36C24419B0001-014.pdf

PDF 34 KB Posted

Attached to
693-18-106 - Replace Roof Bldg #6 Federal contract opportunity
Solicitation number
36C24419B0001
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

About this file

36C24419B0001 S02 Glazing Specs 36C24419B0001.pdf

View the file

Other files for this federal contract opportunity

Other files attached to 693-18-106 - Replace Roof Bldg #6, newest first.
File Type Posted
36C24419C0170-000.docx DOCX document
36C24419B0001-0002000.docx DOCX document
36C24419B0001-0001001.pdf PDF
36C24419B0001-0001003.pdf PDF
36C24419B0001-0001000.docx DOCX document
36C24419B0001-0001002.pdf PDF
36C24419B0001-013.docx DOCX document
36C24419B0001-015.pdf PDF
36C24419B0001-017.pdf PDF
36C24419B0001-016.pdf PDF
36C24419B0001-018.docx DOCX document
36C24419B0001-000.docx DOCX document
36C24419B0001-000.docx DOCX document
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 08 80 00

GLAZING

Wilkes-Barre VAMC Wilkes Barre, PA 18711

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies glass, plastic, related glazing materials and accessories. Glazing products specified apply to factory or field glazed items.

1.2 RELATED WORK

A. Factory glazed by manufacturer in following units:

1. Section 08 51 13, ALUMINUM WINDOWS

2. Section 08 44 13, GLAZED ALUMINUM CURTAIN WALLS.

1.3 LABELS

A. Temporary labels:

1. Provide temporary label on each light of glass identifying manufacturer or brand and glass type, quality and nominal thickness.

2. Label in accordance with NFRC (National Fenestration Rating Council) label requirements.

3. Temporary labels shall remain intact until glass approved by

Contracting Officer Representative (COR).

B. Permanent labels:

1. Locate in corner for each pane.

2. Label in accordance with ANSI Z97.1 and SGCC (Safety Glass

Certification Council) label requirements.

a. Tempered glass.

b. Laminated glass or have certificate for panes without permanent label.

c. Organic coated glass.

1.4 PERFORMANCE REQUIREMENTS

A. Glass Thickness:

1. Select thickness of exterior glass to withstand dead loads and wind loads acting normal to plane of glass at design pressures calculated in accordance with ASCE 7 applicable code.

2. Test in accordance with ASTM E 1300.

3. Thicknesses listed are minimum. Coordinate thicknesses with framing system manufacturers.

08 80 00-2

1.5 SUBMITTALS

A. In accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND

SAMPLES.

B. Manufacturer's Certificates:

1. Certificate on shading coefficient.

2. Certificate on "R" value when value is specified.

C. Warranty: Submit written guaranty, conforming to General Condition requirements, and to “Warranty of Construction” Article in this

Section.

D. Manufacturer's Literature and Data:

1. Glass, each kind required.

2. Insulating glass units.

3. Elastic compound for metal sash glazing.

4. Putty, for wood sash glazing.

5. Glazing cushion.

6. Sealing compound.

E. Samples:

1. Size: 150 mm by 150 mm (6 inches by 6 inches).

2. Tinted glass.

3. Reflective glass.

F. Preconstruction Adhesion and Compatibility Test Report: Submit glazing sealant manufacturer’s test report indicating glazing sealants were tested for adhesion to glass and glazing channel substrates and for compatibility with glass and other glazing materials.

1.6 DELIVERY, STORAGE AND HANDLING

A. Delivery: Schedule delivery to coincide with glazing schedules so minimum handling of crates is required. Do not open crates except as required for inspection for shipping damage.

B. Storage: Store cases according to printed instructions on case, in areas least subject to traffic or falling objects. Keep storage area clean and dry.

C. Handling: Unpack cases following printed instructions on case. Stack individual windows on edge leaned slightly against upright supports with separators between each.

D. Protect laminated security glazing units against face and edge damage during entire sequence of fabrication, handling, and delivery to installation location. Provide protective covering on exposed faces of

08 80 00-3 glazing plastics, and mark inside as "INTERIOR FACE" or "PROTECTED

FACE":

1. Protect sealed-air-space insulating glazing units from exposure to abnormal pressure changes, as could result from substantial changes in altitude during delivery by air freight. Provide temporary breather tubes which do not nullify applicable warranties on hermetic seals.

2. Temporary protections: The glass front and polycarbonate back of glazing shall be temporarily protected with compatible, peelable, heat-resistant film which shall be peeled for inspections and re-applied and finally removed after doors and windows are installed at destination. Since many adhesives shall attack polycarbonate, the film used on exposed polycarbonate surfaces shall be approved and applied by manufacturer.

3. Edge protection: To cushion and protect glass clad, polycarbonate, and Noviflex edges from contamination or foreign matter, the four edges shall be sealed the depth of glazing with continuous standard-thickness Santoprene tape. Alternatively, continuous channel shaped extrusion of Santoprene shall be used, with flanges extending into face sides of glazing.

4. Protect "Constant Temperature" units including every unit where glass sheet is directly laminated to or directly sealed with metal-tube type spacer bar to polycarbonate sheet, from exposures to ambient temperatures outside the range of 16 to 24 C, during the fabricating, handling, shipping, storing, installation, and subsequent protection of glazing.

1.7 PROJECT CONDITIONS

A. Field Measurements: Field measure openings before ordering tempered glass products. Be responsible for proper fit of field measured products.

1.8 WARRANTY

A. Warranty: Conform to terms of "Warranty of Construction", FAR clause

52.246-21, except extend warranty period for the following:

1. Insulating glass units to remain sealed for 10 years.

2. Laminated glass units to remain laminated for 5 years.

08 80 00-4

1.9 APPLICABLE PUBLICATIONS

A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only.

B. American National Standards Institute (ANSI):

Z97.1-09................Safety Glazing Material Used in

Building - Safety Performance Specifications and Methods of Test.

C. American Society for Testing and Materials (ASTM):

C542-05.................Lock-Strip Gaskets

C716-06.................Installing Lock-Strip Gaskets and Infill

Glazing Materials.

C794-10.................Adhesion-in-Peel of Elastomeric Joint Sealants

C864-05.................Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers

C920-11.................Elastomeric Joint Sealants

C964-07.................Standard Guide for Lock-Strip Gasket Glazing

C1036-06................Flat Glass

C1048-12................Heat-Treated Flat Glass-Kind HS, Kind FT Coated and Uncoated Glass.

C1376-10................Pyrolytic and Vacuum Deposition Coatings on

Flat Glass

D635-10.................Rate of Burning and/or Extent and Time of

Burning of Self-Supporting Plastic in a

Horizontal Position

D4802-10................Poly (Methyl Methacrylate) Acrylic Plastic

Sheet

E84-10..................Surface Burning Characteristics of Building

Materials

E119-10.................Standard Test Methods for Fire Test of Building

Construction and Material

E2190-10................Insulating Glass Unit

D. Commercial Item Description (CID):

A-A-59502...............Plastic Sheet, Polycarbonate

E. Code of Federal Regulations (CFR):

16 CFR 1201 - Safety Standard for Architectural Glazing Materials; 2010

F. National Fire Protection Association (NFPA):

08 80 00-5

80-13...................Fire Doors and Windows.

252-12..................Standard Method of Fire Test of Door Assemblies

257-12..................Standard on Fire Test for Window and Glass

Block Assemblies

G. National Fenestration Rating Council (NFRC)

H. Safety Glazing Certification Council (SGCC) 2012:

Certified Products Directory (Issued Semi-Annually).

I. Underwriters Laboratories, Inc. (UL):

752-11..................Bullet-Resisting Equipment.

J. Unified Facilities Criteria (UFC):

4-010-01-2012...........DOD Minimum Antiterrorism Standards for

Buildings

K. Glass Association of North America (GANA):

Glazing Manual (Latest Edition)

Sealant Manual (2009)

L. American Society of Civil Engineers (ASCE):

ASCE 7-10...............Wind Load Provisions

PART 2 - PRODUCT

2.1 GLASS

A. Use thickness stated unless specified otherwise in assemblies.

B. Clear Glass:

1. ASTM C1036, Type I, Class 1, Quality q3

2. Thickness, 6 mm (1/4 inch) unless indicated otherwise on drawings.

C. Tinted Heat reflective and low emissivity coated glass:

1. ASTM C1036, Type I, Class 2, Quality q3.

2. Color: Viracon VNE-63 or equal.

3. Thickness, 6 mm (1/4 inch) unless indicated otherwise on drawings.

2.2 HEAT-TREATED GLASS

A. Clear Tempered Glass:

1. ASTM C1048, Kind FT, Condition A, Type I, Class 1, Quality q3.

2. Thickness, 6 mm (1/4 inch) unless indicated otherwise on drawings.

2.3 COATED GLASS

A. Spandrel Glass:

1. ASTM C1048, Kind HS, Condition B, Type I.

2. Thickness, 6 mm (1/4 inch) unless indicated otherwise on drawings.

B. Low-E Tempered Glass:

1. ASTM C1048, Kind FT, Condition C, Type I, Class 1, Quality q3 with low emissivity pyrolytic coating having an E of 0.15.

08 80 00-6

2. Apply coating to second surface of insulating glass units.

3. Thickness, 4.8 mm (1/4 inch) unless indicated otherwise on drawings.

2.4 LAMINATED GLASS

A. Two or more lites of glass bonded with an interlayer material for use in building glazing

B. Use 1.5 mm (0.060 inch) thick interlayer for:

1. Horizontal or Sloped glazing.

2. Heat strengthened or fully tempered glass assembles.

C. Use min. 0.75 mm (0.030 inch) thick interlayer for vertical glazing where 1.5 mm (0.060 inch) interlayer is not otherwise shown or required.

2.5 LAMINATED GLAZING ASSEMBLIES

A. Clear Glazing:

1. Both panes clear glass ASTM C1036, Type I, Class 1, Quality q3.

2. Thickness: Each pane, 3 mm (1/8 inch) thick.

B. Clear Tempered Glazing:

1. Both panes ASTM C1048, Kind FT, Condition A, Type I, Class 1, Quality q3.

2. Thickness: Each pane 4.8 mm (3/16 inch).

2.6 INSULATING GLASS UNITS

A. Provide factory fabricated, hermetically sealed glass unit consisting of two panes of glass separated by a dehydrated air space and comply with ASTM E2190.

B. Assemble units using glass types specified:

C. Sealed Edge Units (SEU):

1. Triple Glazed Insulating Glass Unit Makeup

a. Outboard Lite

1. Glass type: Low-E Tempered Glass

2. Glass Tint: Viracon VNE-63 or equal

3. Nominal Thickness: 1/4”

4. Glass Strength: Annealed

5. Coating Orientation: Surface #2

b. Outboard Spacer

1. Nominal Thickness: 1/2”

2. Gas Fill: 90% Argon

c. Center Lite

1. Glass Type: Clear Glass

08 80 00-7

2. Glass Tint: none

3. Nominal Thickness: 1/4”

4. Glass Strength: Annealed

5. Coating Orientation: N/A

d. Inboard Spacer

1. Nominal Thickness: 1/2”

2. Gas Fill: 90% Argon

e. Inboard Lite

1. Glass Type: Clear Glass

2. Glass Tint: none

3. Nominal Thickness: 1/4”

4. Glass Strength: Annealed

5. Coating Orientation: N/A,

2. Triple Glazed Insulating Glass Unit Performance Characteristics

(Center of Glass)

a. Visible Transmittance: 55%

b. Visible Reflectance (Exterior): 13%

c. Winter U-factor (U-value): 0.18

d. Shading Coefficient (SC): 0.30

e. Solar heat Gain Coefficient (SHGC): 0.26

3. Glass shall be annealed, heat strengthened or tempered as required by codes, or as required to meet thermal stress and wind loads.

4. Glass heat-treated by horizontal (roller hearth) process with inherent roller wave distortion parallel to the bottom edge of the glass as installed when specified.

2.7 GLAZING ACCESSORIES

A. As required to supplement the accessories provided with the items to be glazed and to provide a complete installation. Ferrous metal accessories exposed in the finished work shall have a finish that shall not corrode or stain while in service.

B. Setting Blocks: ASTM C864:

1. Channel shape; having 6 mm (1/4 inch) internal depth.

2. Shore a hardness of 80 to 90 Durometer.

3. Block lengths: 50 mm (two inches) except 100 to 150 mm (four to six inches) for insulating glass.

4. Block width: Approximately 1.6 mm (1/16 inch) less than the full width of the rabbet.

08 80 00-8

5. Block thickness: Minimum 4.8 mm (3/16 inch). Thickness sized for rabbet depth as required.

C. Spacers: ASTM C864:

1. Channel shape having a 6 mm (1/4 inch) internal depth.

2. Flanges not less 2.4 mm (3/32 inch) thick and web 3 mm (1/8 inch) thick.

3. Lengths: One to 25 to 76 mm (one to three inches).

4. Shore a hardness of 40 to 50 Durometer.

D. Sealing Tapes:

1. Semi-solid polymeric based material exhibiting pressure-sensitive adhesion and withstanding exposure to sunlight, moisture, heat, cold, and aging.

2. Shape, size and degree of softness and strength suitable for use in

Spacer: Galvanized steel wire or strip designed to position glazing application to prevent water infiltration.

E. Spring Steel glazing in channel or rabbeted sash with stops.

F. Glazing Clips: Galvanized steel spring wire designed to hold glass in position in rabbeted sash without stops.

G. Glazing Points (Sprigs): Pure zinc stock, thin, flat, triangular or diamond shaped pieces, 6 mm (1/4 inch) minimum size.

H. Glazing Gaskets: ASTM C864:

1. Firm dense wedge shape for locking in sash.

2. Soft, closed cell with locking key for sash key.

3. Flanges shall terminate above the glazing-beads or terminate flush with top of beads.

I. Lock-Strip Glazing Gaskets: ASTM C542, shape, size, and mounting as indicated.

J. Glazing Sealants: ASTM C920, silicone neutral cure:

1. Type S.

2. Class 25

3. Grade NS.

4. Shore A hardness of 25 to 30 Durometer.

K. Structural Sealant: ASTM C920, silicone acetoxy cure:

1. Type S.

2. Class 25.

3. Grade NS.

4. Shore a hardness of 25 to 30 Durometer.

08 80 00-9

L. Neoprene, EPDM, or Vinyl Glazing Gasket: ASTM C864.

1. Channel shape; flanges shall terminate above the glazing channel or flush with the top of the channel.

2. Designed for dry glazing.

M. Color:

1. Color of glazing compounds, gaskets, and sealants used for aluminum color frames shall match color of the finished aluminum and be non-staining.

2. Color of other glazing compounds, gaskets, and sealants which shall be exposed in the finished work and unpainted shall be black, gray, or neutral color.

N. Smoke Removal Unit Targets: Adhesive targets affixed to glass to identify glass units intended for removal for smoke control. Comply with requirements of local Fire Department.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Verification of Conditions:

1. Examine openings for glass and glazing units; determine they are proper size; plumb; square; and level before installation is started.

2. Verify that glazing openings conform with details, dimensions and tolerances indicated on manufacturers’ approved shop drawings.

B. Advise Contractor of conditions which shall adversely affect glass and glazing unit installation, prior to commencement of installation: Do not proceed with installation until unsatisfactory conditions have been corrected.

C. Verify that wash down of adjacent masonry is completed prior to erection of glass and glazing units to prevent damage to glass and glazing units by cleaning materials.

3.2 PREPARATION

A. For sealant glazing, prepare glazing surfaces in accordance with GANA-

02 Sealant Manual.

B. Determine glazing unit size and edge clearances by measuring the actual unit to receive the glazing.

C. Shop fabricate and cut glass with smooth, straight edges of full size required by openings to provide GANA recommended edge clearances.

D. Verify that components used are compatible.

08 80 00-10

E. Clean and dry glazing surfaces.

F. Prime surfaces scheduled to receive sealants, as determined by preconstruction sealant-substrate testing.

3.3 INSTALLATION - GENERAL

A. Install in accordance with GANA-01 Glazing Manual and GANA-02 Sealant

Manual unless specified otherwise.

B. Glaze in accordance with recommendations of glazing and framing manufacturers, and as required to meet the Performance Test

Requirements specified in other applicable sections of specifications.

C. Set glazing without bending, twisting, or forcing of units.

D. Do not allow glass to rest on or contact any framing member.

E. Glaze doors and operable sash, in a securely fixed or closed and locked position, until sealant, glazing compound, or putty has thoroughly set.

F. Tempered Glass: Install with roller distortions in horizontal position unless otherwise directed.

G. Laminated Glass:

1. Tape edges to seal interlayer and protect from glazing sealants.

2. Do not use putty or glazing compounds.

H. Insulating Glass Units:

1. Glaze in compliance with glass manufacturer's written instructions.

2. When glazing gaskets are used, they shall be of sufficient size and depth to cover glass seal or metal channel frame completely.

3. Do not use putty or glazing compounds.

4. Do not grind, nip, cut, or otherwise alter edges and corners of fused glass units after shipping from factory.

5. Install with tape or gunnable sealant in wood sash.

3.4 INSTALLATION - WET METHOD (SEALANT AND SEALANT)

A. Place setting blocks at 1/3 points and install glazing pane or unit.

B. Install removable stops with glazing centered in space by inserting spacer shims both sides at 600 mm (24 inch) intervals, 6 mm (1/4 inch) below sight line.

C. Fill gaps between glazing and stops with sealant to depth of bite on glazing, but not more than 9 mm (3/8 inch) below sight line to ensure full contact with glazing and continue the air and vapor seal.

D. Apply sealant to uniform line, flush with sight line. Tool or wipe sealant surface smooth.

08 80 00-11

3.5 REPLACEMENT AND CLEANING

A. Clean new glass surfaces removing temporary labels, paint spots, and defacement after approval by Contracting Officer Representative (COR).

B. Replace cracked, broken, and imperfect glass, or glass which has been installed improperly.

C. Leave glass, putty, and other setting material in clean, whole, and acceptable condition.

3.6 PROTECTION

A. Protect finished surfaces from damage during erection, and after completion of work. Strippable plastic coatings on colored anodized finish are not acceptable.

3.7 GLAZING SCHEDULE

A. Tempered Glass:

1. Install in full and half glazed doors unless indicated otherwise.

2. Install in storefront, windows, and door sidelights adjacent to doors.

3. Use clear tempered glass on interior side lights and doors, and on exterior doors and sidelights unless otherwise indicated or specified.

4. Use clear tempered glass in exterior and interior panes unless specified otherwise at insulating glass units adjacent to door.

B. Clear Glass:

1. Interior observation windows not specified otherwise.

2. Interior pane of triple glazed windows not receiving tempered, laminated or organic coated glass, or other special glass indicated or specified.

C. Tinted Glass: Exterior pane of dual glazed windows not receiving tinted tempered glass.

D. Insulating Glass:

1. Install SEU clear tempered glass in windows, and curtain walls adjacent to entrances or walks.

2. Install SEU clear glass in windows and curtain walls not adjacent to entrances or walks.

3. Install SEU clear tempered glass in curtain walls adjacent to entrances or walks.

E. Laminated Glass: Install as specified in doors, observation windows and interior pane of dual glazed windows where indicated.

08 80 00-12

1. Provide laminated glass for all windows in Psychiatric Nursing

Units, Alcohol Dependency Treatment Nursing Units, Drug Abuse

Treatment Nursing Units and Security Bedrooms. Laminated glass shall be 7/16-in thick in locked patient units and security rooms, 5/16-in thick elsewhere. (Min. 1.5 mm interlayer).

2. If laminated glass is required for triple glazed windows, provide it for interior panes only.

F. Spandrel Glass: Install specified spandrel glazing where indicated.

- - - E N D - - -