36E77620R0006-004.pdf
PDF Posted
- Attached to
- VISN 23 Project 636A8-17-001 "Modernize A Bank Elevators" Federal contract opportunity
- Solicitation number
- 36E77620R0006
About this file
This document provides details for a federal contract solicitation to modernize elevators at a Department of Veterans Affairs medical facility. The scope of work involves upgrading five traction elevators including replacement of controllers, machines, cables, signals and finishes. The solicitation will be issued as a request for proposal conducted according to FAR Parts 15, 19 and 36 for a firm-fixed price construction contract. The solicitation is a total service-disabled veteran-owned small business set aside with a NAICS code of 238210 and size standard of $16.5 million. The period of performance is approximately 323 days with a magnitude of construction between $2 million to $5 million. Proposals are due in late 2019 with award anticipated shortly after.
36E77620R0006 ATTACHMENT 3 - Drawings Iowa City Modernize A Bank Elevators.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36E77620R0006-0004000.docx | DOCX document | |
| 36E77620R0006-0003001.doc | DOC document | |
| 36E77620R0006-0003000.docx | DOCX document | |
| 36E77620R0006-0003002.pdf | ||
| 36E77620R0006-0002001.pdf | ||
| 36E77620R0006-0002003.pdf | ||
| 36E77620R0006-0002002.pdf | ||
| 36E77620R0006-0002000.docx | DOCX document | |
| 36E77620R0006-0002004.docx | DOCX document | |
| 36E77620R0006-0002005.pdf | ||
| 36E77620R0006-0001000.docx | DOCX document | |
| 36E77620R0006-001.docx | DOCX document | |
| 36E77620R0006-009.docx | DOCX document | |
| 36E77620R0006-008.docx | DOCX document | |
| 36E77620R0006-002.docx | DOCX document | |
| 36E77620R0006-003.pdf | ||
| 36E77620R0006-006.pdf | ||
| 36E77620R0006-007.docx | DOCX document | |
| 36E77620R0006-005.pdf |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
12A
12A
12 13 14A
14A
11B
11B
LL
K K
M2 M2
M M
N N
P P
3" RIGID POLYISOCYANURATE
INSULATION WITH EXTERIOR
FACE PAINTED MATTE BLACK.
SEAL THE PERIMETER OF
INSULATION WITH URETHANE
CAULKING.
CAP WALL WITH CROSS-
BROKE 18 GA. GALVANIZED
STEEL. SEAL WITH A
CONTINUOUS BEAD OF
URETHANE CAULKING AND
SCREW GALVANIZED STEEL
TO WALL.
1/4"x1/2"x6"OC
SHEET METAL
SCREWS TO FRAME
REMOVE DAMPER
AND ACUATOR
SHEET ID
D R
A W
N B
Y
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
M
O D
E R
N
IZ
E A
-B A
N K
E L
E V
A T
O R
S
IO
W A
C
IT
Y V
A M
C B
L D
G
IO
W
A C
IT
Y
, I O
W A
D A
T E
D E
S C
R
IP
T
IO
N
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
A N
S I D
M A
R K
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S O
M A
H A
D
IS
T R
IC
T
C A
P
IT
O L
A V
E O
M A
H A
, N E
F O
U R
F R
O N
T D
E S
IG
N
, I N
C
7T H
S T
R A
P
ID
C
IT
Y , S
D
7/
/2
9:
:4
A
M
-Ju ne
1 , H V
A C
F
LO
O R
P
LA
N
1-M-101
JB JG
BID DOCUMENTS
W
2E K
-1 8-
R -0
SPECIFIC NOTE THIS SHEET ONLY
CAP LOUVER WITH 18 GA GALVANIZED STEEL.
CAP OPENING IN WALL WITH 20 GA GALVANIZED
STEEL WITH SCREWS INTO WALL AND SEEL WITH
URETHANE CAULK. INSULATE SPACE WITH 3"
POLYISOCYANURATE INSULATION. SEE DETAIL THIS SHEET.
CAP LOUVER WITH 18 GA GALVANIZED STEEL.
CAP OPENING IN WALL WITH 22 GA GALVANIZED
STEEL WITH SCREWS INTO WALL AND SEEL WITH
URETHANE CAULK. INSULATE SPACE WITH 3"
POLYISOCYANURATE INSULATION. SEE DETAIL THIS SHEET.
1/8" = 1'-0"1 11TH FLOOR HVAC PLAN
NOT TO SCALE2 LOUVER DETAIL
30/30 LOUVER
30/30 LOUVER
68/52
LOUVER
1-P-101
1-P-101
CAP OPEN END.
VERIFY IN FIELD
PIPE SIZE.
TO GRAVITY MAIN
12A
12A
1311B
11B
LL
K K
M2 M2
M M
JJ
1-P-101
1-P-101
12A
12A
1211B
11B
K K
JJ
Sub-basement 73' - 8"
Basement 86' - 10"
KL
PIT PLAN
63' - 5"
1-P-101
L K
Mech Basement 86' - 10"
Mech Sub-Basement 73' - 8"
00.2_Mech Pit Plan 63' - 5"
1-P-101
1211B11
1/4" = 1'-0"1 SUB-BASEMENT PLUMBING PLAN
1/4" = 1'-0"2 ELEVATOR PIT PLUMBING PLAN
1/4" = 1'-0"3 PLUMBING SECTION
1/4" = 1'-0"4 PLUMBING SECTION
SHEET ID
D R
A W
N B
Y
C H
E C
K E
D B
Y
IS
S
U E
D A
T E
M
O D
E R
N
IZ
E A
-B A
N K
E L
E V
A T
O R
S
IO
W A
C
IT
Y V
A M
C B
L D
G
IO
W
A C
IT
Y
, I O
W A
D A
T E
D E
S C
R
IP
T
IO
N
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
A N
S I D
M A
R K
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S O
M A
H A
D
IS
T R
IC
T
C A
P
IT
O L
A V
E O
M A
H A
, N E
F O
U R
F R
O N
T D
E S
IG
N
, I N
C
7T H
S T
R A
P
ID
C
IT
Y , S
D
7/
/2
9:
:4
A
M
-Ju ne
1 , P
LU
M B
IN
G
F
LO
O R
P
LA
N S
A N
D S
E C
T
IO
N S
1-P-101
A ut ho r
C he ck er
BID DOCUMENTS
W
2E K
-1 8-
R -0
SPECIFIC NOTE THIS SHEET ONLY
PLUMBING CONTRACTOR TO INSPECT, TEST, AND
REPAIR PIPING FROM SUMP PUMP TO
CONNECTION POINT ON BUILDING MAIN SANITARY
LINE IN ACCORDANCE WITH 2018 IPC. TEST
RESULTS SHALL BE PROVIDED TO THE
CONTRACTING OFFICERS REPRESENTATIVE.