36C24418B0594-0001004.pdf
PDF 54 KB Posted
- Attached to
- Construct Smoking Shelters, Project 542-18-108 Federal contract opportunity
- Solicitation number
- 36C24418B0594
About this file
36C24418B0594 0001 SOW Sidewalks -Attachment C.pdf
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C24418C0273-000.docx | DOCX document | |
| 36C24418B0594-0001007.pdf | ||
| 36C24418B0594-0001001.pdf | ||
| 36C24418B0594-0001003.pdf | ||
| 36C24418B0594-0001002.pdf | ||
| 36C24418B0594-0001005.pdf | ||
| 36C24418B0594-0001006.docx | DOCX document | |
| 36C24418B0594-0001000.docx | DOCX document | |
| 36C24418B0594-001.docx | DOCX document | |
| 36C24418B0594-000.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work for Sidewalks ‐Attachment C:
542‐18‐108 Smoke Shelters
Coatesville VA Medical Center (CVAMC), Coatesville, PA.
REQUIREMENTS: Contractor shall have knowledge of all aspects pertaining to this statement of work and shall perform as per specifications as outlined in Master Construction Specifications.
Contractor shall:
A. Provide all labor, tools, materials, quality supervision, etc. required to construct (6) six sidewalks (one for each smoke shelter) from the nearest existing sidewalk to the smoke shelter poured‐in place concrete slab. The sidewalk dimensions shall be (5) 5 feet wide by (6) six inches thick and various lengths dependent upon the final approved positions of the smoke shelter poured‐in‐place concrete slabs. Shelters shall be located as shown on attachment “A” of this document. Exact location shall be installed per final approval of the project Contracting Officer Representative (COR). See Attachment “B” for shelters performance specifications and concrete slab requirements as well as Attachment “C” for construction detail.
B. Contractor is responsible to verify all site conditions prior to performing any work. Follow all Guidelines and Standards, applicable to the task, as described in the Construction Safety Standards and Master Construction Specifications.
C. Before opening any excavation, efforts shall be made to determine if there are underground utilities in the area and they shall be located and protected during the excavation operations. As‐built drawings are available for review however; contractor shall not rely on drawings as sole source of locating underground utilities. It will be required for the contractor to employ the services of a Subsurface Utility Engineering firm to conduct surveys to locate all underground utilities in the areas to be excavated. In some circumstances these conventional methods do not precisely locate the utilities, in which case the following additional means may be utilized: TV video pipe inspection, ground penetrating radar (for non‐ metallics), and vacuum excavation. The Subsurface Utility Engineering Analyst must maintain necessary traffic control and safety standards to deliver a comprehensive report on all underground utilities.
Survey ground marks must be laid out and a computer‐generated illustration of job‐site must be provided. The Utility Location & Coordination Uniform Color Code must be used for the ground marks and illustrations.
D. Contractor is responsible to replace concrete walkways that were removed, disrupted, or damaged during this project. Damages shall be replaced, not repaired.
E. Protect adjacent structures, equipment, vehicles and vegetation. Contractor is responsible to repair all grounds, pavements, and any other damages caused during this project.
F. Ensure work site is properly cleaned up when work is complete.
G. Dispose of all residues off site in strict accordance with all applicable Federal, State and Local regulations.
H. Contractor must provide (2) forms of identification, one of which must be a photo I.D.(i.e. a valid driver’s license) and will be required to pass a security background check prior to being granted permission to enter the CVAMC facility.
Minimum Standards of Workmanship:
All work shall be performed in compliance with all Federal, State and Local Laws and Regulations. In addition, work will meet equipment’s manufacturer and generally accepted industry standards of good workmanship. All waste materials shall be disposed of by the contractor in compliance with Federal State and Local laws and regulations.
File details come from the government source that posted it.