M-3 Submarine Location.pdf
PDF 2 MB Posted
- Attached to
- Resolving Plumbing Issues Federal contract opportunity
- Solicitation number
- 36C25620R0125
About this file
The documents include a government file and a related federal contract opportunity. The government file contains architectural drawings for a proposed M-3 Submarine Location project. The drawings show floor plans, notes and details for construction of the facility.
The related federal contract opportunity is a solicitation from the Department of Veterans Affairs seeking design and construction services to resolve plumbing issues at sites within the Southeast Louisiana Veteran Healthcare System. Contractors are required to provide all labor, supervision, equipment, materials and resources necessary to design and build new and revised site utilities for domestic water pumps and address plumbing problems occurring at facilities in Southeast Louisiana.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| M-5 Backflow Valve Addition Requirement.pdf | ||
| M-2 Submarine Specifications.pdf | ||
| Section 01 35 26 - Safety Requirements.pdf | ||
| Section 01 32 16.15 - Schedules.pdf | ||
| Section 01 00 00 - General Requirements.pdf | ||
| M-1 SLVHCS Layout.pdf | ||
| VA Master Specs Table of Contents.pdf | ||
| EXHIBIT A CONTRACTOR EVALUATION FORM CONSTRUCTION SAFETY.pdf | ||
| M-6 Cross Pipe.pdf | ||
| M-4 Current Backflows.pdf | ||
| General Decision LA 20200041 01-24-2020 Building.pdf | ||
| 36C25620R0125_1 - Final.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T H
R E
E I N
C H
E S
O
N E
F O
O
O N
E I
N C
H
F O
R T
Y F
E E
T
N
.2
6 5 4
RFI:00486.1 - Electrical shaft shift east and widening.
RFI 02336 Interface with Exterior
Wall
2 1
F6
7AI404
A A5
HK
1N142
TOILET
1N143
FD FD
TOILET
1N144
7M15
DOMESTIC
PUMP
ACCESS
1N145
ELECT.
SHAFT
SHN-2
S20A7
S20A7
MEZZANINE ABOVE
A
CORR
1N-C02
FEC
0AI517
Prebid RFI
1N141
1N142 1N143
LOBBY
1N144 1N145
1N145.1
SECURE
STORAGE
F5
7AI403
1N102
UTILITY
F6 ACCESS
1N102
CART
WASH
1N109
EWP-08-0254: Add Equipment/Specialties
1N109.1
RFI 1096
1N140
F3
7AI418
DN
F2
7AI412
1N127A.1
CR
1N127A
RFI 02215:
DIMENSIONS
BASED ON
07 PARTITIONS
Y2
VEST
1N-CO2
C5
RFI 06614:
Storefront Deleted
RMW/
SHARPS
HOLDING
WASH
Z, not S Partition
RFI 03321:
Ladder
RFI 1356
1N-STN3
UP
RFI-05624: P24 partition on top of CMU in lieu of D7 designation
RFI 02336 Interface with
Exterior Wall
F4
1N-C02A
1N111.1
1N111 AREA FD
1N109A
RFI 02369: Wall
ELEC
1N100
Rack
S_8C7 shows remote selector panel location.
ELEVATOR
SHAFT
RFI-03051:Gyp board not
D6
B6 7AI402
FUEL
MED
1N113.1
LINEN
CHUTE
Furrout with CMU
SHN103
EWC required on backside
STAIR
STN-3
U22
RFI-03476: Elevator UP Door Jam revised detail
B 07
Y4
ACCESS LADDER SEE
EWP_06 FOR SCHED
AND SPECIFICATIONS
OIL
TRANSFER
PUMP
ROOM
1N152
7M05
UP
GAS
1N104
FLAM
STORAGE
1N106
1N104
RFI 352.
Added
CMU
partition in corner.
COLLECTION
1N113
AL 1N115.3
7M21
SHN106
7M20
SHN-1
PRE-BID RFI
7AS718
FEW
07 B
7M13
GUARDRAIL SEE
EWP_06 FOR SCHED
S-3
RFI 01469
See curb modification.
RECYCLE
HOLD
1N115
7M19 EWP-08-2730: DOOR
HM 3'x7' 90 MIN
RATED W/ HW HC-5C
RFI 1705: Curb &
Y6
C
TRASH COLLECTOR
AND COMPACTOR
AND SPECIFICATIONS 134
S-2
S-1
SOILED
DOCKS
1N108
E-N1-108
1N110.2
1N117
HAZ
WASTE
HOLDING
1N117
WORK
STATION
1N123A
CUBICLES
1N123B
FD
F2
7AI411
1N127 waterproofing
C
RFI-02062.1: CMU partition shifted 8" to east.
07 OPEN DUMPSTER OR
Y8 FUTURE COMPACTOR
C-4
CLEAN
DOCKS
1N110
RECEIVING
ISSUE
RFI 01013
Changes wall to S_8
WAREHOUSE
WELDING
1N129B
1N129.2
AC
MASON 07
SHOP 9
1N131
RFI-02461: Should be 135- 11 13 00
- Manual Dock Leveler and Bumpers
E-N1-110.1
1N119.1
1N119
1N119.2
1N128
FD
SHOP
1N129
19B
A5
FOREMAN
1N129C
7AI401
B5 7AI401
1N131
1N133.1
RFI:00613 - Dock should be consistently sloped from the wall to the dock edge. Floor
Drains should be sloped with the finished concrete.
D
Y9
C-3
C-2
E-N1-110.2
12D
7AI402
STOREKEEP
1N121
1N121
1N123
C5
7AI401
1N146
1N129.1
1N129.3
Z_R7A
D
GUARDRAIL SEE
BOLLARD
POWERED DOCK LIFT
C-1
STOREKEEP
1N123
RFI 02215: 10' E/W
1N-C03
1N120
RFI 02338 -
CMU does not Exist
EJ
Y19
C4
L
K
RFI 02336 Interface with Exterior Wall
Y11
EWP_06 FOR SCHED
AND SPECIFICATIONS
RAMP
7M06
AND RECESSED SLAB FD
18A
E-N1-C03
1N118.2
TELECOM
1N118A
1N118.1
SECURITY
1N118
CIM
COMMUNICATIONS
STOR
1N120
07 07
07 XA
YF
YE
F3
7AI402
07 H
YG
RFI-07583: Break Metal Closure at wall/curb interface J
E
Y13 F5
1N116.3
GROUNDS
FOREMAN
1N116A
D5 1N116.2
PB
E-N1-116
STAIR
E-N1-STN2 STN-2
RFI 04676.2: Added
Drywall/Furrout Not Required
E
RFI-03845: Fire Extinguisher E-N1-114.2
E-N1-114.1
E-N1-112
SECURITY
1N112
GROUNDS
OUTSIDE
STORAGE
1N114
WORKSHOP
1N116
Y17
D6
B6
YB.9
F4
YC
YD
RFI-03106: Infill missing partition with type A_6 types and locations
YA
Y15
YB
RFI-03152: 6" CMU furring acceptable underneath stair
LEVEL 1 AREA N1 PLAN
SCALE: 1/8" = 1'-0"
RFI-07135: SCONC SC to extend to edge of slab (outside coiling door)
F
CONSULTANTS:
ARCHITECT/ENGINEERS:
DRAWING TITLE
PROJECT TITLE PROJECT NUMBER
F
BUILDING NUMBER
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
BLDG 7 FIRST FLOOR PLAN - AREA N1 LEVEL 1
(EL. 100'-0")
APPROVED: PROJECT DIRECTOR
SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
LOCATION
NEW ORLEANS, LOUISIANA
629-HS2-401 7
DOCUMENT SET PACKAGE
WP_08
DRAWING NUMBER
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
11 BULL 015A - PRE-AWARD 7/26/2013 TATA & HOWARD / TANK CONSULTANT ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DATE
February 29, 2012
CHECKED
DV
DRAWN
JEN 7AI101-N1
Department of Veterans Affairs
REVISIONS:
VA FORM 08-6231
DATE
6 5
4 3 2 1
RFI-05341.1: Firestopping at Exterior Termination Clarification
RFI-03153: Shaft size clarification. Partition shifted east
RFI-05188:
Revised Ladder and landing
RFI 02075: Wall type Z28D7
O N
E S
IX
T
E E
N T
H I N
C H
O
N E
F O
E
E
IG
H T
I N
C H
O
N E
F O
E
Q U
A R
T E
R I N
C H
O
N E
F O
E
H A
L F
I N
C H
O
N E
F O
R E
E Q
U A
R T
E R
S I N
C H
O
N E
F O
E
A N
D O
N E
H A
L F
I N
C H
E S
O
N E
F O
.3
.4
.5
-C
.3
.1
.4
I1
I1
GENERAL FLOOR PLAN NOTES
1. REFER TO SHEET 0AI002 FOR PARTITION SCHEDULE AND GENERAL
PARTITION TYPE NOTES.
2. REFER TO AI400 SERIES FOR ENLARGED FLOOR PLAN VIEWS INCLUDING
MEDICAL EQUIPMENT NOT SHOWN IN AI100 SERIES PLANS.
3. REFER TO LIFESAFETY DRAWINGS (LS SERIES) FOR CAMPUS-WIDE
SCOPE OF RATED WALL CONSTRUCTION, SMOKE PARTITIONS, SUITE
DESIGNATIONS AND EXIT DISCHARGE INFORMATION.
4. PARTITION TYPES AS NOTED BY THE SYMBOL CONTINUE BETWEEN
ROOM/SPACE CORNERS OR ANY INTERSECTING PARTITION.
5. DIFFERING PARTITION TYPES SHALL ALIGN SO THAT WALL PLANES
CONTINUE UNBROKEN WITHIN/ACROSS ROOMS AND/OR SPACES.
6. UNLESS OTHERWISE NOTED, DIMENSIONS ARE TO FINISH FACE.
7. REFER TO AI600 SERIES DRAWINGS FOR DOOR & RELITE SCHEDULES.
8. DISTANCE FROM HINGE SIDE OF DOOR TO INTERSECTING STUD WALL
SHALL BE 4" UNLESS NOTED OR DETAILED OTHERWISE (MEASURED
FROM OUTSIDE OF FRAME).
9. CONTRACTOR SHALL VERIFY ALL DIMENSIONS NOTED AS "CLEAR" OR
"MIN". DIMENSIONS NOTED AS "HOLD" ARE CRITICAL TO COORDINATE
OTHER WORK (E.G. CEILING GRIDS, LIGHTING, FINISHES).
10. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO INITIATING
CONSTRUCTION AND REPORT DISCREPENCIES TO ARCHITECT PRIOR
TO COMMENCING WORK.
11. CONTRACTOR SHALL PROVIDE ALL BLOCKING REQUIRED TO ANCHOR
ALL WALL AND CLG MOUNTED ITEMS, INCLUDING BUT NOT LIMITED TO
TOILET ROOM ACCESSORIES, MILLWORK, CASEWORK, HANDRAILS,
DOOR STOPS ETC...
12. FIRE STOPPING SYSTEMS - REFER TO SPEC SECTION 07 84 00 FOR INFO
REGARDING PENETRATIONS OF ALL RATED ASSEMBLIES (BOTH SINGLE
AND DOUBLE MEMBRANE PENETRATIONS) INCLUDING BUT NOT LIMITED
TO PENETRATIONS FOR DUCTWORK, CONDUIT, PIPING AND SUPPORT
FOR WALL MOUNTED EQUIPMENT, CABINETS AND COUNTERTOPS.
13. UP-SWING GRAB BAR IN-WALL SUPPORT - SEE DTLS C3 AND A3 SHEET
0AI506 FOR TUBE STEEL BACKING AT ALL UP-SWING GRAB BARS.
14. SEE DETAIL A3/0AI516 FOR COLUMN BASE WATERPROOFING AT
EXPOSED COLUMNS IN SERVICE BAYS & MECHANICAL ROOMS.
15. SHIELDING REQUIREMENTS - VERIFY ALL SHIELDING REQUIREMENTS
WITH FINAL EQUIPMENT SELECTIONS AND A VA APPROVED
REGISTERED PHYSICIST PRIOR TO COMMENCING WORK IN SHIELDED-
ROOM AREAS.
16. HOUSEKEEPING AND COPY ROOMS - ALL PARTITIONS TO BE FULL
HEIGHT TO UNDERSIDE OF DECK/INTERSTITIAL ABOVE. SEE PARTITION
TYPE NOTES SHEET 0AI002.
17. AT PARTIAL HEIGHT CMU PARTITIONS WITH GYPSUM WALLBOARD
ABOVE TO STRUCTURE ALIGN FACE OF GWB AND CMU AT SIDE OF
MAJOR CORRIDORS. ALL OTHER LOCATIONS CENTER GWB ON CMU
WALL UNLESS NOTED OTHERWISE
1XX FLOOR PLAN SHEET NOTES
FLOOR PLAN SHEET NOTE SERIES BEGINS WITH NOTE 100
NOT ALL SHEET NOTES APPEAR ON EVERY SHEET
100. SLAB OPENING - REF STRUCTURAL DWGS
101. ALIGN PARTITIONS
102. LINE OF CURTAIN WALL SILL - REF EXTERIOR SERIES DWGS.
103. LINE OF HOISTWAY BELOW
104. AIR HANDLER UNIT - REF MECHANICAL DWGS
105. STEEL BRACING - REF STRUCTURAL DWGS
106. CONCRETE HOUSEKEEPING PAD - REF STRUCTURAL DWGS
107. ACCORDIAN FIRE DOOR - REF DOOR SCHEDULE
108. NOT USED
109. 08 31 13 FLOOR VAULT DOOR - 36" X 36". REF DTL E1/0AI516
110. ROOF/OVERFLOW DRAIN LEADER - REF PLUMBING DWGS
111. ELECTRICAL PANEL - REF ELECTRICAL DWGS
112. MEDICAL GAS ZONE VALVE BOX/MEDICAL GAS ALARM PANEL - REF
MED GAS DWGS
113. SLOPE FLOORING IN SHOWER/TOILET ROOM TO FLOOR DRAIN
114. SLAB RECESS FOR HIGH DENSITY SHELVING TRACK. VFY RECESS
DIMENSION W/ SHELVING MANUFACTUER.
115. 14 91 34 TRASH/LINEN CHUTE & STATION: SEE DETAILS E6/0AI507
116. 14 91 34 TRASH/LINEN CHUTE: NO LOADING STATION
117. 14 91 34 TRASH/LINEN CHUTE: PROVIDE SLEEVES @ LEVEL 01 FLOOR
SLAB PENETRATION - SEE DETAILS E6/0AI507
118. 08 31 13 3-HOUR FIRE RATED ACCESS PANEL - 24" X 48".
119. ELECTRICAL RISERS - SEE PLAN DETS ON F5/0AI512 - REF ELEC DWGS
120. CONCRETE ENCASED ELECTRICAL FEEDERS ABOVE - REF
STRUCTURAL & ELEC DWGS
121. 09 27 02 GLASS FIBER REINFORCED GYPSUM COLUMN COVER -
36" O.D. UON.
122. BOLD DASHED LINE INDICATES ROUTE OF STRUCTURAL EXPANSION
JOINT - REF STRUCTURAL DWGS. REFERENCE FLOOR PLAN LEGEND
FOR INTERIOR EXPANSION JOINT COVER ASSEMBLY INFORMATION.
123. 10 11 00 MARKER BOARD REF INTERIOR ELEV SHEET NOTE 207.
124. 10 11 00 TACK BOARD REF INTERIOR ELEV SHEET NOTE 208.
125. 10 28 00 FOLD-DOWN BENCH
126. 10 28 00 FOLD-DOWN SHOWER SEAT
127. SLAB RECESS FOR WALK-OFF GRILLE. VFY RECESS DIMENSION W/
GRILLE MANUFACTURER. SEE FLOOR FINISH PLANS FOR EXTENTS.
128. PLUMBING ROUGH-IN FOR FUTURE SINK - REF PLUMBING DWGS.
129. BENT PLATE W/ TRAFFIC COATING WRAP @ WALL BASE - REF
130. B3/0AI516
131. LINE OF 2-HR RATED SHAFT ABOVE. REF DETAILS E1 & E3 SHT 0AI507
132. 05 05 00 ACCESS LADDER
133. 10 33 13 WIRE MESH PARTITION
134. 05 52 13 PIPE AND TUBE RAILING
135. 11 13 00 MANUAL DOCK LEVELER AND BUMPERS
136. 13 44 00 MODULAR MEZZANINES INCL. STAIRS & WIRE MESH PTNS.
137. 05 50 00 METAL GRATE CATWALK
138. WALL MOUNTED HAND SINK - REF PLUMBING DWGS
RECESSED EMERGENCY SHOWER AND EXPOSED STAINLESS STEEL
139. SHOWER HEAD - REF PLUMBING DWGS
140. 08 39 19 FLOOD BARRIERS: FLOOD PLANK SYSTEM - REF D5/0AI511
141. CONC. WALLS @ L 01 ELEV SHAFTS - REF STRUCT DWGS & DTL
142. D2/0AI507
143. BENT PLATE W/ PEDESTRIAN TRAFFIC COATING WRAP - REF C3/0AI516
144. PLENUM SYSTEM - SEE EXTERIOR DRAWINGS
145. CENTER PARTITION ON GRIDLINE
146. CENTER PARTITION ON MULLION
147. 10 21 13 TOILET PARTITIONS
148. TOP OF SHAFT LID ASSEMBLY - REF DETAIL B4/0AI507
149. CONC CURB W/ PEDESTRIAN TRAFFIC COATING WRAP - REF D3/0AI516
LIGHTING INVERTER CABINET - REF ELEC DWGS
ELEVATOR SUMP PUMP CONTROL PANEL - REF PLUMB DWGS
150. ALIGN GYPSUM WALL ABOVE WITH THIS FACE OF CMU
KEY PLAN
PLAN
NORTH
09 Q B1 B2 D2 D1 A1
D3
E3 E2 E1 A2 C1 C2
F3 A3 F2 F1
A4 G2 G1
04 K A5
J1 J2
R1 00 A6
R2 M1 M2 L
R3 M3
R4 A7
06 N1 N2
08 P
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
Submarine
File details come from the government source that posted it. Updated .