This document is a combined synopsis/solicitation notice for a robotic prescription dispensing system. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22 is seeking a contractor to provide a ScriptPro SP100/CCC robotic prescription dispensing system with collating control center for the Southern Arizona VA Health Care System in Tucson, Arizona. Offers are due by December 6, 2023 at 12:00PM Pacific time and should include vendor information, concurrence with solicitation terms, a schedule of services with manufacturer and part numbers for the robotic system and four robotic cell multiplexors, and pricing for items, installation, and 12 months of support. The solicitation number is 36C26224Q0283 and responses should be emailed to the specified contracting officer.
The robotic system must meet requirements for medication capacity, prescription processing speed, interface functionality, inventory tracking, automatic labeling, and safety features. The contractor will also be responsible for installation, testing, user training, moving an existing cabinet, and removing the current robotic system. The contractor's solution must integrate with the facility's existing infrastructure and workflow systems.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 1 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING.docx | DOCX document | |
| Statement of Work SP100.docx | DOCX document | |
| S02 36C26224Q0283.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Combined Synopsis/Solicitation Notice
| SUBJECT* |
| ScriptPro Robot SP 100 |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 90815 |
| SOLICITATION NUMBER* |
| 36C26224Q0283 |
| RESPONSE DATE/TIME/ZONE |
| 12-06-2023 12:00PM PACIFIC TIME, LOS ANGELES, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339112 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 22 4811 Airport Plaza Drive Suite 600 Long Beach CA 90815
POINT OF CONTACT*
CONTRACT SPECIALIST
ISRAEL GARCIA
ISRAEL.GARCIA2@VA.GOV
PLACE OF PERFORMANCE
| ADDRESS |
| Department Of Veterans Affairs |
Southern Arizona VA Healthcare System
3601 S 6th Ave
Tucson AZ
| POSTAL CODE |
| 85723-0001 |
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
| *= Required Field |
| Combined Synopsis/Solicitation Notice |
Combined Synopsis/Solicitation Notice
1. This is a combined synopsis/solicitation for commercial services/items prepared in accordance with the format in FAR Subpart 12.6 in conjunction with FAR Part 13, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued.
1.a. Project Title: ScriptPro SP100/CCC, Robotic Prescription Dispensing System.
1.b. Description: The Southern Arizona VA Health Care System (SAVAHCS) is seeking a contractor to provide a ScriptPro SP100/CCC, Robotic Prescription Dispensing System with Collating Control Center.
1.c. Project Location: Southern Arizona VA Health Care System (SAVAHCS) Tucson, AZ.
1.d. Solicitation Number: Request for Quotes (RFQ) - 36C26224Q0283.
1.e. Set Aside: NA 1.f. Applicable NAICS code: 339112 Surgical and Medical Instrument Manufacturing 1.g. Small Business Size Standard: 1000 employees 1.h. Type of Contract: Firm Fixed Price
2. Scope. The Veteran’s Integrated Service Network 22 is seeking a contractor to provide a ScriptPro SP100/CCC, Robotic Prescription Dispensing System with Collating Control Center, installation, and support for purchase. Model Number MB284264 or equivalent having the following salient characteristics, adhering to the S02 36C26224Q0283 and Statement of Work (SOW) attachments.
Brand name Information:
Manufacturer:
· SCRIPTPRO USA INC.
Nomenclature:
· SP 100/CCC
Model Number:
· MB284264
Qty:
· Please see price Schedule
Equal to product Information:
Salient Characteristics:
ScriptPro SP 100 robotic prescription dispensing system.
· Must hold up to 100 different medications, dispensing them accurately and quickly.
· Provide additional level of safety for each drug cell and corresponding barcode, ensuring the correct drug is dispensed each time.
· Must fill up to 150 prescriptions per hour, enhancing productivity and efficiency.
· Must have a user-friendly interface with easy-to-use touchscreen that facilitates workflow management.
· Must keep track of medication inventory, helping pharmacies manage their stock more efficiently.
· Must automatically print and apply patient labels to prescription vials, saving time and minimizing labeling errors.
· Can be configured to dispense different quantities of medication, allowing it to handle prescriptions of varying sizes.
· Must have a built-in safety feature, such as drug verification checks and warning systems to prevent dispensing in case of a mismatch or error.
· Must include robust maintenance and support options to ensure continuous and trouble-free operation.
· Must install new SP100 robot with 4 new robotic cell multiplexors (RCMs).
· Must test new SP100 robot to ensure full functionality.
· Must train users and subject matter experts (SMEs) on new hardware.
· Must move PIV cabinet and cabinet power to alternative site (already established area).
· Must remove existing robot from site.
· Software and hardware must integrate with existing infrastructure and workflow.
· Interoperability with VA VistA via HL7 interface and Outpatient Pharmacy Automation Interface (OPAI)
· Approved by ScriptPro LLC for use with their system.
· Installation approved by ScriptPro LLC for use with their system.
· Not interfere with the current ScriptPro maintenance contract
· Ability to function on a virtual local area network (VLAN)
· Meets or exceeds OI&T HL7 data transmissions and security requirements.
· Secure login
3. Submit written offers with spec-sheets of proposed items in accordance with the following instructions, as well as Addendum to FAR 52.212-1, Instruction to Offerors. Oral offers will not be accepted. Complete and submit enclosure 1 via email no later than 12:00PM PST Wednesday December 06, 2023, to israel.garcia2@va.gov. Ensure the following are completed and/or included in the quote packet:
3.a. Vendor Information with SAM UEI.
3.b. Concurrence/non-concurrence with solicitation terms, conditions, and provisions 3.c. Schedule of services. Items shall be FOB destination. Please specify offered item manufacturer and part number.
3.d. Provide an Authorized Distributor Letter/Memo form manufacturer if applicable.
3.e. Product must comply with the Buy American Act, Trade Agreement Act and all other clauses stated on the S02 36C26224Q0283 document.
3.f. Fill out and sign Attachment #1 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING--CERTIFICATE OF COMPLIANCE FOR SUPPLIES AND PRODUCTS with your submission if applicable.
PRICE/COST SCHEDULE
ITEM INFORMATION
| ITEM NUMBER |
| DESCRIPTION OF SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1.00 |
| EA |
| _____________ |
| _____________ |
Robotic Prescription Dispensing System with 6 slot Collating Control Center
LOCAL STOCK NUMBER: MB284264
| 4.00 |
| EA |
| _____________ |
| _____________ |
Robotic Cell Multiplexor for SPx00 robots
LOCAL STOCK NUMBER: GD840709
| 1.00 |
| EA |
| ____________ |
| _____________ |
Credit for SP50 Robotic System Trade-In
LOCAL STOCK NUMBER: CREDIT
| 1.00 |
| EA |
| ____________ |
| _____________ |
Security Entitlement: Customer Hard Drive Retention Robotic System (per robot)
LOCAL STOCK NUMBER: OM*1
| 1.00 |
| EA |
| ____________ |
| _____________ |
Endpoint Security Management (per pharmacy)
LOCAL STOCK NUMBER: OM
| 1.00 |
| EA |
| ____________ |
| _____________ |
Credit for SPX00 or CRSX Robotic Dispensing System Trade-in - SP 50/OCC RD01076-01
LOCAL STOCK NUMBER: TRADE-IN
| 1.00 |
| EA |
| ____________ |
| _____________ |
INSTALLATION
LOCAL STOCK NUMBER: OK931637
| 12.00 |
| EA |
| ____________ |
| _____________ |
SUPPORT
LOCAL STOCK NUMBER: PF369258
| GRAND TOTAL |
| _____________ |
See attached document: S02 36C26224Q0283.
See attached document: Statement of Work SP100.
See attached document: Attachment 1 VA NOTICE OF LIMITATIONS ON SUBCONTRACTING.
Page 1 of