36C24722Q0743_2.docx
DOCX document 14 KB Posted
- Attached to
- 6515--Cirrus 5000 Unit Address correction Federal contract opportunity
- Solicitation number
- 36C24722Q0743
About this file
This notice modifies a previous solicitation seeking a Cirrus 5000 Unit with OCT Angiography capability from the Department of Veterans Affairs. The solicitation requests pricing for three Cirrus HD OCT Model 5000 systems with AngioPlex OCT Angiography software and additional capabilities. Responses are due by June 14, 2022. The solicitation also includes a trade-in offer for one existing Cirrus 5000 serial number TBD. The place of performance is the Carl Vinson VA Medical Center in Dublin, Georgia. The solicited system performs tomography scans of eye structures to provide physicians information on health and viability to guide treatment.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24722Q0743_3.docx | DOCX document | |
| 36C24722Q0743.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Modification to a Previous Notice Modification to a Previous Notice
| SUBJECT* |
| Cirrus 5000 Unit |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 31021 |
| SOLICITATION NUMBER* |
| 36C24722Q0743 |
BASE NOTICE TYPE
| RESPONSE DATE/TIME/ZONE |
| 06-14-2022 10:00 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
| SET-ASIDE |
| SDVOSBC |
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339112 |
CONTRACTING OFFICE ADDRESS
POINT OF CONTACT*
PLACE OF PERFORMANCE
ADDRESS
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
SALIENT REQUIREMENT -CIRRUS HD-OCT Model 5000
Has the capability to have the ability to capture and provide OCT Angiography:
This capability for OCT Angiography is provided by a 1 single OCT scan Has the ability to import and integrate raw data from the CIRRUS family of products. The raw data must be interchangeable between the CIRRUS units Must allow for the ability of FORUM Retina Workplace, Glaucoma Workplace to access all DICOM private and public tags.
The unit must have exact Macular Scan Pattern of 512x128 for retina scan that is 6x6mm scan area.
Scanning speeds: Scan at exactly 27,000 A-scans/sec, as well as the ability to scan at exactly 68,000 A-scans/sec The unit must be able to compare 8 tests in one glance under the GPA Glaucoma Progression Analysis in one view. (2 baseline, 6 subsequent visits.
Unit must be able to provide a report for Ganglion Cell Analysis that is derived from a scan must be comprised of 6mmx6mm cube scan with a minimum by 200x200 line scan pattern Anterior Segment scan that is at minimal 15.5 mm in length x 5.8 mm in depth.
which is the full view of the Anterior Chamber.
Global Pachymetry report that is comprised of minimum of 24 radial scans and must be at a minimum 9mm in length.