BE SECURED TO WALL ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT SHALL BE SECURED TO WALL CONDUIT SHALL BE SECURED TO WALL SHALL BE SECURED TO WALL SHALL BE SECURED TO WALL BE SECURED TO WALL BE SECURED TO WALL SECURED TO WALL SECURED TO WALL TO WALL TO WALL WALL WALL MOUNTED STAINLESS STEEL STRUT.
AutoCAD SHX Text 3)
AutoCAD SHX Text 4)
AutoCAD SHX Text 5)
AutoCAD SHX Text
TYPICAL BOOM HPU CONTROL PANEL BOOM WIRING DIAGRAM SCALE: NOT TO SCALE
AutoCAD SHX Text 6)
AutoCAD SHX Text 1)
AutoCAD SHX Text 2)
AutoCAD SHX Text TYPICAL BOOM HPU CONTROL PANEL WIRING DIAGRAM NOTES: NOTES: : CONTRACTOR SHALL RE-INSTALL MULTI-CONDUCTOR CONTROL WIRING CABLE. CONTRACTOR SHALL INSTALL BOOM CYLINDER SOLENOID CABLE. CONTRACTOR SHALL RE-INSTALL BOOM CYLINDER PROXIMITY SWITCH CABLE. CONTRACTOR SHALL INSTALL HPU MOTOR HEATER CABLE. CONTRACTOR SHALL RE-INSTALL THREE COMMUNICATION CABLES. ALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL ALL CONDUIT SHALL BE SECURED TO WALL ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT SHALL BE SECURED TO WALL CONDUIT SHALL BE SECURED TO WALL SHALL BE SECURED TO WALL SHALL BE SECURED TO WALL BE SECURED TO WALL BE SECURED TO WALL SECURED TO WALL SECURED TO WALL TO WALL TO WALL WALL WALL MOUNTED STAINLESS STEEL STRUT.
AutoCAD SHX Text 3)
AutoCAD SHX Text 4)
AutoCAD SHX Text 5)
6)
150 GALLON
B
A
100%
M
P
B
A
100%
S
P
1500 PSI
SET AT
PDB
XDB
TDB
1000 PSI
SET AT
SZ80
P
T
A1 B1
P
B3A2 B2 A3
T
P T
SET AT
GA
P a
A
T
B b
P a
A
T
B b a
P
A
T
B b
L2
L1
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text
SLSDC
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
COORDINATED:
AutoCAD SHX Text
RECOMMENDED:
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
OFFICE OF ENGINEERING AND MAINTENANCE
AutoCAD SHX Text
MASSENA, NEW YORK
AutoCAD SHX Text
DEVELOPMENT CORPORATION
AutoCAD SHX Text
SAINT LAWRENCE SEAWAY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
OF
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SLS-370-246/6
AutoCAD SHX Text
TAO
AutoCAD SHX Text
TAO
AutoCAD SHX Text
AKC
AutoCAD SHX Text 11/01/19
AutoCAD SHX Text
BOOM HPU HYDRAULIC SCHEMATIC SCALE: NONE
AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES HYDRAULIC SCHEMATIC BOOM HPU
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
JUNCTION
AutoCAD SHX Text
BOX
AutoCAD SHX Text
LIMIT OF POWER UNIT
AutoCAD SHX Text
Q1 = 6 GPM
AutoCAD SHX Text p1 = 1500 PSI
AutoCAD SHX Text
P = 7-1/2 HP
AutoCAD SHX Text n = 1800 RPM
AutoCAD SHX Text
%%UCONNECTIONS
AutoCAD SHX Text
%%UBRAKE CYLINDER
AutoCAD SHX Text P1
AutoCAD SHX Text P2
AutoCAD SHX Text
Q2 = 6 GPM
AutoCAD SHX Text p2 = 1000 PSI
AutoCAD SHX Text
AutoCAD SHX Text
SZ10
AutoCAD SHX Text
AutoCAD SHX Text
SZ10
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SZ10
AutoCAD SHX Text
AutoCAD SHX Text
SZ10
AutoCAD SHX Text
AutoCAD SHX Text R1
AutoCAD SHX Text B1
AutoCAD SHX Text R2
AutoCAD SHX Text B2
AutoCAD SHX Text
%%UBOOM CYLINDER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 310.1
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text T
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text T
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text T
AutoCAD SHX Text 550.1
AutoCAD SHX Text 550.2
AutoCAD SHX Text
AutoCAD SHX Text
BR2
AutoCAD SHX Text
BR1
AutoCAD SHX Text T2
AutoCAD SHX Text
LOOSE
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text
TO T.P.#130
AutoCAD SHX Text P,T,A,B,A1,B1,A2,B2,A3,B3 =
AutoCAD SHX Text
1-1/16-12 SAE (-12)
AutoCAD SHX Text
BR1,BR2 =
AutoCAD SHX Text
3/4-16 SAE (-8)
AutoCAD SHX Text T2 =
AutoCAD SHX Text 3" 150lb. ANSI FLG.
AutoCAD SHX Text
SZ20
AutoCAD SHX Text
AutoCAD SHX Text
FILL PORT
AutoCAD SHX Text
AutoCAD SHX Text
SZ15
AutoCAD SHX Text
5 GAL.
AutoCAD SHX Text 310.2
AutoCAD SHX Text 313.1
AutoCAD SHX Text 313.2
AutoCAD SHX Text
GA =
AutoCAD SHX Text
9/16-18 SAE (-6)
AutoCAD SHX Text P1, P2 =
AutoCAD SHX Text
7/8-14 SAE (-10)
AutoCAD SHX Text S =
AutoCAD SHX Text
1 5/16 SAE (-16)
AutoCAD SHX Text
%%UCONNECTIONS
AutoCAD SHX Text 34 x 0.065
AutoCAD SHX Text 1 x 0.065
AutoCAD SHX Text 1 x 0.065
AutoCAD SHX Text
PDB, TDB =
AutoCAD SHX Text G1/2
AutoCAD SHX Text
XDB =
G1/4
150 GALLON
B
A
100%
M
S
P
B
A
100%
250 PSI
P
T
A B
P
T
P T
SET ATSET AT
1000 PSI
S
P
B
A
100%
SZ80
P a
A
T
B b
P a
A
T
B b
P
A1
T
B1
P
A2 B2
T
GA
P T
SET ATSET AT
a
P
A
T
B b
L2
L1
Tech position
Part number
Part number description
Manufacturer
Quantity per assembly
10 R978064885 OIL RESERVOIR 43AHAG-17158-1 Bosch Rexroth 1
20 R978907302 DMIC BVAL-0750S-4321-AZZA DMIC 1
40 R978011653 ENCLOSURE C-SD12126SS HOFFMAN 4X Hoffman 1
60 R978804856 THERMOMETER BIMET PUA31-14 WIKA 33X0278 WIKA 1
70 R901404478 AIR FILTER KVEU005PWWT50A1 Parker 1
80 R901299368 MAGNETIC SEPARATOR HD-7 X 14"-2" NPT/SS SPS Rockford 1
90 R978802712 CHROMA HEATER ELEM 1PUA32-10/120V Chromalox 1
100 R978888625 TEMP SW 2PUA31-30-00 B402-120-1271 Power Associates 1
110 R978800007 SIGHT GLASS CS3615-244910 LDI Industries 2
120 R978887096 LHA-SEC-100-3-100-RV3 SUCT STRAINER
Donaldson Industrial
Hydraulics
130 R978007870 DMIC BVAL-3000AA-4321-AZZA DMIC 1
140 R928041276
10TEN0100-PWR10A00-P2,2-M-U9
Bosch Rexroth 1
141 R928028409 WE-1SP-M12X1 Bosch Rexroth 1
150 R928049174 BFSK80-2X/H3V3-M-S-CV Bosch Rexroth 1
160 R901269280 ABZMS-41-1X/0800/M2/AC-K14 Bosch Rexroth 1
200 R978064664 MOTOR AC W22-7.5HP-213TC-208-& Bosch Rexroth 1
R978807567 CPL HUB L100 SPL SAE A SPL 33-20
Lovejoy
R978889102 CPL INSERT L099/100 HYTREL
Lovejoy
R978802780 CPL HUB L100 BORED 1 3/8X5/16 KEY 33-20
Lovejoy
220 9510290146 AZPFF-12-014/014RRR1212MB-S0516 Bosch Rexroth 1
250 R928030729
245LEN0063-PWR10A00-V5,0-M-U4
Bosch Rexroth 1
260 R901454073 S 20 A05-1X/450J3/12 Bosch Rexroth 1
270 R978006001
PARKER SH6-63-T12 QUICK DISCONNECT
Parker 1
280 R901454180 S 15 A05-1X/450J3/12 Bosch Rexroth 1
290 R901524046 DB 10 G3-5X/100X Bosch Rexroth 1
310 R978060162 PRESSURE GAUGE 233.53 4 3000PSI 7/1& WIKA 2
400 R978028975 F22T124GVPWK STR SECTION WIREWAY HOFFMAN Hoffman 1
500 R978913414 BM10PN-1X/03D3-12RCR Bosch Rexroth 1
510 R900425162 DBDA 10 K1X/200 Bosch Rexroth 1
520 R901350265 4WMM 10 E5X//M Bosch Rexroth 1
530 R900597186 4WE 10 E3X/CW110N9K4 Bosch Rexroth 1
540 R901350265 4WMM 10 E5X//M Bosch Rexroth 1
550 R987330729 BALL VALVE BVH-0500S-2211-AZZA DMIC 2
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text S
AutoCAD SHX Text Y
AutoCAD SHX Text
SLSDC
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text Y
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
COORDINATED:
AutoCAD SHX Text
RECOMMENDED:
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
OFFICE OF ENGINEERING AND MAINTENANCE
AutoCAD SHX Text
MASSENA, NEW YORK
AutoCAD SHX Text
DEVELOPMENT CORPORATION
AutoCAD SHX Text
SAINT LAWRENCE SEAWAY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
OF
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SLS-370-246/7
AutoCAD SHX Text
TAO
AutoCAD SHX Text
TAO
AutoCAD SHX Text
AKC
AutoCAD SHX Text 11/01/19
AutoCAD SHX Text
PIN HPU HYDRAULIC SCHEMATIC SCALE: NONE
AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES HYDRAULIC SCHEMATIC PIN HPU
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SZ10
AutoCAD SHX Text
AutoCAD SHX Text
SZ10
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SZ10
AutoCAD SHX Text
AutoCAD SHX Text
SZ10
AutoCAD SHX Text
JUNCTION
AutoCAD SHX Text
BOX
AutoCAD SHX Text
BR2
AutoCAD SHX Text
BR1
AutoCAD SHX Text
LIMIT OF POWER UNIT
AutoCAD SHX Text
Q1 = 6 GPM
AutoCAD SHX Text p1 = 1000 PSI
AutoCAD SHX Text
P = 7-1/2 HP
AutoCAD SHX Text n = 1800 RPM
AutoCAD SHX Text
%%UCONNECTIONS
AutoCAD SHX Text
%%UBRAKE CYLINDER
Auto…
This is the start of the file's text. The full file is on GovTribe.