- (CON)(660) Engineering PET Scanner Site Prep Federal contract opportunity
- Solicitation number
- 36C25919R0182
About this file
This federal contract opportunity notice seeks proposals for an engineering PET scanner site prep project at the Salt Lake City Veterans Affairs Medical Center. The project scope includes architectural, electrical, mechanical, plumbing, site investigation, and testing/special inspection services per drawings and specifications to remodel an existing PET scanner room and control room, as well as modification of adjacent spaces totaling approximately 2,200 square feet. Work includes painting, installing lockable casework, shielding, replacing flooring, lighting upgrades, and electrical, HVAC, plumbing, and signal system work. The contractor must provide all necessary site preparation and support work for new PET scanner equipment. The solicitation is set aside for Service Disabled Veteran-Owned Small Businesses with a size standard of $36.5 million. The construction magnitude is estimated between $100,000 and $250,000. Proposals are due on or about August 27, 2019.
36C25919R0182 PN 660-CSI-108 100PCT Stamped - Drawings_REDUCED.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25919R0182-002.pdf | ||
| 36C25919R0182-003.pdf | ||
| 36C25919R0182-004.pdf | ||
| 36C25919R0182-005.docx | DOCX document | |
| 36C25919R0182-001.docx | DOCX document | |
| 36C25919R0182-003.pdf | ||
| 36C25919R0182-005.docx | DOCX document | |
| 36C25919R0182-004.pdf | ||
| 36C25919R0182-001.docx | DOCX document | |
| 36C25919R0182-000.docx | DOCX document | |
| 36C25919R0182-000.docx | DOCX document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
T
A
V a l d e z
D r i v e
K i s t e s
S t r e e t
K i s t e r e e t
W a h l n
W a y
B a k r e e t
H a l r e e t
B e n n i o
B v d
HP
HP
P a t i e
R
V
L t
V a l d i v e
V a l d i v e
R d u t
C e e k
W a h l y
BIKE
RACKS
E
C
U
500 Foothill Drive
M a r i p e c c h i i v e
V
A
NA
C
C
E
S
S
IB
LE
V
A
NA
C
C
E
S
S
IB
LE
W a k a y
Sunnyside Avenue (8th South)
D
F o o t h i i v e
H a r e e t
T
T
K i s t e r e e t
B a k r e e t
B e n n i v d
HP
HP
C
U
500 Foothill Drive
V
A
N
A
C
C
E
S
S
I
B
L
E
V
A
NA
C
C
E
S
S
I
B
L
E
D
AREA OF WORKVICINITY MAP SHEET INDEX
SALT LAKE CITY VETERANS AFFAIRS MEDICAL CENTER
SALT LAKE CITY, UTAH
VAMC PROJECT #: 660-CSI-108
PET SCANNER SITE PREP
06/13/2019 MVP SD
GI001
COVER SHEET
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
AREA OF WORK
BUILDING 1
T r u e
N o r t h
T r u e
N o r h
View Name
1/8" = 1'-0"
SECTION, DETAIL, OR ELEVATION TITLE EXAMPLE
ELEVATION CALLOUT EXAMPLE
DETAIL CALLOUT EXAMPLE
SECTION CALLOUT EXAMPLE
SECTION, DETAIL, OR ELEVATION
SYMBOL IDENTIFIERS
DETAIL NAME
LETTER OR NUMBER DESIGNATOR
DRAWING SEQUENCE NUMBER
INDICATES WHERE TITLE IS
LOCATED
ONE OR TWO CHARACTER
DISCIPLINE DESIGNATOR (MAY
NOT BE PRESENT IF CALLOUT
AND TITLE ARE ON DRAWINGS
WITHIN THE SAME DISCIPLINE)
A
A101
AE101
AE101
AE101
W-3
P2
RB3
DOOR NUMBER TAG
WALL TYPE TAG
WINDOW TYPE TAG
CENTER LINE
WALL FINISH TAG
A
COLUMN BUBBLE
ROOM TAG
WALL COLOR
BASE TYPE /
COLOR
MATCH LINE
DETAIL NUMBER
ON SHEET
SHEET NUMBER
DETAIL NUMBER
ON SHEET
SHEET NUMBER
NEW LINE TYPE.
EXISTING LINE TYPE.
DEMO LINE TYPE.
ROOM NAME
DEMO HATCH TYPE.
FIRE RESISTIVE RATED WALL, 1 HOUR
FIRE RESISTIVE RATED WALL, 2 HOUR
FIRE RESISTIVE RATED WALL, 3 HOUR
FIRE RESISTIVE RATED WALL, 4 HOUR
S
S
S
S
FIRE RATED, SMOKE BARRIER WALL, 1 HOUR
FIRE RATED, SMOKE BARRIER WALL, 1 HOUR
FIRE RATED, SMOKE BARRIER WALL, 1 HOUR
FIRE RATED, SMOKE BARRIER WALL, 1 HOUR
2'-0" 2'-2"
M A
X
0'-10"
MAX.
2'-6"
M A
X
M I N
M I N
M I N
M A
X
1'-5"
MIN.
M I N
4'-0"
MIN.
19"
MAX.
MIRROR
CLEAR
FLOOR
SPACE
MAX.
0' - 6"
0'-8"
MIN.
1'-5"
MIN.
MIRROR
M A
X
M I N
M I N
0'-6"
MAX.
0'-8"
MIN.
T
O
1'-0"
MAX.
T
O
3'-6"
MIN.
3'-0"
TOILET PAPER
1'-6"
TYP.
1'-0"1'-0"
3'-0"
MIN.
T
O
T
O
(H) ACCESSIBLE TOILET WITH GRAB BAR (I) ACCESSIBLE TOILET WITH GRAB BAR
1'-6" MIN.
2'-0" PREFERRED
M
I N
PULL SIDE
PUSH SIDE
(D) FRONT APPROACHES - SWING DOORS
M
I N
4'-0" MIN. IF
DOOR HAS
BOTH LATCH
AND CLOSER
MIN.
1' - 0"
* IF DOOR HAS BOTH A
CLOSER AND LATCH
W I D
T H
CLR. LENGTH
IF WIDTH IS 5', CLR. LENGTH IS 3'-0" MIN.
IF WIDTH IS 4'-6", CLR. LENGTH IS 3'-6" MIN.
M I N
4'-6"
MIN.
4'-0" MAX. IF DOOR
HAS BOTH A CLOSER
AND LATCH.
(G) HINGE-SIDE APPROACHES - SWING DOORS
M
I N
2'-0"
MIN.
4'-6" MIN. IF DOOR
HAS CLOSER
(K) LATCH-SIDE APPROACHES - SWING DOORS
2'-0"
MIN.
4'-0" MIN. IF
DOOR HAS
BOTH A LATCH
AND CLOSER
(A) CLEAR FLOOR SPACE, PARALLEL APPROACH (B) HIGH AND LOW SIDE REACH
(C) MAXIMUM SIDE REACH
OVER OBSTRUCTIONS
(E) LAVATORY CLEARANCES (F) DRINKING FOUNTAIN SPOUT HEIGHT
AND KNEE CLEARANCES
(J) ROLL-IN SHOWER WITH FOLDING SEAT
M I N
2'-0"
MIN.
3'-0"
MIN.
DRAIN
NAPKIN DISPOSAL
SYMBOLS LEGENDABBREVIATIONS GENERAL NOTES
06/13/2019 MVP SD
GI002
GENERAL INFORMATION
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
& AND
@ AT
AB ANCHOR BOLT
ACFL ACCESS FLOOR
ACOUS ACOUSTICAL
AD AREA DRAIN
ADJ ADJUSTABLE
ADJT ADJACENT
ADMIN ADMINISTRATION
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
AP ACCESS PANEL
APROX APPROXIMATE
ARCH ARCHITECTURAL
AT ACOUSTICAL CEILING TILE
AUTO AUTOMATIC
AWT ACOUSTICAL WALL TREATMENT
BD BOARD
BFE BOTTOM FOOTING ELEVATION
BG BUMPER GUARD
BKT BRACKET
BLDG BUILDING
BM BEAM
BOT BOTTOM
BP BRICK PAVING
BR BRICK
BRG BEARING
BSMT BASEMENT
C CHANNEL
CAB CABINET
CANTL CANTILEVER
CAP CAPACITY
CAT CATEGORY
CCTV CLOSED CIRCUIT TELEVISION
CD COILING DOOR
CG COILING GRILLE
CGD CORNER GUARD
CH COAT HOOK
CJT CONTROL JOINT
CL CENTER LINE
CLS CLASS
CLG CEILING
CLR CLEAR
CM CONSTRUCTION MANAGER
CMU CONCRETE MASONRY UNIT
CO CASED OPENING
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONN CONNECT/-ED/-ION
CONST CONSTRUCTION
CONT CONTINUE/CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CP CARPET
CPT CARPET MODULE TILE
CR-1 CHAIR RAIL
CR-2 CRASH RAIL
CT CERAMIC TILE
CTR CENTER
CW CURTAIN WALL
CWR COLD WATER
CYL CYLINDER
D DEPTH OR DEEP
DEMO DEMOLITION
DEPR DEPRESSION
DBL DOUBLE
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DIST DISTRIBUTION
DIV DIVISION
DN DOWN
DP DATA PROCESSING
DR DOOR
DS DOWNSPOUT
DWG DRAWING
ELC ELECTRICAL CABINET
EC EPOXY COATING
EF EXHAUST FAN
EFTR EXISTING FINISH TO REMAIN
EJT EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EMERG EMERGENCY
EO ELECTRICAL OUTLET
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXH EXHAUST HOOD
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
EXT-P EXTERIOR PAINT
EXT-ST EXTERIOR STAIN
FA FIRE ALARM
FAP FIRE ALARM PANEL
FB FIRE BLANKET
FD FLOOR DRAIN
FDN FOUNDATION
FDV FIRE DEPARTMENT VALVE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FGS FOAM GASKET SEAL
FH FIRE HOSE
FHV FIRE HOSE VALVE
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FL FLOW LINE
FP FIRE PROOFING
H HIGH
HB HOSE BIB
HD HAND DRYER
HDCP HANDICAP
HDR HEADER
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HPT HIGH POINT
HR HANDRAIL
HT HEIGHT
HTR HEATER
HVAC HEATING, VENTILATING,
AIR CONDITIONING
HW HOT WATER
HWD HARDWOOD
ICB INTEGRAL COVE BAS
ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
ISO ISOLATION
JAN JANITOR
JB JUNCTION BOX
JST JOIST
JT JOINT
KO KNOCK OUT
L LAVATORY
LB POUND
LCD LINEAR CEILING DIFFUSER
LF LINE FIGURED
LIN LINEAR
LKR LOCKER
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMC LINEAR METAL CEILING
LOC LOCATION OR LOCATE
LPT LOW POINT
LS LAWN SPRINKLING
LT LIGHT
LTG LIGHTING
LVR LOUVER
LWC LINEAR WOOD CEILING
MAT MATERIAL
MAX MAXIMUM
MBD MARKER BOARD
MC MEDICINE CABINET
MCU MODULAR COOLING UNIT
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MRF MANUFACTURER
MH MANHOLE
MIL MILLIMETER
MN MINIMUM
MR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MONO MONOLITHIC
MPU MULTI- PURPOSE UNIT
MTD MOUNTED
MTL METAL
MTR MOTOR
MULL MULLION
PNL PANEL
PR PAIR
PRELIM PRELIMINARY
PRES PLASTIC RESIN
PRESS PRESSURE
PRIM PRIMARY
PROJ PROJECTION
PRV POWER ROOF VENTILATOR
PT PAINT
PTR PRINTER
PVC POLYVINYL CHLORIDE
R RADIUS
RI RISER
RA RETURN AIR
RB RESILIENT BASE/RUBBER BASE
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REIN REINFORCE/-ED/-ING
REM REMOVE
REQD REQUIRED
RET RETAINING
REVS REVERSE
REV REVISE
RF RESILIENT FLOOR
RFI REQUEST FOR INFORMATION
RH ROOF HATCH
RM ROOM
RO ROUGH OPENING
RS ROUGH SLAB
RSF RESILIENT SHEET FLOOR
RWC RAIN WATER CONDUCTOR
SI SINK
SCHED SCHEDULE
SD SHOWER DRAIN
SDR SMOKE DAMPER
SDISP SOAP DISPENSER
STF STORE FRONT
SF SQUARE FOOT
SH SHOWER
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SM SURFACE MOUNTED
SNC SANITARY NAPKIN CABINET
SND SANITARY NAPKIN DISPOSER
SP STANDPIPE
SPEC SPECIFICATIONS
SPR SINGLE PLY ROOF
SQ SQUARE
SQ YD SQUARE YARD
SR SERVICE RECEPTOR
SS SERVICE SINK
SST STAINLESS STEEL
STR STREET
ST STAIN
STC SOUND TRANSMISSION
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURAL
T TOP
TAN TANGENT
TCAB TOWEL CABINET
TDR TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TG TONGUE & GROVE
THRES THRESHOLD
TOIL TOILET
TPH TOILET PAPER HOLDER
TR TREAD
TRANSF TRANSFORMER
TS TUBE SECTION
TV TELEVISION
TYP TYPICAL
U URINAL
UCT UNDERCUT
UCR UNDERCOUNTER
UFD UNDER FLOOR DUCT
UG UNDERGROUND
UH UNIT HEATER
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
US UTILITY SHELF
UTIL UTILITY
VIF VERIFY IN FIELD
VC VALVE CABINET
VCT VINYL COMPOSITION TILE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
W WIDTH/WIDE
WF WIDE FLANGE
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WDW WINDOW
WG WALL GUARD
WH WALL HYDRANT
WHCH WHEELCHAIR
WHTR WATER HEATER
WPL WALL PANEL
WP WATERPROOF
WR WASTE RECEPTACLE
WS WEATHERSTRIP
WSCT WAINSCOT
WSF WELDED SEAM-RESILIENT
SHEET FLOORING
WDT WINDOW TREATMENT
WT WEIGHT
WW WOOD WINDOW
WWF WELD WIRE FABRIC
NA NOT APPLICABLE
NC NURSE CALL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NT NOTE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OVERHEAD
OP OPERABLE PARTITION
OPER OPERATOR
OPNG OPENING
OPP OPPOSITE
OFD OVERFLOW ROOF DRAIN
FRMG FRAMING
FSTOP FIRE STOPPING
FT FOOT/FEET
FTG FOOTING
FURR FURRING
GA GAUGE
GAL GALLONS
GALV GALVANIZED
GB GRAB BAR
GBM GRADE BEAM
GC GENERAL CONTRACTOR
GENL GENERAL
GENR GENERATOR
GL GLASS
GR GRADE
GRT GROUT
GWB GYPSUM WALLBOARD
GYP GYPSUM
P PAINT
PART PARTITION
PB PUSH BUTTON
PC PRECAST CONCRETE
PCD PAPER CUP DISPENSER
PED PEDESTAL
PLT PLATE
PROP PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLS PLASTER
PLW PLYWOOD
ACCESSIBILITY GUIDELINES
CODE DATA
COR CONTRACTING OFFICER'S
REPRESENTATIVE
1. ALL CONTRACTORS AND THEIR SUPERVISORY PERSONNEL MUST REVIEW THE GENERAL AND
SUPPLEMENTARY CONDITIONS TO THE CONTRACT.
2. ALL WORK MUST CONFORM WITH APPLICABLE BUILDING CODES, REGULATIONS AND ORDINANCES.
3. CONTRACTOR MUST OBTAIN ALL REQUIRED BUILDING AND OCCUPANCY PERMITS.
4. CONTRACTOR MUST BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO THE WORK.
5. CONTRACTOR MUST BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND THE SAFETY OF ALL CONSTRUCTION PERSONNEL AND VISITORS.
6. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE CONTRACTOR.
7. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK WILL BE INSTALLED AND REPORT TO THE CONTRACTOR AND VA COR IN WRITING ANY CONDITIONS DETRIMENTAL TO
THE PROPER AND TIMELY EXECUTION OF THAT INSTALLER'S WORK. DO NOT PROCEED UNTIL
UNSATISFACTORY CONDITIONS ARE CORRECTED. COMMENCING WITH INSTALLATION WILL CONSTITUTE
ACCEPTANCE OF THE SUBSTRATE AND/OR CONDITIONS.
8. DO NOT SCALE DRAWINGS: FOLLOW WRITTEN DIMENSIONS AND NOTES. CONTACT COR FOR CLARIFICATIONS, IF REQUIRED.
9. DIMENSIONS SHOWN ON THE FLOOR PLAN ARE TO THE FACE OF GYP. BOARD/ WALL (FOG), FACE OF MASONRY (FOM), FACE OF CONCRETE WALLS (FOC) AND COLUMN GRID LINES, UNLESS OTHERWISE NOTED OR
INDICATED.
10. NOTE: WALL THICKNESSES ARE NOMINAL DIMENSIONS, NOT ACTUAL DIMENSIONS. ALL STUD WALL
THICKNESSES ARE 5 INCHES, UNLESS DIMENSIONED OTHERWISE.
11. ALL MASONRY WALL THICKNESSES ARE 8 INCHES, UNLESS DIMENSIONED OR OTHERWISE NOTED.
12. "TYPICAL", AS USED IN THESE DOCUMENTS, MEANS THAT THE CONDITION OR DIMENSION IS REPRESENTATIVE
OF, OR THE SAME, FOR SIMILAR CONDITIONS THROUGHOUT.
13. IF THERE IS A DISCREPANCY BETWEEN SMALL SCALE AND LARGE SCALE DRAWINGS, (PLAN, SECTION & DETAIL DRAWINGS, ETC.), CONTACT COR FOR CLARIFICATION. FOR BIDDING PURPOSES: THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS MUST GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION, THE MOST
EXPENSIVE AND/OR STRICTEST REQUIREMENTS, AS INDICATED BY THE COR, MUST GOVERN.
14. IF THERE ARE ANY DISCREPANCIES BETWEEN THE DRAWINGS AND SPECIFICATIONS, CONTACT COR FOR CLARIFICATION. FOR BIDDING PURPOSES: THE MOST EXPENSIVE AND/OR STRICTEST REQUIREMENTS MUST GOVERN. FOR CLARIFICATIONS DURING CONSTRUCTION: THE MOST EXPENSIVE AND/OR STRICTEST
REQUIREMENTS, AS INDICATED BY THE COR, MUST GOVERN.
15. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS MUST BE REPORTED TO THE COR IN
WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK.
16. ANY AND ALL DISCREPANCIES MUST BE REPORTED TO THE COR IN WRITING FOR RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK. IN THESE INSTANCES, NO CHANGE ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR ACCEPTED FOR PROCEEDING WITH THE WORK WITHOUT THE COR'S WRITTEN DIRECTION AND APPROVAL. ALSO, CONTRACTOR MUST REPAIR AND/OR REPLACE ANY UNAUTHORIZED WORK, AS INDICATED
BY THE COR, AT NO ADDITIONAL COST TO THE OWNER.
17. ALL DISSIMILAR METAL MATERIALS MUST BE ISOLATED WITH AN APPROVED NONMETAL ISOLATION MATERIAL.
18. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALL PANELS AND AT PENETRATIONS OF UTILITIES THROUGH THE BUILDING ENVELOPE, ETC, MUST BE SEALED, CAULKED, FLASHED OR WEATHER-STRIPPED, AS REQUIRED, FOR COMPATIBILITY WITH ADJACENT MATERIALS
AND TO ELIMINATE AIR LEAKAGE AND WATER ENTRY.
19. PROVIDE SEALANT AND/OR CAULKING BETWEEN DISSIMILAR ADJOINING INTERIOR MATERIALS. (I.E. WINDOW
SILLS TO GYP. BD., ACT CEILINGS TO MASONRY WALLS, ETC.)
20. DOOR OPENINGS NOT LOCATED BY DIMENSION MUST BE CENTERED IN WALL SHOWN OR LOCATED 2 INCHES FROM FINISH WALL TO FINISH JAMB, ALWAYS ALLOWING A MINIMUM OF 18" FROM THE PULL SIDE OF THE DOOR
TO THE INTERSECTING WALL.
21. CONTRACTOR MUST VERIFY THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES AND THEIR SERVICE
CONNECTIONS WITH THE PROPER UTILITY COMPANY.
22. CONTRACTOR MUST COORDINATE SIZE, LOCATIONS AND NUMBER OF ALL ROOF OPENINGS AND ROOF ACCESSORIES WITH ALL OTHER TRADES. REFER TO THE ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS.
23. LOCATIONS AND SIZES OF ALL CONCRETE MECHANICAL AND ELECTRICAL PADS MUST BE COORDINATED BY THE MECHANICAL AND ELECTRICAL CONTRACTORS, WITH THE SELECTED EQUIPMENT MANUFACTURER/SUPPLIER
AND ARE TO BE APPROVED BY THE COR PRIOR TO PROCEEDING WITH THE WORK.
24. EXCEPT AT FIRE-RATED PARTITIONS, ALL WALL AND COLUMN GYPSUM BOARD FACING MUST BE HELD AT 5/8
INCH BELOW STRUCTURE, UNLESS DETAILED OR NOTED OTHERWISE.
25. AT ALL TELECOMMUNICATION ROOMS: PROVIDE 3/4" X 8'-0" HIGH FIRE-RETARDANT-TREATED WOOD SHEATHING OR PROVIDE PLYWOOD OVER NON-COMBUSTIBLE SHEATHING, BOTTOM TO BE LOCATED AT 4" A.F.F. VERIFY
LENGTHS AND LOCATIONS WITH ELECTRICAL DRAWINGS.
26. GLASS DOORS, ADJACENT PANELS AND ALL GLAZED OPENINGS WITHIN 1'-6" OF THE FLOOR, AND WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF A DOOR, ETC., MUST BE SAFETY GLAZING AS APPROVED FOR
IMPACT BY APPLICABLE BUILDING CODES, AND MUST BE LABELED AS SUCH.
27. ALL CEILING HEIGHTS AS SHOWN ON PLANS AND DETAILS ARE FROM SLAB OR TILE FLOOR (FINISHED FLOOR) TO
FINISHED CEILING.
28. PROVIDE INDEPENDENT FRAMING AND ATTACHMENTS TO THE STRUCTURE, ADEQUATE TO SUPPORT THE CEILING SYSTEM, LIGHT FIXTURES, DUCTS, DIFFUSERS, SPRINKLER PIPING AND BUS DUCTS.
29. ALL CLOSETS AND ALCOVES WITHOUT A SPACE IDENTIFICATION NUMBER MUST HAVE THE SAME FINISHES AS
ADJOINING SPACES.
30. CONTRACTOR TO INSTALL WOOD BLOCKING AND PLYWOOD, AS REQUIRED, FOR THE MOUNTING OF ALL TOILET ACCESSORIES, MILLWORK/ CASEWORK, AV EQUIPMENT, MEP ITEMS AND RADIOLOGY EQUIPMENT, ETC.
31. REFER TO SPECIFICATIONS FOR ALL REQUIRED TESTING AND INSPECTIONS.
32. ANY/ ALL PROPRIETARY PRODUCTS DESCRIBED AND/OR DRAWN IN THE DOCUMENTS (BUT NOT SPECIFIED) ARE TO MEET THE MANUFACTURER'S STANDARD CRITERIA WHICH IS NOT LIMITED TO THE FOLLOWING:
PERFORMANCE REQUIREMENTS, QUALITY ASSURANCE REQUIREMENTS, APPLICABLE CODES AND INDUSTRY STANDARDS, FABRICATION, ASSEMBLY, HANDLING, DELIVERY, STORAGE, INSTALLATION, OPERATION, ADJUSTMENTS, ETC. PROVIDE THE MANUFACTURER'S STANDARD WARRANTY AND STANDARD FINISH WARRANTY. PROVIDE PRODUCT DATA, SHOP DRAWINGS, SAMPLES AND MAINTENANCE DATA, AS REQUIRED.
REFER TO DIVISION 01 SPEC. SECTIONS WHICH ALSO APPLY, SUCH AS SUBSTITUTION PROCEDURES, SUBMITTAL PROCEDURES, QUALITY REQUIREMENTS, REFERENCES, EXECUTION AND CLOSEOUT PROCEDURES.
NOTE: ANY SUBSTITUTIONS MUST MEET THE DESIGN INTENT, AS WELL AS THE CRITERIA DESCRIBED ABOVE.
33. ALL EXTERIOR EXPOSED STEEL MUST BE PAINTED.
CONSTRUCTION SAFETY RISK ASSESSMENT CHECKLIST
06/13/2019 MVP SD
GI003
CONSTRUCTION SAFETY RISK
ASSESSMENT CHECKLIST
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
FOR
REFERENCE
ONLY
INTERIM LIFE SAFETY MEASURES (ILSM) ASSESSMENT
GI004
ILSM AND ICRA
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
INFECTION CONTROL RISK ASSESSMENT (ICRA)
FOR
REFERENCE
ONLY
34A3433A31A
T Q1
S R
P
A. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL
DEMO INFORMATION.
B. GENERAL CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE CONTRACTING OFFICER'S REPRESENTATIVE (COR)
BEFORE PROCEEDING WITH WORK.
C. INFECTION CONTROL BARRIERS TO BE 3-5/8" METAL STUDS WITH (1) ONE LAYER OF
GYP. BD. EACH SIDE. MUD TAPE & PAINT. PROVIDE TEMPORARY HOLLOW METAL
DOOR AND H.M. FRAME.
D. PER NFPA 241 (2013) PARAGRAPH 8.6.2, IN ROOMS WHERE CEILINGS ARE REMOVED,
TEMPORARY UPRIGHT SPRINKLERS MUST BE INSTALLED UNTIL FINISHED CEILING IS
REPLACED AND NEW SPRINKLERS ARE INSTALLED.
DEMO EXISTING WALL AND ALL ASSOCIATED CONSTRUCTION. REFER TO ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION REGARDING ELECTRICAL DEMOLITION.
DEMO OF EXISTING SCANNER AND EQUIPMENT BY OTHERS.
DEMO EXISTING DOOR, FRAME AND ASSOCIATED CONSTRUCTION.
DEMO OF CONTROL EQUIPMENT BY OTHERS.
DEMO EXISTING RESILIENT SHEET FLOORING AND INTEGRAL COVE BASE AND PREP SUB
FLOOR FOR NEW FLOORING.
DEMO EXISTING CASEWORK AND COUNTERTOPS.
REMOVE EXISTING LOCKERS AND RETURN TO MEDICAL CENTER.
DEMOLISH EXISTING CABINETS, COUNTERTOP AND SINK. CAP EXISTING WATER SUPPLY
AND SANITARY WASTE LINES IN PLACE.
EXISTING OMNICELL. PROTECT FROM DAMAGE AT ALL TIMES OR COORDINATE WITH
MEDICAL CENTER FOR TEMPORARY RELOCATION.
SAW CUT AND REMOVE EXISTING CONCRETE SLAB, AS REQUIRED, TO ALLOW FOR
INSTALLATION OF ELECTRICAL RACEWAYS AND MECHANICAL PIPING. AFTER INSTALLATION
REPLACE CONCRETE SLAB IN KIND.
DEMO EXISTING MILLWORK, BREATHING APPARATUS AND ALL ASSOCIATED
CONSTRUCTION. SEE MECHANICAL AND ELECTRICAL FOR MORE DEMO INFORMATION.
TEMPORARY INFECTION CONTROL BARRIER. REFER TO ARCHITECTURAL GENERAL NOTE C
FOR MORE INFORMATION.
ARCHITECTURAL GENERAL NOTES - DEMOLITION:
KEY NOTES:
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
DEMOLITION FLOOR PLAN
06/13/2019 MVP MVP
AD101
DEMOLITION FLOOR PLAN
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
KEY PLAN
1E20
PATIENT
DRESSING RM
1E22-1
TREATMENT
PETSCAN
1E18
TREATMENT #01
(114, INJECTION)
1E21
PATIENT PREP
INJECTION
1E19
PATIENT PREP
INJECTION
1E24-1
CONTROL RM
1E24
LAB
1E91
ENTRANCE
(TO UTILITY TUNNEL)1E17
RESTROOM
1E14
LAB/OFFICE
1E16
LAB/OFFICE
1E15
LAB/OFFICE
1EA
STAIR LEVEL
1EAA
ELECTRICAL
1EAB
ENTRY
(UTILITIES)
1EAC
TEL/DATA
1EAD
AUX. SYSTEMS
1E92
EXTRASTITIAL
SPACE
1E94
EXTRASTITIAL
SPACE
NE
W
F
LO
OR
EX
IS
T'G
F
LO
OR
NE
W
F
LO
OR
EX
IS
T'G
F
LO
OR
North
Plan T r
N r t h
HALL
Q1
S R
P
EXISTING 2x4 LIGHTS TO REMAIN.
EXISTING CEILING GRID AND TILES TO REMAIN. PROTECT FROM DAMAGE AT ALL TIMES.
DEMOLISH EXISTING CEILING GRID AND TILES.
DEMOLISH EXISTING LIGHTS. SEE ELECTRICAL FOR MORE INFORMATION.
EXISTING EXHAUST GRILLES TO REMAIN.
DEMOLISH EXISTING DIFFUSERS. SEE MECHANICAL FOR MORE INFORMATION.
REMOVE AND STORE EXISTING DIFFUSER TO BE REUSED AND RELOCATED.
EXISTING SPRINKLER HEADS TO REMAIN.
DEMOLISH EXISTING SPRINKLER HEAD.
EXISTING MED GAS OUTLETS TO REMAIN.
TEMPORARY INFECTION CONTROL BARRIER. REFER TO ARCHITECTURAL GENERAL NOTE C
FOR MORE INFORMATION.
EXISTING MECHANICAL DIFFUSER TO REMAIN.
EXISTING 2x4 LIGHTS TO BE RELOCATED. PROTECT FROM DAMAGE AT ALL TIMES.
KEY NOTES:
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
DEMOLITION REFLECTED CEILING PLAN
06/13/2019 MVP SD
AD201
DEMOLITION REFLECTED
CEILING PLAN
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
KEY PLAN
1E20
PATIENT
DRESSING RM
1E22
TREATMENT
PETSCAN
1E18
PATIENT PREP
INJECTION
1E21
PATIENT PREP
INJECTION
1E19
PATIENT PREP
INJECTION
1E24
CONTROL RM
1E24
LAB
1E17
RESTROOM
1E14
LAB/OFFICE 1E16
LAB/OFFICE
1E15
LAB/OFFICE
1EA
STAIR LEVEL
1EAA
ELECTRICAL
1EAB
ENTRY
(UTILITIES)
1EAC
TEL/DATA
1EAD
AUX. SYSTEMS
1E92
EXTRASTITIAL
SPACE
1E94
EXTRASTITIAL
SPACE
1E91
ENTRANCE
(TO UTILITY TUNNEL)
12 5
North
Plan
T r r t h
6 7
HALL
A. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL
DEMO INFORMATION.
B. GENERAL CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE CONTRACTING OFFICER'S REPRESENTATIVE (COR)
BEFORE PROCEEDING WITH WORK.
C. PER NFPA 241 (2013) PARAGRAPH 8.6.2, IN ROOMS WHERE CEILINGS ARE REMOVED,
TEMPORARY UPRIGHT SPRINKLERS MUST BE INSTALLED UNTIL FINISHED CEILING IS
REPLACED AND NEW SPRINKLERS ARE INSTALLED.
ARCHITECTURAL GENERAL NOTES - DEMOLITION:
3433A
T Q1
S R
P
T S
A. GENERAL CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE COR BEFORE PROCEEDING WITH WORK.
B. REFER TO SHEET AD101 FOR LOCATION AND TYPE OF TEMPORARY INFECTION
CONTROL CONSTRUCTION BARRIER.
NEW IMAGING SCANNER BY OTHERS.
NEW BUILT-IN COUNTERTOP. PROVIDE WIRING GROMMETS @ 4'-0" O.C.
SCANNER EQUIPMENT AND CONTROLS BY OTHERS.
NEW CABINETS WITH SOLID SURFACE COUNTERTOP.
ALIGN WITH EXISTING WALL. FINISH FLUSH AND SMOOTH.
LINE OF NEW SOFFIT ABOVE.
PROVIDE NEW RESILIENT SHEET VINYL FLOORING. COLOR AND PATTERN TO BE SELECTED BY
MEDICAL CENTER INTERIORS STAFF.
12" SOILED LINEN DROP.
8" TRASH DROP.
PROVIDE NEW 1/4" LEAD SHIELDING. CONTRACTOR MUST PROVIDE VERIFICATION TO THE COR
OF STRUCTURAL CAPACITY OF EXISTING METAL STUD FRAMING TO SUPPORT NEW LEAD
SHIELDING AND PROVIDE NEW OR REINFORCED FRAMING AS REQUIRED. CONTRACTOR MUST
COORDINATE ALL WORK ASSOCIATED WITH INSTALLATION OF LEAD SHIELDING WITH THE COR
INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, MILLWORK AND ARCHITECTURAL
FINISHES SUCH AS FLOORING, CEILING AND WALL BOARD. ETC.
ARCHITECTURAL GENERAL NOTES:
KEY NOTES:
06/13/2019 MVP MVP
A-101
FLOOR PLAN
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
KEY PLAN
SCALE: 1/2" = 1'-0"
6" 1' 2' 4' 8'0
ENLARGED DIMENSION FLOOR PLAN
1E20
PATIENT
DRESSING RM
1E22-1
TREATMENT
PETSCAN
1E18
TREATMENT #01
(114, INJECTION)
1E21
PATIENT PREP
INJECTION
1E19
PATIENT PREP
INJECTION
1E24-1A
CONTROL RM
1E24
LAB
1E91
ENTRANCE
(TO UTILITY TUNNEL)1E17
RESTROOM
1E14
LAB/OFFICE
1E16
LAB/OFFICE
1E15
LAB/OFFICE
1EA
STAIR LEVEL
1EAA
ELECTRICAL
1EAB
ENTRY
(UTILITIES)
1EAC
TEL/DATA
1EAD
AUX. SYSTEMS
1E92
EXTRASTITIAL
SPACE
1E94
EXTRASTITIAL
SPACE
1E24-1B
EQUIPMENT
ROOM 1
1E24-1C
EQUIPMENT
ROOM 2
1E24-1B1
1E24-1B2
1E24-1C1
E
A
6'-11 1/8"
4'-5 1/8"2'-6"
'-4
1/ 2"
3'-4" 11" 8"3'-10"
1E24-1B
EQUIPMENT
ROOM 1
1E24-1A
CONTROL RM
1E24-1C
EQUIPMENT
ROOM 2
1'- 8 1
/4" 6'-
2 1 /4"
6'- 4"
1 1 /2"
3'-
3 1
/4"
3'-0"
45°
3'- 7 1
/2" 2'-
0 1 /4"
1 1 /2"
4'-4"
3'- 0"
1'- 4"
1'-4"
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
FLOOR PLAN
A-101
1E00A
CORRIDOR
1E00A
CORRIDOR
1E00A
CORRIDOR
1E00A
CORRIDOR
NE
W
F
LO
OR
EX
IS
T'G
F
LO
OR
NE
W
F
LO
OR
EX
IS
T'G
FL
OO
R
NE
W
F
LO
OR
EX
IS
T'G
F
LO
OR
NE
W
FL
OO
R
EX
IS
T'G
F
LO
OR
NEW
FLOOR
EXIST'G
FLOOR
NEW
FLOOR
EXIST'G
FLOOR
North
Plan
T r r t h
North
Plan
T r r t h
1E24-1A2
A-301
A
A2
A2
A1
A A1
A2
A-301
A301
8 9
Q1
S R
P T
Q1 S
R P
34A3433A31A 34A3433A31A A. GENERAL CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT ANY
DISCREPANCIES TO THE COR BEFORE PROCEEDING WITH WORK.
B. ALL NEW CEILINGS TO BE 8'-0" A.F.F. UNLESS NOTED OTHERWISE ON CEILING PLAN.
EXISTING 2x2 CEILING TILE AND GRID TO REMAIN. PROTECT FROM DAMAGE AT ALL TIMES.
REPLACE ANY DAMAGED TILES IN KIND.
EXISTING 2x4 FIXTURES TO REMAIN. PROTECT FROM DAMAGE AT ALL TIMES.
NEW 2x2 CEILING TILE AND GRID.
NEW 2x4 LIGHT FIXTURE. REFER TO LIGHTING PLAN FOR MORE INFORMATION.
NEW RECESSED CAN LIGHT. REFER TO LIGHTING PLAN FOR MORE INFORMATION.
NEW LIGHT FIXTURE. REFER TO LIGHTING PLAN FOR MORE INFORMATION.
RELOCATED EXISTING DIFFUSERS.
NEW SPRINKLER HEAD. SEE FP-101 FOR MORE INFORMATION.
NEW CEILING TILE TO MATCH EXISTING.
ADJUST EXISTING CEILING GRID AS REQUIRED FOR ADDED LEAD SHIELDING THICKNESS.
COORDINATE ALL WORK WITH COR.
CEILING MOUNTED PATIENT LIFT BY OTHERS.
ARCHITECTURAL GENERAL NOTES
KEY NOTES:
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
REFLECTED CEILING PLAN
06/13/2019 MVP SD
A-201
REFLECTED CEILING PLAN
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
KEY PLAN
1E20
PATIENT
DRESSING RM
1E18
PATIENT PREP
INJECTION
1E21
PATIENT PREP
INJECTION
1E19
PATIENT PREP
INJECTION
1E24
CONTROL RM
1E24
LAB
1E17
RESTROOM
1E94
EXTRASTITIAL
SPACE
1E14
LAB/OFFICE 1E16
LAB/OFFICE
1E15
LAB/OFFICE
1EA
STAIR LEVEL
1EAA
ELECTRICAL
1EAB
ENTRY
(UTILITIES)
1EAC
TEL/DATA
1EAD
AUX. SYSTEMS
1E92
EXTRASTITIAL
SPACE
1E91
ENTRANCE
(TO UTILITY TUNNEL)
1E22
TREATMENT
PETSCAN
1 3
North
Plan
T r r t h
A-502
8'-0"
9'-0"
1E00A
CORRIDOR
9 TYP.
A-301
A-301
A-301
A-301
A-301
A-301
A-301
2'- 6"
7'- 0"
4'- 2"
4"
1'-0"
2'-0" 3/4"
3"
2'- 6"
3'- 0"
1 1 /2"
4"
4"
1'- 6"
1'-0"
4"
2"
2'- 6"
3'- 0"2'-
6" 4"
1 1 /2"
2'-0" 3/4"
3'- 0"
4" 2'-
6" 1 1
/2"
4"
1 1 /2"
3'- 0"
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
06/13/2019 MVP SD
A-301
INTERIOR ELEVATIONS
SOLID SURFACE
COUNTERTOP
PREFAB 24"x18"
COUNTER
SUPPORT BRACKET
NEW DOOR AND FRAME
IN EXISTING OPENING.
SEE DOOR SCHEDULE
EXISTING SHIELDED
GLASS
PAINTED HOLLOW METAL
WINDOW FRAME
1'-0"
SCHEDULED BASE
3'-0"
SHIELDED GLASS
SCHEDULED BASE
SOLID SURFACE
COUNTERTOP
ADJUSTABLE SHELF WITH
METAL STANDARDS
PLASTIC LAMINATE
FINISHED END
SLOPED TOP
SOAP DISPENSER
PAPER TOWEL
DISPENSER
SCALE:SCALE: 1-1/2" = 1'-0"
6" 1' 2'0
CASEWORK SECTION 5
SCALE: 3/8" = 1'-0"
9" 1'-6" 3' 6' 12'0
INTERIOR ELEVATION @ CONTROL ROOM
SCALE: 3/8" = 1'-0"
9" 1'-6" 3' 6' 12'0
INTERIOR ELEVATION @ CONTROL ROOM
SCALE: 3/8" = 1'-0"
9" 1'-6" 3' 6' 12'0
INTERIOR ELEVATION CABINETS
SCALE: 3/8" = 1'-0"
9" 1'-6" 3' 6' 12'0
INTERIOR ELEVATION @ TREATMENT ROOM
SCALE:SCALE: 1-1/2" = 1'-0"
6" 1' 2'0
CASEWORK SECTION 6
SCALE:SCALE: 1-1/2" = 1'-0"
6" 1' 2'0
CASEWORK SECTION 7
SCALE:SCALE: 1-1/2" = 1'-0"
6" 1' 2'0
CASEWORK SECTION 8
SCALE:SCALE: 1-1/2" = 1'-0"
6" 1' 2'0
CASEWORK SECTION 9
W36 W36 W36 W36 W36 W24
2" FILLER PANEL WOOD BLOCKING. TYP.
SCHEDULED BASE
SOLID SURFACE
COUNTERTOP
SUPPORT BRACKETS
@ 48" O.C. MAX.
SOLID SURFACE
BACKSPLASH, TYP.
WOOD BLOCKING. TYP.
SOLID SURFACE
COUNTERTOP
PREFAB
POLYSTYRENE TOE
KICK MOULDING
PLAM 1
SCHEDULED BASE
WOOD BLOCKING. TYP.
MELAMINE ADJ. SHELF
PLAM 1
SCHEDULED BASE
3/4" SOLID SURFACE
BACKSPLASH, TYP.
WOOD BLOCKING. TYP.
SOLID SURFACE
COUNTERTOP
MELAMINE ADJ. SHELF
PLAM 1
SCHEDULED BASE
PLAM 1
PLAM 1 SLOPED TOP
PER ELEVATION
SOLID SURFACE
BACKSPLASH, TYP.
WOOD BLOCKING. TYP.
SOLID SURFACE
COUNTERTOP
PLAM 1
SCHEDULED BASE
PLAM 1
PLAM 1 SLOPED TOP
PER ELEVATION
4" S.S. WIRE PULL
4" S.S. WIRE PULL
4" S.S. WIRE PULL
4" STAINLESS STEEL WIRE PULL
7'- 0"
2'- 6"
4"
2'- 6"
6'- 0"
4"
4" S.S. WIRE PULL
2'-
2'-
P-LAM CABINETS WITH
ADJUSTABLE SHELVES AND
4" WIRE PULLS
P-LAM FINISHED END PANEL
2'-
6" 4'-
2" 4"
1'-0"
TOP CABINETS DIVIDED VERTICALLY
Q1
S R
P
06/13/2019 MVP SD
A-401
FLOOR FINISH PLAN
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
KEY PLAN
1E20
PATIENT
DRESSING RM
1E22-1
TREATMENT
PETSCAN
1E18
TREATMENT #01
(114, INJECTION)
1E21
PATIENT PREP
INJECTION
1E19
PATIENT PREP
INJECTION
1E24-1A
CONTROL RM
1E24
LAB
1E91
ENTRANCE
(TO UTILITY TUNNEL)1E17
RESTROOM
1E14
LAB/OFFICE
1E16
LAB/OFFICE
1E15
LAB/OFFICE
1EA
STAIR LEVEL
1EAA
ELECTRICAL
1EAB
ENTRY
(UTILITIES)
1EAC
TEL/DATA
1EAD
AUX. SYSTEMS
1E92
EXTRASTITIAL
SPACE
1E94
EXTRASTITIAL
SPACE
1E24-1B
EQUIPMENT
ROOM 1
1E24-1C
EQUIPMENT
ROOM 2
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
FLOOR FINISH PLAN
1E00A
CORRIDOR
1E00A
CORRIDOR
North
Plan
T r r t h
A. GENERAL CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT
ANY DISCREPANCIES TO THE COR BEFORE PROCEEDING WITH WORK.
B. FLOOR MATERIAL / COLOR TRANSITIONS TO ALIGN W/ ROOM SIDE OF DOOR STOP
UNLESS NOTED OR SHOWN OTHERWISE.
C. CONTRACTOR TO SUBMIT MANUFACTURER'S STANDARD COLORS AND PATTERNS
TO COR FOR APPROVAL.
GENERAL NOTES:
FINISH SCHEDULE
NO. ROOM FLOOR BASE
NORTH
WALLS
EAST
WALLS
SOUTH
WALLS
WEST
WALLS
CEILING REMARKS
WSF1 / MATCH EXISTING
WSF2
WSF3
SVT1
1E22-1
1E22-1
1E24-1A
1E24-1B
1E24-1C
1E00A
TREATMENT PETSCAN
TREATMENT PETSCAN
CONTROL ROOM
EQUIP. ROOM 1
EQUIP ROOM 2
CORRIDOR
WSF 2 ICB GYP GYP GYP GYP
WSF 3 ICB GYP GYP GYP GYP
WSF 2 ICB GYP GYP GYP GYP
SVT 1 RB GYP GYP GYP GYP
SVT 1 RB GYP GYP GYP GYP
WSF 1 ICB GYP GYP GYP GYP
GYP
GYP
ACT
1. SVT1 TO BE ANTI-STATIC MATERIAL.
2. ALL GYPSUM BOARD WALLS TO BE PAINTED WITH SEMI-GLOSS PAINT. CONTRACTOR TO SUBMIT
MANUFACTURER'S STANDARD COLORS TO COR FOR SELECTION BY OWNER.
ACT
ACT
ACT
WSF
SVT
4" WALL BASE PER
SCHEDULE
SVT
SCHLUTER JOLLY, SATIN
NICKEL ANODIZED ALUMINUM
MANUF. STANDARD
COVE FILELR
SHEET VINYL
FLOORING AS SCH.
SCALE: 3" = 1'-0"
INTEGRAL COVE BASE DETAIL
SCALE: 3" = 1'-0"
STRAIGHT BASE DETAIL
SCALE: 6" = 1'-0"
WSF TO VCT TRANSITION
JOHNSONITE CD-XX
SNAP-IN TRANSITION
4 1 /8"
A-501
WALL TYPE SCHEDULE
FLOOR
METAL RUNNERS TOP
AND BOTTOM
6" SOUND BATT INSULATION
(WHERE REQ'D) EXTEND 2'0"
EA DIRECTION FROM FACE OF WALL
INSTALL FIRESAFING INSULATION
TO SEAL TOP OF WALL
(RATED WALLS ONLY)
3 1/2" SOUND BATT
INSULATION
5 1/2" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D
3 5/8" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D
5/8" GYP. BD.
DEEP LEG DEFLECTION/
SLIP TRACK
INSTALL FIRESAFING INSULATION
TO SEAL TOP OF WALL (RATED WALLS ONLY)
PROVIDE BRACING, AS REQ'D, TO STABILIZE
WALL @ 48" O.C. MAX
5/8" LEAD LINED GYP. BD. ON
IR SCAN ROOM SIDE ONLY.
(0.79 MM Pb EQUIV.)
WALL TYPE EWALL TYPE DWALL TYPE B1WALL TYPE A1 WALL TYPE C1
WALL TYPE HWALL TYPE F1 WALL TYPE G WALL TYPE I WALL TYPE J
BOTTOM OF DECK
RE: STRUCTURAL
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
BOTTOM OF DECK
RE: STRUCTURAL
BOTTOM OF DECK
RE: STRUCTURAL
BOTTOM OF DECK
RE: STRUCTURAL
BOTTOM OF DECK
RE: STRUCTURAL
BOTTOM OF DECK
RE: STRUCTURAL
BOTTOM OF DECK
RE: STRUCTURAL
BOTTOM OF DECK
RE: STRUCTURAL
BOTTOM OF DECK
RE: STRUCTURAL
BOTTOM OF DECK
RE: STRUCTURAL
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
CEILING HEIGHT
RE: RCP (WHERE REQ'D)
5/8" GYP. BD. EACH SIDE 5/8" GYP. BD. EACH SIDE
5/8" GYP. BD. EACH SIDE
5/8" GYP. BD. EACH SIDE5/8" GYP. BD.
5/8" GYP. BD.
5/8" GYP. BD.
5/8" GYP. BD.
PROVIDE BRACING, AS REQ'D, TO STABILIZE
WALL @ 48" O.C. MAX
PROVIDE BRACING, AS REQ'D, TO STABILIZE
WALL @ 48" O.C. MAX
PROVIDE BRACING, AS REQ'D, TO STABILIZE
WALL @ 48" O.C. MAX
INSTALL FIRESAFING INSULATION
TO SEAL TOP OF WALL (RATED WALLS ONLY)
6" SOUND BATT INSULATION
(WHERE REQ'D) EXTEND 2'0"
EA DIRECTION FROM FACE
OF WALL
6" SOUND BATT INSULATION
(WHERE REQ'D) EXTEND 2'0"
EA DIRECTION FROM FACE
OF WALL
6" SOUND BATT INSULATION
(WHERE REQ'D) EXTEND 2'0"
EA DIRECTION FROM FACE
OF WALL
3 5/8" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D
3 5/8" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D
3 5/8" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D
3 5/8" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D
METAL RUNNERS TOP
AND BOTTOM
METAL RUNNERS TOP
AND BOTTOM
METAL RUNNERS TOP
AND BOTTOM
METAL RUNNERS TOP
AND BOTTOM
METAL RUNNERS TOP
AND BOTTOM
METAL RUNNERS TOP
AND BOTTOM
METAL RUNNERS TOP
AND BOTTOM
METAL RUNNERS TOP
AND BOTTOM
METAL RUNNERS TOP
AND BOTTOM
3 1/2" SOUND BATT
INSULATION
3 1/2" SOUND BATT
INSULATION
3 1/2" SOUND BATT
INSULATION
3 1/2" SOUND BATT
INSULATION3 1/2" SOUND BATT
INSULATION
5 1/2" SOUND BATT
INSULATION
FLOOR FLOOR FLOOR FLOOR
FLOORFLOOR
FLOOR
FLOORFLOOR
DEEP LEG DEFLECTION/
SLIP TRACK
6" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D 6" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D
6" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D
6" METAL STUD @ 16"
O.C. W/ HORIZ. BRACING
AS REQ'D
5/8" LEAD LINED GYP. BD. ON
IR SCAN ROOM SIDE ONLY.
(0.79 MM Pb EQUIV.)
5/8" LEAD LINED GYP. BD. ON
IR SCAN ROOM SIDE ONLY.
(0.78 MM Pb EQUIV.)
DEEP LEG DEFLECTION/
SLIP TRACK
DEEP LEG DEFLECTION/
SLIP TRACK
DEEP LEG DEFLECTION/
SLIP TRACK
5/8" LEAD LINED GYP. BD.
(0.78 MM Pb EQUIV.)
6" SOUND BATT INSULATION
(WHERE REQ'D) EXTEND 2'0"
EA DIRECTION FROM FACE
OF WALL
PROVIDE BRACING, AS REQ'D, TO STABILIZE
WALL @ 48" O.C. MAX
INSTALL FIRESAFING INSULATION
TO SEAL TOP OF WALL
(RATED WALLS ONLY)
INSTALL FIRESAFING INSULATION
TO SEAL TOP OF WALL
(RATED WALLS ONLY)
TYPE WALL DESCRIPTION
A2 LEAD LINED GYP. AND
1-HOUR RATED U.L. DESIGN
NO. U404
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
M
I N
6" M
IN
1"
LENGTH OF END SPAN
LESSER OF 8" OR 1/4 *
2" MIN.
TYP.
(PANEL FREE TO SLIDE)
3/4" MIN. CLEARANCE
06/13/2019 MVP SD
A-502
CEILING DETAILS
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
SCALE: 1/2" = 1'-0"
6" 1' 2' 4' 8'0
SOFFIT DETAIL
SCALE: 1/2" = 1'-0"
6" 1' 2' 4' 8'0
GYPSUM CEILING DETAIL
SCALE: 1/2" = 1'-0"
6" 1' 2' 4' 8'0
ACOUSTIC CEILING DETAIL
WIRE HANGERS PER MNFR'S
RECOMMENDATION
MTL. CEILING GRID
SUSP. ACOUSTIC
CEILING TILES
SEE PLAN FOR WALL TYPE
3 5/8" MTL. STUDS @ 16" O.C.
ATTACH TO STRUCTURE
5/8" GYP. BD. (PAINTED) ON
3 5/8" MTL. STUDS @ 16" O.C.
5/8" GYP. BD. (PAINTED) ON
3 5/8" MTL. STUDS @ 16" O.C.
SUSP. ACOUSTIC
CEILING TILES
COMPRESSION STRUT
12 GUAGE BRACING WIRE W/MIN. 4
TIGHT TURNS IN 1-1/2" BOTH ENDS
OF WIRE - CONNECT TO MAIN
RUNNER (4 TOTAL AT 90°)
12 GAUGE VERTICAL HANGER WIRE AT
4'-0" EACH WAY WITH MINIMUM 3 TIGHT
TURNS IN 1-1/2" BOTH ENDS (TYP.)
2" (MAX.) FROM BRACING WIRES TO
COMPRESSION STRUT AND CROSS RUNNER
MAIN RUNNER
CROSS RUNNER
4" MAX.
20 GAUGE MIN. DECK
2 - #8 X 1/2"
SELF-TAPPING SCREWS
STEEL STRAP 3" WIDE X 12. GA (MIN)
BRACING WIRE
SCALE: NO SCALE
LATERAL BRACING ASSEMBLY
ALTERNATE STRUT LOCATION W/O NAIL.
NOTCHING PERMITTED ONLY AT RUNNER.
SLOTTED ANGLE SPACER WITH HORIZONTAL 6D
RINGSHANK NAIL (NAIL HEAD TOWARD SPAN)
MAIN OR CROSS RUNNER
ACOUSTIC PANEL
WALL CONNECTION - ANCHOR
WALL ANGLE
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
SCALE: NO SCALE
HEAD DETAIL
05/23/2019 MVP SD
A-601
DOOR SCHEDULE
WALL LOCATION
PER PLAN
PER WALL
TYPE
DOOR PER SCHEDULE
HOLLOW METAL DOOR FRAME.
REFER TO SCHEDULE AND
SPECIFICATIONS
JOINT SEALANT PER
SPECIFICATIONS (TYP.
BOTH SIDES ALL
AROUND)
SEE PLAN FOR WALL TYPE
6" LIGHT GAGE METAL STUD
BOX HEADER
2"
5 7/8"
DOOR PER SCHEDULE
HOLLOW METAL DOOR FRAME.
REFER TO SCHEDULE AND
SPECIFICATIONS
JOINT SEALANT PER
SPECIFICATIONS (TYP.
BOTH SIDES ALL
AROUND)
SEE PLAN FOR WALL TYPE
DOUBLE METAL STUD AT
DOOR JAMB
6" U
.N .O
2"
SCALE: NO SCALE
JAMB DETAIL
PER WALL
TYPE
C1 D1 F2F1
PER
SCHEDULE
3'-
"PE
R
SC
HE
DU
LE
8"
8" 8"
PER
SCHEDULE
PE
R
SC
HE
DU
LE
PE
R
SC
HE
DU
LE
2" 2"
PER
SCHEDULE
2"
7'- 2"
2"
2"
PER
SCHEDULE 2"
SCALE: 3/8" = 1'-0"
9" 1'-6" 3' 6' 12'0
FRAME TYPE SCHEDULE
SCALE: 3/8" = 1'-0"
9" 1'-6" 3' 6' 12'0
DOOR TYPE SCHEDULE
Q1
S R
P
06/13/2019 KLM NWR
FA-101
FIRE ALARM FLOOR PLAN
VEG 18.13
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax www.veritasfire.com
FIRE ENGINEERING, INC.
1E20
PATIENT
DRESSING RM
1E22-1
TREATMENT
PETSCAN
1E18
TREATMENT #01
(114, INJECTION)
1E21
PATIENT PREP
INJECTION
1E19
PATIENT PREP
INJECTION
1E24-1A
CONTROL RM
1E24
LAB
1E91
ENTRANCE
(TO UTILITY TUNNEL)1E17
RESTROOM
1E14
LAB/OFFICE
1E16
LAB/OFFICE
1E15
LAB/OFFICE
1EA
STAIR LEVEL
1EAA
ELECTRICAL
1EAB
ENTRY
(UTILITIES)
1EAC
TEL/DATA
1EAD
AUX. SYSTEMS
1E92
EXTRASTITIAL
SPACE
1E94
EXTRASTITIAL
SPACE
1E24-1B
EQUIPMENT
ROOM 1
1E24-1C
EQUIPMENT
ROOM 2
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
FIRE ALARM FLOOR PLAN
1E00A
CORRIDOR
1E00A
CORRIDOR
THE SCOPE OF THIS PROJECT IS TO
PROVIDE NEW FIRE ALARM NOTIFICATION
FOR A TENANT IMPROVEMENT IN AN
EXISTING BUILDING. SEQUENCE OF
OPERATIONS REMAINS AS INSTALLED.
EDITION OF CODES:
SCALE: NO SCALE
LEGEND
INSTALLATION NOTES:
1. ALL FIRE ALARM EQUIPMENT SHALL BE INSTALLED PER NFPA 72 AND THE
MANUFACTURER'S INSTRUCTIONS.
2. ALL INITIATING DEVICES SHALL BE FIELD LOCATED BASED UPON THE LOCATION OF
DIFFUSERS, LIGHTS, AND OTHER POTENTIAL OBSTRUCTIONS.
3. WALL MOUNTED AUDIBLE/VISUAL APPLIANCES SHALL BE MOUNTED SUCH THAT THE
ENTIRE LENS IS PLACED BETWEEN NOT LESS THAN A MIN. 80" A.F.F., & NO MORE
THAN 96" A.F.F.
4. ALL WIRING INSTALLATION SHALL CONFORM TO THE NEC.
5. ALL WIRING BELOW 7'-6" SHALL BE INSTALLED IN CONDUIT OR PROTECTED BY THE
BUILDING STRUCTURE.
6. THE VISUAL APPLIANCES SHALL CONTINUE TO OPERATE AFTER THE AUDIBLE
NOTIFICATION APPLIANCE(S) HAVE BEEN SILENCED. THE VISUAL NOTIFICATION
APPLIANCE(S) SHALL RESTORE TO NORMAL WHEN THE FIRE ALARM CONTROL PANEL
IS RESET.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RETURN ALL WIRES TO
THE PANEL FREE OF OPENS, GROUNDS, SHORTS AND/OR ANY OTHER CONDITION
THAT MAY PREVENT THE PROPER OPERATION OF THE FIRE ALARM SYSTEM.
SCALE: NO SCALE
TYPICAL DEVICE MOUNTING HEIGHTS
SCALE: NO SCALE
INSTALLATION NOTES
KEY PLAN
2015 IBC/IFC
2016 NFPA 72
2017 NFPA 70
SCOPE
FIRE ALARM PANEL
SYSTEM SUBMITTAL
KEY NOTES:
1. CONNECT NEW NOTIFICATION APPLIANCES TO
NEAREST NOTIFICATION CIRCUIT. FIELD VERIFY
CIRCUIT CAPACITY IS ADEQUATE.
SCALE: NO SCALE
KEY NOTES
SCALE: NO SCALE
LEGEND
Q1
S R
P
06/13/2019 KLM NWR
FP-101
FIRE PROTECTION FLOOR PLAN
VEG 18.13
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax www.veritasfire.com
FIRE ENGINEERING, INC.
1E20
PATIENT
DRESSING RM
1E22-1
TREATMENT
PETSCAN
1E18
TREATMENT #01
(114, INJECTION)
1E21
PATIENT PREP
INJECTION
1E19
PATIENT PREP
INJECTION
1E24-1A
CONTROL RM
1E24
LAB
1E91
ENTRANCE
(TO UTILITY TUNNEL)1E17
RESTROOM
1E14
LAB/OFFICE
1E16
LAB/OFFICE
1E15
LAB/OFFICE
1EA
STAIR LEVEL
1EAA
ELECTRICAL
1EAB
ENTRY
(UTILITIES)
1EAC
TEL/DATA
1EAD
AUX. SYSTEMS
1E92
EXTRASTITIAL
SPACE
1E94
EXTRASTITIAL
SPACE
1E24-1B
EQUIPMENT
ROOM 1
1E24-1C
EQUIPMENT
ROOM 2
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
FIRE PROTECTION FLOOR PLAN
1E00A
CORRIDOR
1E00A
CORRIDOR
KEY PLAN
3. ALL AREAS ARE LIGHT HAZARD EXCEPT MECHANICAL AND STORAGE AREAS
2. THE REMODELED SPACE IS A LIGHT HAZARD MEDICAL TREATMENT AREA.
4. THE FP CONTRACTOR MAY UTILIZE THE SMALL SMALL ROOM RULE AS ALLOWED PER
NFPA 13 8.6.3.2.4 2016 EDITION
BID NOTE:
THESE DRAWINGS ARE DIAGRAMMATIC ONLY. THE AWARDED
CONTRACTOR SHALL BE RESPONSIBLE FOR PRODUCTION OF ALL
SUBMITTAL DOCUMENTS AND OBTAINING ALL REQUIRED PERMITS AND
APPROVALS . THE AWARDED CONTRACTOR SHALL BE RESPONSIBLE FOR
ANY REQUIRED OFFSETS OF SPRINKLER PIPING AS NEEDED FOR ONSITE
COORDINATION WITH OTHER TRADES.
REMODEL LEGEND
PLAN NOTES
1. THIS WORK CONSISTS OF THE DESIGN AND REMODEL OF AN EXISTING AUTOMATIC FIRE
SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13 REQUIREMENTS. THE EXISTING
SYSTEM IS HYDRAULICALLY DESIGNED TO PROVIDE A MINIMUM 0.1 GPM PSF OVER 1500
SQFT LIGHT HAZARD OCCUPANCY.
ADDED OR RELOCATED SPRINKLER
P PLUG
5. PROVIDE TEMPORARY UPRIGHT SPRINKLERS OVER CONTROL ROOM AND CORRIDOR
WHILE CEILING IS REMOVED.
06/13/2019 DD DN
P-001
PLUMBING GENERAL NOTES,
SYMBOLS, AND ABBREVIATIONS
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
DOMESTIC HOT WATER, HOT WATER
DOMESTIC COLD WATER, COLD WATER
ORAL EVACUATION
LABORATORY VACUUM
LABORATORY AIR
MEDICAL VACUUM
MEDICAL AIR
DOMESTIC HOW WATER RETURN
STORM WATER, BELOW GRADE
STORM WATER
SANITARY SEWER, BELOW GRADE
DRAIN
DRINKING WATER SUPPLY
DRINKING WATER RETURN
NITROUS OXIDE
TEMPERED WATER RETURN
TEMPERED WATER SUPPLY
INDUSTRIAL AIR
SOIL, WASTE, OR SANITARY SEWER
SOFTEN COLD WATER
FILTERED COLD WATER
OXYGEN
NITROGEN
NATURAL GAS, BELOW GRADE
NATURAL GAS
FUEL OIL DISCHARGE
FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL VENT
VENT (SANITARY)
LIMIT OF DEMOLITION
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
ECCENTRIC REDUCER
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
UNION
RISE OR DROP IN PIPE
CAPPED OUTLET
AND EXISTING WORK
POINT OF CONNECTION BETWEEN NEW
PRESSURE GAGE
THERMOMETER
STRAINER
FLOW ELEMENT
FLOAT & THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES
PIPING ACCESSORIES
INVERTED BUCKET TRAP SET INCLUDING
PIPE UP
PIPE DOWN
CLEAN OUT
HOSE BIB
BALL VALVE
GATE VALVE WITH 3/4 " HOSE ADAPTER
CHECK VALVE
ANGLE GLOBE VALVE
BUTTERFLY VALVE
MODULATING CONTROL VALVE
TWO POSITION CONTROL VALVE
THREE-WAY MODULATING CONTROL VALVE
AUTOMATIC FLOW CONTROL VALVE
PRESSURE RELIEF VALVE
GATE VALVE
MANUAL AIR VENT
TEST PLUG (PRESSURE/TEMPERATURE)
GLOBE VALVE
PRESSURE REGULATING VALVE
THREE-WAY TWO POSITION CONTROL VALVE
AUTOMATIC AIR VENT
A/E ARCHITECT/ENGINEER
AD AREA DRAIN/ACCESS DOOR
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
AG AIR GAP
AP ACCESS PANEL
AS AUTOMATIC SPRINKLER
ASD ADJUSTABLE SPEED DRIVES
ASD AUTOMATIC SPRINKLER DRAIN
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AIR CONDITIONING ENGINEERS
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS
ASR AUTOMATIC SPRINKLER RISER
AV ACID VENT
AW ACID WASTE
BFP REDUCED PRESSURE BACKFLOW PREVENTER
BHP BREAK HORSEPOWER
BSP BLACK STEEL PIPE
BT BATHTUB
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
C CELSIUS
CA COMPRESSED AIR
CGA COMPRESSED GAS ASSOCIATION
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CO CLEANOUT
CS CLINICAL SINK
CV CONTROL VALVE
DCW DOMESTIC COLD WATER
DFU DRAINAGE FIXTURE UNITS
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DHWS DOMESTIC HOT WATER SUPPLY
DI DEIONIZED WATER
DN DOWN
DOE DEPARTMENT OF ENERGY
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWH DOMESTIC WATER HEATER
DWR DRINKING WATER RETURN
DWS DRINKING WATER SUPPLY
DWV DRAIN WASTE VENT
EL ELEVATION
EMCS ENERGY MONITORING AND CONTROL SYSTEM
EPA ENVIROMENTAL PROTECTION AGENCY
EPACT ENERGY POLICY ACT
ESC ESCUTCHEON
ESH EMERGENCY SHOWER
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
EWS EYE WASH STATION
EWS/SH EYE WASH/DRENCH SHOWER
EX EXISTING
F FAHRENHEIT
FCO FLOOR CLEANOUT
FCW FILTERED COLD WATER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT (HOSE) CONNECTION
FM FLOW METER
FOP FUEL OIL PUMP
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FS FLOOR SINK
FS FLOW SWITCH
FU FIXTURE UNITS
GAL GALLON
GCO GRADE CLEANOUTS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GRS GAS REGULATOR STATION
GT GREASE TRAP
GVTR GAS VENT THROUGH ROOF
GWH GAS FIRED WATER HEATER
H&CW HOT AND COLD WATER
HB HOSE BIBB
HD HUB DRAIN
HEX HEAT EXCHANGER
HP HORSEPOWER
HS HAND SINK
HST HOT WATER STORAGE TANK (DOMESTIC)
HWB HOT WATER BOILER
HWCP HOT WATER CIRCULATING PUMP
HWP HOT WATER PUMP
HYD HYDRANT
ID INSIDE DIAMETER
IE INVERT ELEVATION
ICW INDUSTRIAL COLD WATER
IHW INDUSTRIAL HOT WATER
INV INVERT
IPC INTERNATIONAL PLUMBING CODE
IRW IRRIGATION WATER
IW INDIRECT WASTE
IWH INSTANTANEOUS WATER HEATER
IWR INDUSTRIAL WATER RETURN
IWS INDUSTRIAL WATER SUPPLY
KW KILOWATT
KWH KILOWATT-HOUR
L/S LITER PER SECOND
LA LABORATORY AIR
LAV LAVATORY
LBS/HR POUNDS PER HOUR
LCW LABORATORY COLD WATER
LHW LABORATORY HOT WATER
LNG LIQUID NATURAL GAS
LOX LIQUID OXYGEN
LV LABORATORY VACUUM
LW LOW WATER
M METER
MA MEDICAL AIR
MAV MANUAL AIR VENT
MBH 1000 BTUH
MED MEDICAL
MER MECHANICAL EQUIPMENT ROOM
MH MANHOLE
MOU MEMORANDUM OF UNDERSTANDING
MSB MOP SERVICE BASIN
MV MEDICAL VACUUM
N2 NITROGEN
N20 NITROUS OXIDE
NC NORMALLY CLOSED
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NOM NOMINAL
NPW NON-POTABLE WATER
NTS NOT TO SCALE
O2 OXYGEN
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OR OPERATING ROOM
OVFL OVERFLOW
PA PASCAL
PD PRESSURE DROP OR DIFFERENCE
PDI PLUMBING AND DRAINAGE INSTITUTE
PG PRESSURE GAGE
PP PLUMBING PUMP
PPM PARTS PER MILLION
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH ATMOSPHERE
PSIG POUNDS PER SQUARE INCH GAGE
PTRV PRESSURE TEMPERATURE RELIEF VALVE
PW POTABLE WATER
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
RL ROOF LEADER
RP RECIRCULATION PUMP
RO REVERSE OSMOSIS WATER
RWL RAIN WATER LEADER
SAN SANITARY SEWER
SMACNA SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION
SCFM STANDARD CUBIC FOOT/MINUTE
SCW SOFTENED COLD WATER
SDMH STORM DRAIN MANHOLE
SMH SANITARY MANHOLE
SP SUMP PUMP
SPR SPRINKLER LINE
SQFT/SF SQUARE FEET
SS STAINLESS STEEL
ST STORAGE TANK
SW STORM WATER
TCV TEMPERATURE CONTROL VALVE
TD TEMPERATURE DIFFERENCE
TD TRENCH DRAIN
TDH TOTAL DYNAMIC HEAD TEMP TEMPERATURE
TMV THERMOSTATIC MIXING VALVE
TP TRAP PRIMER
TSTAT THERMOSTAT
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
TYP TYPICAL
V VENT
VAC VACUUM
VB VACUUM BREAKER
VCO VACUUM CLEANER OUTLET
VP VACUUM PUMP
VS VENT STACK
VSD VARIABLE SPEED DRIVE
VTR VENT THROUGH ROOF
W WASTE
WC WATER CLOSET
WCO WALL CLEANOUT
WG WATER GAGE
WH WALL HYDRANT
WH WATER HEATER
WHA WATER HAMMER ARRESTER
WL WATER LINE
WM WATER METER
WPD WATER PRESSURE DROP
WS WASTE STACK
WSFU WATER SUPPLY FIXTURE UNITS
YCO YARD CLEANOUT
YH YARD HYDRANT
PLUMBING PIPING SYMBOLS GENERAL PLUMBING SYMBOLS PLUMBING VALVE SYMBOLS
PLUMBING ABBREVIATIONS
A
N S
A N
S A
N S
A N
S A
N S
A N
S A
N S
A N
S
A
N
S
A
N
S
A
N
S
A
N
S A
N
SAN SAN SAN SAN SAN
FD-1
(E) 1" Ø
(E) 2" Ø (E) 2" Ø
(E) 4" Ø
(E) 2" Ø
2" Ø V
3" Ø
SIEMENS
PROVIDED
CWC CABINET
SIEMENS
PROVIDED PET
SCANNER
T
Q1 S
R
34A3433A31A
PROVIDE TYPE E FLOOR DRAIN. REFER TO SPECIFICATIONS SECTION 23 13 00 FOR
REQUIREMENTS. ROUTE DRAINS FROM PET SCANNER AND FCU-1 FAN COIL UNIT
TO FLOOR DRAIN. COORDINATE LOCATION OF FLOOR DRAIN WITH NEW SIEMENS
EQUIPMENT. REFER TO MP101 FOR PIPING SCHEMATIC.
REMOVE AND REPLACE EXISTING SINK WITH COUNTER MOUNTED HAND SINK,
P-418. PROVIDE NEW PIPE CONNECTIONS TO EXISTING PIPES.
KEY NOTES:
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16'0
PLUMBING FLOOR PLAN
06/13/2019 DD DN
P-101
PLUMBING FLOOR PLAN
VEG 18.13
660-CSI-108
500 FOOTHILL DRIVE SALT LAKE CITY, UT 84148
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Issued: Date:
750 W HAMPDEN AVE
SUITE #300
ENGLEWOOD CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
CONSULTANTS: ARCHITECT/ENGINEERS: STAMP: CONSTRUCTION DOCUMENTS
(Contract Deliverable CD3-100%)
PET Scanner Site Prep
1E20
PATIENT
DRESSING RM
1E18
PATIENT PREP
INJECTION
1E21
PATIENT PREP
INJECTION
1E19
PATIENT PREP
INJECTION
1E24
CONTROL RM
1E24
LAB
1E17
RESTROOM
1E14
LAB/OFF…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .