36C24722Q0743_2.docx

DOCX document 14 KB Posted

Attached to
6515--Cirrus 5000 Unit Address correction Federal contract opportunity
Solicitation number
36C24722Q0743
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 7

About this file

This notice modifies a previous solicitation seeking a Cirrus 5000 Unit with OCT Angiography capability from the Department of Veterans Affairs. The solicitation requests pricing for three Cirrus HD OCT Model 5000 systems with AngioPlex OCT Angiography software and additional capabilities. Responses are due by June 14, 2022. The solicitation also includes a trade-in offer for one existing Cirrus 5000 serial number TBD. The place of performance is the Carl Vinson VA Medical Center in Dublin, Georgia. The solicited system performs tomography scans of eye structures to provide physicians information on health and viability to guide treatment.

View the file

Other files for this federal contract opportunity

Other files attached to 6515--Cirrus 5000 Unit Address correction, newest first.
File Type Posted
36C24722Q0743_3.docx DOCX document
36C24722Q0743.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Modification to a Previous Notice Modification to a Previous Notice

SUBJECT*
Cirrus 5000 Unit

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
31021
SOLICITATION NUMBER*
36C24722Q0743

BASE NOTICE TYPE

RESPONSE DATE/TIME/ZONE
06-14-2022 10:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
60 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SDVOSBC
PRODUCT SERVICE CODE*
6515
NAICS CODE*
339112

CONTRACTING OFFICE ADDRESS

POINT OF CONTACT*

PLACE OF PERFORMANCE

ADDRESS

POSTAL CODE

COUNTRY

ADDITIONAL INFORMATION

AGENCY’S URL

URL DESCRIPTION

AGENCY CONTACT’S EMAIL ADDRESS

EMAIL DESCRIPTION

DESCRIPTION

SALIENT REQUIREMENT -CIRRUS HD-OCT Model 5000

Has the capability to have the ability to capture and provide OCT Angiography:

This capability for OCT Angiography is provided by a 1 single OCT scan Has the ability to import and integrate raw data from the CIRRUS family of products. The raw data must be interchangeable between the CIRRUS units Must allow for the ability of FORUM Retina Workplace, Glaucoma Workplace to access all DICOM private and public tags.

The unit must have exact Macular Scan Pattern of 512x128 for retina scan that is 6x6mm scan area.

Scanning speeds: Scan at exactly 27,000 A-scans/sec, as well as the ability to scan at exactly 68,000 A-scans/sec The unit must be able to compare 8 tests in one glance under the GPA Glaucoma Progression Analysis in one view. (2 baseline, 6 subsequent visits.

Unit must be able to provide a report for Ganglion Cell Analysis that is derived from a scan must be comprised of 6mmx6mm cube scan with a minimum by 200x200 line scan pattern Anterior Segment scan that is at minimal 15.5 mm in length x 5.8 mm in depth.

which is the full view of the Anterior Chamber.

Global Pachymetry report that is comprised of minimum of 24 radial scans and must be at a minimum 9mm in length.