HAZARDOUS MATERIALS SURVEY
Jacobs Engineering
3161 Michelson Drive
Irvine, CA 96212
May 19, 2015
Terracon Project No. 60157019
Prepared for:
Jacobs Engineering
Prepared by:
Terracon Consultants, Inc.
Irvine, California
TABLE OF CONTENTS Page
1.0 INTRODUCTION
1.1 Scope of Services
1.2 General Conditions and Limitations
1.3 Reliance
2.0 BUILDING DESCRIPTION
3.0 FIELD ACTIVITIES
3.1 Visual Assessment
3.2 Suspected Asbestos-Containing Material Sampling
3.3 Suspected Lead-Containing Paint Sampling Results
4.0 RECOMMENDATIONS
APPENDIX A Asbestos Laboratory Data
APPENDIX B Lead-in Paint Laboratory Data
APPENDIX C Inspector Certifications
APPENDIX D Photographs
May 21, 2015
Brent Marino
Jacobs Engineering, Inc.
23161 Michelson drive
Irvine, California 92612
Re: Hazardous Materials Survey
Maintenance Buildings
Fort Rosecrans Cemetery
San Diego, California 92106
Dear Mr. Marino:
The purpose of this report is to present the results of pre-demolition Asbestos Survey, Lead-Based Paint
Survey, and Universal Waste (UW) Assessments conducted on April 27, 2015 at the Fort Rosecrans
Cemetery in San Diego, California. The services were conducted in general accordance with our
Proposal No. August 14, 2014.
Terracon Consultants, Inc. (Terracon) appreciates the opportunity to provide the above-described services to Jacobs Engineering. If you have any questions regarding the content of this report or if we can be of further assistance, please contact Mr. David Silveri 949-864-2052.
Sincerely, TERRACON
David Silveri Michael Benefield, PE Department Manager Department Manager CAC, CDPH, HAZWOPER Supervisor CAC, CDPH
Hazardous Materials Survey
Fort Rosecrans Cemetery ■ San Diego, California
May 21, 2015 ■ Terracon Project No. 60157019
Reliable ■ Responsive ■ Convenient ■ Innovative 2
HAZARDOUS MATERIALS SURVEY
Fort Rosecrans Cemetery
San Diego, California, 92106
1.0 INTRODUCTION
1.1 Scope of Services
Terracon Consultants, Inc. (Terracon) conducted an asbestos survey, lead-based paint survey and universal waste (UW) assessment at the Fort Rosecrans Cemetery in San Diego, California. Terracon understands that these services were requested due to a planned demolition. The buildings consisted of a vehicle garage and office building, a hazardous waste storage building, and two storage sheds.
The scope of this project consisted of performing visual assessments for UW, collection of suspect asbestos-containing materials (ACM) samples and suspect lead-based paint (LBP) samples.
Bulk samples of suspect ACM were submitted under chain of custody to LA Testing in Garden
Grove, California for analysis by polarized light microscopy (PLM) with dispersion staining techniques per Environmental Protection Agency (EPA) methodology (40 CFR 763, Subpart
E). The percentage of asbestos, where applicable, was determined by microscopic visual estimation. LA Testing is accredited under the National Voluntary Laboratory Accreditation
Program (NVLAP Accreditation No. 101384-0). LA Testing is also a branch of EMSL laboratories. EMSL is a nationally recognized leader in Asbestos, Lead, and Microbial sample analysis (Accreditation No. 200155-0).
Paint samples were chosen from each unique combination of paint color and substrate. The paint chips were collected and submitted to LA Testing in Garden Grove, California for analysis (ELLAP Accreditation No. 101650). The paint chips were analyzed by flame atomic absorption according to National Institute for Occupational Safety and Health (NIOSH) method
7420.
Terracon completed a visual inspection for UW at the site. UW’s are hazardous wastes produced by households and many different types of businesses. UW includes televisions, computers, and other electronic devices as well as batteries, fluorescent lamps, mercury thermostats, and other mercury containing equipment, among other things. The hazardous waste regulations (CA Code of Regulations Title 22, division 4.5, chapter 11, section 66261.9) identify seven categories of hazardous waste that can be managed as universal waste. Any unwanted items that fall within one of these streams can be handled, transported and recycled following the simple requirements set forth in the universal waste regulation, CA Code of Regulations Title 22, division 4.5, Chapter 23, commonly known as
Reliable ■ Responsive ■ Convenient ■ Innovative 3 the Universal Waste Rule. Refer to the CA Department of Toxic Substances Control for further information.
1.2 General Conditions and Limitations
The above-described services were conducted at the site on, April 27, 2015. The activities completed for this assessment were limited to the scope of services outlined in our proposal.
Terracon did not attempt to identify every potential exposure or hazard present in the subject building. There may be conditions hidden from sight or inaccessible locations. Access was provided by the building maintenance engineer.
The results, findings, and recommendations expressed in this report are based exclusively on conditions observed during our April 27, 2015 assessment. The information contained in this report should not be relied upon to represent conditions that existed previously or at a later date. Terracon does not warrant the services of regulatory agencies, laboratories or other third parties supplying information, which may have been used in the preparation of this report. No warranty, express or implied is made.
1.3 Reliance
This report is for the exclusive use of Jacobs Engineering for the project being discussed. No other individual or entity may rely on this report without written permission of Terracon and
Jacobs Engineering. Reliance on this report by Jacobs Engineering and all authorized parties will be subject to the key understandings and limitations stated in our proposal.
2.0 BUILDING DESCRIPTION
The buildings consist of a wood frame vehicle garage, an office building with a metal roof, a small wood frame hazardous waste storage building, and two metal storage sheds.
3.0 FIELD ACTIVITIES
3.1 Visual Assessment
A walk-through of accessible areas of the building was conducted to visually assess the presence of lead-containing building components, asbestos containing building components and the existence of UW.
3.2 Suspected Asbestos-Containing Material Sampling
Terracon collected a total of thirty (30) bulk samples from ten (10) homogeneous areas of suspect ACM various building components. The samples were placed into small plastic bags
Reliable ■ Responsive ■ Convenient ■ Innovative 4 and sent to LA Testing laboratory with chain-of-custody for analysis by PLM. Analytical laboratory results can be found in Appendix A.
A summary of the asbestos sampling results obtained during this assessment are provided in Table 1 below.
Table 1
Asbestos Sample Summary
HA Sample
No.
Description Sample Location Results Quantity of
ACM
1 Gray Penetration Mastic Vehicle Canopies SW
Corner
5% CH
10 sf
2 Gray Penetration Mastic Vehicle Canopies SW
Corner
5% CH
3 Gray Penetration Mastic Vehicle Canopies SW
Corner
4 Gray Penetration Mastic Vehicle Garage Roof
Around 1 Vent West Side
5% CH
15 sf
5 Gray Penetration Mastic Vehicle Garage Roof
Around 1 Vent West Side
6 Gray Penetration Mastic Vehicle Garage Roof
Around 1 Vent West Side
7 Shingles Storage Containers Roof
#5001 & 5002 NE
ND
360 sf
8 Shingles Storage Containers Roof
#5001 & 5002 SE
ND
9 Shingles Storage Containers Roof
#5001 & 5002 SW
10 Black Penetration Mastic Storage Containers Roof
#5001 & 5002 NE
5% CH
10 sf
11 Black Penetration Mastic Storage Containers Roof
#5001 & 5002 SW
12 Black Penetration Mastic Storage Containers Roof
#5001 & 5002 NW
13 Wall Texture Temporary Water
Closet/RR N
Wall Texture Temporary Water
Closet/RR E
Wall Texture Temporary Water
Closet/RR S
Wallboard with joint
Compound and Tape
Temporary Water Closet/RR N
Wallboard with joint
Compound and Tape
Temporary Water Closet/RR E
Reliable ■ Responsive ■ Convenient ■ Innovative 5
HA Sample
No.
Description Sample Location Results Quantity of
ACM
Wallboard with joint
Compound and Tape
Temporary Water Closet/RR W
19 Roof Core Temporary Water Closet/RR Roof
Roof Core Temporary Water
Roof Core Temporary Water
22 Black Penetration Mastic Temporary Water
Black Penetration Mastic Temporary Water
Black Penetration Mastic Temporary Water
25 Roof Core Temporary Building Roof ND
26 Roof Core Temporary Building Roof ND
27 Roof Core Temporary Building Roof ND
28 Linoleum Temporary Building N ND
29 Linoleum Temporary Building S ND
30 Linoleum Temporary Building E ND
Legend:
ND = None detected
CH = Chrysotile asbestos
Based on the results of laboratory analysis, asbestos in concentrations greater than 1% was identified in roof penetration mastic. The roof penetration mastic is considered a Category I non-friable material, and appeared in undamaged condition. Mirror mastic could not be sampled, and was assumed to contain asbestos. The mirror mastic is a Category II non-friable material and did not appear to be damaged.
3.3 Suspected Lead-Containing Paint Sampling Results
Terracon collected a total of eleven (11) paint chip samples from unique combinations of paint color. The samples were placed into small plastic bags and sent to LA Testing of Garden
Grove, California under chain-of-custody procedures for analysis by flame atomic absorption.
A summary of the LBP sampling results obtained during this assessment are provided in
Table 2 below.
Reliable ■ Responsive ■ Convenient ■ Innovative 6
TABLE 2
Lead-Paint Summary
Sample
No. Color Substrate Component
Result
(ppm)
Pb-1 White Metal Exterior Storage Container 140
Pb-2 White Metal Exterior Storage Container 1900
Pb-3 White Concrete Garage Wall <100
Pb-4 White Metal Canopy Post 43,000
Pb-5 White Metal Canopy Post <100
Pb-6 Yellow Metal Garage Door Hardware 330
Pb-7 White Concrete Inside Garage 470
Pb-8 Tan Wallboard Restroom Wall <100
Pb-9 Tan Wallboard Outside Restroom <100
Pb-10 White Wood Temporary Shed Wall 680
Pb-11 Gray Wood Temporary Shed Wall <100 ppm-parts per million
The EPA has defined LBP as paint containing greater than 1.0 milligram per square centimeter (mg/cm2) or 0.5 percent (%) by weight or 5000 parts per million (ppm). Lead-containing waste from renovation or demolition activities, such as debris, paint chips, dust, and sludge’s, that exhibit the toxicity characteristic must generally be managed and disposed of as a hazardous waste. Laboratory analysis reported that lead was detected in six of the eleven samples and LBP was detected on the white canopy post. The paint chip laboratory analytical report and chain of custody are included in Appendix B.
3.4 Universal Waste and Regulated Wastes
The visual investigation to determine the presence of universal and other regulated wastes indicated the following:
No Tritium exit signs
PCB’s – No PCB ballasts were observed
100 Fluorescent Lighting Tubes
No Mercury switches/thermostats
No Emergency Lights
Oil storage on-site
Diesel Gas Tank on-site
Cleaning Chemicals on-site
Paint and painting supplies on-site
4.0 RECOMMENDATIONS
Asbestos
Develop a work plan for the removal of the ACMs identified in the survey. The purpose of a work plan is to clearly define the scope of work for more competitive
Reliable ■ Responsive ■ Convenient ■ Innovative 7 and accurate bidding as well as to reduce the number of costly delays and change orders during the project.
Project Management to include all health & safety and environmental construction management such as: project bidding; review of abatement contractor submittals;
consultation on regulatory requirements; project tracking; scheduling; attending progress meetings; coordination with all members of the project team; senior project oversight of abatement contractor.
Retain a Certified Asbestos Consultant or Site Surveillance Technician to provide on-site construction supervision of the asbestos abatement contractor to ensure utilization of proper work practices as stated in the work plan or specification. The Consultant also ensures that all local, state and federal regulations are followed and that the project remains on schedule. The on-site Consultant generates documentation of contractor work practices and training, and asbestos air sampling results. The on-site Consultant also ensures that all asbestos materials are removed by the abatement contractor and properly manifested.
Request the Asbestos Consultant to collect a sufficient number of air samples on a daily basis to demonstrate that the abatement contractor is not releasing airborne asbestos fibers outside their work area.
Request the Asbestos Consultant to visually review the work of the abatement contractor to verify that all the ACMs are abated. If the work areas pass the visual clearance, then final air clearance samples are collected to ensure that the area is safe for re-occupancy, or unregulated work.
Request a final written report outlining all activities that transpired throughout the course of the abatement project.
Lead-Containing Materials
Contractor must comply with Title 17 California Code of Regulations, Division 1, Chapter 8 and OSHA Lead-in Construction Standard, Title 8 CCR 1532.1 and other applicable state and local regulations for work methods, training, worker protection, hazard communications, work practices, engineering controls, and proper waste disposal of lead-based paint and lead-containing paint.
Universal and Other Regulated Wastes
Any unwanted UW items that fall within one of the waste streams identified by the DTSC can be handled, transported and recycled in accordance with the Universal Waste Rule.
APPENDIX A
Asbestos Laboratory Data
LA Testing 11652 Knott Street Unit F5, Garden Grove, CA 92841 Phone/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com gardengrovelab@latesting.com
331507413 CustomerID: 32TERR45 CustomerPO: 60152019 ProjectID:
LA Testing Order:
Attn: Dave Silveri Terracon Consultants, Inc.
2817 McGaw Avenue Irvine, CA 92614
Received: 04/23/15 4:15 PM
FT Rosecrans - 60152019
Fax:
Phone: (949) 261-0051
Project:
4/28/2015Analysis Date:
4/22/2015Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
1-RF4-1
331507413-0001
SW Corner Gray/Black Fibrous Homogeneous
Chrysotile5%Non-fibrous (other)95%
1-RF4-2
331507413-0002
SW Corner Gray/Black Fibrous Homogeneous
Chrysotile5%Non-fibrous (other)95%
1-RF4-3
331507413-0003
SW Corner Gray/Black Fibrous Homogeneous
Chrysotile5%Non-fibrous (other)95%
2-RF4-4
331507413-0004
West Side Gray/Black Fibrous Homogeneous
Chrysotile5%Non-fibrous (other)95%
2-RF4-5
331507413-0005
West Side Gray/Black Fibrous Homogeneous
Chrysotile5%Non-fibrous (other)95%
2-RF4-6
331507413-0006
West Side Gray/Black Fibrous Homogeneous
Chrysotile5%Non-fibrous (other)95%
3-RF6-7-Shingle 1
331507413-0007
NE Brown/Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
3-RF6-7-Shingle 2
331507413-0007A
NE Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
1Test Report PLM-7.28.9 Printed: 4/28/2015 11:56:18 AM
Michael DeCavallas, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by LA Testing Garden Grove, CA NVLAP Lab Code 101384-0, CA ELAP 1406
Initial report from 04/28/2015 11:56:18
Mindy Le (39) http://www.LATesting.com mailto:gardengrovelab@latesting.com
Phone/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com gardengrovelab@latesting.com
331507413 CustomerID: 32TERR45 CustomerPO: 60152019 ProjectID:
LA Testing Order:
Attn: Dave Silveri Terracon Consultants, Inc.
2817 McGaw Avenue Irvine, CA 92614
Received: 04/23/15 4:15 PM
FT Rosecrans - 60152019
Fax:
Phone: (949) 261-0051
Project:
4/28/2015Analysis Date:
4/22/2015Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
3-RF6-7-Felt
331507413-0007B
NE Black None Detected Fibrous Homogeneous
Cellulose25% Non-fibrous (other)75%
3-RF6-8-Shingle 1
331507413-0008
SE Brown/Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
3-RF6-8-Shingle 2
331507413-0008A
SE Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
3-RF6-8-Felt
331507413-0008B
SE Black None Detected Fibrous Homogeneous
Cellulose25% Non-fibrous (other)75%
3-RF6-9-Shingle 1
331507413-0009
SW Brown/Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
3-RF6-9-Shingle 2
331507413-0009A
SW Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
3-RF6-9-Felt
331507413-0009B
SW Black None Detected Fibrous Homogeneous
Cellulose25% Non-fibrous (other)75%
4-RF4-10
331507413-0010
NE Gray/Black Fibrous Homogeneous
Chrysotile5%Non-fibrous (other)95%
2Test Report PLM-7.28.9 Printed: 4/28/2015 11:56:18 AM
Michael DeCavallas, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by LA Testing Garden Grove, CA NVLAP Lab Code 101384-0, CA ELAP 1406
Initial report from 04/28/2015 11:56:18
Mindy Le (39)
Phone/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com gardengrovelab@latesting.com
331507413 CustomerID: 32TERR45 CustomerPO: 60152019 ProjectID:
LA Testing Order:
Attn: Dave Silveri Terracon Consultants, Inc.
2817 McGaw Avenue Irvine, CA 92614
Received: 04/23/15 4:15 PM
FT Rosecrans - 60152019
Fax:
Phone: (949) 261-0051
Project:
4/28/2015Analysis Date:
4/22/2015Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
4-RF4-11
331507413-0011
SW Gray/Black Fibrous Homogeneous
Chrysotile5%Non-fibrous (other)95%
4-RF4-12
331507413-0012
NW Gray/Black Fibrous Homogeneous
Chrysotile5%Non-fibrous (other)95%
5-MS5-13
331507413-0013
N White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
5-MS5-14
331507413-0014
E White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
5-MS5-15
331507413-0015
S White None Detected Non-Fibrous Homogeneous
Non-fibrous (other)100%
6-WB1-16-Joint Compound 331507413-0016
N White None Detected
Sample does not contain tape.
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
6-WB1-16-
Wallboard 331507413-0016A
N Brown/White None Detected Fibrous
Heterogeneous
Cellulose10% Gypsum60% Non-fibrous (other)30%
3Test Report PLM-7.28.9 Printed: 4/28/2015 11:56:18 AM
Michael DeCavallas, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by LA Testing Garden Grove, CA NVLAP Lab Code 101384-0, CA ELAP 1406
Initial report from 04/28/2015 11:56:18
Mindy Le (39)
Phone/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com gardengrovelab@latesting.com
331507413 CustomerID: 32TERR45 CustomerPO: 60152019 ProjectID:
LA Testing Order:
Attn: Dave Silveri Terracon Consultants, Inc.
2817 McGaw Avenue Irvine, CA 92614
Received: 04/23/15 4:15 PM
FT Rosecrans - 60152019
Fax:
Phone: (949) 261-0051
Project:
4/28/2015Analysis Date:
4/22/2015Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
6-WB1-17-Joint Compound 331507413-0017
E White None Detected
Sample does not contain tape.
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
6-WB1-17-
Wallboard 331507413-0017A
E Brown/White None Detected Non-Fibrous
Homogeneous
Cellulose10% Gypsum60% Non-fibrous (other)30%
6-WB1-18-Joint Compound 331507413-0018
W White None Detected
Sample does not contain tape.
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
6-WB1-18-
Wallboard 331507413-0018A
W Brown/White None Detected Fibrous
Heterogeneous
Cellulose10% Gypsum60% Non-fibrous (other)30%
7-RF6-19
331507413-0019
Roof White/Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
7-RF6-20
331507413-0020
Roof White/Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
7-RF6-21
331507413-0021
Roof White/Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
4Test Report PLM-7.28.9 Printed: 4/28/2015 11:56:18 AM
Michael DeCavallas, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by LA Testing Garden Grove, CA NVLAP Lab Code 101384-0, CA ELAP 1406
Initial report from 04/28/2015 11:56:18
Mindy Le (39)
Phone/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com gardengrovelab@latesting.com
331507413 CustomerID: 32TERR45 CustomerPO: 60152019 ProjectID:
LA Testing Order:
Attn: Dave Silveri Terracon Consultants, Inc.
2817 McGaw Avenue Irvine, CA 92614
Received: 04/23/15 4:15 PM
FT Rosecrans - 60152019
Fax:
Phone: (949) 261-0051
Project:
4/28/2015Analysis Date:
4/22/2015Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
8-RF4-22
331507413-0022
Roof Black None Detected Fibrous Homogeneous
Cellulose20% Non-fibrous (other)80%
8-RF4-23
331507413-0023
Roof Black None Detected Fibrous Homogeneous
Cellulose20% Non-fibrous (other)80%
8-RF4-24
331507413-0024
Roof Black None Detected Fibrous Homogeneous
Cellulose20% Non-fibrous (other)80%
9-RF6-25
331507413-0025
Roof White/Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
9-RF6-26
331507413-0026
Roof White/Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
9-RF6-27
331507413-0027
Roof White/Black None Detected Fibrous Heterogeneous
Glass15% Non-fibrous (other)85%
10-FC1-28
331507413-0028
N Gray/White None Detected Fibrous Heterogeneous
Cellulose25% Non-fibrous (other)75%
10-FC1-29
331507413-0029
S Gray/White None Detected Fibrous Heterogeneous
Cellulose25% Non-fibrous (other)75%
5Test Report PLM-7.28.9 Printed: 4/28/2015 11:56:18 AM
Michael DeCavallas, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by LA Testing Garden Grove, CA NVLAP Lab Code 101384-0, CA ELAP 1406
Initial report from 04/28/2015 11:56:18
Mindy Le (39)
Phone/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com gardengrovelab@latesting.com
331507413 CustomerID: 32TERR45 CustomerPO: 60152019 ProjectID:
LA Testing Order:
Attn: Dave Silveri Terracon Consultants, Inc.
2817 McGaw Avenue Irvine, CA 92614
Received: 04/23/15 4:15 PM
FT Rosecrans - 60152019
Fax:
Phone: (949) 261-0051
Project:
4/28/2015Analysis Date:
4/22/2015Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
10-FC130
331507413-0030
E Gray/White None Detected Fibrous Heterogeneous
Cellulose25% Non-fibrous (other)75%
6THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.28.9 Printed: 4/28/2015 11:56:18 AM
Michael DeCavallas, Laboratory Manager or other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by LA Testing Garden Grove, CA NVLAP Lab Code 101384-0, CA ELAP 1406
Initial report from 04/28/2015 11:56:18
Mindy Le (39)
APPENDIX C
Lead-Based Paint Laboratory Data
ConcentrationAnalyzed RDL LeadClient SampleDescription Collected
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
LA Testing 11652 Knott Street Unit F5, Garden Grove, CA 92841 Phone/Fax: (714) 828-4999 / (714) 828-4944 http://www.LATesting.com gardengrovelab@latesting.com
Attn: David Silveri Terracon Consultants, Inc.
2817 McGaw Avenue Irvine, CA 92614
Received: 04/23/15 4:15 PM
60157019
Fax:
Phone: (949) 261-0051
Project:
Collected:
331507367 CustomerID: 32TERR45 CustomerPO: 60157019 ProjectID:
LA Testing Order:
Site: Ext Storage Container 5001 White 140 ppm4/27/2015
331507367-0001 100Pb-1 ppm
Site: Ext Storage Container 5002 White 1900 ppm4/27/2015
331507367-0002 100Pb-2 ppm
Site: Garage White Concrete Walls <100 ppm4/27/2015
331507367-0003 100Pb-3 ppm
Site: Canopy White Metal Post 43000 ppm4/27/2015
331507367-0004 5000Pb-4 ppm
Site: Canopy White Wood Post <100 ppm4/27/2015
331507367-0005 100Pb-5 ppm
Site: Ylw Metal Door Hardware-Garage 330 ppm4/27/2015
331507367-0006 110Pb-6 ppm
Site: White on Concrete in Garage 470 ppm4/27/2015
331507367-0007 100Pb-7 ppm
Site: Int Tan Wall in Restroom <100 ppm4/27/2015
331507367-0008 100Pb-8 ppm
Site: Ext Tan Wall on Restroom <100 ppm4/27/2015
331507367-0009 100Pb-9 ppm
Site: Ext White Wall on Temporary Shed 680 ppm4/27/2015
331507367-0010 100Pb-10 ppm
Site: Ext Gray Wall on Temporary Storage <100 ppm4/27/2015
331507367-0011 100Pb-11 ppm
Page 1 of 1Test Report PB w/RDL-7.32.3 Printed: 4/27/2015 3:31:09 PM
Michael Chapman, Laboratory Manager or other approved signatory
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements established by the AIHA-LAP, unless specifically indicated otherwise.
Samples analyzed by LA Testing Garden Grove, CA AIHA-LAP, LLC--ELLAP Accredited #101650, CA ELAP 1406
Initial report from 04/27/2015 15:31:09
Company :
EMSL-Bill to:
If Bill to is Different note instructions in Comments**
Street: Third Party Billing requires written authorization from third party
City: State/Province: Zip/Postal Code: Country:
Report To (Name):
Telephone #:
Email Address: Fax #: Purchase Order:
Project Name/Number: Please Provide Results:
U.S. State Samples Taken: CT Samples: Commercial/Taxable Residential/Tax Exempt
Turnaround Time (TAT) Options* - Please Check 3 Hour 6 Hour 24 Hour 48 Hour 72 Hour 96 Hour 1 Week 2 Week
*Analysis completed in accordance with EMSL’s Terms and Conditions located in the Price Guide Matrix Method Instrument Reporting Limit Check
Chips % by wt. mg/cm² ppm SW846-7000B Flame Atomic Absorption 0.01%
Air NIOSH 7082 Flame Atomic Absorption 4 µg/filter NIOSH 7105 Graphite Furnace AA 0.03 µg/filter NIOSH 7300 modified ICP-AES/ICP-MS 0.5 µg/filter Wipe* ASTM non ASTM
*if no box is checked, non-ASTM Wipe is assumed
SW846-7000B Flame Atomic Absorption 10 µg/wipe SW846-6010B or C ICP-AES 1.0 µg/wipe SW846-7000B/7010 Graphite Furnace AA 0.075 µg/wipe
TCLP
SW846-1311/7000B/SM 3111B Flame Atomic Absorption 0.4 mg/L (ppm) SW846-1131/SW846-6010B or C ICP-AES 0.1 mg/L (ppm)
Soil
SW846-7000B Flame Atomic Absorption 40 mg/kg (ppm) SW846-7010 Graphite Furnace AA 0.3 mg/kg (ppm)
SW846-6010B or C ICP-AES 2 mg/kg (ppm)
Wastewater Unpreserved Preserved with HNO3 pH < 2
SM3111B/SW846-7000B Flame Atomic Absorption 0.4 mg/L (ppm) EPA 200.9 Graphite Furnace AA 0.003 mg/L (ppm) EPA 200.7 ICP-AES 0.020 mg/L (ppm)
Drinking Water Unpreserved Preserved with HNO3 pH < 2
EPA 200.9 Graphite Furnace AA 0.003 mg/L (ppm) EPA 200.8 ICP-MS 0.001 mg/L (ppm)
TSP/SPM Filter 40 CFR Part 50 ICP-AES 12 µg/filter 40 CFR Part 50 Graphite Furnace AA 3.6 µg/filter
Other:
Name of Sampler:
Signature of Sampler:
Sample # Location Volume/Area Date/Time Sampled
Client Sample #’s - Total # of Samples:
Relinquished (Client):
Date:
Time:
Received (Lab):
Date:
Time:
Comments:
Lead (Pb) Chain of Custody EMSL Order ID (Lab Use Only):
PHONE:
FAX:
Page 1 of ____ pages
LATesting 11652 Knott Avenue, Unit F5
Garden Grove, CA 92841
(714) 828-4999
(714) 828-4944
Terracon ✔
2817 McGaw Avenue Irvine CA 92614 United States
David Silveri (949) 281-0051 dave.silveri@terracon.com (949) 261-6110
60157019
CA
BillTo: Terracon, 2817 McGaw Avenue, Irvine, CA, 92614, United States Attention: David Gengenbacher Phone: (949) 281-0051 Email: dpgengenbacher@terracon.com Purchase Order:
aayran Typewritten Text Different aayran Typewritten Text aayran Typewritten Text aayran Typewritten Text aayran Typewritten Text aayran Typewritten Text
FAX
aayran Typewritten Text E-mail aayran Typewritten Text Mail aayran Typewritten Text Same
Additional Pages of the Chain of Custody are only necessary if needed for additional sample information
Sample # Location Volume/Area Date/Time Sampled
Comments/Special Instructions:
Page ______ of ______ pages
LEAD (Pb) CHAIN OF CUSTODY EMSL ORDER ID (Lab Use Only):
PHONE:
FAX:
LATesting 11652 Knott Avenue, Unit F5
Garden Grove, CA 92841
(714) 828-4999
(714) 828-4944
BillTo: Terracon, 2817 McGaw Avenue, Irvine, CA, 92614, United States Attention: David Gengenbacher Phone: (949) 281-0051 Email: dpgengenbacher@terracon.com Purchase Order:
APPENDIX C
Inspector Certifications
APPENDIX D
Photographs
Fort Rosecrans National Cemetery-Maintenance Yard Project No. 60157019 Photo Date: April 21, 2015
Photo #1 Overview. Photo #2 Penetration Mastic.
Photo #3 Penetration Mastic. Photo #4 . Penetration Mastic.
| Yard Pb COC.pdf |
| Word Bookmarks |
| Text120 |
| Text116 |
| Text118 |
| Text17 |
| Text119 |
| Text14 |
| Text141 |
| Check59 |
| Check60 |
| Check4 |
| Check5 |
| Check6 |
| Check7 |
| Check8 |
| Check9 |
| Check10 |
| Check11 |
| Check12 |
| Check13 |
| Check14 |
| Check15 |
| Check16 |
| Check17 |
| Check61 |
| Check18 |
| Check19 |
| Check20 |
| Check21 |
| Check22 |
| Check70 |
| Check71 |
| Check23 |
| Check24 |
| Check25 |
| Check69 |
| Check68 |
| Check26 |
| Check62 |
| Check63 |
| Text142 |
| Text143 |
| Text144 |
| Text145 |
| Text146 |
| Text147 |
| Text124 |
| Text129 |
| Text121 |
| Text122 |
| Text123 |
File details come from the government source that posted it.