36C24824Q0040 0001.docx

DOCX document 19 KB Posted

Attached to
J012--FY24: Fire Alarm Testing Base +4 Federal contract opportunity
Solicitation number
36C24824Q0040
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

This amendment to a previous combined solicitation is from the Department of Veterans Affairs Network Contracting Office 8 regarding solicitation number 36C24824Q0040 for fire alarm testing services at the Gainesville VAMC. The solicitation seeks annual fire alarm testing and inspection services for the base year with four option years and has a response deadline of October 24, 2023 at 12:00 PM Eastern Time. The incumbent contractor is SAFE Inc. The amendment provides responses to vendor questions, including clarification that the $5,000 allocation per year is intended for minor repairs and that anything above this amount would require separate approval and funding. It also includes an equipment list of the fire alarm system components at the facility.

View the file

Other files for this federal contract opportunity

Other files attached to J012--FY24: Fire Alarm Testing Base +4, newest first.
File Type Posted
Equipment List.pdf PDF
VHA ICARE Standards.pdf PDF
Past Performance Survey.pdf PDF
36C24824Q0040.docx DOCX document
36C24824Q0040_1.docx DOCX document
VAAR 852.219-75 Certification.docx DOCX document
VHA Seasonal Influenza Vaccination Program.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Amendment to a Previous Combined Solicitation

Amendment to a Previous Combined Solicitation

SUBJECT*
FY24: Fire Alarm Testing Base +4

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
32601-3460
SOLICITATION NUMBER*
36C24824Q0040
RESPONSE DATE/TIME/ZONE
10-24-2023 12PM EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
J012
NAICS CODE*
561621
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs

Network Contracting Office 8 (NCO 8) Commerce Building 300 E. University Ave. Ste. 180 Gainesville FL 32601-3460

POINT OF CONTACT*

Contracting Officer Todd Pappas todd.pappas@va.gov 352-374-6007

PLACE OF PERFORMANCE

ADDRESS

1601 SW Archer Rd

Gainesville FL

POSTAL CODE
32608

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

The purpose of this amendment is to incorporate the Equipment List and Responses to vendor submitted questions.

1. The responses to all vendor submitted questions are on the following pages.

2. The due date for all quotes remains at 10/24 12PM EST.

3. Quoters must acknowledge this and other amendments (if posted) on their submitted quote to be considered for award.

36C24824Q0040 – NF/SG Fire Alarm Testing and Inspection Amendment 0001 - Responses to Vendor Questions

1. Could you clarify if this is actually a requirement or to only replace the batteries that need replacing? If it is to remain as stated in the SOW, it would add a insignificant cost to the quote. Initially replace all batteries. Then only as needed (usually a 4-5 yr battery life). The $5,000 NTE is to cover incidental issues on inspection, faulty batteries, etc - if needed.

· Provide labor and materials to provide minor repairs to the Fire Alarm System not to exceed the $5000.00 allocation. Optional years shall also include a $5000.00 allocation intended for minor repairs and corrections

2. This is saying for correcting deficiencies to not exceed $5K in labor and for parts the same. But what if the work labor or parts do exceed this in order to complete? Are you aware of any actual deficiencies that need parts? Or is this something that would be brought to the attention of offers at the time of a site visit once the solicitation is published? We generally do not include repair items in our inspection proposals; we may be able to provide a Not-to-Exceed however we usually try to avoid this for the obvious reason as stated. Anything agreed on as outside scope would be a modification or separate order.

3. Is it possible to admen the SOW just in case there is a situation where any deficiencies parts and labor exceed you $5000 limit? Anything above the $5,000, if approved by VA, would be separately funded and issued as a separate order.

4. Could you provide a total quantity for the equipment list provided: A copy of the equipment list is provided with the solicitation amendment and these question responses. The facility including the Fire Alarm System is routinely changing based upon facility upgrades.

· Fire Alarm Control Panels, w Battery

· Fire Alarm Voice Evacuation Panels, Supervisory

· Auxiliary Field Module Devices

· Control Field Modules, Indicating

· Initiating Field Devices

· Notification Field Devices

· Manual Alarm Stations

· Smoke Detectors

· Heat Detectors

· Duct Smoke Detectors for Air Handlers and Dampers

· Power Supplies

· Strobes

· Speakers

· Voice Evacuation

· Batteries & Fire Alarm System components.

· DACT

· Smoke doors

5. What is the fire alarm system product manufacturer and model at the Gainesville VAMC? Notifier Fiber Optic Networked Panels with Various Models. NFS23030 System. All contractors were encouraged to participate in the walk through provided on Wednesday, 10/11/23.

6. What is the old contract number and contract amount? 36C24823P0143 - $64,340.00 (This service was an annual order – not Option yr contract).

7. Who is the incumbent / current service provider? SAFE Inc (Security and Fire Electronics Inc)

7. Is there a device/zone list? The facility including the Fire Alarm System is routinely changing based upon facility upgrades. Some devices are removed, and new devices added based on other ongoing projects.

8. What is the current inspection schedule? Yearly by third party due in November/December 2023, spot checks performed monthly by facility staff.

9. Can we obtain a copy of the last inspection report? The previous inspection reports are not relevant for pricing.

10. Are all of the devices accessible within 12 ft of height? Not all devices are accessible within 12 feet of the floor. Some devices will require ladder or lift in which to access.

See attached document: Equipment List.