36C24825Q0502.docx

DOCX document 24 KB Posted

Attached to
8340--Supply: Decontamination Shelter Sources Sought only Federal contract opportunity
Solicitation number
36C24825Q0502
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

This is a Sources Sought Notice for a decontamination shelter issued by the Department of Veterans Affairs Network Contracting Office 8 (NCO 8), solicitation number 36C24825Q0502. The opportunity seeks a contractor to provide a NAME BRAND OR EQUAL "Air-Shelter Model 284 inflatable Temporary Shelter" for the C.W. Bill Young Veterans Medical Center in Bay Pines, FL, with a response deadline of 03-13-2025 at 14:00 Eastern Time.

The detailed technical requirements specify a military-grade neoprene shelter between 20-30 feet long and 14-16 feet wide, with specific capabilities including air inflation in under 5 minutes, pre-plumbed decontamination shower heads, dual traffic lanes for ambulatory and non-ambulatory use, a 500-gallon waste water bladder, integrated lighting, roll-up windows and doors, and multiple accessory components like stakes, carrying bag, and maintenance kit. The solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBC), uses Product Service Code 8340 and NAICS Code 624221, and does not require additional training or software. No recovery act funds are specified, and the opportunity will be archived 7 days after the response date.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice Sources Sought Notice

SUBJECT*
Supply: Decontamination Shelter Sources Sought only

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
33744
SOLICITATION NUMBER*
36C24825Q0502
RESPONSE DATE/TIME/ZONE
03-13-2025 14:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
7 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
8340
NAICS CODE*
624221
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 8 (NCO 8)

10,000 Bay Pines Blvd Bay Pines FL 33744

POINT OF CONTACT*

Contract Specialist Michael A Shook Michael.Shook@va.gov

PLACE OF PERFORMANCE

ADDRESS
C.W. Bill Young Veterans Medical Center

10000 Bay Pines Blvd.

Bay Pines FL

POSTAL CODE
33744

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL
http://www.va.gov
URL DESCRIPTION
Department of Veterans Affairs
AGENCY CONTACT’S EMAIL ADDRESS
michael.shook@va.gov
EMAIL DESCRIPTION
Contracting Officer

DESCRIPTION

1. Scope of Work: The Emergency Management Program (EMP) has a requirement for a contractor to provide NAME BRAND OR EQUAL “Air-Shelter Model 284 inflatable Temporary Shelter (tent),” for Decontamination to be delivered to C.W. Bill Young Veterans Medical Center located at 10000 Bay Pines Blvd. Bay Pines, FL. 33744.

2. Technical Requirements: The Contractor shall provide the full requested quantity of products listed below.

Salient Characteristics

*NAME BRAND OR EQUAL*

Equipment/Product Requirement: as outlined below Air-Shelter Model 284.

a) Must be between 20ft and 30ft in length, between 14ft and 16ft in width, and an interior height of approximately 8ft.

b) Must be made of military grade neoprene that is UV/Chemical Resistant with Triple sealed seams with epoxy sealant.

c) Must be air inflatable and have air inflatable crossbeams for support.

d) Must be pre-assembled and auto inflatable with a setup time of 5 minutes or less.

e) Must Include a 110v powered inflating and deflating system/device.

f) Must be pre-plumbed with decontamination shower heads to soap/cleaning product input and rinse shower heads.

g) Must include at least 1 hanging hose line with spray nozzle.

h) Must have curtains and attachment points to utilize the tent for minimum of two lanes of traffic or individual stalls for undress, rinse/decontamination, and redress.

i) Must include a non-ambulatory roller system.

j) Must be able to use one side/lane for showers (ambulatory) and the other for non-ambulatory roller system.

k) Must have a removable ground floor with lip to catch/prevent spillage of wastewater.

l) Must have a waste/grey water bladder of at least 500 gallons.

m) Must have an electrical submersible waste pump.

n) Must have integrated or string-able lights.

o) Must have at least one roll up window on the long sides.

p) Must have at least two roll up, full zip doors per short side for dirty entry and clean exit (to allow for a minimum of two lanes of traffic flow).

q) Must have an over pressure release valve to prevent damage during inflation.

r) Must include/come with stakes and anchor points.

s) Must include/come with a carrying bag/container.

t) Must include a maintenance/repair kit for repairs.

u) Must have a minimum of 8 utility ducts.

3. Training: Not required.

4. Software: Not required.