36C25018B0093-012.pdf

PDF 9 MB Posted

Attached to
North Parking Structure 506-331 Federal contract opportunity
Solicitation number
36C25018B0093
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

36C25018B0093 S02 - 506-331 NPS - Bid Document Drawings_Part6.pdf

View the file

Other files for this federal contract opportunity

Other files attached to North Parking Structure 506-331, newest first.
File Type Posted
36C25018C0106-000.docx DOCX document
36C25018B0093-00004000.docx DOCX document
36C25018B0093-00003000.docx DOCX document
36C25018B0093-00002006.pdf PDF
36C25018B0093-00001045.pdf PDF
36C25018B0093-00001049.pdf PDF
36C25018B0093-00001002.pdf PDF
36C25018B0093-00001014.pdf PDF
36C25018B0093-00001076.pdf PDF
36C25018B0093-00001031.pdf PDF
36C25018B0093-00001054.pdf PDF
36C25018B0093-00001043.pdf PDF
36C25018B0093-00001003.pdf PDF
36C25018B0093-00001094.pdf PDF
36C25018B0093-00001061.pdf PDF
36C25018B0093-00001082.pdf PDF
36C25018B0093-00001010.pdf PDF
36C25018B0093-00001077.pdf PDF
36C25018B0093-00001039.pdf PDF
36C25018B0093-00001056.pdf PDF
36C25018B0093-00001109.pdf PDF
36C25018B0093-00001008.pdf PDF
36C25018B0093-00001093.pdf PDF
36C25018B0093-00001091.pdf PDF
36C25018B0093-00001001.pdf PDF
36C25018B0093-00001046.pdf PDF
36C25018B0093-00001078.pdf PDF
36C25018B0093-00001104.pdf PDF
36C25018B0093-00001007.pdf PDF
36C25018B0093-00001005.pdf PDF
36C25018B0093-00001018.pdf PDF
36C25018B0093-00001063.pdf PDF
36C25018B0093-00001070.pdf PDF
36C25018B0093-00001037.pdf PDF
36C25018B0093-00001107.pdf PDF
36C25018B0093-00001079.pdf PDF
36C25018B0093-00001053.pdf PDF
36C25018B0093-00001019.pdf PDF
36C25018B0093-00001089.pdf PDF
36C25018B0093-00001048.pdf PDF
36C25018B0093-00001098.pdf PDF
36C25018B0093-00001073.pdf PDF
36C25018B0093-00001055.pdf PDF
36C25018B0093-00001000.docx DOCX document
36C25018B0093-002.pdf PDF
36C25018B0093-014.pdf PDF
36C25018B0093-013.pdf PDF
36C25018B0093-004.pdf PDF
36C25018B0093-010.pdf PDF
36C25018B0093-006.pdf PDF
Show all 50

North Parking Structure 506-331 has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BOLLARD SCHEDULE

BOLLARD TYPE

LEVEL AA 16 0

LEVEL BB 0 8

LEVEL CC 0 8

LEVEL DD | D 0 18

GARAGE TOTAL 16 61

LEVEL

AT GRADE SLAB

[DETAIL 3/AP-101]

AT SUPPORTED SLAB

[DETAIL 4/AP-101]

LEVEL EE | E 0 27

5A 5B 5C

CENTER OF

DRIVE AISLE

PEDESTRIAN

SIGN

VEHICULAR

SIGN

VXX

VXX VXX

PXX

EQ

EQ EQEQ

EQ

EQ EQ

LENGTH OF SPACE LENGTH OF SPACE

3/16"

AA

SIGN SCHEDULE

SIZE

S1 1'-0" EXIT

S2 EXIT

S3 TWO-WAY TRAFFIC

S4

MARK

W L

4'-0"

TEXT / MESSAGE

SIGN

TYPE

MOUNTING

DETAIL HEIGHT

SIGN

DETAIL

REMARKS

1'-0" 4'-0"

1'-0" 4'-0"

1'-0" 3'-0" ONE WAY

ONE WAY

4'-0" V

V

V

R

RS5 / S5a 1'-0" 3'-0"

RS6 1'-6" 1'-6" DO NOT ENTER

RS7 1'-6" 1'-0" NO PARKING

PPS8 2'-0" 2'-6" LEVEL DESIGNATION

PPS9 2'-0" 2'-6" LEVEL DESIGNATION

PPS10 PROJECT SIGN LOCATE IN FIELD WITH OWNER

8'-2"

8'-2"

8'-2"

8'-2"

5'-0"

8'-2"

4'-0"

SIGN TYPE LEGEND

MARK TYPE

V VEHICULAR (RETROREFLECTIVE TEXT ONLY)

R REGULATORY (RETROREFLECTIVE)

PP PEDESTRAIN PANEL

7/AP-101 MATCH EXISTING STYLE, SIZE AND MOUNTING5B/AP-101

7/AP-101 MATCH EXISTING STYLE, SIZE AND MOUNTING5B/AP-101

8/AP-101

10/AP-101

10/AP-101

MATCH EXISTING STYLE, SIZE AND MOUNTING

MATCH EXISTING STYLE, SIZE AND MOUNTING

MATCH EXISTING STYLE, SIZE AND MOUNTING

9/AP-101 MATCH EXISTING STYLE, SIZE AND MOUNTING

5C/AP-101

5C/AP-101

5C/AP-101

5C/AP-101

5C/AP-101

1. SIGN MOUNTING HEIGHT TO BE 2" ABOVE BOTTOM OF

TEE STEM UNLESS NOTED OTHERWISE.

2. SIGN CONTRACTOR SHALL REVIEW SIGN LOCATIONS

PRIOR TO INSTALLATION WITH CONTRACTOR TO

COORDINATE WITH LIGHTING SYSTEM.

3. SIGNS SHALL BE MOUNTED LEVEL AND PLUMB, UNLESS

NOTED.

4. WHERE TWO (2) SIGNS ARE MOUNTED BACK TO BACK,

SMALLEST L DIMENSION SHALL INCREASE TO MATCH

LARGEST L DIMENSIONS.

5. MAXIMUM BOLT INSERT EMBEDMENT LENGTH 1-1/4",

UNLESS NOTED.

6. DO NOT SCALE DRAWINGS.

7. BACKS AND EDGES OF ALL ALUMINUM SIGNS MOUNTED

DIRECTLY TO STRUCTURE SHALL BE PAINTED (SIGN

BACKGROUND COLOR) TO PREVENT CATHODIC

REACTION.

8. SEE ARCHITECTURAL PLANS; A-101 THRU A-105 FOR

SIGN LOCATIONS.

9. ALL SIGN TEXT TO BE HELVETICA MEDIUM OR FRUTIGER

LT 55 ROMAN (UPPER AND LOWER CASE) UNLESS

NOTED OTHERWISE.

10. COLORS TO MATCH SIGNS IN EXISTING STRUCTURE.

11. CONTRACTOR TO CONFIRM CLEARANCE AND TO

INSTALL ALL SIGNAGE THAT REQUIRES MOUNTING

DETAIL 5C/AP-101 A MINIMUM OF 2" ABOVE ACTUAL

PARKING STRUCTURE VERTICAL CLEARANCE.

SIGNAGE GENERAL NOTES

11/AP-101

11/AP-101

MATCH EXISTING STYLE, SIZE AND MOUNTING

MATCH EXISTING STYLE, SIZE AND MOUNTING

5A/AP-101

5A/AP-101

12/AP-101 MATCH EXISTING STYLE, SIZE AND MOUNTING

LEVEL

STAIR

Two-Way Traffic

Exit

ONE WAY

DO NOT

ENTER

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

Land Development • Land Survey • Institutional • Municipal Wireless Communications • Transportation • Landfill Services

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL AA

LEVEL A

LEVEL BB

LEVEL B

LEVEL CC

LEVEL C

LEVEL DD

LEVEL D

LEVEL EE

LEVEL E

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

ABBREVIATIONS:

FIRE PROTECTION EQUIPMENT NOTES:

PIPING SYMBOLS:

PIPING DESIGNATIONS:

GENERAL NOTES:

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

HORIZONTAL EXISTING STRUCTURE

EXPANSION

LEVEL B

ELEV. 814'-10" +/-

LEVEL B

ELEV. 814'-10" +/-

SLOPE DN TO LEVEL BB

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL AA

ELEV. 798'-4" +/-

LEVEL A

ELEV. 803'-10" +/-

LEVEL A

ELEV. 803'-10" +/-

SLOPE DN TO LEVEL AA

SLOPE DN SLOPE UP TO LEVEL BB

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL BB

ELEV. 809'-4" +/-

LEVEL B

ELEV. 814'-10" +/-

SLOPE DN TO LEVEL BB

LEVEL B

ELEV. 814'-10" +/-

SLOPE DN TO LEVEL A SLOPE UP TO

LEVEL CC

HORIZONTAL EXISTING STRUCTURE

EXPANSION

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL CC

ELEV. 820'-4" +/-

LEVEL C

ELEV. 825'-10" +/-

SLOPE DN TO LEVEL CC

LEVEL C

ELEV. 825'-10" +/-

SLOPE DN TO LEVEL B SLOPE UP TO

LEVEL DD

HORIZONTAL EXISTING STRUCTURE

EXPANSION

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL DD

ELEV. 831'-4" +/-

LEVEL D

ELEV. 836'-10" +/-

LEVEL D

ELEV. 836'-10" +/-

SLOPE DN TO LEVEL DD

SLOPE DN TO LEVEL C SLOPE UP TO LEVEL EE

HORIZONTAL EXISTING STRUCTURE

EXPANSION

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL EE

ELEV. 842'-4" +/-

LEVEL E

ELEV. 847'-10" +/-

LEVEL E

ELEV. 847'-10" +/-

SLOPE DN TO LEVEL EE

SLOPE DN TO LEVEL D

HORIZONTAL EXISTING STRUCTURE

EXPANSION

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

X

ABBREVIATIONS:

AFF ABOVE FINISHED FLOOR

DEG DEGREE

EX EXISTING

EQUIPMENT TAG SYMBOLS:

KEYNOTE

PLUMBING FIXTURE SCHEDULE:

DT DRAIN TILE

SP SUMP PUMP

X-XXEQUIPMENT TAG

EQUIPMENT TYPE

# OF EACH TYPE OF

EQUIPMENT

CO FLOOR CLEANOUT

OSI OIL/WATER SEPARATOR

CB CATCH BASIN

COR CONTRACTING OFFICER'S REPRESENTATIVE

FPHB FROSTPROOF HOSE BIBB

FD FLOOR DRAIN

PIPING SYMBOLS:

INCREASER/REDUCER

PIPE DOWN

PIPE UP

DIRECTION OF FLOW

PIPE CONTINUATION

PIPE DESIGNATION

X = PIPE SIZE

X"

PIPE CAP

PIPING DESIGNATIONS:

V VENT

ST STORM

SS SANITARY

CO -1 CLEANOUT

JR SMITH OR VA APPROVED EQUAL

MODEL# 4240 WITH "TWIS-TO-FLOOR" ADJUSTABLE TOPS FOR

UNFINISHED AREAS

REFER TO DRAWINGS FOR PIPE SIZE REQUIRED

OSI-1 OIL | WATER SEPARATOR

HIGHLAND TANK SERIES-G

MODEL HT350 CYLINDRICAL SEPARATOR

SP-1, SP-2 SUMP PUMP WITH HEAVY DUTY STRUCTURAL

FOAM BASIN, "TORQUE-STOP" PUMP

RESTRAINTS, COMPRESSION MOLDED

FIBERGLASS COVER WITH NO-SKID PATTERN

LIBERTY PUMP OR VA APPROVED EQUAL

MODEL# 702/LE72A, 3/4 HP, 208 VOLT, 20 FT HEAD

MODEL# AE24L-3, 120 VOLT, CONTROL PANEL

CALCULATIONS:

DRAINAGE GPM CALCULATION:

PIPE SIZING BASED ON LOCAL RATES OF RAINFALL, PER INTERNATIONAL

PLUMBPING CODE, OF 3" PER HOUR. COVERED PARKING LEVELS ARE

CALCULATED BY CONTRIBUTION FROM WIND BLOWN RAIN. WIND BLOWN

RAIN IS BASED ON 50% OF OPEN WALL AREA TIMES RAINFALL OF 3" PER

HOUR.

GENERAL NOTES:

1. ALL DRAINAGE PIPING ABOVE GRADE SHALL BE CAST IRON WITH

NO-HUB CONNECTIONS. ALL DRAINAGE PIPING BELOW GRADE SHALL

BE CAST IRON WITH HUB AND SPIGOT CONNECTIONS. SLOPE ALL

DRAINAGE PIPING AT 1/8" PER FOOT MINIMUM UNLESS NOTED

OTHERWISE. ALL R.W.C.'S SHALL HAVE EXPANSION JOINTS LOCATED

AT EVERY OTHER LEVEL. ALL PUMP DISCHARGE LINES SHALL BE TYPE

'L' COPPER PIPE U.N.O..

2. TOP OF DRAIN GRATE SHALL BE 1/2" BELOW FINISHED FLOOR AT

SUPPORTED TIERS AND 1" AT GROUND TIER. TYPICAL FOR ALL DRAINS.

SEE STRUCTURAL DRAWINGS FOR FLOOR ELEVATIONS.

3. ALL PIPING AND RISERS EXPOSED TO POSSIBLE BUMPER DAMAGE

SHALL BE PROTECTED WITH PIPE GUARDS. SEE DETAIL #7, DRAWING

P-301.

4. PROVIDE CAST IRON PIPE SLEEVES 2" LARGER THAN PIPE OUTSIDE

DIAMETER AT GRADE SLAB PENETRATIONS. WRAP PIPES WITH 1/2"

FIBERGLASS AND SEAL OPENING WITH APPROVED SEALANT. TYPICAL

AT GRADE SLAB.

5. PROVIDE 1/3 CU. YD. CONCRETE THRUST BLOCK AT BASE OF ALL RAIN

WATER COLLECTORS AND AT ALL BENDS BELOW GRADE, FOR

SUPPORT.

6. PIPE HANGERS AND SUPPORTS SHALL BE ARRANGED SO THAT THEY

WILL SUSTAIN THE LOADS AND RETAIN THE PIPING SECURELY IN

POSITION UNDER FULLY LOADED CONDITIONS. REFER TO HANGER

DETAILS ON DRAWING P-301.

7. COORDINATE ALL BLOCK-OUTS REQUIRED WITH GENERAL

CONTRACTOR.

8. CLEANOUTS SHALL BE LOCATED AT THE BASE OF ALL DRAINAGE

RISERS AND AT OTHER LOCATIONS SHOWN ON THE DRAWINGS.

9. THE USE OF POWDER, GAS OR OTHER TYPE OF POWER PROPELLED

FASTENERS IS PROHIBITED. MOUNTING HOLES FOR ALL FASTENERS

CAST IN PLACE ADDITIONAL MOUNTING HOLES MAY BE DRILLED WITH

APPROVAL OF STRUCTURAL ENGINEER.

10. ALL PIPING AND MECHANICAL EQUIPMENT SHALL BE INSTALLED TO

MAINTAIN A MINIMUM HEADROOM CLEARANCE OF 8'-3".

NEW CONNECTION POINT

CFM CUBIC FEET PER MINUTE

KW KILLOWATTS

UH UNIT HEATER

EF EXHAUST FAN

RWC RAIN WATER CONNECTORS

FD-3 FLOOR DRAIN

HEAVY DUTY FLOOR DRAIN

JR SMITH OR VA APPROVED EQUAL

MODEL# 2295Y-U-FBS, GALVANIZED

FD-2 FLOOR DRAIN

HEAVY DUTY FLOOR DRAIN WITH TRACTOR GRATE

JR SMITH OR VA APPROVED EQUAL

MODEL# 2140C-U-M-B, GALVANIZED

FD-1 FLOOR DRAIN

HEAVY DUTY FLOOR DRAIN WITH TRACTOR GRATE

JR SMITH OR VA APPROVED EQUAL

MODEL# 2140C-U-M-B, GALVANIZED

CO -2 CLEANOUT

JR SMITH OR VA APPROVED EQUAL

MODEL# 4510 WITH COUNTERSUNK PLUG AND ROUND

ACCESS COVER

REFER TO DRAWINGS FOR PIPE SIZE REQUIRED

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL AA

ELEV. 798'-4" +/-

LEVEL A

ELEV. 803'-10" +/-

LEVEL A

ELEV. 803'-10" +/-

SLOPE DN TO LEVEL AA

SLOPE DN SLOPE UP TO LEVEL BB

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL BB

ELEV. 809'-4" +/-

LEVEL B

ELEV. 814'-10" +/-

SLOPE DN TO LEVEL BB

LEVEL B

ELEV. 814'-10" +/-

SLOPE DN TO LEVEL A SLOPE UP TO

LEVEL CC

HORIZONTAL EXISTING STRUCTURE

EXPANSION

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL CC

ELEV. 820'-4" +/-

LEVEL C

ELEV. 825'-10" +/-

SLOPE DN TO LEVEL CC

LEVEL C

ELEV. 825'-10" +/-

SLOPE DN TO LEVEL B SLOPE UP TO

LEVEL DD

HORIZONTAL EXISTING STRUCTURE

EXPANSION

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL DD

ELEV. 831'-4" +/-

LEVEL D

ELEV. 836'-10" +/-

LEVEL D

ELEV. 836'-10" +/-

SLOPE DN TO LEVEL DD

SLOPE DN TO LEVEL C SLOPE UP TO LEVEL EE

HORIZONTAL EXISTING STRUCTURE

EXPANSION

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

LEVEL EE

ELEV. 842'-4" +/-

LEVEL E

ELEV. 847'-10" +/-

LEVEL E

ELEV. 847'-10" +/-

SLOPE DN TO LEVEL EE

SLOPE DN TO LEVEL D

HORIZONTAL EXISTING STRUCTURE

EXPANSION

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com

SLOPE DN

SLOPE DN SLOPE UP TO LEVEL BB

WALKER

PARKING CONSULTANTS

525 Avis Drive, Suite 1 Ann Arbor, MI 48108

3815 Plaza Drive Ann Arbor, Michigan 48108

(734) 995-0200 • www.midwesternconsulting.com