36C24418B0575-003.pdf

PDF 3 MB Posted

Attached to
Correct AC Deficiencies in Biomedical and Mailroom Federal contract opportunity
Solicitation number
36C24418B0575
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4

About this file

36C24418B0575 Correct Air Conditioning Deficiencies in Biomedical Shop and Mailroom, Project No 503-17-104, 100_ Bid Documents Drawings.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Correct AC Deficiencies in Biomedical and Mailroom, newest first.
File Type Posted
36C24418B0575-0001001.pdf PDF
36C24418B0575-0001000.docx DOCX document
36C24418B0575-0001002.pdf PDF
36C24418B0575-0001003.pdf PDF
36C24418B0575-005.docx DOCX document
36C24418B0575-007.docx DOCX document
36C24418B0575-006.docx DOCX document
36C24418B0575-004.docx DOCX document
36C24418B0575-002.pdf PDF
36C24418B0575-001.docx DOCX document
36C24418B0575-000.docx DOCX document
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

3/

/2

3:

:4

P

M CORRECT AIR CONDITIONING

DEFICIENCIES IN BIOMEDICAL

SHOP AND MAILROOM

503-17-104

JG JA

JAMES E. VAN ZANDT MEDICAL CENTER

ALTOONA, PA 16602

G001

COVER SHEET

MARCH 27, 2018

17029

BID DOCUMENTS

CORRECT AIR CONDITIONING

DEFICEINCIES IN BIOMEDICAL

SHOP AND MAILROOM

JAMES E. VAN ZANDT VA MEDICAL CENTER

2907 PLEASANT VALLEY BLVD.

ALTOONA, PA 16602

VICINITY MAP: ALTOONA, PENNSYLVANIA

SITE

LOCATION MAP:

JAMES E. VAN ZANDT VA MEDICAL CENTER

SITE

PROJECT DIRECTORY

OWNER:

JAMES E. VAN ZANDT VA MEDICAL CENTER

2907 PLEASANT VALLEY BLVD.

ALTOONA, PA 16602

(814) 943-8164

CONTACT: ZACH WASSER

ARCHITECT/ENGINEER:

AE WORKS, LTD

209 SANDUSKY STREET

PITTSBURGH, PA 15206

(412) 287-7333

CONTACT: JULIE GOOD, PE

DRAWING INDEX

SHEET # SHEET NAME IS

S

U E

IS

S

U E

GENERAL

G001 COVER SHEET •

ARCHITECTURAL

A001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES

A002 BASEMENT - CONTRACTOR WORK PATH PLAN

A130 BASEMENT CEILING PLANS

MECHANICAL

H001 HVAC SYMBOLS, ABBREVIATIONS AND GENERAL NOTES

HD100 PARTIAL BASEMENT HVAC DEMOLITION PLAN

H100 PARTIAL BASEMENT HVAC PLAN

H600 HVAC DETAILS

H700 HVAC SCHEDULES AND CONRTOLS

ELECTRICAL

E001 ELECTRICAL SYMBOLS, ABBREVIATIONS AND NOTES

E101 BIO MEDICAL SHOP LIGHTING PLAN, SCHEDULES AND DETAILS

SYMBOLS LEGEND

DESCRIPTION SYMBOL

DRAWING BLOCK TITLE MARK

ITEM SCALE

ITEM TITLE / DESCRIPTION

ITEM NUMBER / LETTER

WALL SECTION MARK

A101

SHEET NUMBER

SECTION IDENTIFIER

BUILDING SECTION MARK

A101

SHEET NUMBER

SECTION IDENTIFIER

DETAIL INDICATOR

A101

DETAIL IDENTIFIER

SHEET NUMBER

LEADER

DETAIL BOUNDARY

EXTERIOR ELEVATION MARK

A100

INTERIOR ELEVATION MARK

(SINGLE VIEW)

A100

INTERIOR ELEVATION MARK

(MULTIPLE VIEWS)

A100

ELEVATION IDENTIFIER

SHEET NUMBER

ELEVATION IDENTIFIER

SHEET NUMBER

ELEVATION IDENTIFIER

SHEET NUMBER

NORTH ARROW

NORTH

TRUE NORTH

PROJECT

ROOM NAME

ROOM NUMBER

ROOM NAME INDICATOR

COLUMN GRID IDENTIFICATION

GRID LINE IDENTICATION

COLUMN GRID LINE

DOOR IDENTIFICATION

1 DOOR NUMBER

W#WINDOW IDENTIFICATION WINDOW / CURTAINWALL TYPE

WALL TYPE IDENTIFICATION

M8 WALL TYPE INDICATOR

WALL

KEYED NOTE IDENTIFICATION

REVISION IDENTIFICATION

REVISION CLOUD

REVISION NUMBER

DATUM POINT IDENTIFICATION

LEVEL

10'-0"

ELEVATION RELATIVE TO

FIRST FLOOR TOP OF SLAB

WALL FINISH PT#

FINISH

EXTENT OF FINISH

ROOM NAME

DEMO PLAN - KEYED NOTE

PLAN - KEYED NOTE

WALL SECTION / EXTERIOR ELEVATION - KEYED NOTE

EARTH -

COMPACTED FILL

GRAVEL, CRUSHED STONE

SAND, GROUT, LIMESTONE

WOOD, FINISH

WOOD, FRAMING

THROUGH MEMBER

WOOD, FRAMING

INTERRUPTED MEMBER

PLYWOOD

ACOUSTIC TILE

RIGID INSULATION

TAPERED

INSULATION

BATT INSULATION

CONCRETE

BRICK

CONCRETE BLOCK

STEEL

GYPSUM BOARD, PLASTER

MATERIALS LEGEND :

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

3/

/2

3:

:4

P

M CORRECT AIR CONDITIONING

DEFICIENCIES IN BIOMEDICAL

SHOP AND MAILROOM

503-17-104

JG TP

JAMES E. VAN ZANDT MEDICAL CENTER

ALTOONA, PA 16602

A001

ARCHITECTURAL SYMBOLS, ABBREVIATIONS

AND GENERAL NOTES

MARCH 27, 2018

14-

BID DOCUMENTS

SS SOIL STACK

ST PR STATIC PRESSURE

ST STL STAINLESS STEEL

STD STANDARD

STER STERILIZER

STL STEEL

STOR STORAGE

STR STRAINER

STRUCT STRUCTURAL

SUSP SUSPENDED

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

SYM SYMMETRICAL TOP

T TOP

TA THROWAWAY

TAN TANGENT

TC TELECOMMUNICATIONS

CONTRACTOR

TCV TEMPERATURE CONTROL VALVE

TDV TRIPLE DUTY VALVE

TEL TELEPHONE

TEMP TEMPERATURE

TER TERRAZZO

TG TONGUE & GROOVE

TH THERMOMETER

THRES THRESHOLD

TR TEMPERATURE RISE

TRANS TRANSITION

TRANSR TRANSFORMER

TSTAT THERMOSTAT

TV TURNING VANES OR TELEVISION

TYP TYPICAL

UC UNDER CABINET OR UNDER CUT

UFD UNDER FLOOR DUCT

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITER'S LABORATORIES

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

VAL VALVE

VD VOLUME DAMPER

VENT VENTILATION

VERT VERTICAL

VFS VENTURI FLOW STATION

VIF VERIFY IN FIELD

VL VENT LINE

VR VAPOR RETARDER

VS VENT STACK

VTR VENT THROUGH ROOF

W WATT

W/ WITH

W/O WITHOUT

WB WET BULB

WC WALL COVERING

WCL WATER CLOSET

WD WOOD

WF WIDE FLANGE

WFMD WATER FLOW MEASURING DEVICE

WG WALL GUARD OR WATER GAUGE

WHCH WHEEL CHAIR

WIN WINDOW

WMS WIRE MESH SCREEN

WP WEATHERPROOF

WPS WALL PROTECTION SYSTEM

WSCT WAINSCOT

WT WINDOW TREATMENT

WTD WATER TEMPERATURE DROP

WWF WELDED WIRE FABRIC

X DEMO

XN TO BE RELOCATED / NEW LOCATION

XR EXISTING TO REMAIN

ZVB ZONE VALVE BOX

ZVC ZONE VALVE CABINET

LDB LEAVING DRY BULB

LED LIGHT EMITTING DIODE

LF LINEAR FEET

LIN LINEAR

LOC LOCATION OR LOCATE

LPT LOW POINT

LSDC LINEAR SUPPLY DIFFUSER CEILING

LT LIGHT

LTG LIGHTING

LV LOW VOLTAGE

LVR LOUVER

LWB LEAVING WET BULB

LWC LINEAR WOOD CEILING

LWT LEAVING WATER TEMPERATURE

MAN MANUAL

MAT MIXED AIR TEMPERATURE

MATL MATERIAL

MAV MANUAL AIR VENT

MAX MAXIMUM

MBH ONE THOUSAND BTU / HOUR

MC MECHANICAL CONTRACTOR

MC METAL CLAD CABLE

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MEMB MEMBRANE

MET METAL

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MO MASONRY OPENING

MOD MOTOR OPERATED DAMPER

MONO MONOLITHIC

MTD MOUNTED

MTG HT MOUNTING HEIGHT

MTL METAL

MTLH METAL HALIDE

MTR MOTOR

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

N/A NOT APPLICABLE

NEC NATIONAL ELECTRIC CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NUMBER OR NORMALLY OPEN

NOM NOMINAL

NTS NOT TO SCALE

O OXYGEN

OA OUTSIDE AIR

OBD OPPOSED BLADE DAMPER

OC ON CENTER

OD OUTSIDE DIAMETER

OPER OPERATED

OPNG OPENING

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

PB PULL BOX

PC PLUMBING CONTRACTOR

PD PUMP DISCHARGE

PG PRESSURE GAUGE WITH COCK

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PNL PANEL

PR PAIR

PRD PRESSURE DIFFERENTIAL VALVE

PRELIM PRELIMINARY

PRT PRESSURE TAP

PRV PRESSURE REDUCING VALVE

PT PAINT OR POTENTIAL

TRANSFORMER

RO ROUGH OPENING

QT QUARRY TILE

R RADIUS

RA RETURN AIR / RELIEF AIR

RB RUBBER BASE

RC REMOVE COMPLETELY

RD ROOF DRAIN

RE RELOCATE EXISTING

REC RECESSED

RECPT RECEPTACLE

REF REFERENCE

REFL REFLECTOR

REG REGISTER

REINF REINFORCING

REM REMOVE

REQD REQUIRED

RET RETURN

REV REVISE

REX REMOVE EXISTING

RF RESILIENT FLOOR

RFI REQUEST FOR INFORMATION

RGS RIGID GALVANIZED STEEL CONDUIT

RH ROOF HATCH

RM ROOM

RN REMOVE AND REPLACE WITH NEW

RR REMOVE AND REPLACE

RS RAPID START

RV RELIEF VALVE

RWC RAIN WATER CONDUCTOR

SA SUPPLY AIR

SAN SANITARY SEWER ABOVE GROUND

SAN-BXR SANITARY SEWER - BURIED

EXISTING TO REMAIN

SAN-XR SANITARY SEWER ABOVE GROUND -

EXISTING TO REMAIN

SCHED SCHEDULE

SD SMOKE DAMPER OR SMOKE

DETECTOR

SDISP SOAP DISPENSER

SF SQUARE FOOT

SHT SHEET

SHT MTL SHEET METAL

SHTG SHEATHING

SIM SIMILAR

SM SURFACE MOUNTED

SNC SANITARY NAPKIN CABINET

SND SANITARY NAPKIN DISPOSER

SP STANDPIPE OR STATIC PRESSURE

SPC SPECIMEN PASS-THRU CABINET

SPEC SPECIFICATIONS

SPS STATIC PRESSURE SENSOR

SR SERVICE RECEPTOR

EIFS EXTERIOR INSULATION AND

FINISHING SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEC CAB ELECTRICAL CABINET

ELEV ELEVATOR

EMER EMERGENCY

ENCL ENCLOSURE

ENTR ENTRANCE

EO ELECTRICAL OUTLET

EQ EQUAL

EQUIP EQUIPMENT

ETR EXISTING TO REMAIN

EWB ENTERING WET BULB

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

EX EXAUST AIR

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

XP EXPLOSION PROOF

F/S FIRE / SMOKE DAMPER

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FAT FINAL AIR TEMPERATURE

FB FIRE BLANKET

FC FLEXIBLE CONNECTION OR

FOOTCANDLE

FD FLOOR DRAIN OR FIRE DAMPER

FDN FOUNDATION

FDV FIRE DEPARTMENT VALVE

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FH FIRE HOSE

FHC FIRE HOSE CABINET

FHP FULL HEIGHT PARTITION

FHV FIRE HOSE VALVE

FIN FINISH

FIXT FIXTURE

FL FLOW LINE

FLA FULL LOAD AMPERES

FLASH FLASHING

FLEX FLEXIBLE

FLG FLANGE

FLG C FLANGE CONNECTION

FLR FLOOR

FLUOR FLUORESCENT

FP FIRE PROOFING

FRMG FRAMING

FS FLOOR SINK

FSTOP FIRESTOPPING

FT FOOT / FEET

FT HD FEET OF HEAD

FTC FOOTCANDLES

FTG FOOTING

FUR FURRING

G GAS OR ELECTRICAL GROUND

GA GAUGE

GAL GALLONS

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GEN GENERATOR

GENL GENERAL

GFCI GROUND FAULT CIRCUIT

INTERRUPTOR

GL GLASS

GLV GLOBE VALVE

GND GROUND

GPM GALLONS PER MINUTE

GR GRADE

GRAV GRAVITY

GRD BM GRADE BEAM

GV GATE VALVE

GWB GYPSUM BOARD

H HIGH

HB HOSE BIB

HC HEATING CONTRACTOR

HDCP HANDICAP

HDR HEADER

HDW HARDWARE

HID HIGH INTENSITY DISCHARGE

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HORSE POWER

HPD HIGH PRESSURE DRIP

HPF HIGH POWER FACTOR

HR HANDRAIL

HSKP HOUSEKEEPING

HT HEIGHT

HTG HEATING

HTR HEATER

HV HIGH VELOCITY

HVAC HEATING, VENTILATING, AIR

CONDITIONING

HW HOT WATER

HWD HARD WOOD

HWR HOT WATER RETURN

HWS HOT WATER SUPPLY

HWS&R HOT WATER SUPPLY AND RETURN

HZ HERTZ

ID INSIDE DIAMETER

IER INVERTED ECCENTRIC REDUCER

IG ISOLATED GROUND

IME INSULATED METAL ENCLOSURE

IN INCH

INCAND INCANDESCENT

INCL INCLUDED

INSUL INSULATION

INT INTERIOR

INTERL INTERLOCK

INV INVERT

ISO ISOLATION

IVS ISOLATED VALVE STATION

J-BOX JUNCTION BOX

JST JOIST

JT JOINT

KO KNOCK OUT

kVA KILOVOLT AMPERE kVAR KILOVAR (REACTANCE) kW KILOWATT kWH KILOWATT HOUR METER

LAT LEAVING AIR TEMPERATURE

LAV LAVATORY

LB POUND

& AND

A AIR (CLINICAL)

AAP ALARM ANNUNCIATOR PANEL

AAV AUTOMATIC AIR VENT

AB ANCHOR BOLT

ABV ABOVE

ACC DR ACCESS DOOR

ACFL ACCESS

ACOUS ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICAN DISABILITIES ACT

ADD ADDENDUM

ADDL ADDITIONAL

ADJ ADJUSTABLE

ADMIN ADMINISTRATION

AFF ABOVE FINISH FLOOR

AFG ABOVE FINISHED GRADE

AFMD AIR FLOW MEASURING DEVICE

AHU AIR HANDLING UNIT

AL ALIGN

ALT ALTERNATE

ALUM ALUMINUM

AMP AMPERE

AP ACCESS PANEL

APC ARCHITECTURAL PRECAST

CONCRETE

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASY ASYMMETRIC

ATC AUTOMATIC TEMPERATURE

CONTROL

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AWT AVERAGE WATER TEMPERATURE

BAT BATTERY

BC BALANCING COCK OR BARE

COPPER

BDD BACKDRAFT DAMPER

BFC BELOW FINISH CEILING

BFE BOTTOM FOOTING ELEVATION

BFG BELOW FINISHED GRADE

BG BUMPER GUARD

BLDG BUILDING

BLKG BLOCKING

BLT BORROWED LIGHT

BLW BELOW

BM BEAM

BO BY OWNER

BOF BY OWNER FUTURE

BOT BOTTOM

BR BRICK

BRG BEARING

BRKR BREAKER

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT UP ROOFING

C CONDUIT

CAB CABINET

CANTL CANTILEVER

CAP CAPACITY

CATV CABLE TELEVISION

CCT CUBICLE CURTAIN TRACK

CCTV CLOSED CIRCUIT TELEVISION

CFH CUBIC FEET / HOUR

CFM CUBIC FEET / MINUTE

CH CHANNEL

CHK V CHECK VALVE

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CHWS&R CHILLED WATER SUPPLY AND

RETURN

CJ CONTROL JOINT

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CL CENTERLINE

CLG CEILING

CLG MTD CEILING MOUNTED

CLR CLR

CMU CONCRETE MASONRY UNIT

CO CLEAN OUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUE / CONTINUOUS

CONTR CONTRACTOR

CONV CONVECTOR

COORD COORDINATE

CORR CORRIDOR

CPT CARPET OR CONTROL POWER

TRANSFORMER

CT CERAMIC TILE

CTR CENTER

CU COPPER

CV CONTROL VALVE

CW COLD WATER

D DEPTH OR DEEP

DB DRY BULB

dB DECIBEL

DCW DOMESTIC COLD WATER

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAILS

DF DRINKING FOUNTAIN

DHW DOMESTIC HOT WATER

DIA DIAMETER

DIAG DIAGONAL OR DIAGRAM

DIFF DIFFUSER

DIM DIMENSION

DISC DISCONNECT

DISCH DISCHARGE

DISP DISPENSER

DIST DISTRIBUTION

DIV DIVISION

DL DOWN LIGHT

DN DOWN

DP DISTRIBUTION PANEL

DPR DAMPER

DR DRAIN

DS DOWNSPOUT

DWG DRAWING

DX DIRECT EXPANSION

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EC ELECTRICAL CONTRACTOR

EDB ENTERING DRY BULB

EF EXHAUST FAN

ABBREVATION LEGEND

1/8" = 1'-0"

TITLE

GENERAL PROJECT NOTES

1 ALL CONSTRUCTION WORK SHALL CONFORM WITH THE APPLICABLE CODES AND ORDINANCES OF THE LOCAL JURISDICTION, THE COMMONWEALTH OF PENNSYLVANIA, AND THE CURRENT ADOPTED VERSION OF THE INTERNATIONAL BUILDING CODE FAMILY. THE CONTRACTOR SHALL POST NOTICES AND COMPLY

WITH THE GOVERNING LAWS OF THE JURISDICTION.

2 INSTALLATIONS PERFORMED IN CONNECTION WITH THESE DRAWINGS SHALL COMPLY WITH THE MOST

RECENT NFPA EDITION.

3 THE SITE WORK SHALL BE PROPERLY SUPERVISED BY THE CONTRACTORS JOB SITE SUPERINTENDANT.

SUFFICIENT PERSONNEL SHALL BE EMPLOYED TO COMPLETE THE WORK WITHIN THE CONTRACTED TIME.

PERSONNEL SHALL BE SKILLED IN THE TASK ASSIGNED.

4 THE CONTRACTOR SHALL, AT ALL TIMES, MAINTAIN ADEQUATE PROTECTION TO SAFEGUARD THE PUBLIC

AND ALL PERSONS ENGAGED IN THE PERFORMANCE OF THE WORK.

5 THE DRAWINGS REFLECT CONDITIONS AS CAN BE INFERRED FROM VISIBLE CONDITIONS, OR FROM

DRAWINGS AND INFORMATION FURNISHED BY THE OWNER, BUT CANNOT BE GUARANTEED. THE

CONTRACTOR SHALL VERIFY ALL GRADES, LINE LEVELS AND DIMENSIONS INDICATED ON THE DRAWNGS AND SHALL REPORT ALL INCONSISTENCIES TO THE ARCHITECT PRIOR TO THE EXECUTION OF THE WORK.

RECHECK ALL DIMENSIONS PRIOR TO ORDERING MANUFACTURED AND/OR FABRICATED ITEMS.

6 PLAN DIMENSIONS, UNLESS NOTED OTHERWISE, ARE TO THE FACE OF THE WALL FINISH OR CENTERLINE

OF COLUMN.

7 ALL INDICATIONS OF MASONRY ARE SHOWN IN ACTUAL DIMENSIONS (NOT NOMINAL), UNLESS NOTED

OTHERWISE.

8 THE CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR PROTECTION AND SAFEKEEPING OF PRODUCTS PURCHASED FOR THIS PRODUCT AND STORED ON THE PROJECT SITE. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ON PREFERRED LOCATIONS FOR STORED MATERIALS ON THE

PROJECT SITE, IF ALLOWED AS PART OF THE REQUIREMENTS OF THIS PROJECT.

9 THE CONTRACTOR SHALL MAINTAIN AREAS UNDER THE CONTRACTOR'S CONTROL TO BE FREE OF WASTE MATERIALS, DEBRIS, AND RUBBISH. CONTAINERS FOR DEPOSIT OF DEBRIS AND RUBBISH SHALL BE

PROVIDED BY THE CONTRACTOR. COORDINATE LOCATION OF CONTAINERS WITH THE OWNER'S

REPRESENTATIVE PRIOR TO PLACEMENT. REMOVE AND DISPOSE OF DEMOLITION MATERIAL OFF SITE IN

ACCORDANCE WITH APPLICABLE CODES AND/OR SPECIFICATIONS.

10 EXTRANEOUS MATERIALS SHALL BE PERIODICALLY REMOVED, AND AT THE CONCLUSION OF THE PROJECT. ALL UNUSED TOP SOIL SHALL BE STOCKPILED ON THE SITE FOR THE OWNER'S USE.

11 THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL FIRESAFING / FIRESTOPPING MATERIALS AT ALL THROUGH-WALL AND THROUGH-CEILING PENETRATIONS AS REQUIRED FOR THE CONSTRUCTION WORK AND TO MAINTAIN FIRE RATINGS OF FLOORS AND WALLS. MATERIALS AND INSTALLATION DETAILS SHALL CONFORM TO UNDERWRITER LABORATORIES LISTING FOR RATED

ASSEMBLIES.

12 ALL WOOD FRAMING AND SHEATHING SHALL BE FIRE RETARDANT TREATED AS REQUIRED BY THE

BUILDING CODE CLASSIFICATION OF 'NONCOMBUSTIBLE'

13 DO NOT SCALE DRAWINGS. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION.

NOTIFY THE ARCHITECT OF ANY DEVIATIONS OR DISCREPANCIES FOUND AND RECEIVE DIRECTION

BEFORE PROCEEDING.

14 DURING CONSTRUCTION THE CONTRACTOR WILL WORK ADJACENT TO PATIENT OCCUPIED FLOORS.

CONSTRUCTION RELATED ACTIVITIES ARE NOT TO ADVERSELY IMPACT THESE AREAS. CONSTRUCTION RELATED ACTIVITIES THAT MIGHT AFFECT THESE AREAS MUST BE COORDINATED WITH AND APPROVED

BY THE VA PRIOR TO OCCURRENCE.

15 CONTRACTOR SHALL PROVIDE TEMPORARY DUST ENCLOSURES DURING ALL DEMOLITION AND

CONSTRUCTION ACTIVITIES. CONTRACTOR TO COORDINATE LOCATIONS WITH CONTRACTING OFFICER. IF EXISTING WALLS ARE USED, PENETRATIONS MUST BE SEALED TO CREATE A DUST PROOF ENCLOSURE.

16 MODIFICATIONS TO THE EXISTING MEP SYSTEMS WILL IMPACT ADJACENT SPACES OUTSIDE THE GENERAL SCOPE OF WORK. ANY DISTURBANCE OF EXISTING CONDITIONS AND FINISHES MUST BE

REPAIRED TO MATCH THE CONDITIONS PRIOR TO CONSTRUCTION IMPACTS.

17 THE FACILITY IS OPERATIONAL. CONTRACTOR SHALL MAKE PROVISIONS FOR OWNER AND PUBLIC USE OF THE BUILDING AROUND THE CONSTRUCTION AREA. DELIVERIES, STAGING, STORAGE OF MATERIALS AND OTHER CONSTRUCTION RELATED ACTIVITIES SHALL BE COORDINATED WITH THE CONTRACTING OFFICER

SO AS TO NOT ADVERSELY AFFECT THE BUILDING OPERATIONS.

18 ASBESTOS AND LEAD ARE NOT ANTICIPATED TO EXIST IN THE WORK AREA. HOWEVER, IF

ASBESTOS-CONTAINING MATERIAL IS DISCOVERED OR SUSPECTED, STOP WORKING IN THE AREA

IMMEDIATELY AND CONTACT THE CONTRACTING OFFICER.

19 ALL REVISIONS TO THE DRAWINGS MUST PROCEED THROUGH THE ARCHITECT. OWNER / CONTRACTOR

REVISIONS MAY BE CONSIDERED INVALID.

20 ALL EXPOSED GYPSUM WALL BOARD EDGES TO HAVE METAL EDGE TRIM.

21 THE CONTRACTOR RESPONSIBLE FOR COMPARING AND COORDINATING ALL DRAWINGS FOR PROPER FIT AND ATTACHMENT OF ALL PARTS. DETAILS NOT SHOWN OR DESCRIBED IN THESE NOTES SHALL BE CONSTRUCTED TO SAME SIZE AND CHARACTER AS FOR SIMILAR CONDITIONS WHICH ARE SHOWN, SPECIFIED, OR COMMONLY CONSTRUCTED IN THE INDUSTRY.

22 NO STRUCTURAL MEMBER SHALL BE OMITTED, NOTCHED, CUT, BLOCKED OUT, OR RELOCATED WITHOUT

PRIOR APPROVAL BY THE ARCHITECT OR ENGINEER.

23 PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONTRACTOR TO PROTECT ADJACENT PROPERTY AT

ALL TIMES DURING CONSTRUCTION.

24 ALL TEMPORARY BRACING AND SHORING SHALL BE DESIGNED TO SUSTAIN ALL CONSTRUCTION LOADS, SOIL PRESSURE, LATERAL AND OTHER LOADS TO WHICH THE STRUCTURE MAY BE SUBJECTED.

25 CONTRACTOR SHALL COORDINATE LOCATIONS OF LIGHT FIXTURES, SPRINKLER HEADS, REGISTERS, ETC.

WITH THE REFLECTED CEILING PLAN LAYOUT.

26 ALL SPRINKLER HEADS, DIFFUSERS AND REGISTERS SHALL BE CENTERED WITH SUSPENDED

ACOUSTICAL PANELS, UNLESS NOTED OTHERWISE ON DRAWINGS.

27 ALL VOIDS IN MASONRY, CONCRETE AND OTHER ASSEMBLIES CREATED AROUND PENETRATIONS SHALL

BE FILLED / PATCHED WITH CONSTRUCTION TO MATCH SURROUNDING CONDITIONS.

28 CONTRACTOR IS RESPONSIBLE FOR PAINTING ALL EXPOSED STEEL, DECKING, PIPING, CONDUIT, SPRINKLER PIPING AND DUCTS WHICH ARE EXPOSED IN AREAS WITH NO CEILINGS AND SCHEDULED TO

RECEIVE PAINT FINISH AS INDICATED ON THE FINISH SCHEDULE.

22 22A

47B

26A

S00

E02

27A

29 29A 30

31 32

32B 32C47A

28A

18B

18A

E00

E00A

E00B

5B

5A

13A

S03

7A

1A

S02

42A

42B

35 37

37A

48C

S01

A000A

A000 A000C

AS000

A000E

31A

S04

A000B

A000K A000J A000I A000H A000G A000F

A000D

16B

SHR RM

41A

41A

41C

41D

SF

SF

SF

MECH RM ENG

SVC

ELEC SHOPENG

SVC

CHIEF

M&R

OFFICE

STOR

MACHINE SHOP

PLUMBING

SHOP

ENG

SVC

CARPENTER SHOP ENG

SVC

PLAN

RM

CORR

PAINT

SHOP

M TLT

EMS

STAIRS

MECH

RM

ELEV

LOBBY

MAIL ROOM

MAS

STOR

MAS

STORAGE

MAS

BIO-MED

SHOP

STOR

A&MM

FHC MCCORR

FHC

MECH RM ENG

SVC

CORR

STORAGE ENG

SVC

ELEV

ELEV

ELEV

A/C SHOP ENG

SVC

CORR

TELE

EC

FHC

STORAGE

VCS

STAIRS

OFFICE CRED

UN

CRED

UN

OFFICE CRED

UN

LOCKER

RM

CLO

OFFICE

EMS

CH OFF

VCS

RETAIL

STORE

RETAIL

STOR

STAIRS

TEL

TEL

CL

SIGN

SH

STOR

A&MM

MECH

RM

UNEXCAVATED

EC

ELEC

CL

HAC

CORR

HAC

STOR

STAIRS

PHARMACY

CACHE

STOR MECH

MECH

SHAFT

STAIRS

ELEC

UNEXCAVATED

EQ

STOR

ELEVATOR

ELEV. M/C

ROOM

MECH

PIT

POLICE TRAINING

ROOM

STAIRS

MECHANICAL

ROOM

HVAC

SHOP336

SF

OFFICE OFFICE OFFICE OFFICE OFFICE DATA

PANDEMIC

CORR

STOR

STOR

KITCHEN

STORAGE VCS

DINING RM VCS

17B

LOCKER ROOM

VESTIBULE

17A

TOILET ROOM

MENS

STORAGE

A&MM

STORAGE

A&MM

HSK

ROOM

COMPUTER

RM

CANTEEN

OFFICE

STORAGE

VCS

FD

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

KEY PLAN

3/

/2

3:

:4

P

M CORRECT AIR CONDITIONING

DEFICIENCIES IN BIOMEDICAL

SHOP AND MAILROOM

503-17-104

JG TP

JAMES E. VAN ZANDT MEDICAL CENTER

ALTOONA, PA 16602

A002

BASEMENT - CONTRACTOR WORK PATH

PLAN

MARCH 27, 2018

14-

BID DOCUMENTS

NORTH

TRUE NORTH

PROJECT

1" = 20'-0"

BASEMENT - CONTRACTOR WORK PATH PLAN

WORK AREA

BIOMED SHOP 31

MAIL ROOM MAS 29

CONTRACTOR(S) TO HAVE FULL ACCESS TO

FREIGHT ELEVATOR.

ELEVATOR IS ACCESSIBLE THROUGH THE

ON GRADE ENTRANCE AT SECOND FLOOR

RECEIVING W203 AND WAREHOUSE W202.

CONTRACTOR(S) PRIMARY STAGING AREA

TO BE LOCATED IN / AT THE PARKING

SPACE AT THE SOUTH END OF BUILDING 2.

NO STORAGE OF MATERIALS IS ALLOWED

IN BUILDING 1 OR IN THE MAILROOM OR IN

THE BIOMEDICAL SHOP.

LEGEND:

CONTRACTOR'S PRIMARY ENTRANCE/PATHWAY

CONTRACTOR(S) SHALL BE PERMITTED TO

PARK IN THIS LOT AT OR NEAR THE END OF

THIS ROW.

PARTIAL SITE MAP (No Scale)

BUILDING 2

BUILDING 1 (MAIN HOSPITAL)

8' - 0"

7' - 0"

8' - 0"

7' - 6"

8' - 0"

STOR A&MM

BIO-MED SHOP

EQ STOR

31A

MAIL ROOM MAS

MECH RM

ELEV

E02

OFFICE

29A

STORAGE MAS

LOBBY

27A

CORR

CORR

47A

STAIRS

S00

MECH RM ENG SVC

MECH RM ENG SVC

VESTIBULE

LOCKER ROOM

17B

SHR RM

16B

MENS TOILET ROOM

17A

STORAGE VCS

ELEV

E00

ELEV

E00A

ELEV

E00B

KITCHEN

TEL

42A

STAIRS

S02

TEL CL

42B

SIGN SH

CHIEF M&R OFFICE

ELEC SHOP

CORR

47B

LINE OF VERTICAL CEILING SOFFIT

INSTALL ACOUSTIC CEILING TILE AT

VERTICAL EDGE TO MATCH EXISTING

INSTALLATIONS. (TYPICAL)

8' - 0"

7' - 0"

8' - 0"

NEW CEILING GRID AND TILE TO BE INSTALLED

AS CLOSE TO THE EXISTING ALIGNMENT AS

POSSIBLE TO REDUCE THE MOVEMENT AND

RELOCATION OF SPRINKLER HEADS OR OTHER

CEILING MOUNTED DEVICES.

8' - 0"

WIRE HANGERS

DOUBLE WEB BEAM

LAY-IN ACOUSTICAL TILE DOUBLE WEB CROSS TEE

SUPPLY AIR DIFFUSER

RETURN AIR GRILLE

UNIT VENTILATOR/ CABINET HEATER

RADIANT CEILING PANEL

RECESSED LIGHT FIXTURE

SURFACE MOUNTED LIGHT FIXTURE

EXIT SIGN

CEILING MOUNTED OCCUPANCY SENSOR

REFLECTED CEILING PLAN SYMBOL LEGEND

2' X 4' LAY-IN ACOUSTICAL TILE CEILING SYSTEM.

SEE DRAWING NOTES FOR SPECIFIC TYPE

GYPSUM BOARD BULKHEAD/ SUSPENDED GYPSUM

BOARD SYSTEM

CEILING/ BULKHEAD HEIGHT A.F.F.

CURTAIN TRACK.

2' X 2' LAY-IN ACOUSTICAL TILE CEILING SYSTEM.

SEE DRAWING NOTES FOR SPECIFIC TYPE

CT

GENERAL NOTES:

REFLECTED CEILING PLAN SYMBOL LEGEND

X' - X"

1. REFLECTED CEILING PLANS SHOW CEILING MOUNTED ITEMS ONLY. ADDITIONAL

WALL MOUNTED LIGHTING, HVAC ITEMS, EXIT SIGNS, ETC. ARE INDICATED ON

INDIVIDUAL ELECTRICAL AND HVAC FLOOR PLAN SHEETS.

UV CUH

RP

OS

SEMI-RECESSED SPRINKLER HEAD

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

KEY PLAN

3/

/2

3:

:4

P

M CORRECT AIR CONDITIONING

DEFICIENCIES IN BIOMEDICAL

SHOP AND MAILROOM

503-17-104

JG TP

JAMES E. VAN ZANDT MEDICAL CENTER

ALTOONA, PA 16602

A130

BASEMENT CEILING PLANS

MARCH 27, 2018

14-

BID DOCUMENTS

NORTH

TRUE NORTH

PROJECT

1/8" = 1'-0"

00-BASEMENT REFLECTED CEILING PLAN

3" = 1'-0"

Acoustical Ceiling Tile Install Detail

GENERAL NOTES:

1. IN MAIL ROOM MAS 29, REMOVE EXISTING CEILING TILE AND GRID AS NECESSARY TO ALLOW FOR MEP WORK.

LIGHT FIXTURES TO REMAIN CONNECTED AND LOCATED AS IS. RE-INSTALL GRID AFTER COMPLETION OF MEP WORK. GRID SHALL BE RETURNED TO PRE-PROJECT CONDITIONS. RE-USE EXISTING ACOUSTIC CEILING TILE. REPLACE ANY DAMAGED TILES AS NECESSARY.

2. IN OFFICE 29A, REMOVE ACOUSTIC CEILING TILE & GRID. LIGHT FIXTURES TO REMAIN CONNECTED AND LOCATED AS-IS.

INSTALL NEW ACOUSTIC CEILING TILE AND GRID IN OFFICE 29A AFTER MEP WORK HAS BEEN COMPLETED.

CEILING TILE AND GRID TO BE ARMSTRONG FINE FISSURED 1810 TILE WITH PRELUDE XL GRID AS DIRECTED IN SPECIFICATIONS. TILE AND GRID TO BE WHITE.

5. IN BIO-MED SHOP 31, REMOVE ACOUSTIC CEILING TILE & GRID. UNDER BID ITEM 1, INSTALL NEW ACOUSTIC CEILING TILE AND GRID IN BIO-MED SHOP 31 AFTER MEP WORK HAS BEEN COMPLETED. NEW CEILING TILE AND GRID TO BE ARMSTRONG FINE FISSURED 1810 TILE WITH PRELUDE XL GRID AS DIRECTED IN SPECIFICATIONS. TILE AND GRID TO BE WHITE. UNDER BID ALTERNATE 1, REINSTALL THE EXISTING ACCOUSTIC CEILING TILE AND GRID. GRID SHALL BE RETURNED TO PRE-PROJECT CONDITIONS. RE-USE EXISTING ACOUSTIC CEILING TILE. REPLACE ANY DAMAGED TILES AS NECESSARY.

6. IN EQUIPMENT STORAGE ROOM 31A, DEMOLISH EXISTING CEILING. AFTER COMPLETION OF MEP WORK, INSTALL NEW TILE AND GRID.

CEILING TILE AND GRID TO BE ARMSTRONG FINE FISSURED 1810 TILE WITH PRELUDE XL GRID AS DIRECTED IN SPECIFICATIONS. TILE AND GRID TO BE WHITE.

7. CONTRACTOR TO APPLY TOUCH UP PAINT TO WORK AREAS AS NEEDED AFTER COMPLETION OF OTHER WORK. PAINT MANUFACTURER, COLOR, FINISH, ETC.

TO MATCH EXISTING ADJACENT AREAS OR AS APPROVED BY THE CONTRACTING OFFICER'S REPRESENTATIVE ASSIGNED TO THIS PROJECT.

8. REFER TO HVAC AND ELECTRICAL DRAWINGS FOR EXACT LOCATIONS AND QUANTITIES OF LIGHT FIXTURES, DIFFUSERS, RETURN AIR GRILLES, ETC.

ALL MAILROOM EQUIPMENT IS INTENDED TO REMAIN IN PLACE

THROUGH THE DURATION OF CONSTRUCTION. THE CONTRACTOR

SHALL PROVIDE MEANS TO PROTECT THE MAILROOM EQUIPMENT

INCLUDING IMPACT PROTECTION IN THE FORM OF HEAVY WEIGHT

CORRUGATED CARDBOARD OR FOAM AND INCLUDING DUST

PROTECTION IN THE FORM OF PLASTIC SHRINK WRAP. ADDITIONAL

PROTECTION METHODS SHALL BE REVIEWED AND APPROVED BY

THE COR PRIOR TO INSTALLATION.

DRAWING SYMBOLS

SYMBOLS DESCRIPTION

PIPELINE ABBREVIATIONS HVAC SYMBOLS

EQUIPMENT TAG ABBREVIATIONS

DESCRIPTIONSYMBOLS

PIPELINE SYMBOLS

DOUBLE LINE SHEETMETAL

SINGLE LINE - SHEET METAL

DESCRIPTIONSYMBOLS

DUAL TEMPERATURE WATER RETURN

DUAL TEMPERATURE WATER SUPPLY

HOT WATER HEATING RETURN

HOT WATER HEATING SUPPLY

INVERTED ECCENTRIC REDUCER

(VENTURI FLOW STATION)

TWO-WAY MODULATING

THREE-WAY MODULATING CONTROL VALVE

SAFETY VALVE OR PRESSURE RELIEF

PRESSURE REDUCING VALVE

BALANCING COCK

WATER FLOW MEASURING DEVICE

PIPING TURNED DOWN

TWO-WAY CONTROL VALVE

MOTORIZED VALVE

AUTOMATIC AIR VENT

PIPING TURNED UP

FUNNEL DRAIN

CONTROL VALVE

A

M

MANUAL AIR VENT

(TWO POSITION TYPE)

AQUASTAT

PRESSURE TAP

THERMOMETER

STRAINER

PRESSURE GAUGE

UNION

ECCENTRIC REDUCER

MANUAL VOLUME CONTROL DAMPER (VD)

RISE/DROP IN DUCTWORK

(ARROW SHOWS DIRECTION OF DROP)

SMOKE DAMPER/DETECTOR

PANEL IN DUCT AND CEILING)

EXHAUST AIR DUCT DN

SUPPLY AIR DIFFUSER

ACCESS DOOR ON SIDE OF DUCT

EXHAUST REGISTER

RETURN AIR REGISTER

ACCESS DOOR ON BOTTOM OF DUCT

DETECTOR BY E.C. DAMPER BY H.C.

FIRE DAMPER AT FIRE WALL (PROVIDE ACCESS

OR HORIZONTAL DUCT ABOVE CEILING (PROVIDE

FIRE DAMPER IN VERTICAL DUCT THRU FLOOR

ACCESS PANEL IN DUCT AND WALL OR CEILING)

SUPPLY AIR REGISTER (DUCT OR WALL)

EXHAUST/RETURN AIR REGISTER (DUCT OR WALL)

COMBINATION FIRE/SMOKE DAMPER

MOTORIZED DAMPER

SUPPLY DUCT DN

RETURN AIR DUCT DN

EXHAUST AIR DUCT UP

RETURN AIR DUCT UP

SUPPLY DUCT UP

ROUND SUPPLY, RETURN OR

OVAL SUPPLY, RETURN OR

RECTANGULAR SUPPLY, RETURN OR

DIRECTION OF AIR FLOW)

DUCT W/O TURNING VANES

DUCT MOUNTED SMOKE

BY EC, INSTALLED BY HC

RELIEF DUCT WIDTH (SHOWN)XDEPTH

RELIEF DUCT WIDTH (SHOWN)XDEPTH

LOW LOSS TAKE OFF (ARROW INDICATES

RADIUS ELBOW (DUCT WIDTH 17" AND LOWER)

(ARROW INDICATES AIR FLOW DIRECTION)

BOOT CONNECTION WITH MANUAL VD

DUCT W/TURNING VANES (DUCT WIDTH OVER 18")

WALL SWITCH

DUCT/SPACE STATIC PRESSURE SENSOR

DETECTOR PROVIDED

CONICAL SPIN-IN FITTING

24"X24"24"X24"

12"X12"

SD

S

WS

M

AD

REFRIGERANT LINE

REFRIGERANT SUCTION

RL

RS

HWHS

HWHR

DTS

DTR

THERMAL VAV DIFFUSERTF

CD CONDENSATE DRAIN LINE

MPS MEDIUM PRESSURE STEAM SUPPLY

MPCR MEDIUM PRESSURE CONDENSATE RETURN

PUMPED CONDENSATEPC

HRS ENERGY (HEAT) RECOVERY SUPPLY

HRR ENERGY (HEAT) RECOVERY RETURN

NAME PIPE TO BE REMOVED

NAME EXISTING PIPING TO REMAIN

TEE- OUTLET

SIDE CONNECTION

CAPPED OUTLET

TEE - OUTLET UP

12"X12"

12"/12"

RELIEF VALVE

BUTTERFLY VALVE

PLUG VALVE

GATE VALVE

GLOBE VALVE

PIPE BREAK (SINGLE LINE)

DIRECTION OF FLOW

FLEXIBLE CONNECTION

BACKFLOW PREVENTION DEVICE

DUCT END CAP

24X12

SQUARE ELBOW WITH

TURNING VANES

RADIUS TURN ELBOW

RETURN CROSS

SECTION DN

EXHAUST CROSS

SECTION UP

SUPPLY DUCT

CROSS SECTION DN

RETURN CROSS

SECTION UP

CROSS SECTION UP

SUPPLY DUCT

ROUND DUCT SIZE (DIAMETER)

FLEXIBLE DUCT (DIAMETER SIZE)

DUCT SIZE (WIDTH X DEPTH)

24"Ø

DUCT W/ TURNING VANES

CONDENSER WATER RETURN

CONDENSER WATER SUPPLYCWS

CWR

CTD COOLING TOWER DRAIN LINE

BALL VALVE

(HINGED & GASKETED)

(HINGED & GASKETED)

FD

F/SD

FDFD

LPS LOW PRESSURE STEAM SUPPLY

LPCR LOW PRESSURE CONDENSATE RETURN

HPS HIGH PRESSURE STEAM SUPPLY

HPCR HIGH PRESSURE CONDENSATE RETURN

BACKDRAFT DAMPER

B

DUCT/WALL TEMPERATURE SENSOR, ELECTRICT

24"Ø

12"Ø

DRAWING NUMBER WHERE DRAWN

H200

SECTION LETTER

DRAWING NUMBER WHERE DRAWNH100

DETAIL NUMBER

CONNECT TO EXISTING AT THIS POINT

DEMO/REMOVE TO THIS POINT

EQUIPMENT NUMBER1

AHU POWERED EQUIPMENT

EQUIPMENT NUMBER1

RHC NON-POWERED EQUIPMENT

CD-#

AIRFLOW QUANTITY

DIFFUSER/REGISTER/GRILLE TYPE

STAINLESS STEEL DUCTWORK

DUCT/WALL TEMPERATURE SENSOR, ELECTRICT

ACC AIR COOLED CHILLER

ACCU AIR COOLED CONDENSING UNIT

ACCUM ACCUMULATOR

AHU AIR HANDLING UNIT

ASHP AIR SOURCE HEAT PUMP

B BOILER

BB BASEBOARD HEATER

BD BAROMETRIC DAMPER

BDD BACK DRAFT DAMPER

CC CHILLED WATER COOLING COIL

CD CONDENSATE DRAIN

CIRC CIRCULATOR

CMPR COMPRESSOR

CONV CONVECTOR

CP CONDENSATE PUMP

CUH CABINET UNIT HEATER

DC DRY COOLER

EF EXHAUST FANS

ER EXHAUST REGISTER

ERW EXHAUST REGISTER WALL

ET EXPANSION TANK

ECUH ELECTRIC CABINET UNIT HEATER

EUH ELECTRIC UNIT HEATER

EWH ELECTRIC WALL HEATER

EVAP EVAPORATOR

FT FINNED TUBE RADIATION

FCU FAN COIL UNIT

FPB FAN POWERED BOX

FU FURNACE

GIV GRAVITY INTAKE VENTILATOR

GRV GRAVITY ROOF VENTILATOR

H HUMIDIFIER

HC HOT WATER HEATING COIL

HUH HORIZONTAL UNIT HEATER

P PUMP

PTAC PACKAGED TERMINAL AIR CONDITIONING UNIT

RG RETURN GRILLE

RR RETURN REGISTER

RAG RETURN AIR GRILLE

RCP RADIANT CEILING PANEL

RTU ROOF TOP UNIT

SF SUPPLY FAN

SSAC SPLIT SYSTEM AIR CONDITIONING UNIT

SSDC SECURITY SUPPLY DIFFUSER CEILING

SSEF SECURITY SMOKE EXHAUST FAN

SSGW SECURITY SUPPLY SUPPLY GRILLE WALL

SLSD SUPPLY LINEAR SLOT DIFFUSER

UH UNIT HEATER

UV UNIT VENTILATOR

UCD UNDER CUT DOOR

VAV VARIABLE AIR VOLUME

DRAWING KEYNOTE - DEMOLITION

DRAWING KEYNOTE - PLAN / ELEVATION NEW WORK

CONSULTANTS:

Drawing Title

Approved: Project Director

Project Title:

Location:

Date: Checked: Drawn:

Drawing Number

Building Number

Project Number

Office of Construction and Facilities Management

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

FULLY SPRINKLERED

A

B

C

D

E

F

6 " o n e e ig h th i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h o n e f o o t th re e i n c h e s o n e f o o t

209 SANDUSKY STREET

PITTSBURGH, PA 15212

PH: 412.287.7333

www.ae-works.com

AE WORKS PROJECT NUMBER:

ARCHITECTS/ENGINEERS:SEAL

Revision# Date

3/

/2

3:

:4

P

M CORRECT AIR CONDITIONING

DEFICIENCIES IN BIOMEDICAL

SHOP AND MAILROOM

503-17-104

JG JA

JAMES E. VAN ZANDT MEDICAL CENTER

ALTOONA, PA 16602

H001

HVAC SYMBOLS, ABBREVIATIONS AND

GENERAL NOTES

MARCH 27, 2018

17029

BID DOCUMENTS

SR SERVICE RECEPTOR

SS SOIL STACK

ST PR STATIC PRESSURE

ST STL STAINLESS STEEL

STD STANDARD

STER STERILIZER

STL STEEL

STOR STORAGE

STR STRAINER

STRUCT STRUCTURAL

SUSP SUSPENDED

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

SYM SYMMETRICAL TOP

T TOP

TA THROWAWAY

TAN TANGENT

TC TELECOMMUNICATIONS

CONTRACTOR

TCV TEMPERATURE CONTROL VALVE

TDV TRIPLE DUTY VALVE

TEL TELEPHONE

TEMP TEMPERATURE

TER TERRAZZO

TG TONGUE & GROOVE

TH THERMOMETER

THRES THRESHOLD

TR TEMPERATURE RISE

TRANS TRANSITION

TRANSR TRANSFORMER

TSTAT THERMOSTAT

TV TURNING VANES OR TELEVISION

TYP TYPICAL

UC UNDER CABINET OR UNDER CUT

UFD UNDER FLOOR DUCT

UG UNDERGROUND

UH UNIT HEATER

UL UNDERWRITER'S LABORATORIES

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

VAL VALVE

VD VOLUME DAMPER

VENT VENTILATION

VERT VERTICAL

VFS VENTURI FLOW STATION

VIF VERIFY IN FIELD

VL VENT LINE

VR VAPOR RETARDER

VS VENT STACK

VTR VENT THROUGH ROOF

W WATT

W/ WITH

W/O WITHOUT

WB WET BULB

WC WALL COVERING

WCL WATER CLOSET

WD WOOD

WF WIDE FLANGE

WFMD WATER FLOW MEASURING DEVICE

WG WALL GUARD OR WATER GAUGE

WHCH WHEEL CHAIR

WIN WINDOW

WMS WIRE MESH SCREEN

WP WEATHERPROOF

WPS WALL PROTECTION SYSTEM

WSCT WAINSCOT

WT WINDOW TREATMENT

WTD WATER TEMPERATURE DROP

WWF WELDED WIRE FABRIC

X DEMO

XN TO BE RELOCATED / NEW LOCATION

XR EXISTING TO REMAIN

ZVB ZONE VALVE BOX

ZVC ZONE VALVE CABINET

LB POUND

LDB LEAVING DRY BULB

LED LIGHT EMITTING DIODE

LF LINEAR FEET

LIN LINEAR

LOC LOCATION OR LOCATE

LPT LOW POINT

LSDC LINEAR SUPPLY DIFFUSER CEILING

LT LIGHT

LTG LIGHTING

LV LOW VOLTAGE

LVR LOUVER

LWB LEAVING WET BULB

LWC LINEAR WOOD CEILING

LWT LEAVING WATER TEMPERATURE

MAN MANUAL

MAT MIXED AIR TEMPERATURE

MATL MATERIAL

MAV MANUAL AIR VENT

MAX MAXIMUM

MBH ONE THOUSAND BTU / HOUR

MC MECHANICAL CONTRACTOR

MC METAL CLAD CABLE

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MEMB MEMBRANE

MET METAL

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MO MASONRY OPENING

MOD MOTOR OPERATED DAMPER

MONO MONOLITHIC

MTD MOUNTED

MTG HT MOUNTING HEIGHT

MTL METAL

MTLH METAL HALIDE

MTR MOTOR

MTS MANUAL TRANSFER SWITCH

MV MEDIUM VOLTAGE

N/A NOT APPLICABLE

NEC NATIONAL ELECTRIC CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NUMBER OR NORMALLY OPEN

NOM NOMINAL

NTS NOT TO SCALE

O OXYGEN

OA OUTSIDE AIR

OBD OPPOSED BLADE DAMPER

OC ON CENTER

OD OUTSIDE DIAMETER

OPER OPERATED

OPNG OPENING

OPP OPPOSITE

ORD OVERFLOW ROOF DRAIN

PB PULL BOX

PC PLUMBING CONTRACTOR

PD PUMP DISCHARGE

PG PRESSURE GAUGE WITH COCK

PL PROPERTY LINE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PNL PANEL

PR PAIR

PRD PRESSURE DIFFERENTIAL VALVE

PRELIM PRELIMINARY

PRT PRESSURE TAP

PRV PRESSURE REDUCING VALVE

PT PAINT OR POTENTIAL

TRANSFORMER

RO ROUGH OPENING

QT QUARRY TILE

R RADIUS

RA RETURN AIR / RELIEF AIR

RB RUBBER BASE

RC REMOVE COMPLETELY

RD ROOF DRAIN

RE RELOCATE EXISTING

REC RECESSED

RECPT RECEPTACLE

REF REFERENCE

REFL REFLECTOR

REG REGISTER

REINF REINFORCING

REM REMOVE

REQD REQUIRED

RET RETURN

REV REVISE

REX REMOVE EXISTING

RF RESILIENT FLOOR

RFI REQUEST FOR INFORMATION

RGS RIGID GALVANIZED STEEL CONDUIT

RH ROOF HATCH

RM ROOM

RN REMOVE AND REPLACE WITH NEW

RR REMOVE AND REPLACE

RS RAPID START

RV RELIEF VALVE

RWC RAIN WATER CONDUCTOR

SA SUPPLY AIR

SAN SANITARY SEWER ABOVE GROUND

SAN-BXR SANITARY SEWER - BURIED

EXISTING TO REMAIN

SAN-XR SANITARY SEWER ABOVE GROUND -

EXISTING TO REMAIN

SCHED SCHEDULE

SD SMOKE DAMPER OR SMOKE

DETECTOR

SDISP SOAP DISPENSER

SF SQUARE FOOT

SHT SHEET

SHT MTL SHEET METAL

SHTG SHEATHING

SIM SIMILAR

SM SURFACE MOUNTED

SNC SANITARY NAPKIN CABINET

SND SANITARY NAPKIN DISPOSER

SP STANDPIPE OR STATIC PRESSURE

SPC SPECIMEN PASS-THRU CABINET

SPEC SPECIFICATIONS

SPS STATIC PRESSURE SENSOR

EIFS EXTERIOR INSULATION AND

FINISHING SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEC CAB ELECTRICAL CABINET

ELEV ELEVATOR

EMER EMERGENCY

ENCL ENCLOSURE

ENTR ENTRANCE

EO ELECTRICAL OUTLET

EQ EQUAL

EQUIP EQUIPMENT

ETR EXISTING TO REMAIN

EWB ENTERING WET BULB

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

EX EXAUST AIR

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

XP EXPLOSION PROOF

F/S FIRE / SMOKE DAMPER

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FAT FINAL AIR TEMPERATURE

FB FIRE BLANKET

FC FLEXIBLE CONNECTION OR

FOOTCANDLE

FD FLOOR DRAIN OR FIRE DAMPER

FDN FOUNDATION

FDV FIRE DEPARTMENT VALVE

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FH FIRE HOSE

FHC FIRE HOSE CABINET

FHP FULL HEIGHT PARTITION

FHV FIRE HOSE VALVE

FIN FINISH

FIXT FIXTURE

FL FLOW LINE

FLA FULL LOAD AMPERES

FLASH FLASHING

FLEX FLEXIBLE

FLG FLANGE

FLG C FLANGE CONNECTION

FLR FLOOR

FLUOR FLUORESCENT

FP FIRE PROOFING

FRMG FRAMING

FS FLOOR SINK

FSTOP FIRESTOPPING

FT FOOT / FEET

FT HD FEET OF HEAD

FTC FOOTCANDLES

FTG FOOTING

FUR FURRING

G GAS OR ELECTRICAL GROUND

GA GAUGE

GAL GALLONS

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GEN GENERATOR

GENL GENERAL

GFCI GROUND FAULT CIRCUIT

INTERRUPTOR

GL GLASS

GLV GLOBE VALVE

GND GROUND

GPM GALLONS PER MINUTE

GR GRADE

GRAV GRAVITY

GRD BM GRADE BEAM

GV GATE VALVE

GWB GYPSUM BOARD

H HIGH

HB HOSE BIB

HC HEATING CONTRACTOR

HDCP HANDICAP

HDR HEADER

HDW HARDWARE

HID HIGH INTENSITY DISCHARGE

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HORSE POWER

HPD HIGH PRESSURE DRIP

HPF HIGH POWER FACTOR

HR HANDRAIL

HSKP HOUSEKEEPING

HT HEIGHT

HTG HEATING

HTR HEATER

HV HIGH VELOCITY

HVAC HEATING, VENTILATING, AIR

CONDITIONING

HW HOT WATER

HWD HARD WOOD

HWR HOT WATER RETURN

HWS HOT WATER SUPPLY

HWS&R HOT WATER SUPPLY AND RETURN

HZ HERTZ

ID INSIDE DIAMETER

IER INVERTED ECCENTRIC REDUCER

IG ISOLATED GROUND

IME INSULATED METAL ENCLOSURE

IN INCH

INCAND INCANDESCENT

INCL INCLUDED

INSUL INSULATION

INT INTERIOR

INTERL INTERLOCK

INV INVERT

ISO ISOLATION

IVS ISOLATED VALVE STATION

J-BOX JUNCTION BOX

JST JOIST

JT JOINT

KO KNOCK OUT

kVA KILOVOLT AMPERE kVAR KILOVAR (REACTANCE) kW KILOWATT kWH KILOWATT HOUR METER

LAT LEAVING AIR TEMPERATURE

LAV LAVATORY

& AND

A AIR (CLINICAL)

AAP ALARM ANNUNCIATOR PANEL

AAV AUTOMATIC AIR VENT

AB ANCHOR BOLT

ABV ABOVE

ACC DR ACCESS DOOR

ACFL ACCESS

ACOUS ACOUSTICAL

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICAN DISABILITIES ACT

ADD ADDENDUM

ADDL ADDITIONAL

ADJ ADJUSTABLE

ADMIN ADMINISTRATION

AFF ABOVE FINISH FLOOR

AFG ABOVE FINISHED GRADE

AFMD AIR FLOW MEASURING DEVICE

AHU AIR HANDLING UNIT

AL ALIGN

ALT ALTERNATE

ALUM ALUMINUM

AMP AMPERE

AP ACCESS PANEL

APC ARCHITECTURAL PRECAST

CONCRETE

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASY ASYMMETRIC

ATC AUTOMATIC TEMPERATURE

CONTROL

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AWT AVERAGE WATER TEMPERATURE

BAT BATTERY

BC BALANCING COCK OR BARE

COPPER

BDD BACKDRAFT DAMPER

BFC BELOW FINISH CEILING

BFE BOTTOM FOOTING ELEVATION

BFG BELOW FINISHED GRADE

BG BUMPER GUARD

BLDG BUILDING

BLKG BLOCKING

BLT BORROWED LIGHT

BLW BELOW

BM BEAM

BO BY OWNER

BOF BY OWNER FUTURE

BOT BOTTOM

BR BRICK

BRG BEARING

BRKR BREAKER

BSMT BASEMENT

BTWN BETWEEN

BUR BUILT UP ROOFING

C CONDUIT

CAB CABINET

CANTL CANTILEVER

CAP CAPACITY

CATV CABLE TELEVISION

CCT CUBICLE CURTAIN TRACK

CCTV CLOSED CIRCUIT TELEVISION

CFH CUBIC FEET / HOUR

CFM CUBIC FEET / MINUTE

CH CHANNEL

CHK V CHECK VALVE

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CHWS&R CHILLED WATER SUPPLY AND

RETURN

CJ CONTROL JOINT

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CL CENTERLINE

CLG CEILING

CLG MTD CEILING MOUNTED

CLR CLR

CMU CONCRETE MASONRY UNIT

CO CLEAN OUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUE / CONTINUOUS

CONTR CONTRACTOR

CONV CONVECTOR

COORD COORDINATE

CORR CORRIDOR

CPT CARPET OR CONTROL POWER

TRANSFORMER

CT CERAMIC TILE

CTR CENTER

CU COPPER

CV CONTROL VALVE

CW COLD WATER

D DEPTH OR DEEP

DB DRY BULB

dB DECIBEL

DCW DOMESTIC COLD WATER

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAILS

DF DRINKING FOUNTAIN

DHW DOMESTIC HOT WATER

DIA DIAMETER

DIAG DIAGONAL OR DIAGRAM

DIFF DIFFUSER

DIM DIMENSION

DISC DISCONNECT

DISCH DISCHARGE

DISP DISPENSER

DIST DISTRIBUTION

DIV DIVISION

DL DOWN LIGHT

DN DOWN

DP DISTRIBUTION PANEL

DPR DAMPER

DR DRAIN

DS DOWNSPOUT

DWG DRAWING

DX DIRECT EXPANSION

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EC ELECTRICAL CONTRACTOR

EDB ENTERING DRY BULB

EF EXHAUST FAN

ABBREVIATION LEGEND HVAC GENERAL NOTES

1 NOT ALL SYMBOLS ARE NECESSARILY USED.

2 COORDINATE FINAL LOCATIONS OF DIFFUSERS AND GRILLES WITH ARCHITECTURAL REFLECTED CEILING PLANS.

3 DRAWINGS ARE DIAGRAMMATIC. CONTRACTOR TO FIELD VERIFY DUCT AND PIPE ROUTING AND COORDINATE INTERFERENCE BETWEEN TRADES PRIOR TO

INSTALLATION.

4 ROOF OPENINGS, FLASHING, AND COUNTER FLASHING BY GENERAL CONTRACTOR. LOCATION OF OPENINGS BY HEATING CONTRACTOR.

5 DUCTWORK TO BE INSTALLED TIGHT TO UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE.

6 PROVIDE ALL MATERIALS, EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE

DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE.

7 CONTRACT DOCUMENT DRAWINGS FOR MECHANICAL WORK ARE DIAGRAMMATIC AND ARE INTENDED TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY.

CONTRACTOR SHALL BE RESPONSIBLE TO FIELD SURVEY ACTUAL SITE CONDITIONS AND ACCOMODATE ACTUAL SITE CONDITIONS AS PART OF SCOPE OF WORK AT

NO COST TO OWNER.

8 INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, CONTRACT DOCUMENTS, APPLICABLE BUILDING, STATE AND LOCAL CODES, SEISMIC REQUIREMENTS, ENERGY CODES AND INSURANCE UNDERWRITER REQUIREMENTS.

9 COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, CIVIL AND ELECTRICAL WORK, ETC. SHOWN ON OTHER CONTRACT

DOCUMENT DRAWINGS.

10 MAINTAIN A MINIMUM OF 6'-8" CLEARANCE TO UNDERSIDE OF PIPES, DUCTS, CONDUITS, SUSPENDED EQUIPMENT, SUPPORTS, ETC., THROUGHOUT ACCESS ROUTES IN

MECHANICAL ROOMS.

11 ALL TESTS SHALL BE COMPLETED AND ACCEPTED BY THE INSPECTOR BEFORE ANY MECHANICAL EQUIPMENT OR PIPING INSULATION IS APPLIED.

12 LOCATE ALL TEMPERATURE, PRESSURE AND FLOW MEASURING DEVICES IN ACCESSIBLE LOCATIONS WITH STRAIGHT SECTION OF PIPE OR DUCT UPSTREAM AND

DOWNSTREAM, AS RECOMMENDED BY THE MANUFACTURER FOR ACCURACY.

13 TESTING ADJUSTING AND BALANCING (TAB) AGENCY SHALL BE A MEMBER OF THE ASSOCIATED AIR BALANCING COUNCIL (AABC) OR THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). TAB FIRM SHALL HAVE A MINIMUM OF 5 YEARS EXPERIENCE ON SIMILAR PROJECTS. PERFORM TAB IN ACCORDANCE WITH THE REQUIREMENTS OF THE TAB PROCEDURAL STANDARD RECOMMENDED BY THE TAB TRADE ASSOCIATION THAT APPROVED THE TAB FIRM'S QUALIFICATIONS.

14 WHERE TWO OR MORE ITEMS OF THE SAME TYPE OF EQUIPMENT ARE REQUIRED, THE PRODUCTS OF A SINGLE MANUFACTURER SHALL BE USED.

15 COORDINATE ALL FINAL EQUIPMENT CONNECTIONS WITH THE MANUFACTURERS' CERTIFIED DRAWINGS. COORDINATE AND PROVIDE ALL DUCTWORK AND PIPING TRANSITIONS REQUIRED FOR FINAL EQUIPMENT CONNECTIONS TO FURNISHED EQUIPMENT. FIELD VERIFY AND COORDINATE ALL DUCTWORK AND PIPING DIMENSIONS

BEFORE FABRICATION.

16 ALL CONTROL WIRE AND CONDUIT SHALL COMPLY WITH THE NATIONAL ELECTRIC CODE, DIVISION 26 OF THE SPECIFICATIONS, ALL LOCAL CODES, AND OWNER'S

INSURANCE UNDERWRITER REQUIREMENTS.

17 THE LOCATIONS AND SIZES OF ALL ITEMS SHOWN ON THE DRAWINGS OR CALLED FOR IN THE SPECIFICATIONS THAT ARE NOT DEFINITELY FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONS AND SIZES NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS SHALL BE DETERMINED BY THE PROJECT SITE CONDITIONS AND SHALL HAVE THE APPROVAL OF THE ENGINEER BEFORE BEING INSTALLED. DO NOT SCALE DRAWINGS.

18 PLAN DRAWINGS AND SECTIONS CUTS WHICH SPECIFICALLY IDENTIFY SERVICE ROUTE OFFSETS, ELEVATION CHANGES, OBSTRUCTIONS, ACCESS DOORS, BALANCING DEVICES, ETC. ARE SHOWN FOR CLARITY WHERE SPECIFIC KNOWN CONDITIONS EXIST. MECHANICAL CONTRACTOR SHALL COORDINATE EQUIPMENT, DUCTWORK, AND PIPING ROUTINGS WITH ALL OTHER TRADES. REQUIREMENTS NOT SPECIFICALLY IDENTIFIED SHALL NOT BE INTERPRETED AS EXCLUSION FROM CONTRACTOR'S SCOPE OF WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR ACTUAL SITE CONDITIONS AND SHALL INCLUDE SUCH CONDITIONS IN SCOPE OF WORK AT NO

ADDITIONAL COST TO THE OWNER.

19 ALL MISCELLANEOUS STEEL REQUIRED TO ENSURE PROPER INSTALLATION AND SUPPORT OF MECHANICAL WORK AS SHOWN IN DETAILS FOR PIPING, DUCTWORK AND EQUIPMENT (UNLESS OTHERWISE NOTED) SHALL BE FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.

20 ALL EQUIPMENT, PIPING, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED, SPECIFIED AND AS REQUIRED TO PROVIDE A VIBRATION FREE INSTALLATION.

21 ALL OPENINGS IN FIRE RATED WALLS AND SMOKE PARTITIONS DUE TO DUCTWORK, PIPING, CONDUIT, ETC., SHALL BE FIRE STOPPED WITH APPROVED FIRESTOPPING

MATERIALS.

22 REFER TO TYPICAL DETAILS FOR DUCTWORK, PIPING AND EQUIPMENT INSTALLATION.

23 UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS WITH TOP AT 48" ABOVE FINISHED FLOOR IN ACCORDANCE WITH ADA REQUIREMENTS. NOTIFY THE ENGINEER OF ANY ROOMS WHERE THE ABOVE LOCATION CAN NOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION. COORDINATE FINAL LOCATIONS

WITH OWNER.

24 LOCATE ALL MECHANICAL EQUIPMENT (VAV BOXES, CABINET HEATERS, UNIT HEATERS, ETC.,) FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS, FILTERS, CONTROLS AND VALVING. DO NOT LOCATE FAN POWERED VAV BOXES ABOVE LIGHTING FIXTURES.

25 PROVIDE FLEXIBLE CONNECTIONS IN ALL DUCTWORK SYSTEMS (SUPPLY, RETURN AND EXHAUST) CONNECTED TO FANS AND OTHER EQUIPMENT WHICH REQUIRE VIBRATION ISOLATION. FLEXIBLE CONNECTIONS SHALL BE PROVIDED AT THE POINT OF CONNECTION TO THE EQUIPMENT UNLESS OTHERWISE INDICATED.

26 ALL LOUVERS SHALL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR (UNLESS OTHERWISE NOTED). GENERAL CONTRACTOR SHALL COORDINATE SIZES, LOCATIONS, AND CONNECTIONS WITH MECHANICAL CONTRACTOR. DUCTWORK CONNECTIONS TO LOUVERS SHALL BE FURNISHED AND INSTALLED BY

MECHANICAL CONTRACTOR.

27 PROVIDE AN AIR VENT AT THE HIGH POINT OF EACH DROP IN HYDRONIC WATER PIPING SYSTEMS. ALL PIPING SHALL SLOPE TO LOW POINTS. PROVIDE HOSE END

DRAIN VALVES AT THE BOTTOM OF ALL RISERS AND LOW POINTS.

28 INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES AND OTHER APPURTENANCES REQUIRING ACCESS ARE ACCESSIBLE.

29 ALL ISOLATION VALVES SHALL BE IN LOCATION AND ELEVATION WHICH ALLOWS FOR EQUIPMENT AND BRANCH PIPING REMOVAL, WHILE MAINTAINING SERVICE

UPSTREAM OF THE ISOLATION VALVE.

30 ALL BALANCING VALVES AND ISOLATION VALVES USED TO ADJUST FLOW RATES SHALL BE PROVIDED WITH POSITIONS INDICATORS AND MAXIMUM ADJUSTABLE

STOPS (MEMORY STOPS).

31 ALL ISOLATION VALVES (EXCEPT CONTROL VALVES), STRAINERS, AND PIPING SPECIALTIES SHALL BE FULL LINE SIZE BEFORE REDUCING SIZE TO MAKE CONNECTIONS

TO EQUIPMENT AND CONTROLS.

32 MECHANICAL JOINTS SUCH AS UNIONS, FLANGES, OR THREADED FITTINGS SHALL BE INSTALLED AT EACH EQUIPMENT CONNECTION, IN BYPASSES, AT FLOOR PENETRATIONS, AT CONTROL DEVICES, AND IN LONG PIPE RUNS (100 FEET OR MORE) TO PERMIT DISASSEMBLY FOR ALTERATION AND REPAIRS.

33 MEASURE, CUT AND INSTALL PIPE LENGTH ACCURATELY TO MINIMALIZE MISALIGNMENT. INSTALL ALL PIPING WITHOUT FORCING OR SPRINGING.

34 PROVIDE FLEXIBLE CONNECTIONS IN ALL PIPING SYSTEMS CONNECTED TO PUMPS AND OTHER EQUIPMENT WHICH REQUIRE VIBRATION ISOLATION (EXCEPT WATER COILS). FLEXIBLE CONNECTIONS SHALL BE PROVIDED AS CLOSE TO THE EQUIPMENT AS POSSIBLE OR AS INDICATED ON THE DRAWINGS.

35 PROVIDE VIBRATION INSULATION FOR ALL MECHANICAL EQUIPMENT TO PREVENT VIBRATION TRANSMISSION TO BUILDING STRUCTURE.

36 CONCRETE HOUSEKEEPING PADS SHALL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL PROVIDE EQUIPMENT WEIGHTS, SIZES AND LOCATION TO GENERAL CONTRACTOR. MINIMUM CONCRETE PAD THICKNESS SHALL BE IN ACCORDANCE WITH STRUCTURAL DETAILS. PAD

SHALL EXTEND BEYOND THE EQUIPMENT FOOTPRINT A MINIMUM OF 6 INCHES ON EACH SIDE.

37 ALL DUCTWORK, PIPING, AND EQUIPMENT SUPPORTED FROM STRUCTURAL STEEL SHALL BE COORDINATED WITH GENERAL CONTRACTOR. ALL ATTACHEMENTS TO STEEL MEMBERS, BAR JOISTS, TRUSSES, OR JOIST GIRDERS SHALL BE APPROVED BY STRUCTURAL ENGINEER. WELDING TO STRUCTURAL MEMBERS SHALL NOT BE

PERMITTED.

38 MECHANICAL EQUIPMENT, DUCTWORK, AND PIPING SHALL NOT BE SUPPORTED FROM ROOF OR DECK ASSEMBLY. SUPPORTS SHALL ATTACH TO STRUCTURAL

MEMBERS. COORDINATE WITH STRUCTURAL DRAWINGS.

39 PROVIDE MANUFACTURER'S MATCHING ROOF CURBS FOR ALL ROOF MOUNTING EQUIPMENT. COORDINATE ACTUAL ROOF PITCH AND CONSTRUCTION DETAILS WITH GENERAL CONTRACTOR. PROVIDE SLOPED CURBS PER MANUFACTURER'S RECOMMENDATIONS. GENERAL CONTRACTOR SHALL INSTALL ROOF CURBS AND FLASHING

PER ROOFING MANUFACTURER'S INSTALLATION REQUIREMENTS.

40 UNLESS OTHERWISE NOTED, ALL PIPING AND DUCTWORK IF OVERHEAD, TIGHT TO UNDERSIDE OF STRUCTURE OR SLAB, WITH SPACE FOR INSULATION.

41 PROVIDE CHAINWHEEL OPERATORS FOR ALL EXPOSED VALVES MOUNTED GREATER THAN 8'-0" ABOVE FINISHED FLOOR LEVEL. CHAIN SHALL EXTEND

UNOBSTRUCTED TO 7'-0" ABOVE FLOOR LEVEL.

42 ALL PIPING AND DUCTWORK SHALL CLEAR DOORS, WINDOWS, EQUIPMENT CLEARANCES, MAINTENANCE REQUIREMENTS, CODE SETBACKS, ETC. TO ASSURE PROPER

OPERATION, INSPECTION AND MAINTENANCE.

43 ALL VALVES SHALL BE ADJUSTED FOR SMOOTH AND EASY OPERATION.

44 PROVIDE ALL 90 DEGREE SQUARE ELBOWS WITH DOUBLE RADIUS TURNING VANES UNLESS OTHERWISE INDICATED OR SPECIFIED. PROVIDE ACCESS DOORS

UPSTREAM OF ALL ELBOWS CONTAINING TURNING VANES.

45 ALL DUCTS SHALL BE BONDED ACROSS FLEXIBLE CONNECTIONS WITH FLEXIBLE COPPER GROUNDING STRAPS. GROUNDING STRAPS SHALL BE BOLTED OR SOLDERED

TO BOTH THE EQUIPMENT AND THE DUCT.

46 ALL EQUIPMENT SUBMITTALS AND SHOP DRAWINGS REQUIRED BY THE SPECIFICATIONS SHALL BE APPROVED BY THE ENGINEER PRIOR TO PURCHASE, FABRICATION

AND INSTALLATION.

47 ALL HEATING DEVICES AND SURFACES WITH ELEVATED TEMPERATURES WHICH CAN BE ACCESSED OR COME IN CONTACT WITH OWNER PERSONNEL SHALL BE

PROTECTED, INSULATED, OR CONTROLLED TO REMAIN BELOW 120º F.

48 PROVIDE MANUAL VOLUME DAMPERS IN ALL RUN-OUTS TO DIFFUSERS, BRANCH TAKE-OFFS FROM MAIN SUPPLY DUCT, AND IN ALL OTHER AREAS REQUIRED TO

PROVIDE PROPER SYSTEM AIRFLOW BALANCING.

HVAC GENERAL DEMOLITION NOTES

1 THE CONTRACTOR SHALL THOROUGHLY EXAMINE THE SITE PRIOR TO SUBMITTING THEIR BID. DUE TO THE NATURE OF THIS PROJECT AND THE STATE OF THE EXISTING BUILDING, IT IS IMPOSSIBLE TO COMPLETELY RELATE THE SCOPE OF THE DEMOLITION REQUIRED TO THE CONTRACTOR THROUGH THE CONTRACT DOCUMENTS. FAILURE TO VISIT THE SITE WILL NOT RELIEVE THE CONTRACTOR OF THEIR DEMOLITION RESPONSIBILITIES UNDER THIS CONTRACT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE AND COORDINATE THE EXACT EXTENT OF DEMOLITION NECESSARY TO PROVIDE A RENOVATED AND UPGRADED SPACE

TO FACILITATE NEW WORK.

2 INFORMATION REGARDING THE EXISTING CONDITIONS WAS GATHERED FROM AVAILABLE EXISTING DRAWINGS, SURVEY AND CORRESPONDENCE WITH UTILITY, STAFF AND FACILIITES PERSONNEL. THERE ARE NO GUARANTEES AS TO THE ACCURACY OF THIS

INFORMATION AND IT IS OFFERED FOR INFORMATION ONLY.

3 VERIFY EXISTING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING AND SYSTEM COMPONENTS PRIOR TO THE DEMOLITION. IF EXISTING CONDITIONS ARE DIFFERENT THAN WHAT IS INDICATED ON THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL

NOTIFY THE COR AND ARCHITECT PRIOR TO PROCEEDING WITH THE WORK.

4 MINIMIZE DISTURBANCE AND / OR DAMAGE TO EXISTING FINISHED SURFACES AND FINISHES. WHERE DEMOLITION OF MECHANICAL SYSTEM COMPONENTS DAMAGES EXISTING SURFACES TO REMAIN, RESTORE THOSE SURFACES TO THE SAME CONDITION AS THE ADJACENT SURFACES. RESTORATION MUST BE PERFORMED BY WORKMEN SKILLED IN PERFORMING SUCH WORK. ALL FIRE AND SMOKE RATINGS SHALL BE RETAINED AS PART OF THE REPAIRS. PATCH / SEAL HOLES WATERTIGHT. ALL PATCHES AND REPAIRS

ARE SUBJECT TO THE REVIEW AND APPROVAL OF THE ARCHITECT.

5 ALL AREAS OF EGRESS SHALL BE KEPT OPEN AND FREE FROM DEBRIS AT ALL TIMES.

6 DO NOT REMOVE ITEMS SUPPORTING OTHER ITEMS WITHOUT PROVIDING TEMPORARY OR PERMANENT SUPPORT. PROPERLY SUPPORT ALL EXISTING ITEMS TO REMAIN.