642-21-117 Building 5 Drawing Set 02122021.pdf
PDF 5 MB Posted
- Attached to
- Z2DA--642-21-117 | D/B Building 5 Trailer Replacement Federal contract opportunity
- Solicitation number
- 36C24421R0050
About this file
This document package includes construction drawings and a federal contract opportunity solicitation. The construction drawings are for a Design/Build project to replace an existing trailer with a new single-story wood framed building at the Philadelphia VA Medical Center. The drawings show demolition plans, floor plans, and general notes for utilities and construction.
The related federal contract opportunity solicitation is seeking a Service Disabled Veteran Owned Small Business to provide design and construction services for the project. The contractor will design and build a 1,800 square foot slab on grade building with vinyl siding, mechanical/HVAC, electrical, and plumbing systems. Pre-engineered building systems are also acceptable. The contractor must investigate site conditions and provide fully developed construction documents. The estimated release date for the solicitation is April 10, 2021. The contracting agency is the Department of Veterans Affairs Veterans Health Administration VISN 4.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24421R0050_1.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF VETERANS AFFAIRS
CORPORAL MICHAEL J. CRESCENZ MEDICAL CENTER
BUILDING NO.5 TRAILER REPLACEMENT
VICINITY MAP
N O
RTH
DRAWING LIST
GENERAL
G-100 COVER SHEET
G-200 GENERAL NOTES
SITE PLAN
G-300 EXISTING UNDERGROUND UTILITIES MAPPING
ARCHITECTURAL
AD-100 DEMOLITION PLAN
A-100 FLOOR PLANS (1 OF 2)
A-101 FLOOR PLANS (2 OF 2)
AutoCAD SHX Text
OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT
AutoCAD SHX Text
U.S. DEPARTMENT OF VETERANS AFFAIRS
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
BUILDING 5 TRAILER REPLACEMENT
AutoCAD SHX Text
BUILDING NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text G-100
AutoCAD SHX Text
DWG. OF
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
CORPORAL MICHAEL J. CRESCENZ VAMC 3900 WOODLAND AVE, PHILADELPHIA, PA 19104
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FEBRUARY 2021
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
YS
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
APPROVED: PROJECT DIRECTOR
AutoCAD SHX Text
KG
GENERAL NOTES - EXTERIOR AND UTILITY TRENCH PATCH
1. MATERIAL AND COMPACTION REQUIREMENTS FOR PIPE BEDDING/SHADING SHALL
BE IN ACCORDANCE WITH THE SPECIFICATIONS FOR THE APPLICABLE UTILITY PIPE.
2. TRENCH BACKFILL SHALL COMMENCE 1 FOOT [305MM] ABOVE THE TOP OF PIPE
AND SHALL BE PER SECTION XXX.
3. BACKFILL COMPACTION REQUIREMENTS SHALL BE PER SECTION XXX.
4. THE 1 FOOT [305MM] TRENCH "SHOULDER" AREAS SHALL BE DELETED FOR TYPE 2
TRENCHES.
5. ABC SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION XXX.
6. PORTLAND CEMENT CONCRETE SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS OF SECTION XXX.
7. ASPHALTIC TACK MATERIAL SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS
OF SECTION XXX.
8. ASPHALTIC CONCRETE SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF
SECTION XXX FOR THE TYPE SPECIFIED.
9. BITUMINOUS SURFACE TREATMENT (CHIP SEAL) SHALL BE IN ACCORDANCE WITH
THE REQUIREMENTS OF SECTION XXX FOR THE TYPE SPECIFIED.
10. LOAD TRANSFER DOWELS FOR JOINTS TRANSVERSE TO THE ROADWAY
CENTERLINE SHALL BE SMOOTH STEEL DOWELS IN ACCORDANCE WITH THE
REQUIREMENTS OF SECTION XXX. DOWELS SHALL BE SIZED AND SPACED AS
FOLLOWS:
PCCP THICKNESS DOWEL SIZE DOWEL LENGTH DOWEL SPACING
6" [150MM] #5 [NO. 16] 12" [305MM] 18" [455MM]
7" [180MM] #6 [NO. 19] 15" [380MM] 15" [380MM]
8" [180MM] #8 [NO. 19] 15" [380MM] 12" [305MM]
10" [180MM] #10 [NO. 19] 15" [380MM] 12" [305MM]
11. DEFORMED TIE BARS SHALL BE USED IN TRENCH PATCHES LONGITUDINAL TO THE
ROADWAY CENTERLINE WHEN THE TRENCH LENGTH IS GREATER THAN 50 FEET
[15240MM]. TIE BARS SHALL BE 24 INCHES [610MM] LONG. DEFORMED #4 [NO. 13]
BARS FOR PCCP LESS THAN 8 INCHES [205MM] THICK AND #5 [NO. 16] BARS IF 8
INCHES [205MM] THICK OR MORE. TIE BARS SHALL BE PLACED 30 INCHES [760MM]
CENTER-TO-CENTER.
12. HOLES SHALL BE DRILLED 1 FOOT [305MM] INTO THE EXISTING SLAB FOR TIE BARS
AND 7 INCHES [180MM] FOR DOWELS. HOLES SHALL BE OF A DIAMETER SUFFICIENT
TO ACCOMMODATE THE TIE BAR ANCHORAGE OR DOWEL CAP. TIE BARS SHALL BE
ANCHORED WITH AN APPROVED HIGH VISCOSITY EPOXY.
13. IF THE CONCRETE SLAB REMAINING NEXT TO A LONGITUDINAL OR TRANSVERSE
JOINT IS LESS THAN 6 FEET [1829MM] AT ITS NARROWEST WIDTH, REMOVE AND
REPLACE THE EXISTING CONCRETE TO THE JOINT.
GENERAL NOTES - MECHANICAL AND PLUMBING
1. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL
BE EXPOSED.
2. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF
FACE SHOWN OR INDICATED. DUCT SIZES ARE NET INSIDE
DIMENSIONS.
3. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES INCLUDES
DUCT SYSTEM, TERMINAL UNITS, FILTERS, COILS, ETC. LOSS FOR
FILTERS SHALL BE FOR FILTERS AT 50% LOADING.
4. FOR TYPICAL STEAM AND WATER PIPING CONNECTIONS TO
EQUIPMENT, SEE STANDARD EQUIPMENT DETAILS.
5. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR
PLANS ARE NECK SIZES.
6. WATER PIPE CONNECTIONS TO AIR HEATING AND COOLING
COILS SHALL BE MADE TO PROVIDE COUNTER FLOW BETWEEN
WATER AND AIR.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR
EXACT LOCATIONS OF CEILING DIFFUSERS, REGISTERS, AND
GRILLES.
8. HVAC IS TO BE A DESIGN BUILD SYSTEM.
GENERAL NOTES - ELECTRICAL
1. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING
FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL
REFLECTED CEILING PLAN.
2. LIGHTING FIXTURES WITH MORE THAN TWO LAMPS SHALL HAVE
TWO OUTER LAMPS CONTROLLED WITH ONE SWITCH AND INNER
LAMP(S) CONTROLLED BY A SECOND SWITCH.
3. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN
THREE CIRCUITS. EACH BRANCH CIRCUIT HOMERUN SHALL
HAVE A SEPARATE GREEN INSULATED EQUIPMENT GROUNDING
CONDUCTOR.
4. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND
TYPES OF EMERGENCY AND NORMAL BRANCH WIRING DEVICES
SHALL HAVE DIVIDERS BETWEEN DEVICES.
5. LIGHTING AND POWER WILL BE DESIGN BUILD SYSTEM.
DEMOLITION NOTES - MEP
1. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES,
WIRING DEVICES, CONDUITS, ETC., SHOWN ON PLANS TO
BE REMOVED, COMPLETELY CUT/CAP CONDUITS AT THE
AREA OF WORK PERIMETER AND REMOVE CONDUIT WITHIN
THE WORK AREA, DISCONNECT WIRING AT THE
OVERCURRENT PROTECTIVE DEVICE AND REMOVE WIRING
COMPLETELY FROM THE ABANDONED CONDUITS.
2. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT
THE OVERCURRENT PROTECTIVE DEVICE. COMPLETELY
REMOVE ALL ABANDONED WIRING.
3. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS
AND CONDUCTORS PASSING THROUGH RENOVATED
AREAS AND SERVICING UNDISTURBED AREAS.
4. REMOVE AND DISPOSE THE ABANDONED OUTDOOR HVAC
UNIT PROPERLY.
AutoCAD SHX Text
OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT
AutoCAD SHX Text
U.S. DEPARTMENT OF VETERANS AFFAIRS
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
BUILDING 5 TRAILER REPLACEMENT
AutoCAD SHX Text
BUILDING NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text G-200
AutoCAD SHX Text
DWG. OF
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
CORPORAL MICHAEL J. CRESCENZ VAMC 3900 WOODLAND AVE, PHILADELPHIA, PA 19104
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FEBRUARY 2021
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
YS
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
APPROVED: PROJECT DIRECTOR
Scale:
1 SITE PLAN - EXISTING UNDERGROUND UTILITIES MAPPING
NTS Scale:
2 SITE PLAN - EXISTING UNDERGROUND STORM DRAIN LINES
NTS
NOTES
THE SCOPE OF WORK INCLUDED SCANNING THE SPECIFIED AREA TO LOCATE
UNDERGROUND UTILITIES. A TRACER SIGNAL WAS SENT ALONG ANY
ACCESSIBLE METALLIC UTILITY OR TRACER WIRE, AND THE AREA WAS SCANNED
WITH GPR TO LOCATE ANY ADDITIONAL TARGETS. THE LOCATIONS OF ANY
DETECTED UTILITIES AND ANOMALIES WERE MARKED DIRECTLY AT THE SITE
WITH PAINT, FLAGS, STAKES, OR OTHER APPROPRIATE MEANS, AND RESULTS
WERE REVIEWED WITH ONSITE PERSONNEL UNLESS OTHERWISE NOTED.
· THE TOTAL AREA SCANNED WAS APPROXIMATELY 3000 SQUARE FEET.
· SCAN A 3000 SF AREA AROUND THE NORTH AND WEST SIDE OF BUILDING 5.
· THE EFFECTIVE DEPTH OF GPR WILL VARY THROUGHOUT A SITE
DEPENDING ON SURFACE AND SOIL CONDITIONS. IN THIS AREA, THE
MAXIMUM EFFECTIVE GPR DEPTH WAS APPROXIMATELY 0-4 FEET.
NOTES
· SCOPE OUT A DRAIN LINE IN EXISTING CATCH BASIN THE PREVIOUS
TECHNICIAN WAS UNABLE TO DUCT ROD. ALSO INVESTIGATE 4” CAST IRON
PIPE IN CATCH BASIN TO SEE WHAT IT’S COLLECTING.
· THE EFFECTIVE DEPTH OF GPR WILL VARY THROUGHOUT A SITE
DEPENDING ON SURFACE AND SOIL CONDITIONS. IN THIS AREA, THE
MAXIMUM EFFECTIVE GPR DEPTH WAS APPROXIMATELY 5 FEET.
· INVESTIGATED RECESSED PIPE IN CATCH BASIN WALL AND HIT A COMPLETE
BLOCKAGE ABOUT 8' IN. PIPE LOOKS TO BE ABANDONED. ALSO
INVESTIGATED THE 4" CAST IRON PIPE PROTRUDING THROUGH CATCH
BASIN WALL. THIS COLLECTS THE DRAIN AT THE BOTTOM OF THE STEPS AT
NEIGHBORING BUILDING. NOT ABLE TO DETERMINE IF THIS PIPE COLLECTED
ANYTHING ELSE, CAMERA LENS COULD NOT STAY CLEAN.
AutoCAD SHX Text
OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT
AutoCAD SHX Text
U.S. DEPARTMENT OF VETERANS AFFAIRS
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
BUILDING 5 TRAILER REPLACEMENT
AutoCAD SHX Text
BUILDING NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text G-300
AutoCAD SHX Text
DWG. OF
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
CORPORAL MICHAEL J. CRESCENZ VAMC 3900 WOODLAND AVE, PHILADELPHIA, PA 19104
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FEBRUARY 2021
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
YS
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
SITE PLAN - EXISTING UNDERGROUND UTILITIES MAPPING AND STORM DRAIN LINES
AutoCAD SHX Text
APPROVED: PROJECT DIRECTOR
ADMINISTRATIVE
AREA
CONTRACTING
CONFERENCE
ROOM A
ASST. CHIEF
FACILITIES MGMT.
CHIEF
FACILITIES MGMT.
CLOSET
SUPERVISOR'S
OFFICE
FITS CL.
HAC
WOMEN'S
TOILET ROOM
MEN'S
TOILET ROOM
MECHANICAL
ROOM
ELEC.
CL.
CONFERENCE /
PRINT ROOM (KIP)
ADMIN.
OFFICER
CORRIDOR
C1-1
EXISTING SPLIT
SYSTEM AHU
HWH
INTERIOR DESIGN &
LIBRARY
KITCHEN
FEC
ENGINEERING AREA
EXISTING PAD-MOUNTED
TRANSFORMER
EXISTING PAD-MOUNTED
ELECTRIC SERVICE
EXISTING CONCRETE STAIRS
EXISTING CONCRETE
EXISTING OUTDOOR
CONDENSING UNIT
EXISTING STRUCTURE
TO BE DEMOLISHED
EXISTING WINDOW
TO BE DEMOLISHED
Scale:
1 DEMOLITION PLAN
3/16" = 1'-0"
N O
RTH
SYMBOLS OF MATERIALS
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
AutoCAD SHX Text
OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT
AutoCAD SHX Text
U.S. DEPARTMENT OF VETERANS AFFAIRS
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
BUILDING 5 TRAILER REPLACEMENT
AutoCAD SHX Text
BUILDING NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
AD-101
AutoCAD SHX Text
DWG. OF
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
CORPORAL MICHAEL J. CRESCENZ VAMC 3900 WOODLAND AVE, PHILADELPHIA, PA 19104
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FEBRUARY 2021
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
YS
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
DEMOLITION PLAN
AutoCAD SHX Text
APPROVED: PROJECT DIRECTOR
PROPOSED TRAILER REPLACEMENT
(1818 FT2)
EXISTING BUILDING (3700 FT2)
N O
RTH
Scale:
1 FLOOR PLANS (1 OF 2)
3/16" = 1'-0"
AutoCAD SHX Text
OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT
AutoCAD SHX Text
U.S. DEPARTMENT OF VETERANS AFFAIRS
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
BUILDING 5 TRAILER REPLACEMENT
AutoCAD SHX Text
BUILDING NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text A-100
AutoCAD SHX Text
DWG. OF
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
CORPORAL MICHAEL J. CRESCENZ VAMC 3900 WOODLAND AVE, PHILADELPHIA, PA 19104
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FEBRUARY 2021
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
YS
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
FLOOR PLANS (1 OF 2)
AutoCAD SHX Text
APPROVED: PROJECT DIRECTOR
ADMINISTRATIVE
AREA
CONTRACTING
CONFERENCE
ROOM A
ASST. CHIEF
FACILITIES MGMT.
CHIEF
FACILITIES MGMT.
CLOSET
SUPERVISOR'S
OFFICE
FITS CL.
HAC
WOMEN'S
TOILET ROOM
MEN'S
TOILET ROOM
MECHANICAL
ROOM
ELEC.
CL.
CONFERENCE /
PRINT ROOM (KIP)
ADMIN.
OFFICER
CORRIDOR
C1-1
EXISTING SPLIT
SYSTEM AHU
HWH
INTERIOR DESIGN &
LIBRARY
KITCHEN
FEC
ENGINEERING AREA
26'-3"
58-0"
EXISTING PAD-MOUNTED
TRANSFORMER
EXISTING PAD-MOUNTED
ELECTRIC SERVICE
24'-9"
36'-6"
7'-6"
8'-4"
UNISEX
RESTROOM
KI
TC
H
EN
ET
TE
CONFERENCE ROOM
(196 SF)
OFFICE
PARTITIONS
(TYP. 14)
4'-5"4'-5"
PRINTER
STATION
3'
CLERESTORY WINDOWS
(SEE NOTE NO.1)
CLERESTORY WINDOWS
(SEE NOTE NO.1)
WALL
PARTITION
EXISTING CONCRETE
EXISTING OUTDOOR
CONDENSING UNIT
EXISTING CONCRETE STAIRS
Scale:
1 FLOOR PLANS (2 OF 2)
3/16" = 1'-0"
N O
RTH
NOTES:
1. CLERESTORY WINDOWS IN THE PROPOSED PLAN SHOULD BE
INSTALLED 8' ABOVE THE FINISHED FLOOR. THE DIMENSION OF THE
GLASS IS 16' LONG AND 14" WIDE WITH 2" WIDE ALUMINUM FRAME.
2. THE NEW STRUCTURE WILL BE EXPOSED (OPEN) CEILING.
AutoCAD SHX Text
OFFICE OF CONSTRUCTION AND FACILITIES MANAGEMENT
AutoCAD SHX Text
U.S. DEPARTMENT OF VETERANS AFFAIRS
AutoCAD SHX Text
PROJECT NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
BUILDING 5 TRAILER REPLACEMENT
AutoCAD SHX Text
BUILDING NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text A-101
AutoCAD SHX Text
DWG. OF
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
CORPORAL MICHAEL J. CRESCENZ VAMC 3900 WOODLAND AVE, PHILADELPHIA, PA 19104
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FEBRUARY 2021
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
YS
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
FLOOR PLANS (2 OF 2)
AutoCAD SHX Text
APPROVED: PROJECT DIRECTOR
| G-100 |
| Sheets and Views |
| G-100 |
| G-200 |
| Sheets and Views |
| G-200 |
| G-300 |
| Sheets and Views |
| G-300 |
| AD-101 |
| Sheets and Views |
| AD-101 |
| A-100 |
| Sheets and Views |
| A-100 |
| A-101 |
| Sheets and Views |
| A-101 |
File details come from the government source that posted it. Updated .