This award notice documents a contract for a molecular analyzer. The Department of Veterans Affairs awarded a $255,000 contract to Hologic Sales and Service, LLC on September 21, 2023 to purchase a molecular real-time PCR analyzer and reagents. The analyzer must be able to run FDA-approved tests for SARS-CoV-2, influenza A and B, respiratory syncytial virus, and tests for mycoplasma genitalium, trichomonas vaginalis, chlamydia trachomatis, and neisseria gonorrhoeae. It must also have the capability to run laboratory-developed tests and have a throughput of at least 200 samples in 8 hours. The contract requires a one-year warranty on all parts and labor and application specialist training at installation and initial verification. Delivery is to occur within 90 days to the Syracuse VA Medical Center laboratory.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUBJECT*

MOLECULAR Analyzer for SARS-COV-2

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
12208-3410
SOLICITATION NUMBER*
36C24223Q1208

BASE NOTICE TYPE

ARCHIVE
30 DAYS AFTER THE AWARD DATE
RECOVERY ACT FUNDS
N
PRODUCT SERVICE CODE*
6640
NAICS CODE*
334516

SET-ASIDE

CONTRACTING OFFICE ADDRESS

Department of Veterans Affairs Samuel S . Stratton VA Medical Center 113 Holland Avenue (2-90NCA) Albany NY 12208-3410

POINT OF CONTACT*

Contracting Officer Anthony Murray Anthony.Murray2@va.gov 518-269-6103

AWARD INFORMATION

AWARD NUMBER*
36C24223P1863
AWARD AMOUNT*
$255,000.00
LINE ITEM NUMBER
5
AWARD DATE (MM-DD-YYYY)*
09-21-2023
AWARDEE NAME*
HOLOGIC SALES AND SERVICE, LLC
CONTRACTOR’S UEI
Q1NBY5GKN9Z3

AWARDEE ADDRESS LINE 1*

AWARDEE ADDRESS LINE 2*

AWARDEE ADDRESS LINE 3*
250 CAMPUS DRIVE

AWARDEE ADDRESS LINE 4*

AWARDEE CITY
MARLBOROUGH
AWARDEE STATE
MA
AWARDEE ZIP CODE
01752

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov
URL DESCRIPTION
Dept. of Veterans Affairs
AGENCY CONTACT’S EMAIL ADDRESS
Anthony.Murray2@va.gov
EMAIL DESCRIPTION
Contracting Officer

Award Notice Award Notice

DESCRIPTION

*= Required Field Award Notice Award Notice Statement of Work Molecular Analyzer for SARS-CoV-2 (COVID) and Respiratory Testing

A. GENERAL INFORMATION

Title of Project: Purchase of Molecular Analyzer and Reagents for SARS-CoV-2 (COVID) and Respiratory Testing

1. Type of Contract Contemplated: One time purchase for multiple assay molecular analyzer

B. SCOPE

The Syracuse Molecular laboratory requires capacity to expand SARS-COV-2/Influenza/RSV molecular testing to Veteran’s in the community in order to provide appropriate care in an inpatient and outpatient setting. Our current analyzer respiratory testing output is not sufficient. Procuring additional equipment and tests for molecular respiratory testing will allow the Syracuse VA Medical Center to manage patient symptoms sooner, decrease inpatient admissions and length of stay, and limit out of pocket expenses to Veteran’s whom require respiratory testing but are not admitted to the facility. Larger testing capacities will increase patient satisfaction and prevent some patient visits to the Emergency Room for those needing testing. The analyzer should enhance the laboratory’s ability expand PCR testing for other infectious diseases, such as STI’s and HPV.

C. REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS

Common Nomenclature (commercial description): : Molecular Real-Time PCR Analyzer

Principles of operation: The analyzer of choice will allow the laboratory to run real-time PCR, TMA, and RT-TMA assays on a single, automated platform. Test assays allow for nucleic acid amplification for qualitative detection of RNA for specific targets. Assays may combine the technologies of target capture, Transcription Mediated Amplification (TMA), and Dual Kinetic Assay (DKA). The analyzer must have the ability to run FDA approved testing for Respiratory and EUA for COVID. The analyzer must also have the ability to run FDA approved testing for STIs, Viral Loads, and BV, as well as have the functionality to run Laboratory Developed Tests (LDTs) all in one single integrated platform.

Intended use: To identify infectious diseases in clinical specimens by molecular methods.

Equipment with which the item is used :

Validation materials, including control materials, must be included with contract purchase. A back-up UPS battery must be included with purchase.

Original equipment manufacturer part number:

Other pertinent information that describes the item, material or service required:

1) The analyzer must have the capability to test for the following using PCR methods:

· SARS-CoV-2 virus

· Influenza A virus

· Influenza B virus

· Respiratory Syncytial Virus (RSV)

· Mycoplasma genitalium

· Trichomonas vaginalis

· Chlamydia trachomatis

· Neisseria gonorrhoeae

2) Pierceable foil caps, no uncapping prior to sample processing.

3) The analyzer must be high throughput with at least 200 samples able to be processed within 8 hours.

4) Laboratory preparedness system to rapidly respond to emerging pathogen(s) in an emergency

5) The analyzer must be fully automated to allow samples to run with minimal to no technologist intervention.

A continuous fluids/waste module to the lower bay of the system, allowing access to replace a set of universal fluids when depleted and dispose solid and liquid waste containers during processing, increasing flexibility and throughput to the system.

6) Continuous and random-access sample loading that allows both samples and reagents to be loaded at any time during the day

7) The testing should NOT include extractions or pre-treatment prior to analyzing specimen.

8) The analyzer should NOT require plumbing, as the laboratory does not have the ability to provide plumbing at this time.

9) All tests listed above must be FDA Approved or approved for Emergency Use Authorization (EUA).

D. OTHER UNIQUE REQUIREMENTS

Compatibility with Existing Equipment:

Applicable DICOM compliance, Directives or IT Policies:

Ensure that contractors, third party partners, and servicers implement the VA security and privacy requirements, as defined in the contract. These requirements can also be added to the contract Statement of Work (SOW). The requirements apply to applicable contracts in which VA sensitive information is stored, generated, transmitted, or exchanged by VA, a contractor, subcontractor or a third-party, or on behalf of any of these entities regardless of format or whether it resides on a VA system or contractor or subcontractor’s electronic information system(s) operating for or on the VA’s behalf.

Warranty: One year warranty all parts and labor included. Products shall be free from defects in workmanship and materials for a period of one (1) year from the date of purchase.

Training: An application Specialist must be on-site for installation of assay-specific applications and initial verification of assay-specific runs. In addition to verification support, it is required that the application specialist provide primary operator training. It is also requested that additional operator training is available for changes in personnel.

E. DELIVERY

Deliver to Syracuse VA loading dock/warehouse Inspection by BioMed/HTM

· Inspection and acceptance will occur in C322

· Delivery within 90 days of award.

F. PLACE OF PERFORMANCE

Syracuse VA Laboratory – 3rd Floor

G. BILLING/INVOICING – Tungsten Network Portal

H. CUSTOMER INFORMATION - Clinical Laboratory, Syracuse VA Medical Center