36C24421B0019_1.docx
DOCX document 32 KB Posted
- Attached to
- Z1DZ--693-21-108 Prep Work for Storage Drying Cabinets Federal contract opportunity
- Solicitation number
- 36C24421B0019
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 5th Floor Mech Room Layout.pdf | ||
| 36C24421B0019 0001_1.docx | DOCX document | |
| S02 SafetyHealthDuringConstruction 18S-15-346.pdf | ||
| EndoDryCabinets8x11SingleFinal.pdf | ||
| S02 Sol 36C24421B0019.docx | DOCX document | |
| EndoDryRequirements.pdf | ||
| SPSRoomLayout.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
36C24421B0019
| SUBJECT* |
| 693-21-108 Prep Work for Storage Drying Cabinets |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 18711 |
| SOLICITATION NUMBER* |
| 36C24421B0019 |
| RESPONSE DATE/TIME/ZONE |
| 10-07-2021 4:00 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 90 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| Z1DZ |
| NAICS CODE* |
| 236220 |
| CONTRACTING OFFICE ADDRESS |
| Department of Veterans Affairs |
Network Contracting Office 4 Wilkes-Barre VAMC Acquisitions (049E) 1111 East End Blvd Wilkes-Barre PA 18711
POINT OF CONTACT*
Scot Plank Scot B Plank Scot.Plank@va.gov 570-824-3521
PLACE OF PERFORMANCE
| ADDRESS |
| Department of Veterans Affairs |
Wilkes-Barre VA Medical Center
1111 East End Blvd
Wilkes-Barre PA
18711
POSTAL CODE
| COUNTRY |
| USA |
ADDITIONAL INFORMATION
AGENCY’S URL
URL DESCRIPTION
| AGENCY CONTACT’S EMAIL ADDRESS |
| scot.plank@va.gov |
EMAIL DESCRIPTION
Combined Synopsis/Solicitation Notice
Combined Synopsis/Solicitation Notice
DESCRIPTION
Combined Synopsis/Solicitation Notice
Combined Synopsis/Solicitation Notice
STATEMENT OF WORK
PREP WORK FOR STORAGE DRYING SYSTEM
PROJECT# 693-21-108
1. General:
a. The scope of work shall generally consist of, but not necessarily be limited to, providing all labor, materials, tools, equipment, permits, testing, and reports required to complete site prep for the installation of Endodry Storage and Drying System in Room N4-107 in the Sterile Processing area on the 4th floor of the Wilkes-Barre VA Medical Facility. Any work determined by the COR as having a significant impact on the daily operations of the facility shall be conducted on an after-hours schedule. All work shall be performed in accordance with VA Master Specifications. All federal, state, and local code/regulations/standards shall be followed.
b. The Endodry Storage and Drying System is a system that is already purchased by the VA. This project is for site prep only. The Endodry Storage and Drying System will be provided and installed by the manufacturer under a separate contract after site prep is completed. The scope of work does not require the contractor to install or handle the Endodry Storage and Drying System.
c. The work will consist of installing a medical grade compressed air system to provide the required compressed air for the storage and drying system. The compressors for the compressed air system shall be installed in the 5th Floor Mechanical Room C5-81. The compressed air shall meet quality standards of ISO 8573-1:2010 class 1.2.1.
· Particle Size: Incoming air filtered down to <1 micron in size
· Moisture Content: Pressure dew point of -40⁰C or better required and no liquid water.
· Oil Content: < 0.01 mg of oil per cubic meter of compressed air (liquid, aerosol, or vapor oil
d. For preparation within Room N4-99, there are electrical outlets and air outlets required. There shall be a total of 6 GFI/RCD protected electrical outlets and 6 air quick disconnects installed on the walls above each cabinet at a minimum height of 78.7 inches off the floor.
e. The compressed air system shall be capable of providing air to all 6 cabinets simultaneously and have a N+1 redundancy. Each cabinet has a minimum requirement of 7 scfm to operate. The manufacturer’s recommended compressors are BeaconMedaes LES20-145RD or Powerex LSE2005. Substitutes are permitted but contractor shall be responsible for confirming any substitutes meet the requirements for quality and quantity. All work on compressed air system shall be performed by ASSE certified installers. Before system is placed in service, the fully functioning system shall be inspected and certified.
f. The above scope of work is intended to describe the project in general. The contractor shall abide by all Infection Control Risk Assessment (ICRA) guidelines when performing this project.
g. The contractor shall follow all federal, state, and local codes, regulations, and standards, and all work shall be performed during normal business hours 7:00AM to 4:30PM Monday to Friday excluding national holidays. The work shall be coordinated through the designated Contracting Officer’s Representative (COR).
2. Electrical:
a. The contractor shall supply materials and labor for power connections needed for the compressors selected.
b. The contractor shall supply materials and labor for duplex electrical connections for each cabinet.
See attached document: S02 Sol 36C24421B0019.
See attached document: S02 SafetyHealthDuringConstruction 18S-15-346.
See attached document: SPSRoomLayout.
See attached document: EndoDryRequirements.
See attached document: EndoDryCabinets8x11SingleFinal.
End of Document