36C24619Q0750-007.pdf
PDF 164 KB Posted
- Attached to
- 659-19-104 Replace WindowsB3-B6-B12-B14W-B19 Federal contract opportunity
- Solicitation number
- 36C24619Q0750
About this file
36C24619Q0750 659-19-112_Division 08 Openings.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24619Q0750-0002000.docx | DOCX document | |
| 36C24619Q0750-0001000.pdf | ||
| 36C24619Q0750-008.pdf | ||
| 36C24619Q0750-006.pdf | ||
| 36C24619Q0750-002.pdf | ||
| 36C24619Q0750-001.pdf | ||
| 36C24619Q0750-003.pdf | ||
| 36C24619Q0750-004.pdf | ||
| 36C24619Q0750-005.pdf | ||
| 36C24619Q0750-009.pdf | ||
| 36C24619Q0750-000.docx | DOCX document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
08-01-16
08 51 13.11 - 1
SECTION 08 51 13.11
SIDE-HINGED ALUMINUM WINDOWS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Side hinged, in-swing casement type windows renovation work.
2. Enclosed venetian blinds.
3. Window hardware and accessories.
1.2 RELATED REQUIREMENTS
A. Sealing Joints: Section 07 92 00, JOINT SEALANTS.
B. Glazing: Section 08 80 00, GLAZING.
C. Window Color: White.
1.3 APPLICABLE PUBLICATIONS
A. Comply with references to extent specified in this section.
B. American Architectural Manufacturers Associations (AAMA):
1. AAMA/WDMA/CSA 101/I.S.2/A440-11 - Windows, Doors, and Skylights.
2. 502-12 - Field Testing of Newly Installed Fenestration Products.
3. 505-09 - Dry Shrinkage and Composite Performance Thermal Cycling
Test Procedures.
4. 2605-13 - Performance Requirements and Test Procedures for Superior
Performing Organic Coatings on Aluminum Extrusions and Panels.
5. TIR A8-08 - Structural Performance of Composite Thermal Barrier
Framing System.
C. American Society of Civil Engineers/Structural Engineering Institute
(ASCE/SEI):
1. 7-10 - Minimum Design Loads for Buildings and Other Structures.
D. American Society of Heating, Refrigerating and Air Conditioning
Engineers (ASHRAE):
1. 90.1-13 - Energy Standard for Buildings Except Low Rise Residential
Buildings.
E. ASTM International (ASTM):
1. B209-14 - Aluminum and Aluminum-Alloy Sheet and Plate.
2. B209M-14 - Aluminum and Aluminum-Alloy Sheet and Plate (Metric).
3. B221-14 - Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.
4. B221M 13 - Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, E283-04(2012) - Determining Rate of Air Leakage Through Exterior
08 51 13.11 - 2
Windows, Curtain Walls, and Doors Under Specified Pressure
Differences Across the Specimen.
5. E331-00(2009) - Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference.
F. National Association of Architectural Metal Manufacturers (NAAMM):
1. AMP 500 Series - Metal Finishes Manual.
1.4 PRE-INSTALLATION MEETINGS
A. Conduct pre-installation meeting at project site minimum 30 days before beginning Work of this section.
1. Required Participants:
a. Contracting Officer's Representative.
b. Architect/Engineer.
c. Inspection and Testing Agency.
d. Contractor.
e. Installer.
f. Manufacturer's field representative.
g. Other installers responsible for adjacent and intersecting work, including weather barrier installer.
2. Meeting Agenda: Distribute agenda to participants minimum 3 days before meeting.
a. Installation schedule.
b. Installation sequence.
c. Preparatory work.
d. Protection before, during, and after installation.
e. Installation.
f. Terminations.
g. Transitions and connections to other work.
h. Inspecting and testing.
i. Other items affecting successful completion.
3. Document and distribute meeting minutes to participants to record decisions affecting installation.
1.5 SUBMITTALS
A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
B. Submittal Drawings:
1. Show size, configuration, and fabrication and installation details.
2. Details of metal trim, including anchorages.
08 51 13.11 - 3
3. Include glazing details and standards for factory glazed units.
C. Manufacturer's Literature and Data:
1. Description of each product.
2. Installation instructions.
3. Warranty.
D. Samples: (Not Used)
E. Test reports: Certify each product complies with specifications.
1. Windows.
2. Operating hardware.
F. Certificates: Certify each product complies with specifications.
1. Windows.
a. Architectural Aluminum Manufacturer Association, “AAMA label” affixed to each window indicating compliance with specification.
b. Certificates in lieu of label with copy of recent test report
(maximum four years old) from an independent testing laboratory and certificate signed by window manufacturer stating that windows provided comply with specified requirements and
AAMA/WDMA/CAS 101/I.S.2 for type of window specified.
G. Operation and Maintenance Data:
1. Care instructions for each exposed finish product.
1.6 QUALITY ASSURANCE
A. Manufacturer Qualifications:
1. Regularly manufactures specified products.
2. Manufactured specified products with satisfactory service on five similar installations for minimum five years.
a. Provide contact names and addresses for completed projects when requested by Contracting Officer's Representative.
B. Quality Certified Labels or Certificates:
1. AAMA Label affixed to each window indicating compliance with specification.
2. Certificates in lieu of label with copy of test report maximum 4 years old from independent testing laboratory and certificate signed by window manufacturer stating that windows provided comply with specified requirements and AAMA/WDMA/CSA 101/I.S.2/A440 for type of window specified.
1.7 DELIVERY
A. Deliver products in manufacturer's original sealed packaging.
08 51 13.11 - 4
B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, production run number, and manufacture date.
C. Before installation, return or dispose of products within distorted, damaged, or opened packaging.
1.8 STORAGE AND HANDLING
A. Protect windows from damage during handling and construction operations before, during and after installation.
B. Store windows under cover, setting upright.
C. Do not stack windows flat.
D. Do not lay building materials or equipment on windows.
1.9 WARRANTY
A. Construction Warranty: FAR clause 52.246-21, "Warranty of
Construction."
1. Warranty Period: 1 year from completion.
B. Manufacturer's Warranty: Warrant windows against material and manufacturing defects.
1. Warranty Period: 10 years.
PART 2 - PRODUCTS
2.1 SYSTEM PERFORMANCE
A. Design windows complying with specified performance:
1. Load Resistance: ASCE/SEI 7.
a. Performance Grade: AAMA/WDMA/CSA 101/I.S.2/A440 required to resist maximum positive and negative wind load.
2. Thermal Transmittance: Maximum U-value W/sq. m/degree K
(Btu/sq. ft./hr./degree F).
a. Insulating Glass Windows: U-2.8 (U-0.5).
b. Triple Glazed Windows: U-4.0 (U-0.7), or as required by
ASHRAE 90.1.
3. Condensation Resistance Factor (CRF): NFRC 500 Minimum CRF of 45.
4. Water Resistance: ASTM E331; No uncontrolled penetration at 220 Pa
(4.50 psf), minimum, pressure differential.
5. Air Infiltration Resistance: ASTM E283; 1.5 L/s/sq. m (0.3 cfm/sq. ft.), maximum at 75 Pa (1.57 psf), minimum, pressure differential.
6. Performance Class and Grade: AAMA/WDMA/CSA 101/I.S.2/A440, minimum
AW-40.
08 51 13.11 - 5
2.2 MATERIALS
A. Aluminum Extrusions: ASTM B221M (ASTM B221); 6063 alloy, T5 temper.
B. Aluminum Sheet: ASTM B209M (ASTM B209); 5005 alloy, H15 or H34 temper.
2.3 PRODUCTS - GENERAL
A. Basis of Design: Peerless Product Inc.
B. Provide windows from one manufacturer (Peerless Product Inc).
C. Sustainable Construction Requirements:
1. Aluminum Recycled Content: 80 total recycled content, minimum.
2.4 ALUMINUM WINDOWS
A. Frames and Sashes: Aluminum extrusions, AAMA/WDMA/CSA 101/I.S.2/A440.
B. Thermal-Break Window Construction:
1. Manufacturer’s Standard.
2. Low conductance thermal barrier.
3. Capable of structurally holding sash in position and together.
4. Thermal Break Assemblies: Tested according to AAMA TIR A8 and
AAMA 505.
5. Design location of thermal break so that, in closed position, outside air does not come in direct contact with interior frame of window.
C. Mullions: Match window units.
D. Provide anchors and other related accessories required for installation.
E. Sizes and Profiles: Required sizes and profile requirements are shown on the drawings.
2.5 GLAZING
A. Glass and Glazing: As specified in Section 08 80 00, GLAZING.
1. Factory glaze windows.
2. Weep holes through glazed areas are not acceptable.
2.6 VENETIAN BLINDS
A. Slats: Maximum 25.5 mm (1 inch) wide, tempered aluminum with baked-on acrylic finish. White.
B. Weave Cords and Tapes: Polyester-Dacron fiber.
C. Angle of Slat Tilt: Adjustable from the room side by means of a nonremovable control knob, having cable or gear drive with slip mechanism. Control raising and lowering of blinds by cords or other arrangement, accessible only when the inner sash is opened.
08 51 13.11 - 6
D. Special Security Requirements: Provide removable tool or wand operator to tilt blinds.
2.7 HARDWARE
A. Locks: Two position locking bolts or cam type tamperproof custodial locks with a single point control located not higher than 1500 mm
(60 inches) from floor level. Locate locking devices in vent side rail.
Provide concealed or nonremovable fastenings for locks and keepers.
B. Locking Device Strikes: Locate adjustable strikes in frame jamb.
Fabricate strikes from Type 304 stainless steel
C. Fabricate hinges of noncorrosive metal. Hinges may be either fully concealed when window is closed or semi-concealed with exposed knuckles and hospital tips. Surface mounted hinges are not acceptable.
D. Guide Blocks: Fabricate guide blocks of injection molded nylon. Install guide block fully concealed in vent/frame sill.
E. Hardware for Emergency Ventilation of Windows:
1. Provide windows with hold open linkage.
2. Provide hold open hardware for maximum 150 mm (6 inches) of window opening with adjustable friction shoe to provide resistance when closing window.
3. Handles: Removable type.
F. Hardware for Maintenance Opening of Windows: Opening beyond limit stop position accomplished by maintenance key captured by release device when window is in open position.
1. Design operating device to prevent opening with standard tools, coins or bent wire devices.
G. Hardware for Mental Health Windows:
1. Locks:
a. stainless steel cam locks strike and/or keepers for custodial or supervisory operation to secure sash in closed position.
b. Provide tamper-resistant locks for ventilators at maximum
1020 mm (40 inches) spacing. Prohibit keys from being removed in the unlocked position.
c. Provide a supplemental keyed lock for interior sash ventilators and access panels.
2. Limited Opening Device:
a. Provide concealed device to limit initial sash operation to
152 mm (6 inches). Operation limited past this point to be by use of a tool or removable key.
08 51 13.11 - 7
3. Triple Glazed Access Panel at Sash Ventilators:
a. Access panel to have a custodial hook latch.
H. Weather Stripping: AAMA/WDMA/CSA 101/I.S.2/A440; leaf type weather-stripping is not acceptable.
I. Provide wrenches, keys, or removable locking operating handles, as specified to operate windows.
1. Provide one emergency ventilating operating handle for every four windows.
2. Provide maintenance or window washer operating handles as required.
J. Aluminum Trim:
1. Trim includes casings, closures, and panning.
2. Fabricate to shapes shown, minimum 1.6 mm (0.062 inch) thick.
3. Extruded or formed sections, straight, true, and smooth on exposed surfaces.
4. Exposed external corners mitered and internal corners coped; fitted with hairline joints.
5. Reinforce 1.6 mm (0.062 inch) thick members with minimum 3 mm
(1/8 inch) thick aluminum.
6. Except for strap anchors, provide reinforcing for fastening near ends and spaced maximum 300 mm (12 inches) on center.
7. Design to allow unrestricted expansion and contraction of members and window frames.
8. Secure to window frames with machine screws or expansion rivets.
9. Exposed screws, fasteners or pop rivets are not acceptable on exterior of casing or trim cover system.
K. Aluminum Sub-sills and Stools:
1. Fabricate to shapes shown, minimum 2 mm (0.080 inch) thick extrusion.
2. One-piece full length of opening with concealed anchors.
3. Sills turned up back edge minimum 6 mm (1/4 inch). Front edge provides with drip.
4. Sill back edge behind face of window frame. Do not extend to interior surface or bridge thermal breaks.
5. Do not perforate for anchorage, clip screws, or other requirements.
2.8 FABRICATION
A. Fabricate windows to comply specified performance class and grade.
1. Assemble frame and sash so fasteners are concealed when window is closed.
08 51 13.11 - 8
2. Attach locking and hold-open devices to windows with concealed fasteners.
3. Where extrusion wall thickness is less than 3 mm (0.125 inch) thick, provide backup plates or similar reinforcements for fasteners.
4. Use stainless steel fasteners to secure Venetian blind hanger clips, vent guide blocks, friction adjuster, and limit opening device.
B. Provide baffled weep holes and internal water passages to conduct infiltrating water to the exterior.
C. Miter all corners, internally heat weld or mechanically crimp to reinforcing bar and cement with epoxy adhesive to develop full strength of section, with airtight and watertight joints.
2.9 FINISHES
A. Finish window units according to NAAMM AMP 500 series.
B. Aluminum Paint finish:
1. Fluorocarbon Finish: AAMA 2605; 70 percent fluoropolymer resin, 2-coat system.
2. Color: White.
C. Hardware: Finish hardware exposed when window is in closed position to match window.
2.10 ACCESSORIES
A. Fasteners: AAMA/WDMA/CSA 101/I.S.2/A440; non-magnetic stainless steel.
PART 3 - EXECUTION
3.1 PREPARATION
A. Examine and verify substrate suitability for product installation.
1. Verify openings are within acceptable tolerances.
B. Protect existing construction and completed work from damage.
C. Remove existing windows to permit new installation when replacement window is available, and ready for immediate installation.
1. Remove existing work carefully; avoid damage to existing work indicated to remain.
2. Perform other operations as necessary to prepare openings for proper installation and operation of new windows.
3. Do not leave openings uncovered at end of working day, during precipitation or temperatures below 16 degrees C (60 degrees F).
08 51 13.11 - 9
3.2 INSTALLATION, GENERAL
A. Install products according to manufacturer's instructions and approved submittal drawings.
1. When manufacturer's instructions deviate from specifications, submit proposed resolution for Contracting Officer's Representative consideration.
B. Where type, size or spacing of fastenings for securing window accessories or equipment to building construction is not shown or specified, provide expansion or toggle bolts or screws, as best suited to construction material.
1. Provide bolts or screws minimum 6 mm (1/4 inch) in diameter.
2. Sized and spaced to resist tensile and shear loads imposed.
3. Do not install exposed fasteners on exterior, except when unavoidable for application of hardware.
4. Provide non-magnetic stainless-steel Phillips flat-head machine screws for exposed fasteners, where required, or special tamper-proof fasteners.
5. Locate fasteners to avoid disturbing window thermal break.
C. Set windows plumb, level, true, and in alignment; without warp or rack of frames or sash.
D. Anchor windows on four sides with anchor clips or fin trim.
1. Do not allow anchor clips to bridge thermal breaks.
2. Use separate clips for both sides of thermal breaks.
3. Make connections to allow for thermal and other movements.
4. Do not allow building load to bear on windows.
5. Use manufacturer's standard clips at corners and maximum 600 mm
(24 inches) on center.
6. Where fin trim anchorage is indicated build into adjacent construction, anchoring at corners and maximum 600 mm (24 inches) on center.
E. Sills and Stools:
1. Set in bed of mortar or construction adhesive to fully support, true to line shown.
2. Do not extend sill to inside window surface or past thermal break.
3. Leave space for sealants at ends and to window frame unless indicated otherwise.
08 51 13.11 - 10
3.3 MULLIONS CLOSURES, TRIM, AND PANNING
A. Cut mullion full height of opening and anchor directly to window frame on both sides.
B. Closures, Trim, and Panning: External corners mitered and internal corners coped, fitted with hairline, tightly closed joints.
1. Secure to concrete and solid masonry with expansion bolts, expansion rivets, split shank drive bolts, or powder actuated drive pins.
2. Toggle bolt to hollow masonry units.
3. Screw to wood and metal.
C. Fasten except for strap anchors, near ends and corners and maximum
300 mm (12 inches) on center.
D. Seal units following installation to provide weathertight system.
3.4 ADJUSTING
A. Adjust ventilating sash and hardware to provide tight fit at contact points, and at weather-stripping for smooth operation and weathertight closure.
3.5 FIELD TESTING
A. Field Tests: Performed by testing laboratory specified in Section
01 45 29, TESTING LABORATORY SERVICES.
B. Test Method: AAMA 502.
C. Test Specimen:
1. Include window assembly and construction. Affix test chamber to interior side of test specimen and the conduct testing using positive static air pressure (Test method A).
2. Test specimens to be selected by the Contracting Officer's
Representative after windows have been installed according to the drawings and specification.
3.6 CLEANING
A. Lubricate hardware and moving parts.
B. Remove excess glazing and sealant compounds.
C. Clean exposed aluminum and glass surfaces. Remove contaminants and stains.
D. Keep windows locked except while adjusting and testing.
- - - E N D - - -
10-01-15
08 80 00 - 1
SECTION 08 80 00
GLAZING
PART 1 - GENERAL
1.1 DESCRIPTION:
A. This section specifies the following:
1. Glass.
2. Plastic glazing.
3. Glazing materials and accessories for both factory and field glazed assemblies.
1.2 RELATED WORK:
A. Factory glazed by manufacturer in following units:
1. Aluminum Windows: Section 08 51 13, ALUMINUM WINDOWS.
2. Operable Windows: Section 08 51 13.11, SIDE HINGED ALUMINUM WINDOWS
(Double Glazed).
3. Color of spandrel glass, tinted (heat absorbing or light reducing) glass, and reflective (metallic coated) glass: Section 09 06 00, SCHEDULE FOR FINISHES.
1.3 LABELS:
A. Temporary labels:
1. Provide temporary label on each light of glass identifying manufacturer or brand and glass type, quality and nominal thickness.
2. Label in accordance with NFRC label requirements.
3. Temporary labels are to remain intact until glass is approved by
Contracting Officer Representative (COR).
1.4 PERFORMANCE REQUIREMENTS:
A. General: Design glazing system consistent with guidance and practices presented in the GANA Glazing Manual, GANA Laminated Glazing Manual, and GANA Sealant Manual, as applicable to project. Installed glazing is to withstand applied loads, thermal stresses, thermal movements, building movements, permitted tolerances, and combinations of these conditions without failure, including loss or glass breakage attributable to defective manufacture, fabrication, or installation;
failure of sealants or gaskets to remain watertight and airtight;
deterioration of glazing materials; unsafe engagement of the framing system; deflections beyond specified limits; or other defects in construction.
08 80 00 - 2
B. Glazing Unit Design: Design glass, including engineering analysis meeting requirements of authorities having jurisdiction. Thicknesses listed are minimum. Coordinate thicknesses with framing system manufacturers.
1. Design glass in accordance with ASTM E1300, and for conditions beyond the scope of ASTM E1300, by a properly substantiated structural analysis.
2. Design Wind Pressures: In accordance with ASCE 7.
3. Wind Design Data: In accordance with ASCE 7.
4. Maximum Lateral Deflection: For glass supported on all four edges, limit center-of-glass deflection at design wind pressure to not more than the structural capacity of the glazing unit, the threshold at which frame engagement is no longer safely assured, 1/100 times the short-side length, or 19 mm (0.75 inch), whichever is less.
C. Building Enclosure Vapor Retarder and Air Barrier:
1. Utilize the inner pane of multiple pane sealed units for the continuity of the air barrier and vapor retarder seal.
2. Maintain a continuous air barrier and vapor retarder throughout the glazed assembly from glass pane to heel bead of glazing sealant.
1.5 SUBMITTALS:
A. In accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND
SAMPLES.
B. Manufacturer's Certificates:
1. Certificate on solar heat gain coefficient when value is specified.
3. Certificate on "R" value when value is specified.
C. Manufacturer Warranty.
D. Manufacturer's Literature and Data:
1. Glass, each kind required.
2. Insulating glass units.
3. Transparent (one-way vision glass) mirrors.
4. Elastic compound for metal sash glazing.
5. Putty, for wood sash glazing.
6. Glazing cushion.
7. Sealing compound.
9. Plastic glazing material, each type required.
08 80 00 - 3
D. Samples:
1. Size: 305 mm by 305 mm (12 inches by 12 inches).
2. Tinted glass.
3. Reflective glass.
E. Preconstruction Adhesion and Compatibility Test Report: Submit glazing sealant manufacturer’s test report indicating glazing sealants were tested for adhesion to glass and glazing channel substrates and for compatibility with glass and other glazing materials.
1.6 DELIVERY, STORAGE AND HANDLING: SEE SECTION 08 51 13.11 SIDE-HINGED
ALUMINUM WINDOWS
1.7 WARRANTY:
A. Construction Warranty: Comply with the FAR clause 52.246-21 “Warranty of Construction”.
B. Manufacturer Warranty: Manufacturer shall warranty their glazing from the date of installation and final acceptance by the Government as follows. Submit manufacturer warranty.
1. Insulating glass units to remain sealed for ten (10) years.
1.8 APPLICABLE PUBLICATIONS:
A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only.
B. American Architectural Manufacturers Association (AAMA):
800.....................Test Methods for Sealants
810.1-77................Expanded Cellular Glazing Tape
C. American Society of Civil Engineers (ASCE):
7-10....................Wind Load Provisions
D. ASTM International (ASTM):
C542-05(R2011)..........Lock-Strip Gaskets
C716-06.................Installing Lock-Strip Gaskets and Infill
Glazing Materials
C794-10.................Adhesion-in-Peel of Elastomeric Joint Sealants
C864-05(R2011)..........Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers
C920-14a................Elastomeric Joint Sealants
C964-07(R2012)..........Standard Guide for Lock-Strip Gasket Glazing
C1036-11(R2012).........Flat Glass
C1048-12................Heat-Treated Flat Glass-Kind HS, Kind FT Coated and Uncoated Glass.
08 80 00 - 4
C1172-14................Laminated Architectural Flat Glass
E119-14.................Standard Test Methods for Fire Test of Building
Construction and Material
E1300-12a...............Load Resistance of Glass in Buildings
E1886-13a...............Standard Test Method for Performance of
Exterior Windows, Curtain Walls, Doors, and
Impact Protective Systems Impacted by
Missile(s) and Exposed to Cyclic Pressure
Differentials
E1996-14a...............Standard Specification for Performance of
Exterior Windows, Curtain Walls, Doors, and
Impact Protective Systems Impacted by Windborne
Debris in Hurricanes
E2190-10................Insulating Glass Unit
E2355-10................Test Method for Measuring the Visible Light
Transmission Uniformity of an Absorptive
Electrochromic Coating on a Glazing Surface
E. Code of Federal Regulations (CFR):
16 CFR 1201-10..........Safety Standard for Architectural Glazing
Materials
F. Glass Association of North America (GANA):
2010 Edition............GANA Glazing Manual
2008 Edition............GANA Sealant Manual
2009 Edition............GANA Laminated Glazing Reference Manual
2010 Edition............GANA Protective Glazing Reference Manual
G. International Code Council (ICC):
IBC.....................International Building Code
H. Insulating Glass Certification Council (IGCC)
I. Insulating Glass Manufacturer Alliance (IGMA):
TB-3001-13..............Guidelines for Sloped Glazing
TM-3000.................North American Glazing Guidelines for Sealed
Insulating Glass Units for Commercial and
Residential Use
J. Intertek Testing Services – Warnock Hersey (ITS-WHI)
K. National Fire Protection Association (NFPA):
80-16...................Fire Doors and Windows
252-12..................Fire Tests of Door Assemblies
08 80 00 - 5
257-12..................Standard on Fire Test for Window and Glass
Block Assemblies
L. National Fenestration Rating Council (NFRC)
M. Safety Glazing Certification Council (SGCC) 2012:
Certified Products Directory (Issued Semi-Annually).
N. Underwriters Laboratories, Inc. (UL):
9-08(R2009).............Fire Tests of Window Assemblies
263-14..................Fire Tests of Building Construction and
Materials
752-11..................Bullet-Resisting Equipment.
O. Unified Facilities Criteria (UFC):
4-010-01-03(R2007)......DOD Minimum Antiterrorism Standards for
Buildings
P. U.S. Veterans Administration:
Physical Security Design Manual for VA Facilities (VAPSDG); Life Safety
Protected
Physical Security Design Manual for VA Facilities (VAPSDG); Mission
Critical Facilities
Architectural Design Manual for VA Facilities (VASDM)
Q. Environmental Protection Agency (EPA):
40 CFR 59(2014).........National Volatile Organic Compound Emission
Standards for Consumer and Commercial Products
PART 2 - PRODUCT
2.1 GLASS:
A. Provide minimum thickness stated and as additionally required to meet performance requirements.
1. Provide minimum 6 mm (1/4 inch) thick glass units unless otherwise indicated.
B. Obtain glass units from single source from single manufacturer for each glass type.
C. Clear Glass:
1. ASTM C1036, Type I, Class 1, Quality q3.
D. Tinted Heat reflective and low emissivity coated glass:
1. ASTM C1036, Type I, Class 2, Quality q3.
08 80 00 - 6
2.2 INSULATING GLASS UNITS:
A. Provide factory fabricated, hermetically sealed glass unit consisting of two panes of glass separated by a dehydrated air space and comply with ASTM E2190.
B. Assemble units using glass types specified in Insulating Glass
Schedule.
2.3 GLAZING ACCESSORIES:
A. As required to supplement the accessories provided with the items to be glazed and to provide a complete installation. Ferrous metal accessories exposed in the finished work are to have a finish that will not corrode or stain while in service. Fire rated glazing to be installed with glazing accessories in accordance with the manufacturer’s installation instructions.
B. Setting Blocks: ASTM C864:
1. Silicone type.
2. Channel shape; having 6 mm (1/4 inch) internal depth.
3. Shore A hardness of 80 to 90 Durometer.
4. Block lengths: 50 mm (2 inches) except 100 to 150 mm (4 to 6 inches) for insulating glass.
5. Block width: Approximately 1.6 mm (1/16 inch) less than the full width of the rabbet.
6. Block thickness: Minimum 4.8 mm (3/16 inch). Thickness sized for rabbet depth as required.
C. Spacers: ASTM C864:
1. Channel shape having a 6 mm (1/4 inch) internal depth.
2. Flanges not less 2.4 mm (3/32 inch) thick and web 3 mm (1/8 inch) thick.
3. Lengths: 25 to 76 mm (1 to 3 inches).
4. Shore A hardness of 40 to 50 Durometer.
D. Glazing Tapes:
1. Semi-solid polymeric based closed cell material exhibiting pressure-sensitive adhesion and withstanding exposure to sunlight, moisture, heat, cold, and aging.
2. Shape, size and degree of softness and strength suitable for use in glazing application to prevent water infiltration.
3. Complying with AAMA 800 for the following types:
08 80 00 - 7
a. AAMA 810.1, Type 1, for glazing applications in which tape acts as the primary sealant.
b. AAMA 810.1, Type 2, for glazing applications in which tape is used in combination with a full bead of liquid sealant.
E. Spring Steel Spacer: Galvanized steel wire or strip designed to position glazing in channel or rabbeted sash with stops.
F. Glazing Points (Sprigs): Pure zinc stock, thin, flat, triangular or diamond shaped pieces, 6 mm (1/4 inch) minimum size.
G. Glazing Gaskets: ASTM C864:
1. Firm dense wedge shape for locking in sash.
2. Soft, closed cell with locking key for sash key.
3. Flanges may terminate above the glazing-beads or terminate flush with top of beads.
H. Lock-Strip Glazing Gaskets: ASTM C542, shape, size, and mounting as indicated.
I. Glazing Sealants: ASTM C920, silicone neutral cure:
1. Type S.
2. Class 25 or 50 as recommended by manufacturer for application.
3. Grade NS.
4. Shore A hardness of 25 to 30 Durometer.
J. Structural Sealant: ASTM C920, silicone acetoxy cure:
1. Type S.
2. Class 25.
3. Grade NS.
4. Shore a hardness of 25 to 30 Durometer.
K. Color:
1. Color of glazing compounds, gaskets, and sealants used for aluminum color frames to match color of the finished aluminum and be nonstaining.
2. Color of other glazing compounds, gaskets, and sealants which will be exposed in the finished work and unpainted are to be black, gray, or neutral color.
PART 3 - EXECUTION
3.1 EXAMINATION:
A. Verification of Conditions:
08 80 00 - 8
1. Examine openings for glass and glazing units; determine they are proper size; plumb; square; and level before installation is started.
2. Verify that glazing openings conform with details, dimensions and tolerances indicated on manufacturer is approved shop drawings.
B. Review for conditions which may adversely affect glass and glazing unit installation, prior to commencement of installation. Do not proceed with installation until unsatisfactory conditions have been corrected.
C. Verify that wash down of adjacent masonry is completed prior to erection of glass and glazing units.
3.2 PREPARATION:
A. For sealant glazing, prepare glazing surfaces in accordance with
GANA Sealant Manual.
B. Determine glazing unit size and edge clearances by measuring the actual unit to receive the glazing.
C. Shop fabricate and cut glass with smooth, straight edges of full size required by openings to provide GANA recommended edge clearances.
D. Verify that components used are compatible.
E. Clean and dry glazing surfaces.
F. Prime surfaces scheduled to receive sealants, as determined by preconstruction sealant-substrate testing.
3.3 INSTALLATION – GENERAL:
A. Install in accordance with GANA Glazing Manual, GANA Sealant Manual, IGMA TB-3001, and IGMA TM-3000 unless specified otherwise.
B. Glaze in accordance with recommendations of glazing and framing manufacturers, and as required to meet the Performance Test
Requirements specified in other applicable sections of specifications.
C. Set glazing without bending, twisting, or forcing of units.
D. Do not allow glass to rest on or contact any framing member.
E. Insulating Glass Units:
1. Glaze in compliance with glass manufacturer's written instructions.
2. When glazing gaskets are used, they are to be of sufficient size and depth to cover glass seal or metal channel frame completely.
3. Do not use putty or glazing compounds.
4. Do not grind, nip, cut, or otherwise alter edges and corners of fused glass units after shipping from factory.
5. Install with tape or gunnable sealant in wood sash.
08 80 00 - 9
3.6 INSTALLATION - WET/DRY METHOD (PREFORMED TAPE AND SEALANT)
A. Cut glazing tape to length and set against permanent stops, 5 mm
(3/16 inch) below sight line. Seal corners by butting tape and dabbing with butyl sealant.
B. Apply heel bead of butyl sealant along intersection of permanent stop with frame ensuring full perimeter seal between glass and frame to complete the continuity of the air and vapor seal.
C. Place setting blocks at 1/3 points with edge block no more than 152 mm
(6 inches) from corners.
D. Rest glazing on setting blocks and push against tape and heel bead of sealant with sufficient pressure to achieve full contact at perimeter of pane or glass unit.
E. Install removable stops, with spacer strips inserted between glazing and applied stops, 6 mm (1/4 inch) below sight line. Place glazing tape on glazing pane or unit with tape flush with sight line.
F. Fill gap between glazing and stop with sealant to depth equal to bite of frame on glazing, but not more than 9 mm (3/8 inch) below sight line. Sealant type is to be compatible with glazing tape.
G. Apply cap bead of sealant along void between the stop and the glazing, to uniform line, flush with sight line. Tool or wipe sealant surface smooth.
3.7 REPLACEMENT AND CLEANING:
A. Clean new glass surfaces removing temporary labels, paint spots, and defacement after approval by COR.
B. Replace cracked, broken, and imperfect glass, or glass which has been installed improperly.
C. Leave glass, putty, and other setting material in clean, whole, and acceptable condition.
3.8 PROTECTION:
A. Protect finished surfaces from damage during erection, and after completion of work. Strippable plastic coatings on colored anodized finish are not acceptable.
3.9 INSULATING GLASS SCHEDULE:
A. Glass Type: Clear insulating glass.
1. Overall Unit Thickness: 1 inch.
2. Minimum Thickness of Each Glass Lite: 6 mm (0.23 inch).
08 80 00 - 10
3. Outdoor Lite: Annealed float glass, except heat-strengthened float glass where required, and fully tempered float glass where indicated.
4. Interspace Content: Argon.
5. Indoor Lite: Fully tempered float glass.
6. Visible Light Transmittance: 80 percent minimum.
7. Solar Heat Gain Coefficient: 0.75 maximum.
8. Safety glazing label required.
B. Glass Type: Low-E-coated, clear insulating glass.
1. Overall Unit Thickness: 1 inch.
2. Minimum Thickness of Each Glass Lite: 6 mm (0.23 inch).
3. Outdoor Lite: Annealed float glass, except heat-strengthened float glass where required, and fully tempered float glass where indicated.
4. Interspace Content: Argon.
5. Indoor Lite: Fully tempered float glass.
6. Low-E Coating: Sputtered on second surface.
7. Visible Light Transmittance: 68 percent minimum.
8. Solar Heat Gain Coefficient: 0.38 maximum.
C. Glass Type: Reflective-coated, low-E coated insulating glass.
1. Overall Unit Thickness: 25 mm (1 inch).
2. Minimum Thickness of Each Glass Lite: 6 mm (0.23 inch).
3. Outdoor Lite: Annealed float glass, except heat-strengthened float glass where required, and fully tempered float glass where indicated.
a. Tint Color: Gray.
b. Reflective Coating Type: Sputter-coating (vacuum deposition process).
1) Coating Color: Silver.
2) Coating Location: Second surface.
4. Interspace Content: Argon.
5. Indoor Lite: Fully tempered float glass.
6. Low-E Coating: Sputtered on second surface.
7. Outdoor Visible Reflectance: 68 percent maximum.
8. Visible Light Transmittance: 68 percent minimum.
08 80 00 - 11
9. Solar Heat Gain Coefficient: 0.38 maximum.
- - - E N D - - -
| PART 1 - GENERAL |
| 1.1 SUMMARY |
| A. Section Includes: |
| 1. Side hinged, in-swing casement type windows renovation work. |
| 2. Enclosed venetian blinds. |
| 3. Window hardware and accessories. |
| 1.2 RELATED REQUIREMENTS |
| A. Sealing Joints: Section 07 92 00, JOINT SEALANTS. |
| B. Glazing: Section 08 80 00, GLAZING. |
| C. Window Color: White. |
| 1.3 APPLICABLE PUBLICATIONS |
| A. Comply with references to extent specified in this section. |
| B. American Architectural Manufacturers Associations (AAMA): |
| 1. AAMA/WDMA/CSA 101/I.S.2/A440-11 - Windows, Doors, and Skylights. |
| 2. 502-12 - Field Testing of Newly Installed Fenestration Products. |
| 3. 505-09 - Dry Shrinkage and Composite Performance Thermal Cycling Test Procedures. |
| 4. 2605-13 - Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels. |
| 5. TIR A8-08 - Structural Performance of Composite Thermal Barrier Framing System. |
| C. American Society of Civil Engineers/Structural Engineering Institute (ASCE/SEI): |
| 1. 7-10 - Minimum Design Loads for Buildings and Other Structures. |
| D. American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE): |
| 1. 90.1-13 - Energy Standard for Buildings Except Low Rise Residential Buildings. |
| E. ASTM International (ASTM): |
| 1. B209-14 - Aluminum and Aluminum-Alloy Sheet and Plate. |
| 2. B209M-14 - Aluminum and Aluminum-Alloy Sheet and Plate (Metric). |
| 3. B221-14 - Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes. |
| 4. B221M 13 - Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, E283-04(2012) - Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. |
| 5. E331-00(2009) - Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference. |
| F. National Association of Architectural Metal Manufacturers (NAAMM): |
| 1. AMP 500 Series - Metal Finishes Manual. |
| 1.4 PRE-INSTALLATION MEETINGS |
| A. Conduct pre-installation meeting at project site minimum 30 days before beginning Work of this section. |
| 1. Required Participants: |
| a. Contracting Officer's Representative. |
| b. Architect/Engineer. |
| c. Inspection and Testing Agency. |
| d. Contractor. |
| e. Installer. |
| f. Manufacturer's field representative. |
| g. Other installers responsible for adjacent and intersecting work, including weather barrier installer. |
| 2. Meeting Agenda: Distribute agenda to participants minimum 3 days before meeting. |
| a. Installation schedule. |
| b. Installation sequence. |
| c. Preparatory work. |
| d. Protection before, during, and after installation. |
| e. Installation. |
| f. Terminations. |
| g. Transitions and connections to other work. |
| h. Inspecting and testing. |
| i. Other items affecting successful completion. |
3. Document and distribute meeting minutes to participants to record decisions affecting installation.
| 1.5 SUBMITTALS |
| A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. |
| B. Submittal Drawings: |
| 1. Show size, configuration, and fabrication and installation details. |
| 2. Details of metal trim, including anchorages. |
| 3. Include glazing details and standards for factory glazed units. |
| C. Manufacturer's Literature and Data: |
| 1. Description of each product. |
| 2. Installation instructions. |
| 3. Warranty. |
| D. Samples: (Not Used) |
| E. Test reports: Certify each product complies with specifications. |
| 1. Windows. |
| 2. Operating hardware. |
| F. Certificates: Certify each product complies with specifications. |
| 1. Windows. |
| a. Architectural Aluminum Manufacturer Association, “AAMA label” affixed to each window indicating compliance with specification. |
| b. Certificates in lieu of label with copy of recent test report (maximum four years old) from an independent testing laboratory and certificate signed by window manufacturer stating that windows provided comply with specified requirements and AAMA/WD... |
| G. Operation and Maintenance Data: |
| 1. Care instructions for each exposed finish product. |
| 1.6 QUALITY ASSURANCE |
| A. Manufacturer Qualifications: |
| 1. Regularly manufactures specified products. |
| 2. Manufactured specified products with satisfactory service on five similar installations for minimum five years. |
| a. Provide contact names and addresses for completed projects when requested by Contracting Officer's Representative. |
| B. Quality Certified Labels or Certificates: |
| 1. AAMA Label affixed to each window indicating compliance with specification. |
| 2. Certificates in lieu of label with copy of test report maximum 4 years old from independent testing laboratory and certificate signed by window manufacturer stating that windows provided comply with specified requirements and AAMA/WDMA/CSA 101/I.S.... |
| 1.7 DELIVERY |
| A. Deliver products in manufacturer's original sealed packaging. |
| B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, production run number, and manufacture date. |
| C. Before installation, return or dispose of products within distorted, damaged, or opened packaging. |
| 1.8 STORAGE AND HANDLING |
| A. Protect windows from damage during handling and construction operations before, during and after installation. |
| B. Store windows under cover, setting upright. |
| C. Do not stack windows flat. |
| D. Do not lay building materials or equipment on windows. |
| 1.9 WARRANTY |
| A. Construction Warranty: FAR clause 52.246-21, "Warranty of Construction." |
| 1. Warranty Period: 1 year from completion. |
| B. Manufacturer's Warranty: Warrant windows against material and manufacturing defects. |
| 1. Warranty Period: 10 years. |
| PART 2 - PRODUCTS |
| 2.1 SYSTEM PERFORMANCE |
| A. Design windows complying with specified performance: |
| 1. Load Resistance: ASCE/SEI 7. |
| a. Performance Grade: AAMA/WDMA/CSA 101/I.S.2/A440 required to resist maximum positive and negative wind load. |
| 2. Thermal Transmittance: Maximum U-value W/sq. m/degree K (Btu/sq. ft./hr./degree F). |
| a. Insulating Glass Windows: U-2.8 (U-0.5). |
| b. Triple Glazed Windows: U-4.0 (U-0.7), or as required by ASHRAE 90.1. |
| 3. Condensation Resistance Factor (CRF): NFRC 500 Minimum CRF of 45. |
| 4. Water Resistance: ASTM E331; No uncontrolled penetration at 220 Pa (4.50 psf), minimum, pressure differential. |
| 5. Air Infiltration Resistance: ASTM E283; 1.5 L/s/sq. m (0.3 cfm/sq. ft.), maximum at 75 Pa (1.57 psf), minimum, pressure differential. |
| 6. Performance Class and Grade: AAMA/WDMA/CSA 101/I.S.2/A440, minimum AW-40. |
| 2.2 MATERIALS |
| A. Aluminum Extrusions: ASTM B221M (ASTM B221); 6063 alloy, T5 temper. |
| B. Aluminum Sheet: ASTM B209M (ASTM B209); 5005 alloy, H15 or H34 temper. |
| 2.3 PRODUCTS - GENERAL |
| A. Basis of Design: Peerless Product Inc. |
| B. Provide windows from one manufacturer (Peerless Product Inc). |
| C. Sustainable Construction Requirements: |
| 1. Aluminum Recycled Content: 80 total recycled content, minimum. |
| 2.4 ALUMINUM WINDOWS |
| A. Frames and Sashes: Aluminum extrusions, AAMA/WDMA/CSA 101/I.S.2/A440. |
| B. Thermal-Break Window Construction: |
| 1. Manufacturer’s Standard. |
| 2. Low conductance thermal barrier. |
| 3. Capable of structurally holding sash in position and together. |
| 4. Thermal Break Assemblies: Tested according to AAMA TIR A8 and AAMA 505. |
| 5. Design location of thermal break so that, in closed position, outside air does not come in direct contact with interior frame of window. |
| C. Mullions: Match window units. |
| D. Provide anchors and other related accessories required for installation. |
| E. Sizes and Profiles: Required sizes and profile requirements are shown on the drawings. |
| 2.5 GLAZING |
| A. Glass and Glazing: As specified in Section 08 80 00, GLAZING. |
| 1. Factory glaze windows. |
| 2. Weep holes through glazed areas are not acceptable. |
| 2.6 VENETIAN BLINDS |
| A. Slats: Maximum 25.5 mm (1 inch) wide, tempered aluminum with baked-on acrylic finish. White. |
| B. Weave Cords and Tapes: Polyester-Dacron fiber. |
| C. Angle of Slat Tilt: Adjustable from the room side by means of a nonremovable control knob, having cable or gear drive with slip mechanism. Control raising and lowering of blinds by cords or other arrangement, accessible only when the inner sash is ... |
| D. Special Security Requirements: Provide removable tool or wand operator to tilt blinds. |
| 2.7 HARDWARE |
| A. Locks: Two position locking bolts or cam type tamperproof custodial locks with a single point control located not higher than 1500 mm (60 inches) from floor level. Locate locking devices in vent side rail. Provide concealed or nonremovable fastenin... |
| B. Locking Device Strikes: Locate adjustable strikes in frame jamb. Fabricate strikes from Type 304 stainless steel |
| C. Fabricate hinges of noncorrosive metal. Hinges may be either fully concealed when window is closed or semi-concealed with exposed knuckles and hospital tips. Surface mounted hinges are not acceptable. |
| D. Guide Blocks: Fabricate guide blocks of injection molded nylon. Install guide block fully concealed in vent/frame sill. |
| E. Hardware for Emergency Ventilation of Windows: |
| 1. Provide windows with hold open linkage. |
| 2. Provide hold open hardware for maximum 150 mm (6 inches) of window opening with adjustable friction shoe to provide resistance when closing window. |
| 3. Handles: Removable type. |
| F. Hardware for Maintenance Opening of Windows: Opening beyond limit stop position accomplished by maintenance key captured by release device when window is in open position. |
| 1. Design operating device to prevent opening with standard tools, coins or bent wire devices. |
| G. Hardware for Mental Health Windows: |
| 1. Locks: |
| a. stainless steel cam locks strike and/or keepers for custodial or supervisory operation to secure sash in closed position. |
| b. Provide tamper-resistant locks for ventilators at maximum 1020 mm (40 inches) spacing. Prohibit keys from being removed in the unlocked position. |
| c. Provide a supplemental keyed lock for interior sash ventilators and access panels. |
| 2. Limited Opening Device: |
| a. Provide concealed device to limit initial sash operation to 152 mm (6 inches). Operation limited past this point to be by use of a tool or removable key. |
| 3. Triple Glazed Access Panel at Sash Ventilators: |
| a. Access panel to have a custodial hook latch. |
| H. Weather Stripping: AAMA/WDMA/CSA 101/I.S.2/A440; leaf type weather-stripping is not acceptable. |
| I. Provide wrenches, keys, or removable locking operating handles, as specified to operate windows. |
| 1. Provide one emergency ventilating operating handle for every four windows. |
| 2. Provide maintenance or window washer operating handles as required. |
| J. Aluminum Trim: |
| 1. Trim includes casings, closures, and panning. |
| 2. Fabricate to shapes shown, minimum 1.6 mm (0.062 inch) thick. |
| 3. Extruded or formed sections, straight, true, and smooth on exposed surfaces. |
| 4. Exposed external corners mitered and internal corners coped; fitted with hairline joints. |
| 5. Reinforce 1.6 mm (0.062 inch) thick members with minimum 3 mm (1/8 inch) thick aluminum. |
| 6. Except for strap anchors, provide reinforcing for fastening near ends and spaced maximum 300 mm (12 inches) on center. |
| 7. Design to allow unrestricted expansion and contraction of members and window frames. |
| 8. Secure to window frames with machine screws or expansion rivets. |
| 9. Exposed screws, fasteners or pop rivets are not acceptable on exterior of casing or trim cover system. |
| K. Aluminum Sub-sills and Stools: |
| 1. Fabricate to shapes shown, minimum 2 mm (0.080 inch) thick extrusion. |
| 2. One-piece full length of opening with concealed anchors. |
| 3. Sills turned up back edge minimum 6 mm (1/4 inch). Front edge provides with drip. |
| 4. Sill back edge behind face of window frame. Do not extend to interior surface or bridge thermal breaks. |
| 5. Do not perforate for anchorage, clip screws, or other requirements. |
| 2.8 FABRICATION |
| A. Fabricate windows to comply specified performance class and grade. |
| 1. Assemble frame and sash so fasteners are concealed when window is closed. |
| 2. Attach locking and hold-open devices to windows with concealed fasteners. |
| 3. Where extrusion wall thickness is less than 3 mm (0.125 inch) thick, provide backup plates or similar reinforcements for fasteners. |
| 4. Use stainless steel fasteners to secure Venetian blind hanger clips, vent guide blocks, friction adjuster, and limit opening device. |
| B. Provide baffled weep holes and internal water passages to conduct infiltrating water to the exterior. |
| C. Miter all corners, internally heat weld or mechanically crimp to reinforcing bar and cement with epoxy adhesive to develop full strength of section, with airtight and watertight joints. |
| 2.9 FINISHES |
| A. Finish window units according to NAAMM AMP 500 series. |
| B. Aluminum Paint finish: |
| 1. Fluorocarbon Finish: AAMA 2605; 70 percent fluoropolymer resin, 2-coat system. |
| 2. Color: White. |
C. Hardware: Finish hardware exposed when window is in closed position to match window.
| 2.10 ACCESSORIES |
| A. Fasteners: AAMA/WDMA/CSA 101/I.S.2/A440; non-magnetic stainless steel. |
| PART 3 - EXECUTION |
| 3.1 PREPARATION |
| A. Examine and verify substrate suitability for product installation. |
| 1. Verify openings are within acceptable tolerances. |
| B. Protect existing construction and completed work from damage. |
| C. Remove existing windows to permit new installation when replacement window is available, and ready for immediate installation. |
| 1. Remove existing work carefully; avoid damage to existing work indicated to remain. |
| 2. Perform other operations as necessary to prepare openings for proper installation and operation of new windows. |
| 3. Do not leave openings uncovered at end of working day, during precipitation or temperatures below 16 degrees C (60 degrees F). |
| 3.3 MULLIONS CLOSURES, TRIM, AND PANNING |
| A. Cut mullion full height of opening and anchor directly to window frame on both sides. |
| B. Closures, Trim, and Panning: External corners mitered and internal corners coped, fitted with hairline, tightly closed joints. |
| 1. Secure to concrete and solid masonry with expansion bolts, expansion rivets, split shank drive bolts, or powder actuated drive pins. |
| 2. Toggle bolt to hollow masonry units. |
| 3. Screw to wood and metal. |
| C. Fasten except for strap anchors, near ends and corners and maximum 300 mm (12 inches) on center. |
| D. Seal units following installation to provide weathertight system. |
| 3.4 ADJUSTING |
| A. Adjust ventilating sash and hardware to provide tight fit at contact points, and at weather-stripping for smooth operation and weathertight closure. |
| 3.5 FIELD TESTING |
| A. Field Tests: Performed by testing laboratory specified in Section 01 45 29, TESTING LABORATORY SERVICES. |
| B. Test Method: AAMA 502. |
| C. Test Specimen: |
| 1. Include window assembly and construction. Affix test chamber to interior side of test specimen and the conduct testing using positive static air pressure (Test method A). |
| 2. Test specimens to be selected by the Contracting Officer's Representative after windows have been installed according to the drawings and specification. |
| 3.6 CLEANING |
| A. Lubricate hardware and moving parts. |
| B. Remove excess glazing and sealant compounds. |
| C. Clean exposed aluminum and glass surfaces. Remove contaminants and stains. |
| D. Keep windows locked except while adjusting and testing. |
File details come from the government source that posted it.