36C25218B0984-0001003.pdf

PDF 4 MB Posted

Attached to
Demolish Quonset Huts 550-18-111 Federal contract opportunity
Solicitation number
36C25218B0984
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12

About this file

36C25218B0984 0001 Asbestos Inspection-Lead-Based Paint Report-2013.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Demolish Quonset Huts 550-18-111, newest first.
File Type Posted
36C25218C0213-001.pdf PDF
36C25218C0213-000.docx DOCX document
36C25218B0984-0001000.docx DOCX document
36C25218B0984-0001002.pdf PDF
36C25218B0984-0001001.pdf PDF
36C25218B0984-003.pdf PDF
36C25218B0984-002.docx DOCX document
36C25218B0984-004.pdf PDF
36C25218B0984-001.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS NESHAP INSPECTION

LEAD-BASED PAINT SAMPLING REPORT

for the

DEPARTMENT OF VETERANS AFFAIRS

VA ILLIANA HEALTH CARE SYSTEM

DANVILLE CAMPUS

DANVILLE, IL

VA PROJECT #

550-13-114

DEMOLISH QUARTERS & QUONSET HUTS

20 BUILDINGS

INSPECTION DATE:

AUGUST 2, 2013

CONDUCTED BY:

USFIN DEVELOPMENT, LLC

7920 N. WOODBRIDGE RD.

MONCLOVA, OH 43542

419-382-9574

ASBESTOS NESHAP & LEAD-BASED PAINT INSPECTION REPORT

DANVILLE VAMC – DANVILLE, IL

DEMOLISH QUARTERS & QUONSET HUTS - 20 BUILDINGS

AUGUST 2013

TABLE OF CONTENTS

1.0 ASBESTOS INSPECTION SUMMARY

2.0 ASBESTOS INSPECTION SAMPLING PROTOCOL & GLOSSARY

3.0 SUMMARY OF ASBESTOS MATERIALS

4.0 SUMMARY TABLE OF ASBESTOS MATERIALS BY BUILDING

5.0 SUMMARY OF NON-ASBESTOS CONTAINING MATERIALS

6.0 LEAD-BASED PAINT INSPECTION SUMMARY

7.0 LEAD-BASED PAINT SAMPLING DATA AND RESULTS

8.0 LABORATORY ANALYSIS RESULTS APPENDICES

Appendix A - Asbestos Bulk Sampling Log Form and Results

Appendix B – Lead Bulk Sampling Log Form and Results

Appendix C – Laboratory Reports (Asbestos & Lead)

Appendix D – Inspector and Laboratory Certifications

1.0 ASBESTOS INSPECTION SUMMARY

On August 2, 2013, Wes Green, Brett Brumbaugh and Samuel Ansara performed an inspection and sampling to comply with the US Environmental Protection Agency (EPA) regulation National Emission Standards for Hazardous Air Pollutants (NESHAP). The purpose of this inspection was identify and quantify the potential regulated asbestos containing materials (RACM) and non-RACM materials located in Quarters 31, 32, 33, 34, 37, 38, 41, Quarter Garages 75, 78, 81, 82, 83, and Quonset Huts 110, 111, 112, 113, 114, 116, 117, and 124 on the Danville VA campus in Danville, IL for the Department of Veterans Affairs as part of the planned demolition of the structures.

As a result of this inspection, and previous asbestos inspections, asbestos was identified in the following structures:

Quarters 31

Quarters 32

Quarters 33

Quarters 34

Quarters 37

Quarters 38

Quarters 41

Quonset Hut 124

The asbestos materials in these 8 structures must be removed by a State Licensed asbestos contractor prior to the demolition of the structures in accordance with USEPA NESHAP and State of Illinois asbestos regulations.

The remaining 12 structures were determined to be asbestos free as a result of the inspections and subsequent laboratory analyses of suspect asbestos containing materials.

Bulk sampling of suspected ACM was based upon the appearance, texture, and location of the material. All bulk samples were analyzed utilizing current EPA methods for PLM (Polarized Light Microscopy) by EMSL laboratory in Ann Arbor, MI. EMSL laboratory is accredited by the NIST, NVLAP program (National Institute of Standards and Technology, National Voluntary Laboratory Accreditation Program) and also an American Industrial Hygiene Association (AIHA) accredited laboratory.

The bulk sampling of the asbestos materials was conducted by Wes Green who is accredited by the State of Illinois as an Asbestos Inspector and Management Planner #100-06951. Also assisting with the surveys and report preparation were Brett Brumbaugh who is an accredited asbestos inspector in 7 states and has conducted asbestos inspections for 26 years; and Sam Ansara was also assisting on the inspections and has also been conducting asbestos inspections for 25 years.

Prior to this inspection, USFin was provided copies of the previous asbestos survey conducted by Cape Environmental in 1995 that included extensive sampling. The purpose of this inspection was to verify the adequacy of the previous sampling and to re-quantify all asbestos containing materials in the buildings. Also, the 1995 survey determined that numerous suspect asbestos containing materials that were analyzed had no asbestos detected. A negative sample analysis is the only definitive method to determine if a material can be considered “non-asbestos” in accordance with OSHA and EPA regulations.

All physically accessible areas in the buildings were visually inspected and any material suspected to contain asbestos was sampled during the inspection. Bulk sampling of suspected ACM was based upon the appearance, texture, and location of the material. Random samples were taken from each homogeneous area of materials. Every effort was made to collect bulk samples from already damaged areas. When samples were taken, efforts were made to reduce the potential for exposure to the evaluator and the building occupants. Where feasible, the sampling area was wetted with amended water to reduce the release of fibers when the sample was taken.

Inspectors:

Wes Green Certified Asbestos Inspector/Management Planner Illinois License Number: #100-06951

Brett Brumbaugh US EPA Trained Asbestos Inspector/Management Planner/Project Designer

Samuel Ansara US EPA Trained Asbestos Inspector/Management Planner/Project Designer

2.0 ASBESTOS INSPECTION SAMPLING PROTOCOL & GLOSSARY

SAMPLING PROTOCOL

The bulk samples were collected from locations that were selected to be representative of the building materials. Sampling was accomplished using the simplified sampling scheme referenced in the AHERA regulations and found in the “Pink Book”. Locations of individual samples are referenced on this report.

The samples were either collected with a coring tool designed for asbestos sampling or placed into a plastic bag for laboratory analysis. The samples were analyzed via polarized light microscopy with dispersion staining, using the “Interim method for the Determination of Asbestos in Bulk Insulation Samples” found in Appendix A to Subpart F in 40 CFR Part 763.

The regulations require specific numbers of samples be obtained per homogeneous area. For example when sampling for joint compound or asbestos in hard plaster (sprayed-on or troweled-on surfacing materials) samples are to be taken based on the following increments: 0 to 1000 square feet of material, 3 samples are necessary. From 1001 to 5000 square feet, 5 samples are necessary, over 5000 square feet 7 samples are required. If during analysis any samples are found to contain asbestos, the entire homogeneous area is delineated as asbestos containing material. In the case of pipe insulation or other types of manufactured materials, the regulations require only enough samples to ascertain whether asbestos is present. In this case, the minimum amount of samples to collect and analyze is usually three.

The sampling performed in this inspection followed these sampling guidelines.

ASBESTOS GLOSSARY OF TERMS

Friable asbestos material: means any material containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763 section 1, Polarized Light Microscopy, that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.

Category I Non-friable Asbestos Containing Material (ACM) means asbestos containing packings, gaskets, resilient floor coverings, and asphalt roofing products containing more that 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763, Section 1, Polarized Light Microscopy.

Category II Non-friable ACM means any material, excluding Category I non-friable ACM, containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763, section 1, Polarized Light Microscopy that when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

Regulated Asbestos Containing Material (RACM): means (a) Friable asbestos material, (b) Category I non-friable ACM that has become friable, (c) category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or (d) Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material expected in the course of demolition or renovation operations regulated by this subpart.

3.0 SUMMARY OF ASBESTOS MATERIALS

Asbestos Containing Materials

Building A B C D E

Quarters 31 X X

Quarters 32 X

Quarters 33 X X

Quarters 34 X X

Quarters 37 X X

Quarters 38 X X

Quarters 41 X

Quarters Garage 75

Quarters Garage 78

Quarters Garage 81

Quarters Garage 82

Quarters Garage 83

Quonset Hut 110

Quonset Hut 111

Quonset Hut 112

Quonset Hut 113

Quonset Hut 114

Quonset Hut 116

Quonset Hut 117

Quonset Hut 124 X

Legend: A = Pipe Insulation B = Floor Tile & Mastic C = Asbestos Paper D = Sink Mastic E = Transite Panels

4.0 SUMMARY TABLE OF ASBESTOS MATERIALS BY BUILDING

Quarters Building 31

Asbestos Material Locations Quantity NESHAP Category

Pipe Insulation Basement Laundry, Hallway, Workshop, Storage Rooms, Service Room, and Bathroom

380 lf and 60 fittings RACM

Paper behind radiators

Dining Room and Living Room on 1st Floor

100 LF of 6” paper RACM

Quarters Building 32

Category

Pipe Insulation In walls from boiler room and laundry room to attic; behind kitchen wall by closet; attic

120 lf and 12 fittings RACM

Quarters Building 33

Category

Pipe Insulation Basement Boiler Room and 7 storage rooms

320 lf and 50 fittings RACM

9” vinyl floor tile and mastic

Toilet off of living room 70 sf Cat. 1 Non-Friable

Quarters Building 34

Category

Pipe Insulation Basement Boiler Room and 5 storage rooms

380 lf and 55 fittings RACM

Sink mastic Kitchen 1 sink Cat. 1 Non-Friable

Quarters Building 37

Category

Pipe Insulation Basement Boiler Room and 4 storage rooms

320 lf and 40 fittings RACM

9” vinyl floor tile and mastic under new tile

Pantry off Kitchen 55 sf Cat. 1 Non-Friable

Quarters Building 38

Category

Pipe Insulation Basement Boiler Room and 3 storage rooms

360 lf and 45 fittings RACM

9” vinyl floor tile and mastic

Stairs and landing to basement and first floor closet; 2nd floor bathroom

55 sf Cat. 1 Non-Friable

Quarters Building 41

Category

9” & 12” vinyl floor tile and mastic

Kitchens and Pantry’s (A&B);

Entry and Stairs of A

960 sf Cat. 1 Non-Friable

9” & 12” vinyl floor tile and mastic under linoleum

1st Floor Restrooms of A&B 80 sf Cat. 1 Non-Friable

Quonset Hut Building 124

Category

Transite cement sheets

South storage area (east wall) 80 sf Cat. 2 Non-Friable

5.0 SUMMARY OF NON-ASBESTOS CONTAINING MATERIALS

The materials that have been determined to be non-asbestos through current or previous laboratory analyses, and/or EPA exemption include:

Hard wall and ceiling plaster (base and finish coats)

Drywall systems (gypsum board and joint compound)

Ceiling Tiles (12”, 2x2, and 2x4)

Vinyl cove base and mastic

Fiberglass pipe insulation

Cellulose spray-in attic insulation

Black foam rubber pipe insulation

Fiberglass duct insulation with foil jacketing

Window glazing and caulk

Styrofoam exterior coating

Cellulose board

Stucco exterior wall coatings

Mudded fittings and calcium-silicate pipe insulation (116 & 117)

Fireplace cement

6.0 LEAD-BASED PAINT INSPECTION SUMMARY

The sampling of the paint chips was conducted by Wes Green who is accredited by the State of Illinois as a Lead Inspector. Also assisting with the sampling and report preparation were Brett Brumbaugh who is an EPA trained Lead Inspector and Risk Assessor and has conducted lead testing for 22 years.

Lead paint testing was conducted in the structures by collecting paint chips of representative chips of paint. Lead paint is not regulated as asbestos in such that it does not need removal prior to demolition. However, the OSHA Lead in Construction Standard (1926.62), mandates that any contractors who will disturb lead-based paint are required to conduct an initial exposure assessment of their workers to determine whether the action level for airborne Lead exposure to workers of 30 ug/m3 will be exceeded during the project (unless the contractor has historical data or a negative exposure assessment from a similar project.)

The OSHA Lead Exposure in Construction Standard 29 CFR 1926.62 makes no exceptions for the percentages of lead in paint. The actual wording in the OSHA Standard is “if lead is present in your workplace in any quantity...”, then the Standard is in effect. Therefore, the demolition contractor must abide by the OSHA regulation during demolition regarding employee exposure.

In addition, it is recommended that the demolition contractor cleanup all loose paint chips on the soil following the demolition of the structures and prior to backfilling the excavated holes. This will prevent the lead paint chips from remaining in the soil for potential future exposure to the campus occupants.

As a result of the paint chip testing, it is determined that all structures have painted surfaces that contain lead in some percentage and therefore the contractor must abide by the OSHA regulations during the demolition activities. The summary of the lead chip testing is provided in Appendix B.

APPENDIX A

ASBESTOS BULK SAMPLING LOG

ASBESTOS BULK SAMPLING INFORMATION

Facility: VAMC Danville – Danville, IL Project: Demolish Quarters & Quonsets Project Number: 550-13-114 Inspection Date: August 2, 2013 Inspector: Wes Green, IL License #100-06951 Analysis Date: August 12-14, 2013 Laboratory: EMSL Analytical, Inc. – Indianapolis, IN Accreditation: NVLAP Asbestos Bulk Accredited Laboratory #200188-0

SAMPLE

NUMBER

BUILDING SAMPLE LOCATION MATERIAL LABORATORY

ANALYSIS RESULT

1 116 S. side window Window glazing No Asbestos Detected

2 116 N. side window “” No Asbestos Detected

3 116 E. side heater Mud fitting on cal-sil pipe No Asbestos Detected

4 116 W. side heater “” No Asbestos Detected

5 116 S. side Cellulose ceiling board No Asbestos Detected

6 116 S. side exterior Spray-on Styrofoam insul. No Asbestos Detected

7 116 S. side interior “” No Asbestos Detected

8 117 E. side interior Mud fitting on cal-sil pipe No Asbestos Detected

9 117 S. side interior Cellulose ceiling board No Asbestos Detected

10 117 N. side exterior Spray-on Styrofoam insul. No Asbestos Detected

11 117 S. side window Window glazing No Asbestos Detected

12 117 N. side window “” No Asbestos Detected

13 110 Above 2x4 ceiling tile Cellulose ceiling board No Asbestos Detected

14 110 W. side window Window glazing No Asbestos Detected

15 111 S. side window “” No Asbestos Detected

16 111 Smoking room Drywall system No Asbestos Detected

17 112 S. side window Window caulk No Asbestos Detected

18 112 “” Window glazing No Asbestos Detected

19 112 S. side interior Drywall mud No Asbestos Detected

20 112 “” Drywall board No Asbestos Detected

21 113 S. side window Window caulk No Asbestos Detected

22 113 “” Window glazing No Asbestos Detected

23 113 S. interior Drywall system No Asbestos Detected

24 114 S. side window Window glazing No Asbestos Detected

25 114 Interior Cellulose board No Asbestos Detected

26 114 “” Drywall board No Asbestos Detected

27 124 E. side window Window glazing No Asbestos Detected

28 124 N. side interior Cellulose board No Asbestos Detected

Project Number: 550-13-114 Inspection Date: August 2, 2013 Inspector: Wes Green, IL License #100-06951 Analysis Date: August 12-14, 2013 Laboratory: EMSL Analytical, Inc. – Indianapolis, IN Accreditation: NVLAP Asbestos Bulk Accredited Laboratory #200188-0

SAMPLE

NUMBER

BUILDING SAMPLE LOCATION MATERIAL LABORATORY

ANALYSIS RESULT

29 33 1 st Fl. Dining room Window glazing No Asbestos Detected

30 33 Fireplace Refractory cement No Asbestos Detected

31 33 N. Living room Window glazing No Asbestos Detected

32 81 Ceiling Cellulose board No Asbestos Detected

33 81 N. side of garage Stucco No Asbestos Detected

34 81 S. side of garage “” No Asbestos Detected

35 81 E. side of garage “” No Asbestos Detected

36 34 Stairs to 2 nd floor Window glazing No Asbestos Detected

37 34 2 nd floor middle bedroom “” No Asbestos Detected

38 34 Living room on 1 st floor Fireplace refractory cement No Asbestos Detected

39 82 N. side of garage Stucco No Asbestos Detected

40 82 S. side of garage “” No Asbestos Detected

41 82 E. side of garage “” No Asbestos Detected

42 82 Window Window Glazing No Asbestos Detected

43 83 N. window Window Glazing No Asbestos Detected

44 83 N. side of garage Stucco No Asbestos Detected

45 83 S. side of garage “” No Asbestos Detected

46 83 E. side of garage “” No Asbestos Detected

47 83 S. side of garage Cellulose board No Asbestos Detected

48 37 2 nd floor n. window Window glazing No Asbestos Detected

49 37 1 st floor living room “” No Asbestos Detected

50 37 2 nd floor bathroom 9” floor tile & mastic No Asbestos Detected

51 41 1 st floor living room Window glazing No Asbestos Detected

52 78 N. side of garage Stucco No Asbestos Detected

53 78 S. side of garage “” No Asbestos Detected

54 78 E. side of garage “” No Asbestos Detected

55 78 E. window Window Glazing 0.75% Chrysotile Asbestos

56 31 Basement fireplace Refractory cement No Asbestos Detected

Project Number: 550-13-114 Inspection Date: August 2, 2013 Inspector: Wes Green, IL License #100-06951 Analysis Date: August 12-14, 2013 Laboratory: EMSL Analytical, Inc. – Indianapolis, IN Accreditation: NVLAP Asbestos Bulk Accredited Laboratory #200188-0

SAMPLE

NUMBER

BUILDING SAMPLE LOCATION MATERIAL LABORATORY

ANALYSIS RESULT

57 75 Garage wall Drywall No Asbestos Detected

58 75 Window Glazing No Asbestos Detected

59 75 N. side of garage Stucco No Asbestos Detected

60 75 S. side of garage “” No Asbestos Detected

61 75 E. side of garage “” No Asbestos Detected

62 32 Basement window Window glazing No Asbestos Detected

63 32 3 rd floor window “” No Asbestos Detected

64 32 Basement window “” No Asbestos Detected

65 38 Landing to 2 nd floor “” No Asbestos Detected

66 38 W. basement window “” No Asbestos Detected

APPENDIX B

LEAD CHIP SAMPLING LOG

LEAD CHIP SAMPLING INFORMATION

Project Number: 550-13-114 Inspection Date: August 2, 2013 Inspector: Wes Green, IL License #14572 Analysis Date: August 12, 2013 Laboratory: EMSL Analytical, Inc. – Indianapolis, IN Accreditation: AIHA Accredited Environmental Lead Laboratory #157245

SAMPLE BUILDING LOCATION BUILDING COMPONENT Lab Result

% Pb by weight

1 116 Exterior roof Corrugated metal 0.11%

2 110 Exterior trim Window trim 0.60%

3 110 Exterior siding Corrugated metal 0.37%

4 114 Exterior siding Corrugated metal 1.1%

5 112 Exterior window Window trim 26%

6 124 Exterior siding Corrugated metal 0.97%

7 33 Back porch Railing 7.8%

8 33 Home wood siding Wood siding 1.1%

9 34 Exterior siding Wood siding 9.0%

10 82 Exterior window Trim 17%

11 37 Exterior siding Wood siding 21%

12 41 Exterior siding Wood siding 22%

13 31 Front porch Railing 1.2%

14 32 Back porch Trim 16%

15 38 Exterior siding Wood siding 7.5%

APPENDIX C

ASBESTOS & LEAD LABORATORY

REPORT

EMSL Analytical, Inc.

APPENDIX D

INSPECTOR & LAB CERTIFICATIONS