36C24818R0193-014.pdf
PDF 5 MB Posted
- Attached to
- Upgrade Perimeter Fence Federal contract opportunity
- Solicitation number
- 36C24818R0193
About this file
36C24818R0193 S02 - Attachments - Drawings ES 05 to ES 10 Electrical [6 pages].pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24818R0193-00003002.docx | DOCX document | |
| 36C24818R0193-00003003.pdf | ||
| 36C24818R0193-00003001.pdf | ||
| 36C24818R0193-00003000.docx | DOCX document | |
| 36C24818R0193-00002000.docx | DOCX document | |
| 36C24818R0193-00001000.docx | DOCX document | |
| 36C24818R0193-00001001.pdf | ||
| 36C24818R0193-017.pdf | ||
| 36C24818R0193-016.pdf | ||
| 36C24818R0193-002.pdf | ||
| 36C24818R0193-006.pdf | ||
| 36C24818R0193-003.pdf | ||
| 36C24818R0193-018.docx | DOCX document | |
| 36C24818R0193-007.pdf | ||
| 36C24818R0193-001.docx | DOCX document | |
| 36C24818R0193-020.docx | DOCX document | |
| 36C24818R0193-010.pdf | ||
| 36C24818R0193-013.pdf | ||
| 36C24818R0193-019.docx | DOCX document | |
| 36C24818R0193-004.pdf | ||
| 36C24818R0193-009.pdf | ||
| 36C24818R0193-015.pdf | ||
| 36C24818R0193-005.pdf | ||
| 36C24818R0193-008.pdf | ||
| 36C24818R0193-011.pdf | ||
| 36C24818R0193-012.pdf | ||
| 36C24818R0193-000.docx | DOCX document |
Show all 27
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Revisions: Date
VACHS, SAN JUAN, PRARCHITECT/ENGINEERS:
Office of Facilities
Management
JULY-10-2016
CONSULTANTS:
GAUTIER de TORRES ARQUITECTOS
Apartado 19357, San Juan, Puerto Rico 00910-1357
(787)724-0597, (787)724-5837, INFO@1403.NET
672-12-606
VA248-14-J-4529
100%
CONSTRUCTION
DOCUMENTS
SUBMISSION
ARCHITECTS / ENGINEERS
UPGRADE PERIMETER
FENCE
L. VIDAL L. PEREZ 80
A B
C
D
E
F
SITE IMPROVEMENTS
ENLARGE SITE PLAN - AREA E
ENLARGE SITE PLAN - AREA E
SCALE 1" = 20'
Office of Facilities
Management
JULY-10-2016
CONSULTANTS:
GAUTIER de TORRES ARQUITECTOS
Apartado 19357, San Juan, Puerto Rico 00910-1357
(787)724-0597, (787)724-5837, INFO@1403.NET
672-12-606
VA248-14-J-4529
100%
CONSTRUCTION
DOCUMENTS
SUBMISSION
ARCHITECTS / ENGINEERS
UPGRADE PERIMETER
FENCE
L. VIDAL L. PEREZ 80
A B
C
D
E
F
SITE IMPROVEMENTS
ENLARGE SITE PLAN - AREA F
ENLARGE SITE PLAN - AREA F
SCALE" 1 = 20'
PULL BOX (PB-00)
4'-6" x 7'-0" x 4'-0"
AREA VERDE
TAPA RECTANGULAR
URD-30
(SPACING BETWEEN BELLS 3")
AA
PULL BOX (PB-1)
3'-0" x 3'-0" x 3'-0"
(SPACING BETWEEN BELLS 3")
PULL BOX DETAIL
NOT TO SCALE
ES-06
PULL BOX DETAIL
NOT TO SCALE
ES-06
SCALE: 1/2"=1'-0"
ES-07
EXISTING ORNAMENTAL STEEL PIPE/CONCRETE FENCE
UPGRADED ELEVATION (TYPICAL) SCALE: 1/2"=1'-0"
ES-07
NEW ORNAMENTAL STEEL PIPE/CONCRETE FENCE
ELEVATION (TYPICAL)
U.S. Department of Veterans AffairsVA
ENTRADA PRINCIPAL
Medical Center San Juan
SCALE: 1/2"=1'-0"
NEW ENTRANCE GATE 2
ELEVATION AND SIGNAGE WALL
SCALE: 1/2"=1'-0"
NEW ENTRANCE GATE 2
ELEVATION AND SIGNAGE WALL
ES-07
ES-07
U.S. Department of Veterans AffairsVA
SCALE: 1/2"=1'-0"
NEW TYPICAL ENTRANCE GATE 1 AND 3
ELEVATION (TYPICAL @ SIGNAGE WALL)
SCALE: 1/2"=1'-0"
NEW TYPICAL ENTRANCE GATE 3
ELEVATION AND SIGNAGE WALL
ES-07
ES-07
ENTRADA
MAIN ENTRACE
ENTRADA PRINCIPAL
Medical Center San Juan
MAIN ENTRACE
Medical Center San Juan
SERVICE
ENTRACE
Medical Center San Juan
TEXT- TEXT
TEXT- TEXT
TEXT- TEXT
TEXT- TEXT
DE SERVICIO
L1
TYPE
LUM.
L1
TYPE
LUM.
L1
TYPE
LUM.
L1
TYPE
LUM.
L1
TYPE
LUM.
JB JB JB
JB
JB
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
L2
TYPE
LUM.
L1
TYPE
LUM.
JB
L2
TYPE
LUM.
L2
TYPE
LUM.
L2
TYPE
LUM.
L2
TYPE
LUM.
JB
JB
L2
TYPE
LUM.
L2
TYPE
LUM.
JB
L2
TYPE
LUM.
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
L2
TYPE
LUM.
L2
TYPE
LUM.
JB
L2
TYPE
LUM.
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
L2
TYPE
LUM.
L1
TYPE
LUM.
JB
L2
TYPE
LUM.
L2
TYPE
LUM.
L2
TYPE
LUM.
L2
TYPE
LUM.
JB
JB
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
L1
TYPE
LUM.
JB
Revisions: Date
VACHS, SAN JUAN, PRARCHITECT/ENGINEERS:
Office of Facilities
Management
JULY-10-2016
CONSULTANTS:
GAUTIER de TORRES ARQUITECTOS
Apartado 19357, San Juan, Puerto Rico 00910-1357
(787)724-0597, (787)724-5837, INFO@1403.NET
672-12-606
VA248-14-J-4529
100%
CONSTRUCTION
DOCUMENTS
SUBMISSION
ARCHITECTS / ENGINEERS
UPGRADE PERIMETER
FENCE
L. VIDAL L. PEREZ 80
ELECTRICAL FENCE DETAILS
NEW ORNAMENTAL CONCRETE FENCE
ELEVATION (TYPICAL)
SCALE: 1/2"=1'-0"
NEW ENTRANCE GATE 1
ELEVATION AND SIGNAGE WALL
ES-08
SCALE: 1/2"=1'-0"
NEW ENTRANCE GATE 4
ELEVATION AND SIGNAGE WALL
ES-08
ES-08
SCALE: 1/2"=1'-0"
NEW ENTRANCE GATE EXIT
ELEVATION (SIGNAGE WALL)
ES-08
ENTRADA
Medical Center San Juan
EMERGENCY
ENTRACE
DE EMERGENCIA
ENTRADA NUM. 4
GATE NO.4
ENTRADA
Medical Center San Juan
SERVICE
ENTRACE
DE SERVICIO
L1
TYPE
LUM.
JB
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
L1
TYPE
LUM.
JB
L2
TYPE
LUM.
L2
TYPE
LUM.
L2
TYPE
LUM.
JB
JB
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
L1
TYPE
LUM.
L2
TYPE
LUM.
L2
TYPE
LUM.
L2
TYPE
LUM.
JB
JB
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
L2
TYPE
LUM.
L2
TYPE
LUM.
L2
TYPE
LUM.
JB
JB
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
JB
U.S. DepartmentVA of Veterans Affairs
CONNECTION TO
FOR ELECTRICAL
WALL SIGN.
Revisions: Date
VACHS, SAN JUAN, PRARCHITECT/ENGINEERS:
Office of Facilities
Management
JULY-10-2016
CONSULTANTS:
GAUTIER de TORRES ARQUITECTOS
Apartado 19357, San Juan, Puerto Rico 00910-1357
(787)724-0597, (787)724-5837, INFO@1403.NET
672-12-606
VA248-14-J-4529
100%
CONSTRUCTION
DOCUMENTS
SUBMISSION
ARCHITECTS / ENGINEERS
UPGRADE PERIMETER
FENCE
L. VIDAL L. PEREZ 80
SITE IMPROVEMENTS
PERIMETER FENCE
L2
TYPE
LUM.
NEW
TYPICAL ELEVATION GATE1,2 AND 3
PLATE. LOCATED ON INSIDE FACE
WITH WEATHER-PROOF COVER
FLUSH MOUNTED JUNCTION BOX
OF COLUMN. (TYP.)
ES-09
ES-09
WALL SING
JB
JB
CONNECTION TO
FOR ELECTRICAL
WALL SIGN.
SECTIONS DETAILS
Revisions: Date
VACHS, SAN JUAN, PRARCHITECT/ENGINEERS:
Office of Facilities
Management
JULY-10-2016
CONSULTANTS:
GAUTIER de TORRES ARQUITECTOS
Apartado 19357, San Juan, Puerto Rico 00910-1357
(787)724-0597, (787)724-5837, INFO@1403.NET
672-12-606
VA248-14-J-4529
100%
CONSTRUCTION
DOCUMENTS
SUBMISSION
ARCHITECTS / ENGINEERS
UPGRADE PERIMETER
FENCE
L. VIDAL L. PEREZ 8079
Office of Facilities
Management
JULY-10-2016
CONSULTANTS:
GAUTIER de TORRES ARQUITECTOS
Apartado 19357, San Juan, Puerto Rico 00910-1357
(787)724-0597, (787)724-5837, INFO@1403.NET
672-12-606
VA248-14-J-4529
100%
CONSTRUCTION
DOCUMENTS
SUBMISSION
ARCHITECTS / ENGINEERS
UPGRADE PERIMETER
FENCE
L. VIDAL L. PEREZ 80
GENERAL NOTES, LEGEND, LUMINARY AND
TIME SWITCH SCHEDULES AND DETAILS.
GENERAL NOTES:1
NUMBER
OFFON
DEVICE
DAY-OMITTING
MANUFACTURER
TYPEPOLE
AMPS/ NEMA
VOLTSDESIGNATION POLES MOUNTING
BACK-UP
BATTERY CATALOG
VATSS-1
NUMBERDESIGNATION
PANEL
LOCATION
CIRCUITS
CONTROLLED LOADS / EQUIPMENT
N U
M B
E R
R E
M A
R K
S
NUMBER DESCRIPTION
UNDERGROUND CONDUIT.
CONDUIT INSTALLED EXPOSED.
LEGEND
X
WP
J
1. ALL CONDUCTORS SHALL BE OF THE STRANDED TYPE.
(THWN-2)-600V. INSULATION.
3. UNLESS OTHERWISE INDICATED ALL CONDUCTORS SHALL BE
COPPER.
4. PROVIDE GROUND CONDUCTOR IN ALL THE CONDUITS.
5. UNLESS OTHERWISE INDICATED ALL CONDUITS SHALL BE 1" IN
DIAMETER MINIMUM.
6. PROVIDE AN EXPANSION JOINT COUPLING OF THE REQUIRED TYPE
AND SIZE WHENEVER A CONDUIT CROSSES AN EXPANSION JOINT.
7. CONTRACTOR MUST MAKE SURE THAT THE ENTIRE ELECTRICAL
SYSTEM HAS GROUND CONTINUITY.
8. ALL THE ELECTRICAL INSTALLATION SHALL BE DONE IN A NEAT &
WORKMANLIKE MANNER, ACCORDING TO THE LAST EDITION OF THE
NATIONAL ELECTRICAL CODE, (NEC) AND THE VETERANS
ADMINISTRATION LATEST STANDARDS.
9. THE CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME
ACQUAINTED WITH THE EXISTING FIELD CONDITIONS. IT SHALL BE THE
DIRECT RESPONSIBILITY OF THE CONTRACTOR TO BRING PROMPTLY TO
THE ATTENTION OF THE ENGINEER ANY DISCREPANCIES BETWEEN THE
EXISTING FIELD CONDITIONS AND THOSE THAT WERE USED FOR DESIGN
PURPOSES. THIS SHALL BE DONE BEFORE THE CONTRACTOR SUBMITS
HIS BID, SO THAT THE ENGINEER CAN RENDER A DECISION ON THE
MATTER BEFORE THE BIDS ARE RECEIVED. THE SUBMITTAL OF THE BID
BY THE CONTRACTOR WILL BE HELD AS PROOF THAT THE
CONTRACTOR UNDERSTAND THROUGHLY AND COMPLETELY THE SCOPE
OF THE WORK INVOLVED, HAS FAMILIARIZED HIMSELF WITH THE
EXISTING FIELD CONDITIONS, AND HAS INCLUDED IN HIS BID ALL THE
ITEMS NECESSARY TO PERFORM THE ELECTRICAL WORK. NO
ALLOWANCE WILL BE PERMITTED ON THIS MATTER AFTER THE BIDS
ARE RECEIVED.
10. ALL INDICATED HEIGHTS ARE FROM CENTER OF BOX AND OR
EQUIPMENT TO FINISHED FLOOR.
11. CONTRACTOR SHALL BALANCE ALL LOADS.
12. ROUTE OF CONDUITS SHOWN IN THE LAYOUT IS SCHEMATIC AND
INTENDED ONLY TO INDICATE INTERCONNECTIONS BETWEEN OUTLETS.
EXACT CONDUIT ROUTING SHALL BE DETERMINED AT THE JOB SITE TO
CONFORM WITH THE STRUCTURAL CONDITIONS AND SHALL BE SUBJECT
TO THE FINAL APPROVAL OF THE INSPECTOR'S OFFICE.
13. LEAVE A #10-AWG-TW FISHWIRE IN ALL EMPTY CONDUITS.
14. IN CONDUIT RUNS, THE NUMBER OF ARROWS DESIGNATE THE
NUMBER OF CIRCUITS IN THE CONDUIT (ONE POLE IN THE
PANELBOARD PER EACH CIRCUIT), THE NUMBER OF LINES DESIGNATE
THE NUMBER OF CONDUCTORS IN THE CONDUIT , THE LONGER LINE
BEING A NEUTRAL CONDUCTOR AND " " BEING THE GROUND
CONDUCTOR.
15. ALL THE SELF-STANDING AND SURFACE MOUNTED ELECTRICAL
EQUIPMENT AS WELL AS THE LUMINARIES SHALL ALL BE BRACED FOR
SEISMIC SHOCK ACCORDING TO THE SEISMIC RESTRAINT MANUAL
GUIDELINES FOR MECHANICAL SYSTEMS. THE SAME APPLIES TO ALL
THE CONDUIT WORK. THE DETAILS AND INSTALLATION METHODS IN SAID
MANUAL SHALL BE MODIFIED AS REQUIRED TO FIT THE ELECTRICAL
INSTALLATION OF THE PROJECT.
16. SIZES OF CONDUCTORS SHALL BE AS SPECIFIED IN FLOOR & SITE PLANS.
WEATHERPROOF COVER PLATE TO BE PROVIDED IN ALL
OUTLETS THIS SYMBOL IS SHOWN ADJACENT TO.
WALL JUNCTION BOX, FLAT BLANK COVER PLATE, 1'-6"
A.F.F. UNLESS OTHERWISE INDICATED.
L2 SLD612-8-40-WH-UNI-JB 1,2
1 SUITABLE FOR WET LOCATION, FOUR QUADRANT STYLE.
LED INSTITUTIONAL SURFACE 277 HPF 1 ED LED 15
PROVIDE STAINLESS STEEL ALLENHEAD CENTER PIN REJECT VANDALPROOF SCREWS.
18"
36"
12"
COMMON BACKFILL
CONCRETE ENVELOPE
FIN. GRADE
WARNING RIBBON
CONTINUOUS
3"
5"
6"
1"
3"
7"
1"
LIGHTING CIRCUIT
TAMPERED
(HALO)
COOPER
CONDUIT INSTALLED IN THE WALL.
CONDUIT INSTALLED IN THE FLOOR SLAB OR CONCRETE FOUNDATION.
2. UNLESS OTHERWISE INDICATED ALL CONDUCTORS SHALL BE
17. ALL CONDUITS SHALL BE PVC SCH. 40 EMBEDED IN CONCRETE EXCEPT THE
EXPOSED CONDUITS WHICH SHALL BE HEAVY WALL RIGID GALV. STEEL.
WALL LIGHTING OUTLET, 9'-0" A.F.F. OR AS INDICATED
IN SECTIONS AND DETAILS.
WALL LIGHTING OUTLET IN NIGHT LIGHT CIRCUIT, 9'-0"
A.F.F. OR AS INDICATED IN SECTIONS AND DETAILS.
SURFACE LIGHTING OUTLET.
SURFACE LIGHTING OUTLET IN NIGHT LIGHT CIRCUIT.
PANELBOARD, CENTER LINE AT 5'-0" A.F.F.
WALL MOUNTED LIGHTING CONTACTOR, CENTER LINE AT 5'-0" A.F.F.
WALL MOUNTED TIME SWITCH, CENTER LINE AT 5'-0" A.F.F.
LC
TS
L1 XTOR3ANWTWG/XTORLED WALL PACK WALL 277 HPF 1 ED LED 26 1,2
(LUMARK)
COOPER
18"
36"
12"
COMMON BACKFILL
CONCRETE ENVELOPE
FIN. GRADE
WARNING RIBBON
CONTINUOUS
3"
5"
6"
1¼"
3"
7¼"
1¼"
TAMPERED
2" 2" 2" 2" 2"
10"
2" 2" 2" 2" 2"
18"
2" 2" 2" 2"
FINISHED
GRADE
CONTINUOUS
WARNING RIBBON
COMMON BACKFILL
TAMPERED
CONCRETE ENVELOPE
PVC PLASTIC CONDUIT
DIVIDERS. MAXIMUM
DISTANCE BETWEEN
DIVIDERS 4'-0".
FINISHED
GRADE
CONTINUOUS
WARNING RIBBON
COMMON BACKFILL
TAMPERED
CONCRETE ENVELOPE
PVC PLASTIC CONDUIT
DIVIDERS. MAXIMUM
DISTANCE BETWEEN
DIVIDERS 4'-0".
18"
36"
12"
COMMON BACKFILL
CONCRETE ENVELOPE
FIN. GRADE
WARNING RIBBON
CONTINUOUS
3"
4"
6"
2"
3"
8"
2"
TAMPERED
CONDUIT
LIGHTING CIRCUIT
CONDUITS
LIGHTING CIRCUIT
CONDUIT
LIGHTING CIRCUIT
CONDUIT
LIGHTING CIRCUIT
CONDUITS
18. ALL LIGHTED SIGNS SHALL BE CONNECTED TO THEIR RESPECTIVE CANOPY
LIGHTING FIXTURES (LP4)PF-CKT C2 AS THEY WILL BE CONTROLLED THROUGH
THE SAME LIGHTING CONTACTORS & TIME SWITCHES. FOR CONNECTION
DETAILS SEE ARCHITECTURAL DRAWINGS LIGHTED SIGNS SPECIFICATIONS
& DETAILS.
2" 2" 2" 2" 2"
14"
2" 2"
PVC PLASTIC CONDUIT
DIVIDERS. MAXIMUM
DISTANCE BETWEEN
DIVIDERS 4'-0".
FINISHED
GRADE
CONTINUOUS
WARNING RIBBON
COMMON BACKFILL
TAMPERED
CONCRETE ENVELOPE
(LP4)F-C7,10
(LP4)F-C5,8
SPARE CONDUITS
(LP4)F-C3,6
(LP4)F-C1,2,4
| 75_672-12-606 ES-05 SITE PLAN AREA E - LIGHTING |
| 76_672-12-606 ES-06 SITE PLAN AREA F - LIGHTING |
| 77_672-12-606 ES-07 FENCE DETAILS |
| 78_672-12-606 ES-08 FENCE DETAILS |
| 79_672-12-606 ES-09 FENCE DETAILS |
| 80_672-12-606 ES-10 GENERAL NOTES LEGEND-LUNINARY AND DETAILS |
File details come from the government source that posted it.