UNITED STATES DEPARTMENT OF TRANSPORTATION,

EISENHOWER AND SNELL LOCKS

SHIP ARRESTOR HYDRAULIC POWER UNITS

SAINT LAWRENCE SEAWAY DEVELOPMENT CORPORATION

AND BOOM/PIN CYLINDER UPGRADES

MASSENA, NEW YORK

AutoCAD SHX Text S

AutoCAD SHX Text Y

AutoCAD SHX Text

SLSDC

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text V

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text U

0.4320

TAO

AutoCAD SHX Text

REV.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text S

AutoCAD SHX Text Y

AutoCAD SHX Text

SLSDC

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text V

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

APPROVED:

AutoCAD SHX Text

COORDINATED:

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

OFFICE OF ENGINEERING AND MAINTENANCE

AutoCAD SHX Text

MASSENA, NEW YORK

AutoCAD SHX Text

DEVELOPMENT CORPORATION

AutoCAD SHX Text

SAINT LAWRENCE SEAWAY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES

AutoCAD SHX Text

OF

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

SLS-370-246/1

AutoCAD SHX Text 11/01/19

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ANDREWS ST.

AutoCAD SHX Text

%%UST. LAWRENCE SEAWAY

AutoCAD SHX Text

%%UADMINISTRATION BUILDING

AutoCAD SHX Text

%%U180 ANDREWS STREET

AutoCAD SHX Text

BAY

AutoCAD SHX Text

WATERTOWN

AutoCAD SHX Text

ALEX.

AutoCAD SHX Text

LAKE ONTARIO

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ONTARIO

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

NEW YORK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CARTHAGE

AutoCAD SHX Text

AutoCAD SHX Text

WADDINGTON

AutoCAD SHX Text

GOUVERNEUR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OGDENSBURG

AutoCAD SHX Text

MORRISTOWN

AutoCAD SHX Text

ST. LAWRENCE RIVER

AutoCAD SHX Text

CANTON

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TUPPER LAKE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

POTSDAM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MALONE

AutoCAD SHX Text

VT.

AutoCAD SHX Text

AutoCAD SHX Text

LAKE CHAMPLAIN

AutoCAD SHX Text

AutoCAD SHX Text

PLATTSBURGH

AutoCAD SHX Text

AutoCAD SHX Text

QUEBEC

AutoCAD SHX Text

PROJECT LOCATION

AutoCAD SHX Text

AutoCAD SHX Text

MASSENA

AutoCAD SHX Text

AutoCAD SHX Text

CORNWALL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ROUSES PT.

AutoCAD SHX Text

TO US/CANADA BRIDGE

AutoCAD SHX Text

%%UST. LAWRENCE SEAWAY

AutoCAD SHX Text

%%UMARINE BASE/

AutoCAD SHX Text

%%UMAINTENANCE FACILITY

AutoCAD SHX Text

MASSENA CENTER ROAD

AutoCAD SHX Text

DONAHUE ROAD

AutoCAD SHX Text

MAIN STREET

AutoCAD SHX Text

RAQUETTE RIVER ROAD

AutoCAD SHX Text

MASSENA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RR TRACKS

AutoCAD SHX Text

EAST ORVIS ST.

AutoCAD SHX Text

MASSENA

AutoCAD SHX Text

AIRPORT

AutoCAD SHX Text

ALCOA

AutoCAD SHX Text

AutoCAD SHX Text

HORTON ROAD

AutoCAD SHX Text

ST. LAWRENCE

AutoCAD SHX Text

CENTRE MALL

AutoCAD SHX Text

DENNISON ROAD

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

%%UEISENHOWER

AutoCAD SHX Text

%%ULOCK

AutoCAD SHX Text

RAQUETTE RIVER ROAD

AutoCAD SHX Text

O'NEIL ROAD

AutoCAD SHX Text

RAQUETTE RIVER

AutoCAD SHX Text

FREGOE ROAD

AutoCAD SHX Text

SO. GRASS RIVER RD.

AutoCAD SHX Text

GRASS RIVER

AutoCAD SHX Text

KINNIE ROAD

AutoCAD SHX Text

AutoCAD SHX Text

ST. LAWRENCE RIVER

AutoCAD SHX Text

TO NYPA

AutoCAD SHX Text

POWER

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

%%USNELL

AutoCAD SHX Text

%%ULOCK

AutoCAD SHX Text

SNELL LOCK ROAD

AutoCAD SHX Text

TO ROBINSON BAY ROAD

AutoCAD SHX Text W.E.

AutoCAD SHX Text

SNELL LOCK

AutoCAD SHX Text W.E.

AutoCAD SHX Text W.E.

AutoCAD SHX Text N67

AutoCAD SHX Text

EISENHOWER LOCK

AutoCAD SHX Text

NORTH OVERLOOK PARKING AREA

AutoCAD SHX Text

VISITORS CENTER

AutoCAD SHX Text

VISITORS CENTER RESTROOM /SECURITY BUILDING

AutoCAD SHX Text

EISENHOWER LOCK ROAD TO BARNHART ISLAND ROAD

AutoCAD SHX Text BARNHART ISLAND ROAD TO ST. ISLAND ROAD TO ST. ISLAND ROAD TO ST. ROAD TO ST. ROAD TO ST. TO ST. TO ST. ST. ST. LAWRENCE/FDR POWER PROJECT

AutoCAD SHX Text

AKC

AutoCAD SHX Text

TAO

AutoCAD SHX Text

EISENHOWER DOWNSTREAM SHIP ARRESTOR - FENDER #2

AutoCAD SHX Text

SNELL UPSTREAM SHIP ARRESTOR - FENDER #1

AutoCAD SHX Text

SNELL DOWNSTREAM SHIP ARRESTOR - FENDER #2

AutoCAD SHX Text

EISENHOWER LOCK SITE MAP SCALE: NOT TO SCALE

AutoCAD SHX Text

SNELL LOCK SITE MAP SCALE: NOT TO SCALE

AutoCAD SHX Text

PROJECT SITE MAP SCALE: NOT TO SCALE

AutoCAD SHX Text

MASSENA AREA SITE MAP SCALE: NOT TO SCALE

AutoCAD SHX Text

EISENHOWER UPSTREAM SHIP ARRESTOR - FENDER #1

AutoCAD SHX Text N

N

GENERAL NOTES:

1. THE "TYPICAL SHIP ARRESTOR BOOM AND PIN MACHINERY RECESS LAYOUT DETAIL" MAY VARY SOMEWHAT FROM LOCATION TO LOCATION.

THE DETAIL IS TO CONVEY INTENT AND BASIC EQUIPMENT LAYOUT ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY

EACH LOCATION.

2. THIS LAYOUT IS TYPICAL FOR FOUR (4) LOCATIONS, THEY ARE , EISENHOWER LOCK FENDER #1 AND FENDER #2, SNELL LOCK FENDER #1

AND FENDER #2.

3. FOR THE SCOPE OF THIS PROJECT THE MAJOR COMPONENTS THAT THE CONTRACTOR SHALL DEMOLISH AND INSTALL NEW INCLUDES

BOOM HYDRAULIC POWER UNIT (HPU), PIN HPU, BOOM CYLINDER AND PIN CYLINDER. THE LISTED EQUIPMENT COMPONENTS ARE

CONSISTENT FOR ONE FENDER ASSEMBLY(ALSO REFEREED TO AS SHIP ARRESTOR).

4. THE BOOM HPU, PIN HPU, BOOM CYLINDERS AND PIN CYLINDERS HAVE BEEN PROCURED BY THE SAINT LAWRENCE SEAWAY

DEVELOPMENT CORPORATION (SLSDC) AND WILL BE FURNISHED TO THE CONTRACTOR FOR CONTRACTOR INSTALLATION.

5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION AS OUTLINED IN THE PLANS AND SPECIFICATIONS AND INSTALLATION OF

ALL NEW EQUIPMENT AS OUTLINED IN THE PLANS AND SPECIFICATIONS.

6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL APPURTENANCES REQUIRED FOR A COMPLETE INSTALL, SUCH AS BUT NOT LIMITED

TO, CONDUIT, WIRING, JUNCTION BOXES, CABLE, PIPE FITTINGS, ETC. ALL FASTENERS, ANCHORAGE, BOLTS, NUTS, WASHERS, STRUT, ETC.

SHALL BE STAINLESS STEEL.

AutoCAD SHX Text

HPU

AutoCAD SHX Text

HPU

AutoCAD SHX Text

HYDRAULIC EQUIPMENT MACHINERY RECESS - BOOM SIDE

AutoCAD SHX Text

FENDER MACHINERY RECESS - BOOM SIDE

AutoCAD SHX Text

BOLLARD RECESS - BOOM SIDE

AutoCAD SHX Text

BRAKE CYLINDER RECESS - BOOM SIDE

AutoCAD SHX Text

BOLLARD RECESS - PIN SIDE

AutoCAD SHX Text

BRAKE CYLINDER RECESS - PIN SIDE

AutoCAD SHX Text

HYDRAULIC EQUIPMENT MACHINERY RECESS - PIN SIDE

AutoCAD SHX Text

GABLE GALLERY

AutoCAD SHX Text

GABLE GALLERY

AutoCAD SHX Text

PIN MACHINERY RECESS

AutoCAD SHX Text

QUADRANT RECESS

AutoCAD SHX Text

SHIP ARRESTOR CABLE RECESS

AutoCAD SHX Text

SHIP ARRESTOR CABLE RECESS

AutoCAD SHX Text

CENTER OF LOCK

AutoCAD SHX Text

CENTER OF LOCK

AutoCAD SHX Text

CENTER OF LOCK

AutoCAD SHX Text

LOCK WALL

AutoCAD SHX Text

LOCK WALL

AutoCAD SHX Text

LOCK WALL

AutoCAD SHX Text

LOCK WALL

AutoCAD SHX Text

LOCK WALL

AutoCAD SHX Text

LOCK WALL

AutoCAD SHX Text

LOCK WALL

AutoCAD SHX Text

PIN SIDE HPU

AutoCAD SHX Text

PIN CYLINDER

AutoCAD SHX Text

BOOM CYLINDER

AutoCAD SHX Text

BOOM SIDE HPU

AutoCAD SHX Text

SHIP ARRESTOR BOOM

AutoCAD SHX Text

4" PIPE SLEEVE FOR PIN CYLINDER HYDRAULIC LINES

AutoCAD SHX Text

TWO ELECTRICAL CONDUITS FOR LIMIT SWITCHES

AutoCAD SHX Text

3" BREAK CYLINDER VENT LINE SLEEVE

AutoCAD SHX Text

SLEEVE FOR BREAK CYLINDER HYDRAULIC LINES

AutoCAD SHX Text

THROUGH WALL SLEEVES

AutoCAD SHX Text

AREA OF WORK

AutoCAD SHX Text

AREA OF WORK

AutoCAD SHX Text

AREA OF WORK

AutoCAD SHX Text

AREA OF WORK

AutoCAD SHX Text

PIPE SLEEVE FOR BREAK CYLINDER HYDRAULIC LINES

AutoCAD SHX Text

REV.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text S

AutoCAD SHX Text Y

AutoCAD SHX Text

SLSDC

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text V

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

APPROVED:

AutoCAD SHX Text

COORDINATED:

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

OFFICE OF ENGINEERING AND MAINTENANCE

AutoCAD SHX Text

MASSENA, NEW YORK

AutoCAD SHX Text

DEVELOPMENT CORPORATION

AutoCAD SHX Text

SAINT LAWRENCE SEAWAY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OF

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SLS-370-246/2

AutoCAD SHX Text

TAO

AutoCAD SHX Text

TAO

AutoCAD SHX Text

AKC

AutoCAD SHX Text 11/01/19

AutoCAD SHX Text

TYPICAL SHIP ARRESTOR BOOM AND PIN MACHINERY RECESS PLAN SCALE: NOT TO SCALE

EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES MACHINERY RECESS PLAN

S

KEY NOTES:

1. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING HPU UNIT AND ALL ASSOCIATED HYDRAULIC AND ELECTRICAL

CONNECTIONS. CONTRACTOR SHALL DRAIN AND DISPOSE OF ALL HYDRAULIC FLUID.

2. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING WALL MOUNTED HYDRAULIC MANIFOLD AND RELATED EQUIPMENT.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING 3" BREAK CYLINDER VENT LINE. LINE SHALL BE REMOVED BACK TO BREAK

CYLINDER RECESS, VENT LINE TAKES A 90 DEGREE BEND AFTER IN ENTERS RECESS. BEND AND FIRST SECTION OF STRAIGHT PIPE SHALL

BE REMOVED.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING KLEEN VENT.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING HYDRAULIC LINES.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING HYDRAULIC CYLINDER. THE BOOM CYLINDER HAS A HEAT TRACE TAPE AND

BLANKET THAT SHALL NEED TO BE REMOVED.

7. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ELECTRIC HEATER, HEATER HOOD, AND HEATER WALL MOUNTED BRACKET.

CONTRACTOR SHALL STORE FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE ALL RELATED WIRING AND CONDUIT.

8. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING HPU CONTROL PANEL AND STORE FOR RE-INSTALLMENT. CONTRACTOR SHALL

REMOVE ALL RELATED WIRING AND CONDUIT. SEE TYPICAL PIN AND BOOM HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM FOR

ADDITIONAL DETAILS.

9. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING EQUIPMENT RELATED DISCONNECT AND ALL ASSOCIATED WIRING.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING EXISTING SPEAKER AND STORE FOR RE-INSTALLMENT. CONTRACTOR SHALL

REMOVE ALL EXISTING WIRING.

11. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL LIGHTING FIXTURES AND ASSOCIATED WIRING, CONDUITS, SWITCHES AND

JUNCTION BOXES.

12. THERE ARE THREE PROXIMITY SWITCHES FOR INDICATING BOOM POSITION. CONTRACTOR SHALL REMOVE ALL THREE PROXIMITY

SWITCHES, MOUNTING BRACKETS AND WIRING BACK TO HYDRAULIC CONTROL PANEL (HCP). CONTRACTOR SHALL STORE BRACKETS AND

PROXIMITY SWITCHES FOR RE-INSTALLMENT. SEE TYPICAL BOOM HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM FOR ADDITIONAL

DETAILS.

13. CONTRACTOR SHALL REMOVE ALL CONVENIENCE AND UTILIZATION RECEPTACLES AND ASSOCIATED WIRING,, ANCHORAGE AND CONDUITS.

14. BOOM POSITION INDICATOR SHALL REMAIN IN PLACE. TWO EXISTING 1/2" STAINLESS STEEL BREAK CYLINDER HYDRAULIC LINES TO REMAIN.

GENERAL NOTES:

1. THE CONTRACTOR SHALL BE REQUIRED TO REMOVE THE EXISTING RECESS ACCESS COVERS FOR REMOVAL AND

INSTALLATION OF NEW HPU UNITS. REFER TO RECESS COVER REMOVAL AND INSTALLATION PLAN FOR DETAILS.

2. THE "TYPICAL DEMOLITION MACHINERY RECESS PLAN - TYPICAL" IS CONSISTENT FOR ONE SHIP ARRESTOR BOOM AND PIN HPU

SYSTEM (FENDER). ACTUAL LOCATION AND RELATED ACCESSORIES IN EACH RECESS MACHINERY ROOM MAY VARY. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL EQUIPMENT INCLUDING BUT NOT LIMITED TO, PIPING, WRING, CONDUIT, ELECTRICAL DEVICES, CONTROL PANEL, JUNCTION BOXES, WALL HANGERS, LIGHTING FIXTURES, SPEAKERS, RECEPTACLES, LIGHT SWITCHES, DISCONNECTS, CABLE TRAY, UNIT HEATERS, HEATER COVER, HEATER WALL MOUNTED

BRACKET AND ANY OTHER DEVICES REQUIRED TO STRIP THE RECESS AREAS DOWN TO BARE WALLS.

3. RECESS MACHINERY ROOM AND HPU UNIT DIMENSIONS ARE SCALED AS INDICATED. OTHER RELATED EQUIPMENT MAY NOT

BE TO SCALE.

4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISPOSING OF ALL EQUIPMENT WHICH THE SLSDC DOES NOT WISH TO RETAIN.

THE SLDSC WILL COORDINATE REQUIREMENTS WITH CONTRACTOR DURING CONSTRUCTION.

5. ALL EXISTING USED AND UNUSED WALL ANCHORAGE SHALL BE REMOVED, ALL WALL PENETRATIONS FOR ANCHORAGE SHALL

BE PATCHED.

HPU CONTROL

PANEL

COMMUNICATION CABLING

HPU MOTOR HEATER CABLE

PIN PROX SWITCH CABLE (BPS1)

BOOM CYLINDER SOLENOID CABLE

COMMUNICATION WIRING TO PLC

PIN PROX SWITCH CABLE (BPS2)

SEE NOTE 1.

SEE NOTE 2.

SEE NOTE 3.

SEE NOTE 3.

SEE NOTE 4.

SEE NOTE 5.

HPU CONTROL

PANEL

COMMUNICATION CABLING

HPU MOTOR HEATER CABLE

BOOM PROX SWITCH CABLE (BPS1)

BOOM CYLINDER SOLENOID CABLE

COMMUNICATION WIRING TO PLC

BOOM PROX SWITCH CABLE (BPS2)

BOOM PROX SWITCH CABLE (BPS3)

SEE NOTE 1.

SEE NOTE 2.

SEE NOTE 3.

SEE NOTE 3.

SEE NOTE 3.

SEE NOTE 4.

SEE NOTE 5.

AutoCAD SHX Text

HYDRAULIC EQUIPMENT MACHINERY RECESS - BOOM SIDE

AutoCAD SHX Text

FENDER MACHINERY RECESS - BOOM SIDE

AutoCAD SHX Text

BOLLARD RECESS - BOOM SIDE

AutoCAD SHX Text

BRAKE CYLINDER RECESS - BOOM SIDE

AutoCAD SHX Text

BRAKE CYLINDER RECESS - PIN SIDE

AutoCAD SHX Text

HYDRAULIC EQUIPMENT MACHINERY RECESS - PIN SIDE

AutoCAD SHX Text

GABLE GALLERY

AutoCAD SHX Text

PIN MACHINERY RECESS

AutoCAD SHX Text

SHIP ARRESTOR CABLE RECESS

AutoCAD SHX Text

LT

AutoCAD SHX Text

LT

AutoCAD SHX Text

LT

AutoCAD SHX Text

UH

AutoCAD SHX Text S

AutoCAD SHX Text

HCP

AutoCAD SHX Text

PS1

AutoCAD SHX Text

PS2

AutoCAD SHX Text

PS3

AutoCAD SHX Text

JB

AutoCAD SHX Text

JB

AutoCAD SHX Text

HPU

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LT

AutoCAD SHX Text

UH

AutoCAD SHX Text S

AutoCAD SHX Text

HCP

AutoCAD SHX Text

HPU

AutoCAD SHX Text

LT

AutoCAD SHX Text

LT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SHIPS LADDER

AutoCAD SHX Text

SHIPS LADDER

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REV.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text S

AutoCAD SHX Text Y

AutoCAD SHX Text

SLSDC

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text V

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

APPROVED:

AutoCAD SHX Text

COORDINATED:

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

OFFICE OF ENGINEERING AND MAINTENANCE

AutoCAD SHX Text

MASSENA, NEW YORK

AutoCAD SHX Text

DEVELOPMENT CORPORATION

AutoCAD SHX Text

SAINT LAWRENCE SEAWAY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OF

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SLS-370-246/3

AutoCAD SHX Text

TAO

AutoCAD SHX Text

TAO

AutoCAD SHX Text

AKC

AutoCAD SHX Text 11/01/19

AutoCAD SHX Text

TYPICAL DEMOLITION MACHINERY RECESS PLAN - TYPICAL SCALE: 3/8" = 1'-0"

AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES DEMOLITION PLAN

AutoCAD SHX Text

TYPICAL PIN HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM SCALE: NOT TO SCALE

AutoCAD SHX Text 1)

AutoCAD SHX Text 2)

AutoCAD SHX Text TYPICAL PIN HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM NOTES: NOTES: : CONTRACTOR SHALL REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY SHALL REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY SHALL REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY REMOVE AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY AND PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY PULL MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CONTROL WIRING CABLE BACK TO CABLE GALLERY CONTROL WIRING CABLE BACK TO CABLE GALLERY WIRING CABLE BACK TO CABLE GALLERY WIRING CABLE BACK TO CABLE GALLERY CABLE BACK TO CABLE GALLERY CABLE BACK TO CABLE GALLERY BACK TO CABLE GALLERY BACK TO CABLE GALLERY TO CABLE GALLERY TO CABLE GALLERY CABLE GALLERY CABLE GALLERY GALLERY GALLERY CABLE TRAY LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR TRAY LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR TRAY LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR LOCATED JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR JUST OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR CONTROL WIRING CABLE SHALL BE SECURED FOR CONTROL WIRING CABLE SHALL BE SECURED FOR WIRING CABLE SHALL BE SECURED FOR WIRING CABLE SHALL BE SECURED FOR CABLE SHALL BE SECURED FOR CABLE SHALL BE SECURED FOR SHALL BE SECURED FOR SHALL BE SECURED FOR BE SECURED FOR BE SECURED FOR SECURED FOR SECURED FOR FOR FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE PIN CYLINDER SOLENOID CABLE. CONTRACTOR SHALL REMOVE PIN CYLINDER PROXIMITY SWITCH CABLE AND STORE FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE HPU MOTOR HEATER CABLE. CONTRACTOR SHALL REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY SHALL REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY SHALL REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY REMOVE AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY AND PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY PULL THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY CABLES BACK TO CABLE GALLERY CABLE TRAY CABLES BACK TO CABLE GALLERY CABLE TRAY BACK TO CABLE GALLERY CABLE TRAY BACK TO CABLE GALLERY CABLE TRAY TO CABLE GALLERY CABLE TRAY TO CABLE GALLERY CABLE TRAY CABLE GALLERY CABLE TRAY CABLE GALLERY CABLE TRAY GALLERY CABLE TRAY GALLERY CABLE TRAY CABLE TRAY CABLE TRAY TRAY TRAY LOCATED JUST OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE JUST OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE JUST OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE COMMUNICATION CABLES, TWO ETHERNET AND ONE COMMUNICATION CABLES, TWO ETHERNET AND ONE CABLES, TWO ETHERNET AND ONE CABLES, TWO ETHERNET AND ONE TWO ETHERNET AND ONE TWO ETHERNET AND ONE ETHERNET AND ONE ETHERNET AND ONE AND ONE AND ONE ONE ONE TWISTED PAIR. CABLES SHALL BE SECURED FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, CONDUIT, CABLE TRAY, ANCHORAGE, CONDUIT, CABLE TRAY, ANCHORAGE, CABLE TRAY, ANCHORAGE, CABLE TRAY, ANCHORAGE, TRAY, ANCHORAGE, TRAY, ANCHORAGE, ANCHORAGE, ANCHORAGE, FITTINGS AND ANY OTHER RELATED EQUIPMENT ASSOCIATED WITH HPU CONTROL PANEL CIRCUITS.

AutoCAD SHX Text 3)

AutoCAD SHX Text 4)

AutoCAD SHX Text 5)

AutoCAD SHX Text

TYPICAL BOOM HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM SCALE: NOT TO SCALE

AutoCAD SHX Text 1)

AutoCAD SHX Text 2)

AutoCAD SHX Text TYPICAL BOOM HPU CONTROL PANEL DEMOLITION WIRING DIAGRAM NOTES: NOTES: : CONTRACTOR SHALL REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE SHALL REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE SHALL REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE REMOVE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE MULTI-CONDUCTOR CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE CONTROL WIRING CABLE BACK TO CABLE GALLERY CABLE WIRING CABLE BACK TO CABLE GALLERY CABLE WIRING CABLE BACK TO CABLE GALLERY CABLE CABLE BACK TO CABLE GALLERY CABLE CABLE BACK TO CABLE GALLERY CABLE BACK TO CABLE GALLERY CABLE BACK TO CABLE GALLERY CABLE TO CABLE GALLERY CABLE TO CABLE GALLERY CABLE CABLE GALLERY CABLE CABLE GALLERY CABLE GALLERY CABLE GALLERY CABLE CABLE CABLE TRAY OUTSIDE OF RECESS. CONTROL WIRING CABLE SHALL BE SECURED FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE BOOM CYLINDER SOLENOID CABLE. CONTRACTOR SHALL REMOVE PROXIMITY SWITCH CABLE. CONTRACTOR SHALL REMOVE HPU MOTOR HEATER CABLE CONTRACTOR SHALL REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE SHALL REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE SHALL REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE REMOVE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE THREE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE COMMUNICATION CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE CABLES BACK TO CABLE GALLERY CABLE TRAY OUTSIDE BACK TO CABLE GALLERY CABLE TRAY OUTSIDE BACK TO CABLE GALLERY CABLE TRAY OUTSIDE TO CABLE GALLERY CABLE TRAY OUTSIDE TO CABLE GALLERY CABLE TRAY OUTSIDE CABLE GALLERY CABLE TRAY OUTSIDE CABLE GALLERY CABLE TRAY OUTSIDE GALLERY CABLE TRAY OUTSIDE GALLERY CABLE TRAY OUTSIDE CABLE TRAY OUTSIDE CABLE TRAY OUTSIDE TRAY OUTSIDE TRAY OUTSIDE OUTSIDE OUTSIDE OF RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES RECESS. THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES THERE ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES ARE THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES THREE COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES COMMUNICATION CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES CABLES, TWO ETHERNET AND ONE TWISTED PAIR. CABLES TWO ETHERNET AND ONE TWISTED PAIR. CABLES TWO ETHERNET AND ONE TWISTED PAIR. CABLES ETHERNET AND ONE TWISTED PAIR. CABLES ETHERNET AND ONE TWISTED PAIR. CABLES AND ONE TWISTED PAIR. CABLES AND ONE TWISTED PAIR. CABLES ONE TWISTED PAIR. CABLES ONE TWISTED PAIR. CABLES TWISTED PAIR. CABLES TWISTED PAIR. CABLES PAIR. CABLES PAIR. CABLES CABLES CABLES SHALL BE SECURED FOR RE-INSTALLMENT. CONTRACTOR SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, SHALL REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, REMOVE ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, ALL RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RELATED DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, DISCONNECTS, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, RECEPTACLES, CONDUIT, CABLE TRAY, ANCHORAGE, CONDUIT, CABLE TRAY, ANCHORAGE, CONDUIT, CABLE TRAY, ANCHORAGE, CABLE TRAY, ANCHORAGE, CABLE TRAY, ANCHORAGE, TRAY, ANCHORAGE, TRAY, ANCHORAGE, ANCHORAGE, ANCHORAGE, FITTINGS AND ANY OTHER RELATED EQUIPMENT ASSOCIATED WITH HPU CONTROL PANEL CIRCUITS.

AutoCAD SHX Text 3)

AutoCAD SHX Text 4)

AutoCAD SHX Text 5)

AutoCAD SHX Text 6)

6)

KEY NOTES:

1. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SLSDC SUPPLIED HPU UNIT AS PER MANUFACTURERS WRITTEN INSTRUCTIONS.

INSTALLATION REQUIREMENTS INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING:

1.1. HPU SHALL BE SECURELY ANCHORED TO CONCRETE FLOOR.

1.2. PUMP MOTOR BRANCH CIRCUIT

1.3. MOTOR HEATER BRANCH CIRCUIT

1.4. BOOM/PIN SOLENOID WIRING

1.5. INITIAL FILL OF HYDRAULIC FLUID, TANK IS SHIPPED EMPTIED.

1.6. ALL HYDRAULIC LINES INTERCONNECTIONS (REFER TO BOOM AND PIN HYDRAULIC SCHEMATICS FOR ADDITIONAL DETAILS)

2. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SLSDC SUPPLIED 3" BREAK CYLINDER VENT LINE VALVE.

3. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING NEW 3" BREAK CYLINDER VENT LINE FROM HPU UNIT TO CONNECTION POINT IN

BREAK CYLINDER RECESS. VENT LINE TAKES A 90 DEGREE BEND AFTER IT ENTERS BREAK CYLINDER RECESS. BEND AND FIRST SECTION

OF STRAIGHT PIPE SHALL BE REPLACED BY CONTRACTOR. CONTRACTOR SHALL PAINT PIPE AS REQUIRED BY SLSDC.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SLSDC SUPPLIED PIN CYLINDER. CONTRACTOR SHALL COORDINATE INSTALLATION

AND ALIGNMENT REQUIREMENTS WITH SLSDC PRIOR TO DOING ANY WORK.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING SLSDC SUPPLIED BOOM CYLINDER. CONTRACTOR SHALL COORDINATE

INSTALLATION AND ALIGNMENT REQUIREMENTS WITH SLSDC PRIOR TO DOING ANY WORK.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR NEW HYDRAULIC LINES FROM BOOM MANIFOLD ON NEW HPU TO BOOM CYLINDER. HYDRAULIC

TUBING, HYDRAULIC HOSE, MOUNTING AND ROUTING SHALL BE COORDINATED WITH SLSDC PRIOR TO DOING ANY WORK. ALL REQUIRED

FITTINGS, ANCHORAGE AND FASTENERS SHALL BE STAINLESS STEEL.

7. CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING EXISTING HYDRAULIC LINES TO RECESS CONCRETE WALL. CONTRACTOR SHALL

INSTALL STAINLESS STEEL STRUT EVERY SIX FEET AND ANCHOR HYDRAULIC TUBING TO STRUT.

8. CONTRACTOR SHALL CONNECT NEW HYDRAULIC LINES FROM HPU MANIFOLD TO EXISTING HYDRAULIC LINES IN THIS AREA. CONTRACTOR

SHALL MODIFY AS NEEDED.

GENERAL NOTES:

1. ALL ANCHORS, FASTENERS, STRUT, BOLTS, WASHERS SCREWS AND ANY OTHER MATERIAL USED FOR SECURING EQUIPMENT

IN THE RECESS AREAS SHALL BE STAINLESS STEEL.

2. CONTRACTOR SHALL INSTALL ALL EQUIPMENT AS PER MANUFACTURERS WRITTEN INSTRUCTIONS.

3. THE "TYPICAL PROPOSED MACHINERY RECESS MECHANICAL PLAN" IS INTENDED TO CONVEY INTENT ONLY FOR A TYPICAL

BOOM AND PIN RECESS INSTALL. ACTUAL EQUIPMENT LOCATIONS MAY VARY, INCLUDING BUT NOT LIMITED TO, INCIDENTAL

DEVICES, SUCH AS, RECEPTACLES, SWITCHES, DISCONNECTS, LIGHT FIXTURES, ETC.

4. CONTRACTOR SHALL VERIFY FINAL EQUIPMENT LOCATION WITH SLSDC PRIOR TO DOING ANY WORK.

AutoCAD SHX Text

FENDER MACHINERY RECESS - BOOM SIDE

AutoCAD SHX Text

BOLLARD RECESS - BOOM SIDE

AutoCAD SHX Text

BRAKE CYLINDER RECESS - BOOM SIDE

AutoCAD SHX Text

BRAKE CYLINDER RECESS - PIN SIDE

AutoCAD SHX Text

GABLE GALLERY

AutoCAD SHX Text

PIN MACHINERY RECESS

AutoCAD SHX Text

SHIP ARRESTOR CABLE RECESS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SHIPS LADDER

AutoCAD SHX Text

SHIPS LADDER

AutoCAD SHX Text

AutoCAD SHX Text

HPU

AutoCAD SHX Text

AutoCAD SHX Text

HPU

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

STATION MANIFOLD - BOOM ONLY

AutoCAD SHX Text

ANCHOR POINT- TYPICAL

AutoCAD SHX Text

3" BREAK CYLINDER VENT

AutoCAD SHX Text

STATION MANIFOLD - PIN ONLY

AutoCAD SHX Text

STATION MANIFOLD - PIN ONLY

AutoCAD SHX Text

THERMOSTAT

AutoCAD SHX Text

RETURN FILTER

AutoCAD SHX Text

KLEEN VENT

AutoCAD SHX Text

HEATER

AutoCAD SHX Text

PUMP MOTOR

AutoCAD SHX Text

ELECTRICAL ENCLOSURE

AutoCAD SHX Text

REV.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text S

AutoCAD SHX Text Y

AutoCAD SHX Text

SLSDC

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text V

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

APPROVED:

AutoCAD SHX Text

COORDINATED:

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

OFFICE OF ENGINEERING AND MAINTENANCE

AutoCAD SHX Text

MASSENA, NEW YORK

AutoCAD SHX Text

DEVELOPMENT CORPORATION

AutoCAD SHX Text

SAINT LAWRENCE SEAWAY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OF

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SLS-370-246/4

AutoCAD SHX Text

TAO

AutoCAD SHX Text

TAO

AutoCAD SHX Text

AKC

AutoCAD SHX Text 11/01/19

AutoCAD SHX Text

TYPICAL PROPOSED MACHINERY RECESS MECHANICAL PLAN SCALE: 3/8" = 1'-0"

AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES PROPOSED MECHANICAL PLAN

TYPICAL HYDRAULIC POWER UNIT ISOMETRIC AND PLAN VIEW SCALE: NONE

S

KEY NOTES:

1. CONTRACTOR SHALL BE RESPONSIBLE FOR RE-INSTALLING HYDRAULIC UNIT CONTROL PANEL. REFER TO HPU CONTROL PANEL WIRING

DIAGRAMS FOR ADDITIONAL DETAILS.

2. CONTRACTOR SHALL PROVIDE STAINLESS STEEL MOTOR DISCONNECT, 7.5HP RATED, 480V, 3 PHASE.

3. CONTRACTOR SHALL PROVIDE STAINLESS STEEL MOTOR HEATER DISCONNECT, VERIFY SIZE WITH MANUFACTURE.

4. CONTRACTOR SHALL ADJUST PROXIMITY SWITCHES AS NEEDED AFTER NEW PIN CYLINDER IS INSTALLED.

5. CONTRACTOR SHALL MODIFY EXISTING HEAT TRACE BRANCH CIRCUIT FOR BOOM CYLINDER. CONTRACTOR SHALL INSTALL BRANCH

CIRCUIT IN SCHEDULE 80 PVC CONDUIT AND PROVIDE WEATHER PROOF RECEPTACLE.

6. CONTRACTOR SHALL PROVIDE GENERAL PURPOSE WEATHERPROOF RECEPTACLE. CONTRACTOR SHALL INSTALL BRANCH CIRCUIT IN

SCHEDULE 80 PVC CONDUIT.

7. CONTRACTOR SHALL SUPPLY 60AMP, 480V, THREE PHASE STAINLESS STEEL DISCONNECT TO REPLACE EXISTING WELDING DISCONNECT.

CONTRACTOR SHALL REUSE EXISTING WELDING DISCONNECT BRANCH CIRCUIT. BRANCH CIRCUIT SHALL BE INSTALLED IN SCHEDULE 80

PVC CONDUIT. FINAL LOCATION TO BE FIELD DETERMINED WITH SLSDC.

8. CONTRACTOR SHALL INSTALL NEW LIGHTING IN RECESS INCLUDING ALL LIGHTING FIXTURES, SCHEDULE 80 PVC CONDUIT AND BOXES, WIRING AND TOGGLE SWITCHES. CONTRACTOR SHALL REUSE EXISTING LIGHTING FIXTURE BRANCH CIRCUIT WHICH SERVES THE RECESS.

LIGHTING FIXTURE SHALL BE C-LITE C-VTB-19L-40K OR EQUAL.

9. CONTRACTOR SHALL INSTALL NEW TOGGLE SWITCH, SCHEDULE 80 PVC CONDUIT AND WIRING FOR EXISTING BREAK CYLINDER LIGHTING

CIRCUIT.

10. CONTRACTOR SHALL RE-INSTALL EXISTING PROXIMITY SWITCHES. CONTRACTOR SHALL INSTALL ALL WIRING IN SCHEDULE 80 PVC

CONDUIT. CONTRACTOR SHALL REFINISH AND PAINT PROXIMITY SWITCH MOUNTING BRACKETS.

GENERAL NOTES:

1. ALL FITTINGS, ANCHORS, FASTENERS, STRUT, BOLTS, WASHERS SCREWS. ETC.INSTALLED IN THE RECESS AREAS SHALL BE

STAINLESS STEEL.

2. CONTRACTOR SHALL INSTALL ALL EQUIPMENT AS PER MANUFACTURERS WRITTEN INSTRUCTIONS.

3. THE "TYPICAL PROPOSED MACHINERY RECESS ELECTRICAL PLAN" IS INTENDED TO CONVEY INTENT ONLY FOR A TYPICAL

BOOM AND PIN RECESS INSTALL. ACTUAL EQUIPMENT LOCATIONS MAY VARY, INCLUDING BUT NOT LIMITED TO, INCIDENTAL

DEVICES, SUCH AS, RECEPTACLES, SWITCHES, DISCONNECTS, LIGHT FIXTURES, ETC.

4. CONTRACTOR SHALL VERIFY FINAL EQUIPMENT LOCATION WITH SLSDC PRIOR TO DOING ANY WORK.

5. ALL CONDUITS AND FITTINGS SHALL BE SCHEDULE 80 PVC.

6. ALL WIRING SHALL BE CABLE TRAY RATED.

7. ALL CONDUIT RUNS SHALL BE SECURED TO WALL MOUNTED STAINLESS STEEL STRUT. CONTRACTOR SHALL REVIEW CONDUIT

PLAN WITH SLSDC PRIOR TO DOING ANY WORK.

8. ALL WORK SHALL BE IN COMPLIANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE.

HPU CONTROL

PANEL

COMMUNICATION CABLING

HPU MOTOR HEATER CABLE

PIN PROX SWITCH CABLE (BPS1)

BOOM CYLINDER SOLENOID CABLE

COMMUNICATION WIRING TO PLC

PIN PROX SWITCH CABLE (BPS2)

SEE NOTE 1.

SEE NOTE 2.

SEE NOTE 3.

SEE NOTE 3.

SEE NOTE 4.

SEE NOTE 5.

HPU CONTROL

PANEL

COMMUNICATION CABLING

HPU MOTOR HEATER CABLE

BOOM PROX SWITCH CABLE (BPS1)

BOOM CYLINDER SOLENOID CABLE

COMMUNICATION WIRING TO PLC

BOOM PROX SWITCH CABLE (BPS2)

BOOM PROX SWITCH CABLE (BPS3)

SEE NOTE 1.

SEE NOTE 2.

SEE NOTE 3.

SEE NOTE 3.

SEE NOTE 3.

SEE NOTE 4.

SEE NOTE 5.

AutoCAD SHX Text

PS1

AutoCAD SHX Text

PS2

AutoCAD SHX Text

PS3

AutoCAD SHX Text

AutoCAD SHX Text

FENDER MACHINERY RECESS - BOOM SIDE

AutoCAD SHX Text

BOLLARD RECESS - BOOM SIDE

AutoCAD SHX Text

BRAKE CYLINDER RECESS - BOOM SIDE

AutoCAD SHX Text

BRAKE CYLINDER RECESS - PIN SIDE

AutoCAD SHX Text

GABLE GALLERY

AutoCAD SHX Text

PIN MACHINERY RECESS

AutoCAD SHX Text

SHIP ARRESTOR CABLE RECESS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HPU

AutoCAD SHX Text

HPU

AutoCAD SHX Text

LT

AutoCAD SHX Text

LT

AutoCAD SHX Text

LT

AutoCAD SHX Text

LT

AutoCAD SHX Text

LT

AutoCAD SHX Text

HCP

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HCP

AutoCAD SHX Text

AutoCAD SHX Text

LT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LT

AutoCAD SHX Text

LT

AutoCAD SHX Text

LT

AutoCAD SHX Text

REV.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text S

AutoCAD SHX Text Y

AutoCAD SHX Text

SLSDC

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text V

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

APPROVED:

AutoCAD SHX Text

COORDINATED:

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

OFFICE OF ENGINEERING AND MAINTENANCE

AutoCAD SHX Text

MASSENA, NEW YORK

AutoCAD SHX Text

DEVELOPMENT CORPORATION

AutoCAD SHX Text

SAINT LAWRENCE SEAWAY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OF

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SLS-370-246/5

AutoCAD SHX Text

TAO

AutoCAD SHX Text

TAO

AutoCAD SHX Text

AKC

AutoCAD SHX Text 11/01/19

AutoCAD SHX Text

TYPICAL PROPOSED MACHINERY RECESS ELECTRICAL PLAN SCALE: 3/8" = 1'-0"

AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES PROPOSED ELECTRICAL PLAN

AutoCAD SHX Text

TYPICAL PIN HPU CONTROL PANEL WIRING DIAGRAM SCALE: NOT TO SCALE

AutoCAD SHX Text 1)

AutoCAD SHX Text 2)

AutoCAD SHX Text TYPICAL PIN HPU CONTROL PANEL WIRING DIAGRAM NOTES: NOTES: : CONTRACTOR SHALL RE-INSTALL MULTI-CONDUCTOR CONTROL WIRING CABLE. CONTRACTOR SHALL INSTALL PIN CYLINDER SOLENOID CABLE. CONTRACTOR SHALL RE-INSTALL PIN CYLINDER PROXIMITY SWITCH CABLE. CONTRACTOR SHALL INSTALL HPU MOTOR HEATER CABLE. CONTRACTOR SHALL RE-INSTALL THREE COMMUNICATION CABLES. ALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL ALL CONDUIT SHALL BE SECURED TO WALL ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT SHALL BE SECURED TO WALL CONDUIT SHALL BE SECURED TO WALL SHALL BE SECURED TO WALL SHALL BE SECURED TO WALL BE SECURED TO WALL BE SECURED TO WALL SECURED TO WALL SECURED TO WALL TO WALL TO WALL WALL WALL MOUNTED STAINLESS STEEL STRUT.

AutoCAD SHX Text 3)

AutoCAD SHX Text 4)

AutoCAD SHX Text 5)

AutoCAD SHX Text

TYPICAL BOOM HPU CONTROL PANEL BOOM WIRING DIAGRAM SCALE: NOT TO SCALE

AutoCAD SHX Text 6)

AutoCAD SHX Text 1)

AutoCAD SHX Text 2)

AutoCAD SHX Text TYPICAL BOOM HPU CONTROL PANEL WIRING DIAGRAM NOTES: NOTES: : CONTRACTOR SHALL RE-INSTALL MULTI-CONDUCTOR CONTROL WIRING CABLE. CONTRACTOR SHALL INSTALL BOOM CYLINDER SOLENOID CABLE. CONTRACTOR SHALL RE-INSTALL BOOM CYLINDER PROXIMITY SWITCH CABLE. CONTRACTOR SHALL INSTALL HPU MOTOR HEATER CABLE. CONTRACTOR SHALL RE-INSTALL THREE COMMUNICATION CABLES. ALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CABLES SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SHALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL BE INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL INSTALLED IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL IN SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL SCHEDULE 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL 80 PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL PVC CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT. ALL CONDUIT SHALL BE SECURED TO WALL ALL CONDUIT SHALL BE SECURED TO WALL ALL CONDUIT SHALL BE SECURED TO WALL CONDUIT SHALL BE SECURED TO WALL CONDUIT SHALL BE SECURED TO WALL SHALL BE SECURED TO WALL SHALL BE SECURED TO WALL BE SECURED TO WALL BE SECURED TO WALL SECURED TO WALL SECURED TO WALL TO WALL TO WALL WALL WALL MOUNTED STAINLESS STEEL STRUT.

AutoCAD SHX Text 3)

AutoCAD SHX Text 4)

AutoCAD SHX Text 5)

6)

150 GALLON

B

A

100%

M

P

B

A

100%

S

P

1500 PSI

SET AT

PDB

XDB

TDB

1000 PSI

SET AT

SZ80

P

T

A1 B1

P

B3A2 B2 A3

T

P T

SET AT

GA

P a

A

T

B b

P a

A

T

B b a

P

A

T

B b

L2

L1

AutoCAD SHX Text

REV.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text S

AutoCAD SHX Text Y

AutoCAD SHX Text

SLSDC

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text V

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

APPROVED:

AutoCAD SHX Text

COORDINATED:

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

OFFICE OF ENGINEERING AND MAINTENANCE

AutoCAD SHX Text

MASSENA, NEW YORK

AutoCAD SHX Text

DEVELOPMENT CORPORATION

AutoCAD SHX Text

SAINT LAWRENCE SEAWAY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OF

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SLS-370-246/6

AutoCAD SHX Text

TAO

AutoCAD SHX Text

TAO

AutoCAD SHX Text

AKC

AutoCAD SHX Text 11/01/19

AutoCAD SHX Text

BOOM HPU HYDRAULIC SCHEMATIC SCALE: NONE

AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES HYDRAULIC SCHEMATIC BOOM HPU

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

JUNCTION

AutoCAD SHX Text

BOX

AutoCAD SHX Text

LIMIT OF POWER UNIT

AutoCAD SHX Text

Q1 = 6 GPM

AutoCAD SHX Text p1 = 1500 PSI

AutoCAD SHX Text

P = 7-1/2 HP

AutoCAD SHX Text n = 1800 RPM

AutoCAD SHX Text

%%UCONNECTIONS

AutoCAD SHX Text

%%UBRAKE CYLINDER

AutoCAD SHX Text P1

AutoCAD SHX Text P2

AutoCAD SHX Text

Q2 = 6 GPM

AutoCAD SHX Text p2 = 1000 PSI

AutoCAD SHX Text

AutoCAD SHX Text

SZ10

AutoCAD SHX Text

AutoCAD SHX Text

SZ10

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SZ10

AutoCAD SHX Text

AutoCAD SHX Text

SZ10

AutoCAD SHX Text

AutoCAD SHX Text R1

AutoCAD SHX Text B1

AutoCAD SHX Text R2

AutoCAD SHX Text B2

AutoCAD SHX Text

%%UBOOM CYLINDER

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 310.1

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text T

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text T

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text T

AutoCAD SHX Text 550.1

AutoCAD SHX Text 550.2

AutoCAD SHX Text

AutoCAD SHX Text

BR2

AutoCAD SHX Text

BR1

AutoCAD SHX Text T2

AutoCAD SHX Text

LOOSE

AutoCAD SHX Text

SUPPLY

AutoCAD SHX Text

TO T.P.#130

AutoCAD SHX Text P,T,A,B,A1,B1,A2,B2,A3,B3 =

AutoCAD SHX Text

1-1/16-12 SAE (-12)

AutoCAD SHX Text

BR1,BR2 =

AutoCAD SHX Text

3/4-16 SAE (-8)

AutoCAD SHX Text T2 =

AutoCAD SHX Text 3" 150lb. ANSI FLG.

AutoCAD SHX Text

SZ20

AutoCAD SHX Text

AutoCAD SHX Text

FILL PORT

AutoCAD SHX Text

AutoCAD SHX Text

SZ15

AutoCAD SHX Text

5 GAL.

AutoCAD SHX Text 310.2

AutoCAD SHX Text 313.1

AutoCAD SHX Text 313.2

AutoCAD SHX Text

GA =

AutoCAD SHX Text

9/16-18 SAE (-6)

AutoCAD SHX Text P1, P2 =

AutoCAD SHX Text

7/8-14 SAE (-10)

AutoCAD SHX Text S =

AutoCAD SHX Text

1 5/16 SAE (-16)

AutoCAD SHX Text

%%UCONNECTIONS

AutoCAD SHX Text 34 x 0.065

AutoCAD SHX Text 1 x 0.065

AutoCAD SHX Text 1 x 0.065

AutoCAD SHX Text

PDB, TDB =

AutoCAD SHX Text G1/2

AutoCAD SHX Text

XDB =

G1/4

150 GALLON

B

A

100%

M

S

P

B

A

100%

250 PSI

P

T

A B

P

T

P T

SET ATSET AT

1000 PSI

S

P

B

A

100%

SZ80

P a

A

T

B b

P a

A

T

B b

P

A1

T

B1

P

A2 B2

T

GA

P T

SET ATSET AT

a

P

A

T

B b

L2

L1

Tech position

Part number

Part number description

Manufacturer

Quantity per assembly

10 R978064885 OIL RESERVOIR 43AHAG-17158-1 Bosch Rexroth 1

20 R978907302 DMIC BVAL-0750S-4321-AZZA DMIC 1

40 R978011653 ENCLOSURE C-SD12126SS HOFFMAN 4X Hoffman 1

60 R978804856 THERMOMETER BIMET PUA31-14 WIKA 33X0278 WIKA 1

70 R901404478 AIR FILTER KVEU005PWWT50A1 Parker 1

80 R901299368 MAGNETIC SEPARATOR HD-7 X 14"-2" NPT/SS SPS Rockford 1

90 R978802712 CHROMA HEATER ELEM 1PUA32-10/120V Chromalox 1

100 R978888625 TEMP SW 2PUA31-30-00 B402-120-1271 Power Associates 1

110 R978800007 SIGHT GLASS CS3615-244910 LDI Industries 2

120 R978887096 LHA-SEC-100-3-100-RV3 SUCT STRAINER

Donaldson Industrial

Hydraulics

130 R978007870 DMIC BVAL-3000AA-4321-AZZA DMIC 1

140 R928041276

10TEN0100-PWR10A00-P2,2-M-U9

Bosch Rexroth 1

141 R928028409 WE-1SP-M12X1 Bosch Rexroth 1

150 R928049174 BFSK80-2X/H3V3-M-S-CV Bosch Rexroth 1

160 R901269280 ABZMS-41-1X/0800/M2/AC-K14 Bosch Rexroth 1

200 R978064664 MOTOR AC W22-7.5HP-213TC-208-& Bosch Rexroth 1

R978807567 CPL HUB L100 SPL SAE A SPL 33-20

Lovejoy

R978889102 CPL INSERT L099/100 HYTREL

Lovejoy

R978802780 CPL HUB L100 BORED 1 3/8X5/16 KEY 33-20

Lovejoy

220 9510290146 AZPFF-12-014/014RRR1212MB-S0516 Bosch Rexroth 1

250 R928030729

245LEN0063-PWR10A00-V5,0-M-U4

Bosch Rexroth 1

260 R901454073 S 20 A05-1X/450J3/12 Bosch Rexroth 1

270 R978006001

PARKER SH6-63-T12 QUICK DISCONNECT

Parker 1

280 R901454180 S 15 A05-1X/450J3/12 Bosch Rexroth 1

290 R901524046 DB 10 G3-5X/100X Bosch Rexroth 1

310 R978060162 PRESSURE GAUGE 233.53 4 3000PSI 7/1& WIKA 2

400 R978028975 F22T124GVPWK STR SECTION WIREWAY HOFFMAN Hoffman 1

500 R978913414 BM10PN-1X/03D3-12RCR Bosch Rexroth 1

510 R900425162 DBDA 10 K1X/200 Bosch Rexroth 1

520 R901350265 4WMM 10 E5X//M Bosch Rexroth 1

530 R900597186 4WE 10 E3X/CW110N9K4 Bosch Rexroth 1

540 R901350265 4WMM 10 E5X//M Bosch Rexroth 1

550 R987330729 BALL VALVE BVH-0500S-2211-AZZA DMIC 2

AutoCAD SHX Text

REV.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text S

AutoCAD SHX Text Y

AutoCAD SHX Text

SLSDC

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text V

AutoCAD SHX Text O

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text

APPROVED:

AutoCAD SHX Text

COORDINATED:

AutoCAD SHX Text

RECOMMENDED:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

OFFICE OF ENGINEERING AND MAINTENANCE

AutoCAD SHX Text

MASSENA, NEW YORK

AutoCAD SHX Text

DEVELOPMENT CORPORATION

AutoCAD SHX Text

SAINT LAWRENCE SEAWAY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BY

AutoCAD SHX Text

OF

AutoCAD SHX Text

AS NOTED

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SLS-370-246/7

AutoCAD SHX Text

TAO

AutoCAD SHX Text

TAO

AutoCAD SHX Text

AKC

AutoCAD SHX Text 11/01/19

AutoCAD SHX Text

PIN HPU HYDRAULIC SCHEMATIC SCALE: NONE

AutoCAD SHX Text EISENHOWER AND SNELL LOCKS SHIP ARRESTOR HYDRAULIC POWER UNITS AND BOOM/PIN CYLINDER UPGRADES HYDRAULIC SCHEMATIC PIN HPU

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SZ10

AutoCAD SHX Text

AutoCAD SHX Text

SZ10

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SZ10

AutoCAD SHX Text

AutoCAD SHX Text

SZ10

AutoCAD SHX Text

JUNCTION

AutoCAD SHX Text

BOX

AutoCAD SHX Text

BR2

AutoCAD SHX Text

BR1

AutoCAD SHX Text

LIMIT OF POWER UNIT

AutoCAD SHX Text

Q1 = 6 GPM

AutoCAD SHX Text p1 = 1000 PSI

AutoCAD SHX Text

P = 7-1/2 HP

AutoCAD SHX Text n = 1800 RPM

AutoCAD SHX Text

%%UCONNECTIONS

AutoCAD SHX Text

%%UBRAKE CYLINDER

Auto…

This is the start of the file's text. The full file is on GovTribe.