4. Pittsburgh ARS Air Compressor Maintenance Inspection Requirements.docx

DOCX document 15 KB Posted

Attached to
Air and Breathing Air Compressor Systems Preventive Maintenance Services Federal contract opportunity
Solicitation number
FA671223Q0004
Issued by
Department of the Air Force Reserve Command

View the file

Other files for this federal contract opportunity

Other files attached to Air and Breathing Air Compressor Systems Preventive Maintenance Services, newest first.
File Type Posted
3. Air and Breathing Air Compressor Inventory Pittsburgh ARS.xlsx XLSX spreadsheet
1. Pittsburgh ARS Sources Sought Final.docx DOCX document
2. Pittsburgh ARS Air and Breathing Air Compressor Service PWS.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Air and Breathing Air Compressor Systems Maintenance Requirements

1. Check with operating or area personnel for deficiencies

2. Review shutdown history, if applicable.

3. Perform operational check of compressor system and adjust as required.

4. Replace compressor oil and oil filter

5. Check motor(s) operation for excessive vibration, noise and overheating; lubricate motor(s)

6. Inspect Cooling system, clean cylinder cooling fins, condenser coils and air cooler on compressor.

7. Check tension, condition, and alignment of V-belts; adjust as necessary.

8. Check operation of pressure relief valves.

9. Check low pressure cut in and high pressure cut out switches.

10. Drain moisture from air storage tank and check low pressure cut-in; while draining, check discharge for indication of interior corrosion.

11. Inspect and clean air intake filter on air compressor(s); replace if necessary.

12. Inspect and clean drains

13. Inspect and clean desiccant dryers

14. Clean oil and condensate trap.

15. Check electrical system, indication lamps or gauges for proper operation if appropriate; replace burned out lamps or repair/replace gauges.

16. Clean area around equipment.

17. Fill out maintenance checklist and report deficiencies through Preventive Maintenance Report to the Contracting Officer’s Technical Representative.