36C24818R0193-014.pdf

PDF 5 MB Posted

Attached to
Upgrade Perimeter Fence Federal contract opportunity
Solicitation number
36C24818R0193
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8

About this file

36C24818R0193 S02 - Attachments - Drawings ES 05 to ES 10 Electrical [6 pages].pdf

View the file

Other files for this federal contract opportunity

Other files attached to Upgrade Perimeter Fence, newest first.
File Type Posted
36C24818R0193-00003002.docx DOCX document
36C24818R0193-00003003.pdf PDF
36C24818R0193-00003001.pdf PDF
36C24818R0193-00003000.docx DOCX document
36C24818R0193-00002000.docx DOCX document
36C24818R0193-00001000.docx DOCX document
36C24818R0193-00001001.pdf PDF
36C24818R0193-017.pdf PDF
36C24818R0193-016.pdf PDF
36C24818R0193-002.pdf PDF
36C24818R0193-006.pdf PDF
36C24818R0193-003.pdf PDF
36C24818R0193-018.docx DOCX document
36C24818R0193-007.pdf PDF
36C24818R0193-001.docx DOCX document
36C24818R0193-020.docx DOCX document
36C24818R0193-010.pdf PDF
36C24818R0193-013.pdf PDF
36C24818R0193-019.docx DOCX document
36C24818R0193-004.pdf PDF
36C24818R0193-009.pdf PDF
36C24818R0193-015.pdf PDF
36C24818R0193-005.pdf PDF
36C24818R0193-008.pdf PDF
36C24818R0193-011.pdf PDF
36C24818R0193-012.pdf PDF
36C24818R0193-000.docx DOCX document
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Revisions: Date

VACHS, SAN JUAN, PRARCHITECT/ENGINEERS:

Office of Facilities

Management

JULY-10-2016

CONSULTANTS:

GAUTIER de TORRES ARQUITECTOS

Apartado 19357, San Juan, Puerto Rico 00910-1357

(787)724-0597, (787)724-5837, INFO@1403.NET

672-12-606

VA248-14-J-4529

100%

CONSTRUCTION

DOCUMENTS

SUBMISSION

ARCHITECTS / ENGINEERS

UPGRADE PERIMETER

FENCE

L. VIDAL L. PEREZ 80

A B

C

D

E

F

SITE IMPROVEMENTS

ENLARGE SITE PLAN - AREA E

ENLARGE SITE PLAN - AREA E

SCALE 1" = 20'

Office of Facilities

Management

JULY-10-2016

CONSULTANTS:

GAUTIER de TORRES ARQUITECTOS

Apartado 19357, San Juan, Puerto Rico 00910-1357

(787)724-0597, (787)724-5837, INFO@1403.NET

672-12-606

VA248-14-J-4529

100%

CONSTRUCTION

DOCUMENTS

SUBMISSION

ARCHITECTS / ENGINEERS

UPGRADE PERIMETER

FENCE

L. VIDAL L. PEREZ 80

A B

C

D

E

F

SITE IMPROVEMENTS

ENLARGE SITE PLAN - AREA F

ENLARGE SITE PLAN - AREA F

SCALE" 1 = 20'

PULL BOX (PB-00)

4'-6" x 7'-0" x 4'-0"

AREA VERDE

TAPA RECTANGULAR

URD-30

(SPACING BETWEEN BELLS 3")

AA

PULL BOX (PB-1)

3'-0" x 3'-0" x 3'-0"

(SPACING BETWEEN BELLS 3")

PULL BOX DETAIL

NOT TO SCALE

ES-06

PULL BOX DETAIL

NOT TO SCALE

ES-06

SCALE: 1/2"=1'-0"

ES-07

EXISTING ORNAMENTAL STEEL PIPE/CONCRETE FENCE

UPGRADED ELEVATION (TYPICAL) SCALE: 1/2"=1'-0"

ES-07

NEW ORNAMENTAL STEEL PIPE/CONCRETE FENCE

ELEVATION (TYPICAL)

U.S. Department of Veterans AffairsVA

ENTRADA PRINCIPAL

Medical Center San Juan

SCALE: 1/2"=1'-0"

NEW ENTRANCE GATE 2

ELEVATION AND SIGNAGE WALL

SCALE: 1/2"=1'-0"

NEW ENTRANCE GATE 2

ELEVATION AND SIGNAGE WALL

ES-07

ES-07

U.S. Department of Veterans AffairsVA

SCALE: 1/2"=1'-0"

NEW TYPICAL ENTRANCE GATE 1 AND 3

ELEVATION (TYPICAL @ SIGNAGE WALL)

SCALE: 1/2"=1'-0"

NEW TYPICAL ENTRANCE GATE 3

ELEVATION AND SIGNAGE WALL

ES-07

ES-07

ENTRADA

MAIN ENTRACE

ENTRADA PRINCIPAL

Medical Center San Juan

MAIN ENTRACE

Medical Center San Juan

SERVICE

ENTRACE

Medical Center San Juan

TEXT- TEXT

TEXT- TEXT

TEXT- TEXT

TEXT- TEXT

DE SERVICIO

L1

TYPE

LUM.

L1

TYPE

LUM.

L1

TYPE

LUM.

L1

TYPE

LUM.

L1

TYPE

LUM.

JB JB JB

JB

JB

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

L2

TYPE

LUM.

L1

TYPE

LUM.

JB

L2

TYPE

LUM.

L2

TYPE

LUM.

L2

TYPE

LUM.

L2

TYPE

LUM.

JB

JB

L2

TYPE

LUM.

L2

TYPE

LUM.

JB

L2

TYPE

LUM.

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

L2

TYPE

LUM.

L2

TYPE

LUM.

JB

L2

TYPE

LUM.

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

L2

TYPE

LUM.

L1

TYPE

LUM.

JB

L2

TYPE

LUM.

L2

TYPE

LUM.

L2

TYPE

LUM.

L2

TYPE

LUM.

JB

JB

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

L1

TYPE

LUM.

JB

Revisions: Date

VACHS, SAN JUAN, PRARCHITECT/ENGINEERS:

Office of Facilities

Management

JULY-10-2016

CONSULTANTS:

GAUTIER de TORRES ARQUITECTOS

Apartado 19357, San Juan, Puerto Rico 00910-1357

(787)724-0597, (787)724-5837, INFO@1403.NET

672-12-606

VA248-14-J-4529

100%

CONSTRUCTION

DOCUMENTS

SUBMISSION

ARCHITECTS / ENGINEERS

UPGRADE PERIMETER

FENCE

L. VIDAL L. PEREZ 80

ELECTRICAL FENCE DETAILS

NEW ORNAMENTAL CONCRETE FENCE

ELEVATION (TYPICAL)

SCALE: 1/2"=1'-0"

NEW ENTRANCE GATE 1

ELEVATION AND SIGNAGE WALL

ES-08

SCALE: 1/2"=1'-0"

NEW ENTRANCE GATE 4

ELEVATION AND SIGNAGE WALL

ES-08

ES-08

SCALE: 1/2"=1'-0"

NEW ENTRANCE GATE EXIT

ELEVATION (SIGNAGE WALL)

ES-08

ENTRADA

Medical Center San Juan

EMERGENCY

ENTRACE

DE EMERGENCIA

ENTRADA NUM. 4

GATE NO.4

ENTRADA

Medical Center San Juan

SERVICE

ENTRACE

DE SERVICIO

L1

TYPE

LUM.

JB

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

L1

TYPE

LUM.

JB

L2

TYPE

LUM.

L2

TYPE

LUM.

L2

TYPE

LUM.

JB

JB

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

L1

TYPE

LUM.

L2

TYPE

LUM.

L2

TYPE

LUM.

L2

TYPE

LUM.

JB

JB

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

L2

TYPE

LUM.

L2

TYPE

LUM.

L2

TYPE

LUM.

JB

JB

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

JB

U.S. DepartmentVA of Veterans Affairs

CONNECTION TO

FOR ELECTRICAL

WALL SIGN.

Revisions: Date

VACHS, SAN JUAN, PRARCHITECT/ENGINEERS:

Office of Facilities

Management

JULY-10-2016

CONSULTANTS:

GAUTIER de TORRES ARQUITECTOS

Apartado 19357, San Juan, Puerto Rico 00910-1357

(787)724-0597, (787)724-5837, INFO@1403.NET

672-12-606

VA248-14-J-4529

100%

CONSTRUCTION

DOCUMENTS

SUBMISSION

ARCHITECTS / ENGINEERS

UPGRADE PERIMETER

FENCE

L. VIDAL L. PEREZ 80

SITE IMPROVEMENTS

PERIMETER FENCE

L2

TYPE

LUM.

NEW

TYPICAL ELEVATION GATE1,2 AND 3

PLATE. LOCATED ON INSIDE FACE

WITH WEATHER-PROOF COVER

FLUSH MOUNTED JUNCTION BOX

OF COLUMN. (TYP.)

ES-09

ES-09

WALL SING

JB

JB

CONNECTION TO

FOR ELECTRICAL

WALL SIGN.

SECTIONS DETAILS

Revisions: Date

VACHS, SAN JUAN, PRARCHITECT/ENGINEERS:

Office of Facilities

Management

JULY-10-2016

CONSULTANTS:

GAUTIER de TORRES ARQUITECTOS

Apartado 19357, San Juan, Puerto Rico 00910-1357

(787)724-0597, (787)724-5837, INFO@1403.NET

672-12-606

VA248-14-J-4529

100%

CONSTRUCTION

DOCUMENTS

SUBMISSION

ARCHITECTS / ENGINEERS

UPGRADE PERIMETER

FENCE

L. VIDAL L. PEREZ 8079

Office of Facilities

Management

JULY-10-2016

CONSULTANTS:

GAUTIER de TORRES ARQUITECTOS

Apartado 19357, San Juan, Puerto Rico 00910-1357

(787)724-0597, (787)724-5837, INFO@1403.NET

672-12-606

VA248-14-J-4529

100%

CONSTRUCTION

DOCUMENTS

SUBMISSION

ARCHITECTS / ENGINEERS

UPGRADE PERIMETER

FENCE

L. VIDAL L. PEREZ 80

GENERAL NOTES, LEGEND, LUMINARY AND

TIME SWITCH SCHEDULES AND DETAILS.

GENERAL NOTES:1

NUMBER

OFFON

DEVICE

DAY-OMITTING

MANUFACTURER

TYPEPOLE

AMPS/ NEMA

VOLTSDESIGNATION POLES MOUNTING

BACK-UP

BATTERY CATALOG

VATSS-1

NUMBERDESIGNATION

PANEL

LOCATION

CIRCUITS

CONTROLLED LOADS / EQUIPMENT

N U

M B

E R

R E

M A

R K

S

NUMBER DESCRIPTION

UNDERGROUND CONDUIT.

CONDUIT INSTALLED EXPOSED.

LEGEND

X

WP

J

1. ALL CONDUCTORS SHALL BE OF THE STRANDED TYPE.

(THWN-2)-600V. INSULATION.

3. UNLESS OTHERWISE INDICATED ALL CONDUCTORS SHALL BE

COPPER.

4. PROVIDE GROUND CONDUCTOR IN ALL THE CONDUITS.

5. UNLESS OTHERWISE INDICATED ALL CONDUITS SHALL BE 1" IN

DIAMETER MINIMUM.

6. PROVIDE AN EXPANSION JOINT COUPLING OF THE REQUIRED TYPE

AND SIZE WHENEVER A CONDUIT CROSSES AN EXPANSION JOINT.

7. CONTRACTOR MUST MAKE SURE THAT THE ENTIRE ELECTRICAL

SYSTEM HAS GROUND CONTINUITY.

8. ALL THE ELECTRICAL INSTALLATION SHALL BE DONE IN A NEAT &

WORKMANLIKE MANNER, ACCORDING TO THE LAST EDITION OF THE

NATIONAL ELECTRICAL CODE, (NEC) AND THE VETERANS

ADMINISTRATION LATEST STANDARDS.

9. THE CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME

ACQUAINTED WITH THE EXISTING FIELD CONDITIONS. IT SHALL BE THE

DIRECT RESPONSIBILITY OF THE CONTRACTOR TO BRING PROMPTLY TO

THE ATTENTION OF THE ENGINEER ANY DISCREPANCIES BETWEEN THE

EXISTING FIELD CONDITIONS AND THOSE THAT WERE USED FOR DESIGN

PURPOSES. THIS SHALL BE DONE BEFORE THE CONTRACTOR SUBMITS

HIS BID, SO THAT THE ENGINEER CAN RENDER A DECISION ON THE

MATTER BEFORE THE BIDS ARE RECEIVED. THE SUBMITTAL OF THE BID

BY THE CONTRACTOR WILL BE HELD AS PROOF THAT THE

CONTRACTOR UNDERSTAND THROUGHLY AND COMPLETELY THE SCOPE

OF THE WORK INVOLVED, HAS FAMILIARIZED HIMSELF WITH THE

EXISTING FIELD CONDITIONS, AND HAS INCLUDED IN HIS BID ALL THE

ITEMS NECESSARY TO PERFORM THE ELECTRICAL WORK. NO

ALLOWANCE WILL BE PERMITTED ON THIS MATTER AFTER THE BIDS

ARE RECEIVED.

10. ALL INDICATED HEIGHTS ARE FROM CENTER OF BOX AND OR

EQUIPMENT TO FINISHED FLOOR.

11. CONTRACTOR SHALL BALANCE ALL LOADS.

12. ROUTE OF CONDUITS SHOWN IN THE LAYOUT IS SCHEMATIC AND

INTENDED ONLY TO INDICATE INTERCONNECTIONS BETWEEN OUTLETS.

EXACT CONDUIT ROUTING SHALL BE DETERMINED AT THE JOB SITE TO

CONFORM WITH THE STRUCTURAL CONDITIONS AND SHALL BE SUBJECT

TO THE FINAL APPROVAL OF THE INSPECTOR'S OFFICE.

13. LEAVE A #10-AWG-TW FISHWIRE IN ALL EMPTY CONDUITS.

14. IN CONDUIT RUNS, THE NUMBER OF ARROWS DESIGNATE THE

NUMBER OF CIRCUITS IN THE CONDUIT (ONE POLE IN THE

PANELBOARD PER EACH CIRCUIT), THE NUMBER OF LINES DESIGNATE

THE NUMBER OF CONDUCTORS IN THE CONDUIT , THE LONGER LINE

BEING A NEUTRAL CONDUCTOR AND " " BEING THE GROUND

CONDUCTOR.

15. ALL THE SELF-STANDING AND SURFACE MOUNTED ELECTRICAL

EQUIPMENT AS WELL AS THE LUMINARIES SHALL ALL BE BRACED FOR

SEISMIC SHOCK ACCORDING TO THE SEISMIC RESTRAINT MANUAL

GUIDELINES FOR MECHANICAL SYSTEMS. THE SAME APPLIES TO ALL

THE CONDUIT WORK. THE DETAILS AND INSTALLATION METHODS IN SAID

MANUAL SHALL BE MODIFIED AS REQUIRED TO FIT THE ELECTRICAL

INSTALLATION OF THE PROJECT.

16. SIZES OF CONDUCTORS SHALL BE AS SPECIFIED IN FLOOR & SITE PLANS.

WEATHERPROOF COVER PLATE TO BE PROVIDED IN ALL

OUTLETS THIS SYMBOL IS SHOWN ADJACENT TO.

WALL JUNCTION BOX, FLAT BLANK COVER PLATE, 1'-6"

A.F.F. UNLESS OTHERWISE INDICATED.

L2 SLD612-8-40-WH-UNI-JB 1,2

1 SUITABLE FOR WET LOCATION, FOUR QUADRANT STYLE.

LED INSTITUTIONAL SURFACE 277 HPF 1 ED LED 15

PROVIDE STAINLESS STEEL ALLENHEAD CENTER PIN REJECT VANDALPROOF SCREWS.

18"

36"

12"

COMMON BACKFILL

CONCRETE ENVELOPE

FIN. GRADE

WARNING RIBBON

CONTINUOUS

3"

5"

6"

1"

3"

7"

1"

LIGHTING CIRCUIT

TAMPERED

(HALO)

COOPER

CONDUIT INSTALLED IN THE WALL.

CONDUIT INSTALLED IN THE FLOOR SLAB OR CONCRETE FOUNDATION.

2. UNLESS OTHERWISE INDICATED ALL CONDUCTORS SHALL BE

17. ALL CONDUITS SHALL BE PVC SCH. 40 EMBEDED IN CONCRETE EXCEPT THE

EXPOSED CONDUITS WHICH SHALL BE HEAVY WALL RIGID GALV. STEEL.

WALL LIGHTING OUTLET, 9'-0" A.F.F. OR AS INDICATED

IN SECTIONS AND DETAILS.

WALL LIGHTING OUTLET IN NIGHT LIGHT CIRCUIT, 9'-0"

A.F.F. OR AS INDICATED IN SECTIONS AND DETAILS.

SURFACE LIGHTING OUTLET.

SURFACE LIGHTING OUTLET IN NIGHT LIGHT CIRCUIT.

PANELBOARD, CENTER LINE AT 5'-0" A.F.F.

WALL MOUNTED LIGHTING CONTACTOR, CENTER LINE AT 5'-0" A.F.F.

WALL MOUNTED TIME SWITCH, CENTER LINE AT 5'-0" A.F.F.

LC

TS

L1 XTOR3ANWTWG/XTORLED WALL PACK WALL 277 HPF 1 ED LED 26 1,2

(LUMARK)

COOPER

18"

36"

12"

COMMON BACKFILL

CONCRETE ENVELOPE

FIN. GRADE

WARNING RIBBON

CONTINUOUS

3"

5"

6"

1¼"

3"

7¼"

1¼"

TAMPERED

2" 2" 2" 2" 2"

10"

2" 2" 2" 2" 2"

18"

2" 2" 2" 2"

FINISHED

GRADE

CONTINUOUS

WARNING RIBBON

COMMON BACKFILL

TAMPERED

CONCRETE ENVELOPE

PVC PLASTIC CONDUIT

DIVIDERS. MAXIMUM

DISTANCE BETWEEN

DIVIDERS 4'-0".

FINISHED

GRADE

CONTINUOUS

WARNING RIBBON

COMMON BACKFILL

TAMPERED

CONCRETE ENVELOPE

PVC PLASTIC CONDUIT

DIVIDERS. MAXIMUM

DISTANCE BETWEEN

DIVIDERS 4'-0".

18"

36"

12"

COMMON BACKFILL

CONCRETE ENVELOPE

FIN. GRADE

WARNING RIBBON

CONTINUOUS

3"

4"

6"

2"

3"

8"

2"

TAMPERED

CONDUIT

LIGHTING CIRCUIT

CONDUITS

LIGHTING CIRCUIT

CONDUIT

LIGHTING CIRCUIT

CONDUIT

LIGHTING CIRCUIT

CONDUITS

18. ALL LIGHTED SIGNS SHALL BE CONNECTED TO THEIR RESPECTIVE CANOPY

LIGHTING FIXTURES (LP4)PF-CKT C2 AS THEY WILL BE CONTROLLED THROUGH

THE SAME LIGHTING CONTACTORS & TIME SWITCHES. FOR CONNECTION

DETAILS SEE ARCHITECTURAL DRAWINGS LIGHTED SIGNS SPECIFICATIONS

& DETAILS.

2" 2" 2" 2" 2"

14"

2" 2"

PVC PLASTIC CONDUIT

DIVIDERS. MAXIMUM

DISTANCE BETWEEN

DIVIDERS 4'-0".

FINISHED

GRADE

CONTINUOUS

WARNING RIBBON

COMMON BACKFILL

TAMPERED

CONCRETE ENVELOPE

(LP4)F-C7,10

(LP4)F-C5,8

SPARE CONDUITS

(LP4)F-C3,6

(LP4)F-C1,2,4

75_672-12-606 ES-05 SITE PLAN AREA E - LIGHTING
76_672-12-606 ES-06 SITE PLAN AREA F - LIGHTING
77_672-12-606 ES-07 FENCE DETAILS
78_672-12-606 ES-08 FENCE DETAILS
79_672-12-606 ES-09 FENCE DETAILS
80_672-12-606 ES-10 GENERAL NOTES LEGEND-LUNINARY AND DETAILS