2023-02-27_BidPackage_FCEDC_16Academy_REVISED.pdf
PDF 10 MB Posted
- Attached to
- 16 Academy Street, Saranac Lake, NY State and local contract opportunity
- Solicitation number
- 2095232
- Issued by
- Genesee County, New York
About this file
This document is a bid package for a building renovation project at 16 Academy Street in Saranac Lake, New York, issued by the Franklin County Economic Development Corporation. The project requires the contractor to provide all labor and materials necessary to complete the renovations as described in the Project Workscope. The bid is due on March 16, 2023, at 5:00 PM, and the contract term is 9 months. There is no Service-Disabled Veteran-Owned Set Aside, but there are Minority Owned and Women Owned Sub-Contracting Goals of 10% each.
The bid package does not indicate any identical or substantially similar procurement contracts awarded within the past five years. The project is located in Franklin County, New York. No other pricing terms, incumbents, funding requirements, or other salient information is provided in the document.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Addendum.pdf | ||
| Bid Package 16 Academy Street Saranac Lake.pdf | ||
| 2023-03-08_Addendum_FCEDC_16Academy.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Saranac Lake Energize Downtown Fund
Bid Package for
16 Academy Street, Saranac Lake, NY
Administered by the
Franklin County Economic Development Corporation
355 West Main Street, Suite 428
Malone, New York 12953
Table of Contents
1. Section 01 - Advertisement For Bids
2. Section 02 - Information For Bidders
3. Section 03 – Project Workscope
4. Section 04 – Bid Form
Section 01
Advertisement For Bids
The Franklin County Economic Development Corporation (FCEDC) is currently accepting bids for exterior commercial renovations to be performed on a privately-owned building located at 16 Academy St. in the Village of Saranac Lake. The bid package may be obtained online at www.adirondackfrontier.com or by contacting or by contacting the FCEDC at help@adirondackfrontier.com.
Bids will be accepted until Thursday, March 16, 2023 at 5 PM. Bids shall be emailed to help@adirondackfrontier.com or mailed or delivered to: Franklin County Economic Development Corporation at 355 West Main Street, Suite 428, Malone, NY 12953.
The project must be complete by November 30, 2023.
In awarding bids, FCEDC and the property owner reserve the right to reject any and all bids, waive formalities, informalities and technicalities therein, and to take whatever bids it determines to be in the best interest of the FCEDC and property owner considering lowest or best bid, quality of goods and work, time of delivery or completion, responsibility of bidders being considered, previous experience of bidders, or any other factors they deem appropriate. Bids must be valid for a minimum of 60 days from the date of submission.
This project is funded in part through the Downtown Revitalization Initiative. As such, Bidders will be required to comply with all applicable Village, State and Federal requirements and regulations pertaining to the Program. However, Bidders should be aware that this project is not subject to State Prevailing Wage or Federal Davis-Bacon Wage requirements.
End of Section http://www.adirondackfrontier.com/ mailto:help@adirondackfrontier.com mailto:help@adirondackfrontier.com
Section 02
Information for Bidders
1. Location of the Work
16 Academy Street, Saranac Lake, NY 12983
2. Description of the Work
The Contractor will provide all labor and material necessary to complete building renovations at the above-referenced location as more fully described in Section 03 – Project Workscope. A pre-bid site visit may be scheduled by contacting Rachel Child, Community Development Specialist at (518) 481-8211 or rachel@adirondackfrontier.com.
3. Receipt & Opening of Bids
Bids shall be submitted using the Bid Form in Section 03. Bids will be received by the FCEDC until the time and at the place stated in the attached Advertisement For Bids. Bids shall be submitted using the Bid Form in Section 03. Bids will be received by the FCEDC until the time and at the place stated in the attached Advertisement For Bids. Bids shall be emailed to help@adirondackfrontier.com or mailed or delivered to: Franklin County Economic Development Corporation at 355 West Main Street, Suite 428, Malone, NY 12953.
4. Informalities, Waivers and Withdrawals
FCEDC may consider informal any Bid not prepared and submitted in accordance with the provisions hereof and may waive any informalities in or reject any or all Bids. Conditioned Bids or Bids which do not contain a price for every numbered item contained in the Bid form will not be accepted.
5. Obligations of Bidders
At the time of the opening of Bids, each Bidder will be presumed to have inspected the Site, to have informed himself fully of the conditions relating to the work and labor required for the work, and to have read and acquainted himself with all Contract Documents. Failure to do so will not relieve the Bidder who is awarded the Contract of his obligation to complete the work for the price or prices bid, or any other obligation under the Contract. The failure or omission of any Bidder to receive or examine any Contract Documents shall in no way relieve him from any obligation in respect to his Bid. The project is subject to all New York State rules and regulations and the Bidder will be presumed to have understood and accepted these requirements.
6. Bidders Representations
By making a Bid, the Bidder represents and warrants to FCEDC that (i) Bidder is and will be financially responsible and has and will have sufficient liquidity to meet its financial responsibilities under the Contract and for all other projects in which Bidder is or may mailto:rachel@adirondackfrontier.com become involved; (ii) Bidder is able to furnish the tools, materials, supplies, equipment, and labor required to complete the Work and perform the obligations required under the Contract Documents and has sufficient experience to do so; (iii) Bidder has carefully examined the Contract Documents and has visited and examined the project site; (iv) Bidder has satisfied itself as to the nature and location of the proposed Work, the general and local conditions, and all matters which may in any way affect the Work; (v) Bidder fully understands the intent and purpose of the Contract Documents, and (vi) the bid is based on labor, material, equipment, and systems required by the Contract Documents without exception. Claims for additional compensation and/or extension of time relating to Bidder’s noncompliance with such representations and warranties will not be allowed.
7. Contractual Arrangements
A contract will be issued between the property owner and the contractor exclusively. The FCEDC holds the right to monitor the project to ensure funding source compliance and the completeness of work. The property owner will be responsible for contractor payment and must abide by all grant program regulations.
8. Indemnity
The contractor shall indemnify and hold harmless the FCEDC and its employees, consultants and contractors from and against any and all claims, suits, actions, proceedings and any and all resulting damages, losses, costs and expenses of every nature, type and kind including reasonable attorney’s fees which claims arise out of work performed by the contractor, its subcontractors and others who are employed by the contractor or its subcontractors during the course of the project.
9. Award of Contract
The Contract will be awarded to the lowest responsible bidder as determined by FCEDC unless the owner of the subject property chooses a different bid and agrees to pay the difference between the preferred bid and the lowest responsible bid.
End of Section
Section 03
Project Workscope
Background:
16 Academy Street (the property), is a commercial use 1 story building located at 16 Academy Street, Saranac Lake, NY 12983. The Property was built circa 1950. The property is currently owned by Black Mountain Property Management, LLC. The owners have been awarded grant funding to demolish the existing single story structure and build a new 2-story commercial building.
The owner has provided an architectural sketch for the proposed demolition and new construction.
Permitting / Approvals / Lead Based Paint (LBP)
1. Project will require a building permit issued from the Village of Saranac Lake and inspections as specified by the code officer.
Scope of Work:
Demolition of the existing single-story commercial building. Construction of a new two-story commercial building.
See attached plans and specifications.
Attachments
A. Architectural plans and specifications
B. Demolition survey
Section 04
Bid Form – Page 1 of 4
Instructions: All bids shall be submitted using this form and must include all other documentation described in the Project Specifications.
Project Name: 16 Academy Street, Saranac Lake – Demolition & New Construction
Contractor Name:
Proposal Detail
Item Description Bid Price
1. PROJECT PLANNING, DETAILS, AND PERMITTING COSTS
2. REMOVALS
3. ASPHAULT AREAS
4. CONCRETE SIDEWALKS/PADS
5. ELECTRICAL, WATER, AND SEWER TO BUILDING
6. BUILDING EXCAVATION AND BACKFILL
7. TOP SOIL, SEE, MULCH, FENCHING & LANDSCAPING
8. CONCRETE FOOTERS AND WALLS COMPLETE
9. STEGO VAPOR BARRIER
10. EXTERIOR WALL FRAMED AND READY FOR SIDING
11. TRUSSES AND SHEATHING
12. WINDOWS AND EXTERIOR DOORS
13. SIDING, SOFFIT, GUTTERS, AND ACHITECTURAL WORK
14. ROOFING COMPLETE
15. INTERIOR FRAMING
16. INSULATION
17. SHEETROCK
18. TAPE AND PAINT
19. INTERIOR TRIM PACKAGE
20. FLOORING
21. TILE WORK
22. DROP CEILINGS
23. ELECTRICAL
24. PLUMBING
25. HVAC
26. SPRINKLER
27. FIRE ALARM
28. TOTAL
Instructions: The Bid Certification must be signed by a person authorized to enter into a contract on behalf of the company listed.
Bid Certification
I, the undersigned contractor, have inspected the above listed property and understand the extent and character of the work to be completed as described in the Project Specifications.
I propose to furnish all labor, materials, and equipment necessary to accomplish the work, as described in the Project Specifications, on the property located at _____________________________________________________, for the sum of ___________________________________________________________________dollars ($_____________).
I will commence the work within ________________________ calendar days from the date the notice to proceed is received and will complete the work within ________________________ calendar days after starting the work.
Company Name Signature
Title Date
Franklin County Main Street Program
Bid Form – Page 2 of 4
Instructions: Complete the following table. Attach additional sheets if necessary.
Company Information
Company Name: Officers, Partners, Owner Name(s):
Address: Address:
City: State: Zip: City: State: Zip:
Phone: Cell: Phone: Cell:
Email: Email:
Instructions: List the construction experience of each of the company principals: (Indicate number of years in the industry and if experience is new construction, rehabilitation, historic renovations, energy efficiency, etc.).
Attach additional sheets if necessary.
Experience
Principal Name: Principal Name:
Experience: Experience:
Instructions: List business references including local banks, subcontractors, and material suppliers.
Business References
Name: Name:
Address: Address:
City: State: Zip: City: State: Zip:
Phone: Phone:
Instructions: List customers with whom the company has recently done business.
Customer References
Name: Name:
Address: Address:
City: State: Zip: City: State: Zip:
Phone: Contract Amount: Phone: Contract Amount:
Bid Form – Page 3 of 4
Instructions: Attach documentation of insurance and EPA lead-based paint certification. If you do not have EPA lead-based paint certification state in the explanation section that it will be obtained prior to the start of construction.
Insurance & Lead-based Paint Certification
Documentation Submitted with application (Check all that apply) ✓
Liability Insurance
Workers’ Compensation Insurance
EPA Lead-based Paint certification
Explanation if not attached.
Instructions: Principal owners must sign and date the following Attestation.
Attestation The undersigned contractor certifies that all information given herein is correct and that the information may be verified from any source and further agrees:
1. That the contractor will perform the work in accordance with the description of work, general specifications, the NYS Uniform Fire Prevention and Building Code, the Village of Saranac Lake Code, and all other applicable rehabilitation guidelines and standards and be subject to a final inspection by the Village of Saranac Lake.
2. That if the work performed by the contractor is found to be unsatisfactory or if the contract relations between the contractor, property owner, or other parties are found to be unsatisfactory, the Franklin
County Economic Development Corporation may remove his/her name from the list of selected contractors without notice.
3. That contractor has proper insurance and EPA Lead-based Paint Certification.
4. That she/he will abide by all applicable equal employment opportunity regulations.
Contractor Name (Please Print)
Contractor Signature
Date
Bid Form – Page 4 of 4
NON-COLLUSIVE BIDDING CERTIFICATION
BY SUBMISSION OF THIS BID, BIDDERS AND EACH PERSON SIGNING ON BEHALF OF BIDDER CERTIFIES, AND IN
THE CASE OF JOINT BID, EACH PARTY THERETO CERTIFIES AS TO ITS OWN ORGANIZATION, UNDER PENALTY OF
PERJURY, THAT TO THE BEST OF HIS/HER KNOWLEDGE AND BELIEF:
1. The prices of this bid have been arrived at independently, without collusion, consultation, communication, or agreement, for the purpose of restricting competition, as to any matter relating to such prices with any other Bidder or with any competitor;
2. Unless otherwise required by law, the prices which have been quoted in this bid have not been knowingly disclosed by the Bidder and will not knowingly be disclosed by the Bidder prior to opening, directly or indirectly, to any other Bidder or to any competitor; and
3. No attempt has been made or will be made by the bidder to induce any other person, partnership or corporation to submit or not to submit a bid for the purpose of restricting competition.
A BID SHALL NOT BE CONSIDERED FOR AWARD NOR SHALL ANY AWARD BE MADE WHERE 1, 2, 3 ABOVE HAVE
NOT BEEN COMPLIED WITH; PROVIDED HOWEVER, THAT IF IN ANY CASE THE BIDDER(S) CANNOT MAKE THE
FORGOING CERTIFICATION, THE BIDDER SHALL SO STATE AND SHALL FURNISH BELOW A SIGNED STATEMENT
WHICH SETS FORTH IN DETAIL THE REASONS THEREFORE:
[BIDDERS AFFIX ADDENDUM TO THIS PAGE IF SPACE IS REQUIRED FOR STATEMENT]
Subscribed to under penalty of perjury under the laws of the State of New York, this___________ day of ________________, 20_ _ as the act and deed of said individual, corporation or partnership.
Person Legally Responsible for Binding Bidder
Name Title
Signature________________________________
Joint or combined bids must be certified on behalf of each participant
Legal name of person, firm or corporation Legal name of person, firm or corporation
Person(s) Legally Responsible for Binding Participant
Name Name
Title Title
Business Address Business Address
Bidder’s Identifying Data
Bidder’s Name
Business Address
Street
City State Zip
Telephone Fax_________________ E-mail
Federal id. Number_______________________________
If Bidder is a Partnership complete the following:
Name of Partners or Principals Business Address
If Bidder is a Corporation complete the following:
Name Business Address
President
Secretary
Treasurer
Drawn By:
BLACK MOUNTAIN
ARCHITECTURE, PLLC
CS
1 / 2 5 / 2 0 2 3
16 Academy St.
Saranac Lake, NY 12983
518.354.8340 (p)
NOTES
C O
N
ST
RU
C
TI
O
N D
O C
U M
EN
TS
S
ET
SI
G
N
ED
A N
D S
EA
LE
D P
LA
N
S
TO
B E
U
SE
D F
O R
PE
RM
IT
TI
N G
A N
D C
O N
ST
RU
C
TI
O N
P U
RP
O
SE
S
B
LA
C
K M
O U
N
TA
IN
A
RC
H
IT
EC
TU
RE
KS
Cover Sheets
Cover Sheet
A ca de m y
St re et S ar an ac L ak e
N ew
Y or k
Bl ac k M ou nt ai n
Pr op er ty
M an ag em en t, LL
C
ID
CS
AN100
LS100
SP000
SP100
SP101
SP102
D100
S000
S001
S100
S101
S200
S201
S300
S301
S400
S401
S402
S403
A001
A002
A100
A101
A200
A300
A400
A401
A402
A403
A500
A501
A502
A600
A700
E100
M1
M2
M3
P100
Sheet Name Cover Sheet
Architectural Notes
Life Safety Plan
Site Survey
Site Demo Plan
Site Plan
Grading Plan
Demolition Plans
General Notes
General Notes
Foundation Plan
Second Floor and Roof Framing
Building Sections
Moment Frame
Foundation Details
Foundation Details
Framing Details
Framing Details
Framing Details
Framing Details
Door & Window Schedule
Other Schedules
Floor Plans
Roof Plan
Exterior Elevations
Building Sections
Details
Details
Details
Details
Interior Elevations
Interior Elevations
Interior Elevations
RCPs
Floor Finish Plans
Concept Electrical Plans
1st & 2nd Floor Ductwork Plans
1st & 2nd Floor Piping Plans
Mech Equipment Schedules & Details
Concept Plumbing Plans
MAIN ST
LAKEFLOWER
ROUTE 3
BLOOMINGDALE
BROADWAY
LAKE
FLOWER
RTE 3
BLOOMINGDALE AVE
BROADWAY
MAIN ST
CHURCH ST
ACADEM
Y
SYRACUSE
ALBANY
SARANAC LAKE
NEWYORK
VERMONT
BURLINGTON
ADIRONDACKPARK
LAKE
ONTARIO
ADIRONDACK
PARK
SARANAC
LAKE
View from North (Academy Street)
View from South
Interior View from Entry
Interior View from Workstations
SITE
SITE
16 Academy Street Office Reconstruction: Construction Documents Set
PROJECT 3D IMAGES:
VICINITY MAPS:
SHEET INDEX:
ARCHITECT:
Black Mountain Architecture Jesse R. Schwartzberg 16 Academy Street Saranac Lake, N.Y. 12983 518.354.8340
SURVEYOR:
Marvin Land Surveying Bob Marvin Jr.
Lake Placid, 12946 518.523.3218
STRUCTURAL ENGINEER:
Artisan Engineering Ross Golde, John Higgins 120 Graham Way, Suite 124 Shelburne, VT 05482 802.497.3531
PROJECT TEAM:
ENERGY MODELING:
Cultivate Place Dylan Lamar Lea Celestial Portland, OR 541.207.2752
MECHANICAL ENGINEER:
Engineering Services of Vermont Jerry Marshall, Dana Curtis 5430 Waterbury Stowe Rd Waterbury Center, VT 05677 802.882.8449
ARCHITECTURE, PLLC
AN100
1 / 2 5 / 2 0 2 3
16 Academy St.
Saranac Lake, NY 12983
518.354.8340 (p)
NOTES
C O
N
ST
RU
C
TI
O
N D
O C
U M
EN
TS
S
ET
SI
G
N
ED
A N
D S
EA
LE
D P
LA
N
S
TO
B E
U
SE
D F
O R
PE
RM
IT
TI
N G
A N
D C
O N
ST
RU
C
TI
O N
P U
RP
O
SE
S
B
LA
C
K M
O U
N
TA
IN
A
RC
H
IT
EC
TU
RE
KS
Architectural Notes
Architectural Notes
A ca de m y
St re et S ar an ac L ak e
N ew
Y or k
Bl ac k M ou nt ai n
Pr op er ty
M an ag em en t, LL
C
A.F.F ABOVE FINISH FLOOR LAV. LAVATORY
AAC AUTOCLAVE-AERATED LKR. LOCKER
ACOUS. ACOUSTICAL LVL LAMINATED VANEER
LUMBER
AC ACOUSTICAL CEILING MH. MAN HOLE
ALUM. ALUMINUM MFGR. MANUFACTURER
&. AND MAS. MASONRY
APPROX. APPROXIMATE MECH. MECHANICAL
ARCH. ARCHITECTURAL MEMB. MEMBRANE
AUTO. AUTOMATIC MIR. MIRROR
BOT. BOTTOM MISC. MISCELLANEOUS
BLDG. BUILDING MTL. METEAL
CAB. CABINET MUL. MULLION
C.I.P. CAST IN PLACE NOM. NOMINAL
C.B. CATCH BASIN N. NORTH
CLG. CEILING N.I.C. NOT IN CONTRACT
CEM. CEMENT N.T.S. NOT TO SCALE
CTR. CENTER NO. OR # NUMBER
C.L. CENTER LINE OFF. OFFICE
COL. COLUMN O.C. ON CENTER
CONC. CONCRETE
CMU CONCRETE MASONRY UNIT
CONT. CONTINUOS OPG. OPENING
CONTR. CONTRACTOR O.A. OVERALL
C.J. CONTROL JOINT OVHD. OVERHEAD
CORR. CORRIDOR PR. PAIR
CNTR. COUNTER PNL. PANEL
DEPT. DEPARTMENT PAV. PAVING
DET. DETAIL PTN. PARTITION
DIA. DIAMETER PH. PHASE
DIM. DIMENSION LPAS. PLASTER
DR. DOOR PLBG. PLUMBING
D.O. DOOR OPENING PLYWD. PLYWOOD
DBL. DOUBLE PTN. PRESSURE-TREATED
DN. DOWN POL. POLISHED
DS. DOWN SPOUT P.C. PRECAST CONCRETE
EA. EACH PSL PARALLEL STRAND
LUMBER
E. EAST, ELECTRICAL R.W.L. RAIN WATER LEADER
ELEC. ELECTRICAL RWD. REDWOOD
EL. ELEVATION REF. REFERENCE
EMER. EMERGENCY REFL. REFLECTIVE
ENCL. ENCLOSURE REFR. REFRIGERATOR
EQ. EQUAL REINF. REINFORCED
EQUIP. EQUIPMENT REQ'D REQUIRED
(E) EXISTING RESIL. RESILIENT
EXST. EXISTING REV. REVISION OR REVISED
E.J. EXPANSION JOINT R.O. ROUGH OPENING
EXT. EXTERIOR SAN. SANITARY
E.I.F.S EXTERIOR INSULATION
FINISH SYSTEM SCHED SCHEDULE
F.O. FACE OF SECT SECTION
F.C. FACE OF CONCRETE SSD SEE STRUCTURAL
DRAWINGS
F.F. FACE OF FINISH SED SEE ELECTRICAL
DRAWINGS
F.S. FACE OF STUDS SMD SEE MECHANICAL
DRAWINGS
FIN. FINISH SLD SEE LANDSCAPING
DRAWINGS
F.F.E. FINISH FLOOR ELEVATION SPD SEE PLUMBING
DRAWINGS
F.A. FIRE ALARM SCD SEE CIVIL DRAWINGS
F.E. FIRE EXRINGUISHER SHT. SHEET
F.E.C. FIRE EXRINGUISHER
CABINET SHR. SHOWER
F.H.C. FIRE HOSE CABINET S.C. SOLID CORE
FPRF. FIREPROOF S.C. SOUTH
FPNG. FIREPROOFING SPKR. SPEAKER
FLASH. FLASHING SPEC. SPECIFICATION
FL. FLOOR SPKLR. SPRINKLER
F.D FLOOR DRAIN S.H. SPRINKLER HEAD
FLUOR. FLUORESCENT SQ. SQUARE
FT. FOOT OR FEET SSTL STAINLESS STEEL
FTG. FOOTING STD. STANDARD
FDN. FOUNDATION STA. STATION
FR. FRAME STL. STEEL
FURR. FURRING STOR. STORAGE
FUT. FUT. STR. STRUCTURAL
GALV. GALVANIZED SUSP. SUSPENDED
GA. GAUGE SYM. SYMMETRICAL
G.C. GENERAL CONTRACTOR TEL. TELEPHONE
GL. GLASS T.V. TELEVISION
GR. GRADE TEMP. TEMPERED
GL. GRID LINE T. & G. TONGUE AND GROVE
GYP. GYPSUM T.O. TOP OF
GWB. GYPSUM WALL BOARD T.O.S. TOP OF SLAB
HCP. HANDICAPPED T.O.W. TOP OF WALL
HDWD HARDWOOD TYP TYPICAL
HVAC HEATING, VENTILATION,
AIR CONDITIONING UNF. UNFINISHED
HT. HEIGHT U.O.N. UNLESS OTHERWISE
NOTED
H.C. HOLLOW CORE UR. URINAL
H.M. FOLLOW METAL VB. VAPOR BARRIER
H.B. HOSE BIB V.I.F. VERIFY IN FIELD
HR. HOUR VERT. VERTICAL
INCAN. INCANDESCENT VEST. VESTIBULE
INCL. INCLUDE(D)(ING) WSCT. WAINSCOT
INS. INSULATION W.C. WATER CLOSET
INT. INTERIOR WP. WATERPROOFING
INTUM. INTUMESCENT W. WEST
INV. INVERT W. WIDTH
JAN. JANITOR WDW. WINDOW
JT. JOINT W/ WITH
JST. JOIST W/O WITHOUT
KIT. KITCHEN WD. WOOD
OWNER-PROVIDED,
CONTRACTOR
INSTALLED
O.P.C.I.
1. ALL CONSTRUCTION & DEMOLITION SHALL COMPLY WITH ALL APPLICABLE NATIONAL,
STATE, & LOCAL CODES, INCLUDING ALL OSHA REGULATIONS.
2. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT ALL PEOPLE
WHO MAY BE ON OR NEAR THE WORK AREA BY MAINTAINING A SAFE WORK AREA, SAFE
WORKING CONDITIONS, & LIMITING ACCESS TO THE WORK AREA.
3. CONTRACTOR IS FULLY RESPONSIBLE FOR THE WORKERS' SAFETY, SAFETY EQUIPMENT,
FIRST-AID, & EMERGENCY HANDLING PROCEDURES.
4. CONTRACTOR SHALL PERSONALLY SUPERVISE THE WORK & SHALL BE PRESENT AT THE
WORK SITE AT ALL TIMES DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE
ADEQUATE PERSONNEL FOR THE PROPER COORDINATION & EXECUTION OF THE WORK.
5. ALL DIMENSIONS & ELEVATIONS ARE TO BE USED FOR GENERAL INFORMATION ONLY.
CONTRACTOR TO VERIFY CONDITIONS AT SPECIFIC LOCATIONS AS REQ'D TO CONFIRM &
PERFORM ALL WORK SPECIFIED.
6. ALL WINDOW & DOOR OPENING DIMENSIONS REFER TO ROUGH OPENING (R.O.).
7. THESE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. WRITTEN
DIMENSIONS GOVERN. THE WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE.
8. CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS PRIOR TO THE COMMENCEMENT OF
WORK & PRIOR TO ORDERING ANY PRODUCT OR PROPRIETARY SYSTEM. CONTRACTOR
SHALL NOTIFY THE OWNER OF ANY EXISTING CONDITIONS REQUIRING MODIFICATION
PRIOR TO THE BEGINNING OF ANY WORK.
9. IN CASE OF OMISSIONS OR DISCREPANCIES IN THESE DOCUMENTS, CONSULT WITH THE
ARCHITECT PRIOR TO ORDERING ANY PRODUCT, MATERIAL, OR PROPRIETARY SYSTEM, OR
PRIOR TO PROCEEDING WITH SHOP DRAWINGS OR ANY OTHER WORK. WHERE SPECIFIC
DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT WITH
ARCHITECT BEFORE PROCEEDING WITH WORK.
10. SUBCONTRACTORS FOR EACH TRADE ARE ADVISED THAT INFORMATION PERTINENT TO
THEIR WORK MAY OCCUR IN OTHER PORTIONS OF THE CONTRACT DOCUMENTS. REFER TO
CIVIL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING & THIER OWN DISCIPLINE'S
DRAWINGS FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS & SYMBOLS.
11. THE STRUCTURAL DRAWINGS ARE OF EQUAL IMPORTANCE AS THE ARCHITECTURAL
DRAWINGS IN DEFINING THE WORK OF THE CONTRACT DOCUMENTS. IT SHALL BE THE
RESPONISBILITY OF THE CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS
BEFORE THE INSTALLATION OF STRUCTURAL, MECHANICAL OR ELECTRICAL WORK. SHOULD
THERE BE A DISCREPANCY BETWEEN ARCHITECTURAL & ENGINEERING DRAWINGS THAT
WOULD CAUSE AN AWKWARD OR IMPROPER INSTALLATION, IT SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT FOR CLARIFICATION PRIOR TO INSTALLATION OF SAID
WORK.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SURVEYING & VERIFYING EXISTING
CONDITIONS, INCLUDING BUT NOT LIMITED TO THE LOCATION, ELEVATIONS, DIMENSIONS,
AND ACCURATE PLACEMENT OF THE BUILDING ON THE SITE.
13. DISCOVERY OF ANY HAZARDOUS MATERIALS ON SITE SHALL BE CONTAINED OR
REMOVED AS REQUIRED BY PROPER AUTHORITIES.
14. CONTRACTOR TO PROVIDE TEMPORARY GUARD RAILS, STAIRS & PROTECTION AS REQ'D
TO MAINTAIN SAFE WORKING CONDITIONS.
15. FOR ADDITIONAL NOTES, SEE PLANS AND BUILDING ELEVATION DRAWINGS & PROJECT
SPECIFICATIONS.
16. ALL DRAWINGS TO BE REVIEWED BY LOCAL BUILDING DEPARTMENT FOR APPROVAL
PRIOR TO COMMENCING WORK.
17. THE CONTRACTOR SHALL COORDINATE ALL SLAB PENETRATION, RATED CEILING
OPENING FRAMING & FOUNDATION WALL SLEEVE LOCATIONS. NO CORE DRILLING SHALL
BE ALLOWED ON FOUNDATION WALLS.
18. ANY DETAILS, SYSTEMS, MATERIALS (ARCH., MEP, STRUCT., ETC.) PROPOSED TO BE
CHANGED MUST FIRST BE REVIEWED BY THE ARCHITECT, OWNER AND OWNERS’
REPRESENTATIVE PRIOR TO THE PREPARATION OF THE SHOP DRAWINGS AND/OR
COMMENCEMENT OF THE WORK.
19. COORDINATE PLACING OF ALL CEILING ELEMENTS W/ MEP, SECURITY AND A/V
DRAWINGS. PROVIDE COORDINATION DRAWINGS INCLUDING ALL TRADES WHERE
DISCREPANCIES MAY OCCUR. CONSULT WITH ARCHITECT PRIOR TO PROCEEDING WITH
WORK.
20. PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES & AS REQUIRED FOR
MECHANICAL EQUIPMENT. ALL ACCESS PANELS SHALL BE CONCEALED & ALL LOCATIONS
SHALL BE REVIEWED BY THE ARCHITECT PRIOR TO PROCEEDING W/ WORK.
21. COORDINATE & PROVIDE BLOCKING AS REQ'D WITHIN PARTITIONS FOR ALL MILLWORK
AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS.
22. PATCH & REPAIR ALL EXISTING WALLS, COLUMNS AND SURFACES SCHEDULED TO
REMAIN AS REQUIRED TO GET THEM SMOOTH & EVEN TO RECIEVE NEW SCHEDULE
FINISHES.
23. ALL DUCT OPENINGS & RELATED AIR DISTRIBUTUION COMPONENT OPENINGS SHALL BE
COVERED DURING CONSTRUCTION.
24. MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALL AND FLOOR FRAMING
SHALL BE CHECKED PRIOR TO ENCLOSURE.
25. THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS & METHODS OF CONSTRUCTION
INCLUDING THE DESIGN OF SHORING, SCAFFOLDING & FRAMEWORK.
1. ALL WORK IS TO COMPLY WITH THE LATEST ADOPTED VERSION
OF THE NEW YORK STATE BUILDING CODE & ANY APPLICABLE
STATE, COUNTY, OR LOCAL REGULATIONS.
2. ALL REQUIRED & NECESSARY PERMITS SHALL BE SECURED FROM
ALL AGENCIES HAVING JURISDICTION BY THE CONTRACTOR
PRIOR TO THE START OF WORK.
3. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING FOR ANY
ERRORS OR OMISSIONS & NOTIFYING THE ARCHITECT, PRIOR
TO THE START OF CONSTRUCTION.
4. CONTRACTOR TO REVIEW DOCUMENTS, VERIFY DIMENSIONS &
FIELD CONDITIONS & CONFIRM THAT WORK IS BUILDABLE AS
SHOWN PRIOR TO PURCHASE, FABRICATION, INSTALLATION,
OR COMENCEMENT OF WORK. THE CONTRACTOR SHALL
REPORT ANY CONFLICTS AND/OR OMISSIONS TO THE
ARCHITECT PRIOR TO PERFORMING ANY WORK IN QUESTION.
5. SUBMIT REQUESTS FOR SUBSTITUTION, REVISIONS, AND/OR
CHANGES TO THE ARCHITECT, IN WRITING, FOR REVIEW PRIOR
TO PURCHASE, FABRICATION, INSTALLATION, OR
COMENCEMENT OF WORK.
6. THESE DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION
PURPOSES. WRITTEN DIMENSIONS GOVERN. IN CASE OF
CONFLICT, THE CONTRACTOR SHALL SUMBIT A WRITTEN
REQUEST FOR CLARIFICATION OR INFORMATION TO THE
ARCHITECT.
7. THE CONTRACTOR SHALL REPORT TO THE ARCHITECT &
ENGINEER(S) ANY CONDITION(S) THAT PREVENT(S) OR
OTHERWISE ALTER(S) THE EXECUTION OF WORK AS INDICATED
ON THE CONSTRUCTION DOCUMENTS. ALL NOTES,
DIMENSIONS, DETAILS, & JOB CONDITIONS ARE TO BE
CHECKED & VERIFIED. ANY DISCREPANCY SHALL BE BROUGHT
TO THE ATTENTION OF THE ARCHITECT & ENGINEER(S) PRIOR
TO THE COMMENCEMENT OF WORK.
8. EACH CONTRACTOR WILL BE HELD RESPONSIBLE FOR HIS/HER
WORK. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR THE COORDINATION OF WORK OF ALL TRADES.
9. THE CONTRACTOR IS REQUIRED TO BE PRESENT AT FINAL
INSPECTION WITH BUIDLING OFFICIALS.
10. THE CONTRACTOR SHALL, UPON COMPLETION OF THE WORK,
SEE THAT THE JOB IS BROOM-SWEPT.
11. SEE STRUCTURAL & CIVIL ENGINEERING DOCUMENTS FOR
ADDITIONAL INFORMATION AND REQUIREMENTS.
GENERAL ARCHITECTURAL NOTES: ABBREVIATIONS:
THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES AS
REQUIRED BY THE TOWN OF HARRIETSTOWN, NEW YORK:
2020 NEW YORK STATE RESIDENTIAL CODE
2020 NEW YORK STATE EXISTING BUILDING CODE
2020 FIRE CODE OF NEW YORK STATE
2020 PLUMBING CODE OF NEW YORK STATE
2020 MECHANICAL CODE OF NEW YORK STATE
2020 FUEL GAS CODE OF NEW YORK STATE
2020 ENERGY CONSERVATION CODE OF NEW YORK STATE
2020 PROPERTY MAINTENANCE CODE OF NEW YORK STATE
APPLICABLE CODES:
DESCRIPTION-
THIS PROJECT IS A TWO-STORY COMMERCIAL RECONSTRUCTION PROJECT OF TYPE
V-B CONSTRUCTION. THE EXISTING BUILDING IS TO BE DEMOLISHED AND
RECONSTRUCTED AS AN ENERGY-EFFICIENT, TWO-STORY OFFICE. IN ADDITION TO
DEMO AND NEW CONSTRUCTION SCOPE, THE PROJECT INCLUDES SITE WORK.
GRANULAR DRAINAGE FILL WILL BE INSTALLED AT THE SOUTH OF THE SITE, AND
NEW SIDEWALK AND PLANTERS ARE TO BE PROVIDED AT THE NORTH ENTRY ON
ACADEMY STREET.
PROJECT SCOPE:
MATERIAL LEGEND:
EARTH
GRAVEL
/STONE
CONCRETE
ALUMINUM
WOOD
BLOCKING
FINISHED
WOOD
PLYWOOD
RIGID
INSULATION
BATT
INSULATION
GYPSUM
WALLBOARD
C.C.S.F.
REFERENCE/SYMBOLS LEGEND:
A-11
DETAIL REFERENCE
DETAIL NUMBER
SHEET NUMBER
SECTION REFERENCE
SECTION NUMBER
SHEET NUMBER
INTERIOR ELEVATION
ELEVATION NUMBER
SHEET NUMBER
DOOR (SEE DOOR SCHEDULE FOR DETAILS)
DOOR NUMBER IN SCHEDULE
D12
W12 WINDOW/LOUVER (SEE WINDOW SCHEDULE FOR DETAILS)
WINDOW NUMBER IN SCHEDULE
DATUM REFERENCE
WORK POINT, CONTROL POINT OR DATUM POINT
GRID LINES
A
ELEVATION REFERENCE
ELEVATION NUMBER
SHEET NUMBER
CONSTRUCTION NOTES:
PROJECT AREA SUMMARY:
CLIENT/PROPERTY OWNER:
JESSE SCHWARTZBERG
ZONING DISTRICT:
VILLAGE OF SARANAC LAKE, DISTRICT E3
BUILDING USE & OCCUPANCY GROUP:
BUSINESS GROUP B
TYPE OF CONSTRUCTION:
TYPE V-B
ALLOWABLE HEIGHTS:
R305.1 MINIMUM HEIGHT:
HABITABLE SPACE, HALLWAYS AND PORTIONS OF BASEMENTS CONTAINING THESE SPACES
SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET (2134 MM). BATHROOMS, TOILET
ROOMS AND LAUNDRY ROOMS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 6 FEET 8
INCHES (2032 MM).
EXCEPTIONS:
-FOR ROOMS WITH SLOPED CEILINGS, THE REQUIRED FLOOR AREA OF THE ROOM SHALL
HAVE A CEILING HEIGHT OF NOT LESS THAN 5 FEET (1524 MM) AND NOT LESS THAN 50
PERCENT OF THE REQUIRED FLOOR AREA SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN
7 FEET (2134 MM).
-THE CEILING HEIGHT ABOVE BATHROOM AND TOILET ROOM FIXTURES SHALL BE SUCH THAT
THE FIXTURE IS CAPABLE OF BEING USED FOR ITS INTENDED PURPOSE. A SHOWER OR TUB
EQUIPPED WITH A SHOWERHEAD SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 6 FEET 8
INCHES (2032 MM) ABOVE AN AREA OF NOT LESS THAN 30 INCHES (762 MM) BY 30 INCHES
(762 MM) AT THE SHOWERHEAD.
-BEAMS, GIRDERS, DUCTS OR OTHER OBSTRUCTIONS IN BASEMENTS CONTAINING HABITABLE
SPACE SHALL BE PERMITTED TO PROJECT TO WITHIN 6 FEET 4 INCHES (1931 MM) OF THE
FINISHED FLOOR.
LOT SIZE: 0.05ACRES
BUILDING HEIGHT: 29'-2"
FIRST FLOOR AREA: 1,145 ft2
SECOND FLOOR AREA: 1,145 ft2
PARKING SPACES: 0
PROJECT DATA:
A-11
A-11
A-11
ARCHITECTURE, PLLC
LS100
1 / 2 5 / 2 0 2 3
16 Academy St.
Saranac Lake, NY 12983
518.354.8340 (p)
NOTES
C O
N
ST
RU
C
TI
O
N D
O C
U M
EN
TS
S
ET
SI
G
N
ED
A N
D S
EA
LE
D P
LA
N
S
TO
B E
U
SE
D F
O R
PE
RM
IT
TI
N G
A N
D C
O N
ST
RU
C
TI
O N
P U
RP
O
SE
S
B
LA
C
K M
O U
N
TA
IN
A
RC
H
IT
EC
TU
RE
KS
Life Safety
Life Safety Plan
A ca de m y
St re et S ar an ac L ak e
N ew
Y or k
Bl ac k M ou nt ai n
Pr op er ty
M an ag em en t, LL
C
3' DOOR
CLEAR WIDTH: 33"
33'-10"
STAIR
CLEAR WIDTH: 3'-6"
24'-10
29'-3"
1-HR RATED
WALL ASSEMBLY
1-HR RATED
WALL ASSEMBLY
3' DOOR
CLEAR WIDTH: 33"
3' DOOR
CLEAR WIDTH: 33"
A A
B B
1-HR RATED
WALL ASSEMBLY
1-HR RATED
WALL ASSEMBLY
72'-9"
STAIR
CLEAR WIDTH: 3'-6"
A A
B B
1/4" = 1'-0"1 First Floor Life Safety Plan 1/4" = 1'-0"2 Second Floor Life Safety Plan
AREA
OCCUPANT LOAD FACTOR
(GROUP B - BUSINESS)
OCCUPANT LOAD
FIRST FLOOR
SECOND FLOOR
TOTAL
1,145 SF 150 SF / OCCUPANT 8 OCCUPANTS
1,145 SF 150 SF / OCCUPANT 8 OCCUPANTS
2,290 SF 150 SF / OCCUPANT 16 OCCUPANTS
BUILDING OCCUPANCY
NOTE: BUILDING TO BE SPRINKLERED THROUGHOUT.
CONTRACTOR TO PROVIDE SUBMITTAL & SHOP DRAWINGS
FOR PROPOSED SPRINKLER SYSTEM & CONFIGURATION.
ARCHITECTURE, PLLC
SP000
1 / 2 5 / 2 0 2 3
16 Academy St.
Saranac Lake, NY 12983
518.354.8340 (p)
NOTES
C O
N
ST
RU
C
TI
O
N D
O C
U M
EN
TS
S
ET
SI
G
N
ED
A N
D S
EA
LE
D P
LA
N
S
TO
B E
U
SE
D F
O R
PE
RM
IT
TI
N G
A N
D C
O N
ST
RU
C
TI
O N
P U
RP
O
SE
S
B
LA
C
K M
O U
N
TA
IN
A
RC
H
IT
EC
TU
RE
KS
Site
Site Survey
A ca de m y
St re et S ar an ac L ak e
N ew
Y or k
Bl ac k M ou nt ai n
Pr op er ty
M an ag em en t, LL
C
Academy Street
I
II
1 Site Survey
SURVEY PROVIDED BY MARVIN LAND SURVEYING
SITE NOTES:
1. CODE:
ALL APPLICABLE CODES ARE TO BE MET BY
THE CONTRACTOR AND ALL
SUBCONTRACTORS PERFORMING WORK ON
THIS PROJECT.
2. SETBACKS:
ALL BUILDINGS (INCLUDING ROOFS, EAVES,
PORCHES, DECKS, AND FOOTINGS) AND
RETAINING WALLS ARE TO BE WITHIN
PROPERTY SETBACKS, UNLESS A VARIANCE
HAS BEEN APPROVED.
3. NOTIFY THE ARCHITECT IMMEDIATELY IF ANY
CONFLICTS ARISE.
4. CONTRACTOR TO VERIFY IN-GROUND AND
OVERHEAD UTILITIES LOCATIONS BEFORE
CONSTRUCTION COMMENCES.
SITE DEMOLITION NOTES:
1. CONTRACTOR TO PROVIDE
TEMPORARY STRUCTURAL SUPPORT
DURING DEMOLITION. CONTACT
ARCHITECT & STRUCTURAL ENGINEER
IF QUESTIONS ARISE.
PROPOSED BUILDINGS
DEMO SITE CONTOURS
PROPOSED CONTOURS
PROPOSED BOULDERS
SITE LEGEND:
PROPERTY LINE
EXISTING DECIDUOUS TREE
EXISTING CONIFEROUS TREE
EXISTING PLANTS / VEGETATION
EXISTING BUILDINGS TO
REMAIN
DEMOLITION AREA
EXISTING SITE CONTOURS
TREE TO BE DEMOLISHED
OVERHEAD ELECTRIC
LINE
BURIED ELECTRIC
LINE
EXISTING DRIVEWAY
PROPOSED DRIVEWAY
N
Drawn By:
BLACK MOUNTAIN
ARCHITECTURE, PLLC
SP100
1 / 2 5 / 2 0 2 3
16 Academy St.
Saranac Lake, NY 12983
518.354.8340 (p)
NOTES
#CADTechnician
Site
Site Demo Plan
A ca de m y
St re et S ar an ac L ak e
N ew
Y or k
Bl ac k M ou nt ai n
Pr op er ty
M an ag em en t, LL
C
C O
N
ST
RU
C
TI
O
N D
O C
U M
EN
TS
S
ET
SI
G
N
ED
A N
D S
EA
LE
D P
LA
N
S
TO
B E
U
SE
D F
O R
PE
RM
IT
TI
N G
A N
D C
O N
ST
RU
C
TI
O N
P U
RP
O
SE
S
B
LA
C
K M
O U
N
TA
IN
A
RC
H
IT
EC
TU
RE
DRIVEWAY
PR
O
PE
RT
Y
LI
N E
PR
O
PE
RT
Y
LI
N E
PROPERTY LINE
PROPERTY LINE DEMO & RELOCATE
WATER METER
EXIST. ELEC.
POLE
ACADEMY STREET
EXISTING ABOVE-GROUND
FUEL TANK
(TO BE REMOVED)
EXISTING MAN HOLE COVER, USED AS 500'-0" BASIS
FOR SITE SURVEY ELEVATIONS. REFER TO SITE SURVEY
ON SHEET SP000. COORDINATE SITE ELEVATIONS W/
ARCHITECTURAL & STRUCTURAL LEVELS.
REPUTED OWNER:
CHARLES & ELIZABETH
NICASTRO
REPUTED OWNER:
KENNETH & PATRICIA WILEY
REPUTED OWNER:
JOHN & KAREN HUTTLINGER
DEMO BRICK PLANTERS
DEMO BRICK
WING WALL
DEMO SITE SURFACE AS REQ'D FOR
REMOVAL & RECONSTRUCTION OF
EXIST. BLDG.
DRIVEWAY
EXIST. SIDEWALK
TO REMAIN
PLANTER
EXISTING BUILDING TO BE DEMOLISHED.
REFER TO SHEET D100 FOR BUILDING DEMO PLANS.
CONC.
SLAB
EXISTING STREET
LIGHT TO REMAIN
REPUTED OWNER:
BLACK MOUNTAIN PROPERTY
MANAGEMENT, LLC
1" = 5'1 Architectural Site Demolition Plan
ALL APPLICABLE CODES ARE TO BE MET BY
THE CONTRACTOR AND ALL
SUBCONTRACTORS PERFORMING WORK ON
THIS PROJECT.
2. SETBACKS:
ALL BUILDINGS (INCLUDING ROOFS, EAVES,
PORCHES, DECKS, AND FOOTINGS) AND
RETAINING WALLS ARE TO BE WITHIN
PROPERTY SETBACKS, UNLESS A VARIANCE
HAS BEEN APPROVED.
3. NOTIFY THE ARCHITECT IMMEDIATELY IF ANY
CONFLICTS ARISE.
4. CONTRACTOR TO VERIFY IN-GROUND AND
OVERHEAD UTILITIES LOCATIONS BEFORE
CONSTRUCTION COMMENCES.
SITE DEMOLITION NOTES:
1. CONTRACTOR TO PROVIDE
TEMPORARY STRUCTURAL SUPPORT
DURING DEMOLITION. CONTACT
ARCHITECT & STRUCTURAL ENGINEER
IF QUESTIONS ARISE.
PROPOSED BUILDINGS
DEMO SITE CONTOURS
PROPOSED CONTOURS
PROPOSED BOULDERS
SITE LEGEND:
PROPERTY LINE
EXISTING DECIDUOUS TREE
EXISTING CONIFEROUS TREE
EXISTING PLANTS / VEGETATION
EXISTING BUILDINGS TO
REMAIN
DEMOLITION AREA
EXISTING SITE CONTOURS
TREE TO BE DEMOLISHED
OVERHEAD ELECTRIC
LINE
BURIED ELECTRIC
LINE
EXISTING DRIVEWAY
PROPOSED DRIVEWAY
N
Drawn By:
BLACK MOUNTAIN
ARCHITECTURE, PLLC
SP101
1 / 2 5 / 2 0 2 3
16 Academy St.
Saranac Lake, NY 12983
518.354.8340 (p)
NOTES
#CADTechnician
Site
Site Plan
A ca de m y
St re et S ar an ac L ak e
N ew
Y or k
Bl ac k M ou nt ai n
Pr op er ty
M an ag em en t, LL
C
C O
N
ST
RU
C
TI
O
N D
O C
U M
EN
TS
S
ET
SI
G
N
ED
A N
D S
EA
LE
D P
LA
N
S
TO
B E
U
SE
D F
O R
PE
RM
IT
TI
N G
A N
D C
O N
ST
RU
C
TI
O N
P U
RP
O
SE
S
B
LA
C
K M
O U
N
TA
IN
A
RC
H
IT
EC
TU
RE
A
PP
RO
X.
0"
APPROX. 17'-0"
MAIN
ENTRY
BOULDER
PLANTER
BOULDER
PLANTER
EXISTING SIDEWALK
NEW TREE
DRIVEWAY
2ND FL.
ENTRY
EXISTING STREET LIGHT
PR
O
PE
RT
Y
LI
N E
PR
O
PE
RT
Y
LI
N E
PROPERTY LINE
PROPERTY LINE
EXIST. ELEC.
POLE
ACADEMY STREET
GATE
CRUSHED
STONE
CLEAN GRANULAR FILL AT
SE CORNER OF SITE.
PROVIDE SUBMITTAL.
LAWN
BOULDER RETAINING AS
REQ'D AT SW CORNER
LAWN
1/2" PER
FT
CONCRETE SIDEWALK INFILL B/W
PROPERTY LINE & FOUNDATION;
EXCEPT FOR PLANTING AREAS.
DSDS
EXISTING MAN HOLE COVER, USED AS 500'-0" BASIS
FOR SITE SURVEY ELEVATIONS. REFER TO SITE SURVEY
ON SHEET SP000. COORDINATE SITE ELEVATIONS W/
ARCHITECTURAL & STRUCTURAL LEVELS.
REPUTED OWNER:
CHARLES & ELIZABETH
NICASTRO
REPUTED OWNER:
KENNETH & PATRICIA WILEY
REPUTED OWNER:
JOHN & KAREN HUTTLINGER
TRASH &
RECYC.
BUILDING FOOTPRINT
UG SERVICE FROM EXIST. POLE TO NEW PANEL
SO
IL
L
IN
E
TO
V
IL
LA
G
E
SE
W
ER
COORDINATE W/ ELECTRICAL PLANS
DS
REPUTED OWNER:
BLACK MOUNTAIN PROPERTY
MANAGEMENT, LLC
1" = 5'1 Architectural Site Plan
ALL APPLICABLE CODES ARE TO BE MET BY
THE CONTRACTOR AND ALL
SUBCONTRACTORS PERFORMING WORK ON
THIS PROJECT.
2. SETBACKS:
ALL BUILDINGS (INCLUDING ROOFS, EAVES,
PORCHES, DECKS, AND FOOTINGS) AND
RETAINING WALLS ARE TO BE WITHIN
PROPERTY SETBACKS, UNLESS A VARIANCE
HAS BEEN APPROVED.
3. NOTIFY THE ARCHITECT IMMEDIATELY IF ANY
CONFLICTS ARISE.
4. CONTRACTOR TO VERIFY IN-GROUND AND
OVERHEAD UTILITIES LOCATIONS BEFORE
CONSTRUCTION COMMENCES.
SITE DEMOLITION NOTES:
1. CONTRACTOR TO PROVIDE
TEMPORARY STRUCTURAL SUPPORT
DURING DEMOLITION. CONTACT
ARCHITECT & STRUCTURAL ENGINEER
IF QUESTIONS ARISE.
PROPOSED BUILDINGS
DEMO SITE CONTOURS
PROPOSED CONTOURS
PROPOSED BOULDERS
SITE LEGEND:
PROPERTY LINE
EXISTING DECIDUOUS TREE
EXISTING CONIFEROUS TREE
EXISTING PLANTS / VEGETATION
EXISTING BUILDINGS TO
REMAIN
DEMOLITION AREA
EXISTING SITE CONTOURS
TREE TO BE DEMOLISHED
OVERHEAD ELECTRIC
LINE
BURIED ELECTRIC
LINE
EXISTING DRIVEWAY
PROPOSED DRIVEWAY
N
Drawn By:
BLACK MOUNTAIN
ARCHITECTURE, PLLC
SP102
1 / 2 5 / 2 0 2 3
16 Academy St.
Saranac Lake, NY 12983
518.354.8340 (p)
NOTES
#CADTechnician
Site
Grading Plan
A ca de m y
St re et S ar an ac L ak e
N ew
Y or k
Bl ac k M ou nt ai n
Pr op er ty
M an ag em en t, LL
C
C O
N
ST
RU
C
TI
O
N D
O C
U M
EN
TS
S
ET
SI
G
N
ED
A N
D S
EA
LE
D P
LA
N
S
TO
B E
U
SE
D F
O R
PE
RM
IT
TI
N G
A N
D C
O N
ST
RU
C
TI
O N
P U
RP
O
SE
S
B
LA
C
K M
O U
N
TA
IN
A
RC
H
IT
EC
TU
RE
EXISTING MAN HOLE COVER, USED AS 500'-0" BASIS
FOR SITE SURVEY ELEVATIONS. REFER TO SITE SURVEY
ON SHEET SP000. COORDINATE SITE ELEVATIONS W/
ARCHITECTURAL & STRUCTURAL LEVELS.
INFILL SE CORNER OF SITE.
BOULDER RETAINING AT
PROPERTY LINE AS REQ'D.
PROPERTY LINE
PR
O
PE
RT
Y
LI
N E
PRO
PERTY LIN
E
PROPERTY LINE
TOPSOIL / MULCH MIX INFILL AT
BOULDER PLANTERS
1/4" = 1'-0"1 Grading Plan
NOTE: COORDINATE FINAL GRADING WITH
FOUNDATION WALL HEIGHTS & DETAILS AS
INDICATED ON STRUCTURAL DRAWINGS.
DEMOLITION LEGEND:
WALL TO REMAIN
WALL TO BE DEMO-ED
WINDOW TO BE DEMO-ED
DOOR TO BE DEMO-ED
DEMOLITION AREA
BEAM TO REMAIN
BEAM TO BE DEMO-ED
DEMOLITION NOTES:
1. CONTRACTOR SHALL PERFORM ALL
OPERATIONS OF DEMOLITION AND REMOVAL
AS INDICATED ON THE DRAWINGS AND AS
MAY BE REQUIRED BY THE WORK. ALL WORK
SHALL BE DONE CAREFULLY AND NEATLY,
AND IN A SYSTEMATIC MANNER.
2. ALL EXISTING SURFACES AND EQUIPMENT
TO REMAIN SHALL BE FULLY PROTECTED
FROM DAMAGE. THE CONTRACTOR SHALL
ASSUME FULL RESPONSIBLITY FOR THE
DAMAGE AND SHALL AMKE REPAIRS
REQUIRED WITHOUT ADDITIONAL COST TO
THE OWNER.
3. NO DEBRIS SHALL BE ALLOWED TO
ACCUMULATE ON THE SITE. DEBRIS SHALL BE
REMOVED BY THE CONTRACTOR AS THE JOB
PROCEEDS. THE SITE SHALL BE LEFT FROOM
CLEAN AT THE COMPLETION OF
DEMOLITION.
4. ALL ADJOINING PROPERTY AFFECTED BY
ANY OPERATIONS OF DEMOLITION SHALL BE
PROTECTED PER THE REQUIREMENTS OF
STATE, CITY, AND LOCAL BUIILDING CODES.
5. THE CONTRACTOR SHALL PROVIDE, ERECT
AND MAINTAIN ALL TEMPORARY PARTITIONS,
BARRIERS AND GUARDS, AND ALL
TEMPORARY SHORING AND BRACING AS
REQUIRED.
6. THE CONTRACTOR SHALL PROVIDE
ADEQUATE WEATHER PROTECTION FOR THE
BUILDING AND ITS CONTENTS DURING THE
COURSE OF WORK. ALL OPENINGS IN ANY
WALL OR ROOF SHALL BE PROTECTED FROM
ALL FORMS OF WEATHER OR WATER
PENETRATION.
7. CONTRACTOR TO VERIFY IN THE FIELD AND
REPORT DISCREPANCIES TO THE ARCHITECT.
DEMOLITION DRAWINGS ARE APPROXIMATE
AND NOT LIMITED TO THE AREAS SHOWN.
FILED OBSERVATION IS REQUIRED BY THE
CONTRACTOR TO DETERMINE THE EXTENT OF
THE DEMOLITION WORK.
8. CONTRACTOR TO COORDINATE WITH
OTHER TRADES FOR DEMOLITION WORK TO
BE PERFORMED.
9. THE CONTRACTOR SHALL FILE ALL
NECESSARY CERTIFICATES OF INSURANCE
WITH THE BUILDING DEPARTMENT, PAY ALL
FEES, OBTAIN ALL PERMITS AND PROVIDE
ANY AND ALL BONDS REQUIRED BY ANY CITY
AGENCY IN ORDER TO CARRY OUT THE WORK
HERIN DESCRIBED.
D
EM
O
DEMO
Drawn By:
BLACK MOUNTAIN
ARCHITECTURE, PLLC
D100
1 / 2 5 / 2 0 2 3
16 Academy St.
Saranac Lake, NY 12983
518.354.8340 (p)
NOTES
#CADTechnician
Demo Plans
Demolition Plans
A ca de m y
St re et S ar an ac L ak e
N ew
Y or k
Bl ac k M ou nt ai n
Pr op er ty
M an ag em en t, LL
C
C O
N
ST
RU
C
TI
O
N D
O C
U M
EN
TS
S
ET
SI
G
N
ED
A N
D S
EA
LE
D P
LA
N
S
TO
B E
U
SE
D F
O R
PE
RM
IT
TI
N G
A N
D C
O N
ST
RU
C
TI
O N
P U
RP
O
SE
S
B
LA
C
K M
O U
N
TA
IN
A
RC
H
IT
EC
TU
RE
DEMO ALL INTERIOR PARTITIONS,
FLOORS, CEILINGS, FINISHES, MEP
SYSTEMS, FIXTURES & EQUIPMENT
DEMO ALL EXTERIOR STOREFRONT, WINDOWS &
DOORS, STRUCTURE & CLADDING
DEM
O R
OOF S
TR
UCTU
RE
FI
NISH
ES
1/4" = 1'-0"1 Demolition Plan 1/4" = 1'-0"2 Roof Demo Plan
STRUCTURAL STEEL NOTES:
BASIS OF DESIGN:
1. DESIGN CODES
A. 2020 BUILDING CODE OF NEW YORK STATE
B. IBC (INTERNATIONAL BUILDING CODE) 2018
C. ASCE 7-16 (MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES)
2. DESIGN DEAD LOADS
A. ROOF DEAD LOAD - 20 psf + 10 psf SOLAR ALLOWANCE B. FLOOR DEAD LOAD - 20 psf
C. MECHANICAL/ELECTRICAL UNIT WEIGHTS - PER UNIT LOADING DESIGN
3. DESIGN LIVE LOADS
A. OFFICE BUILDINGS - 50 psf B. PARTITIONS - 15 psf
4. SNOW LOAD
A. GROUND SNOW LOAD - 92 psf B. ROOF SNOW LOAD USE 71 psf FLAT ROOF C. SNOW EXPOSURE FACTOR, Ce - 1.0
D. SNOW LOAD IMPORTANCE FACTOR, IS - 1.0
E. THERMAL FACTOR, Ct - 1.0
F. SLOPED ROOF FACTOR, CS - 1.0
G. PLUS DRIFTING AS APPLICABLE
5. RAIN LOAD
A. ROOF RAIN LOAD = 7 psf
6. WIND LOAD
A. ULTIMATE DESIGN WIND SPEED Vult - 106 mph B. NOMINAL DESIGN WIND SPEED Vasd - 82 mph
C. RISK CATEGORY - II
D. WIND EXPOSURE - B
E. BASIC DESIGN WIND PRESSURE - 17 psf
F. INTERNAL PRESSURE COEFFICIENT - +/ - 0.18
7. EARTHQUAKE LOADS
A. SEISMIC IMPORTANCE FACTOR, Ie - 1.00
B. SEISMIC USE GROUP - II
C. MAPPED SPECTRAL RESPONSE ACCELERATIONS - Ss - 47.5%g , S1 - 10.0%g
D. SITE CLASS - D
E. SPECTRAL RESPONSE COEFFICIENTS, SDS AND SD1, 0.450 AND 0.160
F. SEISMIC DESIGN CATEGORY - C
G. BASIC SEISMIC FORCE RESISTING SYSTEM - STRUCTURAL STEEL SYSTEMS NOT
SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE
H. DESIGN BASE SHEAR - V=0.124 * WEIGHT
I. SEISMIC RESPONSE COEFFICIENT - 0.150
J. RESPONSE MODIFICATION FACTOR, R - 3
K. ANALYSIS PROCEDURE - EQUIVALENT LATERAL FORCE
8. FOUNDATION BEARING CAPACITY - 2,000 psf ASSUMED
9. STRUCTURAL MATERIAL MANUFACTURER'S UTILIZED FOR DESIGN
A. POWDER ACTUATED FASTENERS, EXPANSION BOLTS, ADHESIVE ANCHORING SYSTEM - HILTI, INC
B. FLOOR, ROOF AND WALL WOOD SHEATHING - ADVANTECH SHEATHING BY HUBER
ENGINEERED WOODS
C. LAMINATED VENEER LUMBER (LVL), PARALLEL STRAND LUMBER (PSL), WOOD I-JOISTS
(TJI) - WEYERHAEUSER COMPANY
D. LIGHT GAUGE METAL CONNECTORS, JOIST HANGERS, TIE DOWNS - SIMPSON STRONG -TIE
FOUNDATION RELATED EARTHWORK:
1. EXCAVATION, BACKFILL AND COMPACTION FOR WITHIN BUILDING FOOTPRINT AND 5 FEET AROUND
BUILDING FOUNDATIONS.
2. ALL MATERIAL SHALL BE REASONABLY FREE FROM SILT, LOAM, CLAY, OR ORGANIC MATTER
MEETING THE FOLLOWING REQUIREMENTS
A. COMPACTED GRANULAR FILL
a. 2 INCH: 90 - 100 % BY WEIGHT PASSING SIEVE
b. NO. 4: 50 - 75 % BY WEIGHT PASSING SIEVE
c. NO. 100: 0 - 12 % BY WEIGHT PASSING SIEVE
d. NO. 200: 0 - 6 % BY WEIGHT PASSING SIEVE
B. WASHED CRUSHED STONE
a. 1 -1/2 INCH: 90 - 100 % BY WEIGHT PASSING SIEVE
b. 3/4 INCH: 0 - 10 % BY WEIGHT PASSING SIEVE
c. NO. 4: 0 - 6 % BY WEIGHT PASSING SIEVE
C. SUITABLE NATIVE SOIL
a. ON SITE SAND OR GRAVEL REASONABLY FREE OF LOAM, SILT, CLAY, OR ORGANIC
MATTER.
b. MAXIMUM 15% BY WEIGHT PASSING NO. 200 SIEVE.
3. EXCAVATE SUBSOIL TO ACCOMMODATE BUILDING FOUNDATIONS. HAND TRIM EXCAVATIONS.
REMOVE LOOSE MATERIAL.
4. NOTIFY ENGINEER A MINIMUM OF 24 HOURS PRIOR TO EXCAVATIONS TO SCHEDULE A REVIEW OF
NATIVE SOIL CONDITIONS. SEE BASIS OF DESIGN FOR MINIMUM FOOTING BEARING CAPACITY
DESIGN.
5. COMPACT DISTURBED LOAD -BEARING SOIL IN DIRECT CONTACT WITH FOUNDATIONS TO ORIGINAL BEARING CAPACITY. PLACE 12 INCHES OF CRUSHED STONE BENEATH BUILDING FOOTINGS IF LOOSE
OR WET SOILS ARE ENCOUNTERED.
6. IF OVER -EXCAVATION OCCURS, REPLACE MATERIAL WITH CRUSHED STONE. OVER -EXCAVATION
MAY ALSO BE REPLACED WITH LEAN CONCRETE WITH ENGINEER'S APPROVAL.
7. PLACE AND COMPACT BACKFILL IN EQUAL CONTINUOUS LAYERS NOT EXCEEDING 8" OF
COMPACTED DEPTH FOR HAND HELD COMPACTION EQUIPMENT AND A MAXIMUM OF 12" INCHES
COMPACTED DEPTH FOR VIBRATORY ROLLERS.
8. MAINTAIN OPTIMUM MOISTURE CONTENT OF BACKFILL MATERIALS TO ATTAIN COMPACTION DENSITY.
9. BACKFILL SIMULTANEOUSLY ON EACH SIDE OF FOUNDATION WALLS.
10. BACKFILL REQUIREMENTS
A. FILL WITHIN BUILDING ENVELOPE -
a. MATERIAL COMPACTED GRANULAR FILL
b. COMPACTION 95% MODIFIED PROCTOR
c. TESTING EVERY OTHER LIFT, EVERY 1000 SF
B. BACKFILL ALONG EXTERIOR OF BUILDING AT FROST WALLS, AND IN FRONT OF RETAINING
STRUCTURES -
a. MATERIAL SUITABLE NATIVE SOIL
b. COMPACTION 90% MODIFIED PROCTOR
c. TESTING EVERY OTHER LIFT, EVERY 1000 SF
C. BACKFILL BEHIND RETAINING AND/OR BASEMENT WALLS, OUTSIDE BUILDING ENVELOPE -
a. MATERIAL COMPACTED GRANULAR FILL
b. COMPACTION 90% MODIFIED PROCTOR
c. TESTING EVERY OTHER LIFT, EVERY 1000 SF
11. GRAVEL BELOW SLABS -
A. MATERIAL COMPACTED GRANULAR FILL
B. COMPACTION 95% MODIFIED PROCTOR
C. TESTING EVERY 1000 SF
CAST IN PLACE CONCRETE NOTES:
1. PERFORM WORK IN ACCORDANCE WITH ACI 301 STANDARDS AND RECOMMENDED PRACTICES.
2. ACQUIRE CEMENT AND AGGREGATE FROM SAME SOURCE FOR ALL WORK.
3. CONFORM TO ACI 305R WHEN CONCRETING DURING HOT WEATHER.
4. CONFORM TO ACI 306R WHEN CONCRETING DURING COLD WEATHER.
5. CEMENTITIOS MATERIAL:
A. CEMENT ASTM C150, TYPE I, GRAY - NORMAL; DO NOT CHANGE SOURCE OF
MANUFACTURER OF CEMENT DURING THE COURSE OF THE WORK.
B. FLY ASH - ASTM C618, CLASS F, MAX 25% ; DO NOT CHANGE SOURCE OF MANUFACTURER
OF CEMENT DURING THE COURSE OF THE WORK.
6. FINE AND COARSE AGGREGATES ASTM C33.
7. WATER CLEAN, POTABLE AND NOT DETRIMENTAL TO CONCRETE.
8. AIR ENTRAINMENT ASTM C260.
9. CHEMICAL ASTM C494 TYPE A - WATER REDUCING.
10. BONDING AGENT SIKA ARMATEC 110 EPOCEM BONDING AGENT, NO -SOLVENT THREE COMPONENT
EPOXY AS MANUFACTURED BY SIKA OR EQUIVALENT.
11. NON -SHRINK GROUT PREMIXED COMPOUND CONSISTING OF NON -METALLIC AGGREGATE, CEMENT, WATER REDUCING AND PLASTICIZING AGENTS; CAPABLE OF DEVELOPING MINIMUM COMPRESSIVE STRENGTH OF 2,400 PSI IN 48 HOURS AND 7,000 PSI IN 28 DAYS; MANUFACTURED BY FIVE STAR
PRODUCTS, INC. OR APPROVED EQUIVALENT.
12. FORM RELEASE AGENT WATER BASED, NON TOXIC, ENVIRONMENTALLY FRIENDLY PRODUCT WHICH
WILL NOT STAIN CONCRETE, OR ABSORB MOISTURE , OR IMPAIR NATURAL BONDING OR COLOR
CHARACTERISTICS OF COATING INTENDED FOR USE ON CONCRETE.
13. MIX CONCRETE IN ACCORDANCE WITH ACI 304. DELIVER CONCRETE IN ACCORDANCE WITH
ASTM C94.
14. THE MIX DESIGN SHALL MEET THE REQUIREMENTS OF ACI 318, CHAPTER 19. INCLUDE THE WATER -
CEMENT RATIO, AIR CONTENT, SLUMP, ADMIXTURES, AND THE PLANT TO BE USED.
15. CONCRETE MIXTURES SHALL CONSIST OF THE APPROPRIATE PROPORTIONS OF PORTLAND
CEMENT, WATER, COARSE AND FINE AGGREGATE, AIR ENTRAINING AGENT AND WATER REDUCING
AGENT FOR THE INTENDED APPLICATION.
16. CONCRETE MIXTURES SHALL CONSIST OF THE APPROPRIATE PROPORTIONS OF PORTLAND
CEMENT, WATER, COARSE AND FINE AGGREGATE, AIR ENTRAINING AGENT AND WATER REDUCING
AGENT FOR THE INTENDED APPLICATION.
A. PROVIDE CONCRETE TO THE FOLLOWING 28 DAY STRENGTH AND EXPOSURE CRITERIA
a. FOUNDATION WALLS, INTEGRAL PIERS AND FOOTINGS (UNSATURATED)
• MINIMUM COMPRESSIVE STRENGTH = 3,500 PSI
• EXPOSURE CATEGORY F1
• MAXIMUM W/C RATIO = 0.55
b. INTERIOR ELEVATED SLABS, SLABS ON GRADE AND INTERIOR ISOLATED PIERS
• MINIMUM COMPRESSIVE STRENGTH = 4,000 PSI
• EXPOSURE CATEGORY F0
• MAXIMUM W/C RATIO = 0.50
B. SLUMP 2-4 INCHES BEFORE ADDITION OF WATER REDUCER, 6-8 INCHES AFTER THE
ADDITION OF WATER REDUCER
C. ADD AIR ENTRAINING AGENT TO NORMAL WEIGHT CONCRETE MIX FOR WORK EXPOSED TO
EXTERIOR PER ACI TABLE 19.3.3.1
17. USE ACCELERATING ADMIXTURES IN COLD WEATHER ONLY WHEN APPROVED BY
ARCHITECT/ENGINEER. USE OF ADMIXTURES WILL NOT RELAX COLD WEATHER PLACEMENT
REQUIREMENTS.
18. USE CALCIUM CHLORIDE SHALL NOT BE PERMITTED.
19. USE SET RETARDING ADMIXTURES DURING HOT WEATHER ONLY WHEN APPROVED BY
ARCHITECT/ENGINEER.
20. PLACE CONCRETE IN ACCORDANCE WITH ACI 301, ACI 318, AND ACI 304.
21. ENSURE REINFORCEMENT, INSERTS, EMBEDDED PARTS, FORMED EXPANSION AND CONTRACTION
JOINTS, ARE NOT DISTURBED DURING CONCRETE PLACEMENT.
22. VAPOR RETARDER - 12 MIL.
A. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND METHODS.
B. REPAIR VAPOR RETARDER DAMAGED DURING PLACEMENT OF CONCRETE REINFORCING.
REPAIR WITH VAPOR RETARDER MATERIAL; LAP OVER DAMAGED AREAS MINIMUM 6 INCHES
AND SEAL WATERTIGHT PER MANUFACTURER'S RECOMMENDATIONS.
23. JOINT FILLER SEPARATE SLABS ON GRADE FROM VERTICAL SURFACES WITH 1/2" SEPARATION
BOARD OR RIGID INSULATION SEE ARCHITECTURAL DRAWINGS.
A. PLACE JOINT FILLER IN FLOOR SLAB PATTERN PLACEMENT SEQUENCE. SET TOP TO
REQUIRED ELEVATIONS. SECURE TO RESIST MOVEMENT BY WET CONCRETE.
24. RIGID INSULATION UNDER SLABS SHALL HAVE THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH:
A. RESIDENTIAL , OFFICE USE, AND RESIDENTIAL GARAGE - 25 PSI
25. JOINT SEALER - ONE PART, ZERO VOC, MOISTURE CURING SILICONE JOINT SEALANT SUITABLE FOR
HIGH MOVEMENT BUILDING JOINT APPLICATIONS.
26. DO NOT INTERRUPT SUCCESSIVE PLACEMENT; DO NOT PERMIT COLD JOINTS TO OCCUR.
27. SCREED SLABS ON GRADE LEVEL, MAINTAINING SURFACE FLATNESS OF MAXIMUM 1/4 INCH IN 10 FT.
28. FLOOR SLABS SHALL BE FINISHED AS FOLLOWS IN ACCORDANCE WITH ACI 301 AS FOLLOWS
A. INTERIOR SURFACES TO RECEIVE CARPETING, RESILIENT FLOORING, SEAMLESS FLOORING, OR THIN SET CERAMIC TILE = STEEL TROWEL FINISH
B. EXTERIOR SURFACES = BROOM FINISH PERPENDICULAR TO PEDESTRIAN TRAFFIC.
C. IN AREAS WITH FLOOR DRAINS, MAINTAIN FLOOR ELEVATION AT WALLS; PITCH SURFACES
UNIFORMLY TO DRAINS AS INDICATED ON DRAWINGS.
D. WALLS AND PIERS
a. EXPOSED VERTICAL SURFACES = FILL TIE HOLES WITH GROUT SLURRY AFTER
REMOVAL OF FORMS TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. RUB
FINISH TO A SMOOTH AND UNIFORM TEXTURE.
29. IMMEDIATELY AFTER PLACEMENT, PROTECT CONCRETE FROM PREMATURE DRYING, EXCESSIVELY
HOT OR COLD TEMPERATURES, AND MECHANICAL INJURY.
30. MAINTAIN CONCRETE WITH MINIMAL MOISTURE LOSS AT RELATIVELY CONSTANT TEMPERATURE FOR
PERIOD NECESSARY FOR HYDRATION OF CEMENT AND HARDENING OF CONCRETE.
31. CURE FLOOR SURFACES IN ACCORDANCE WITH ACI 305, ACI 306, AND ACI 308.
32. LIQUID MEMBRANE -FORMING CURING COMPOUNDS SHALL NOT BE USED ON FLOOR SLABS WHERE
PAINT OR FLOORING IS SCHEDULED WITHOUT DEMONSTRATION THAT THE MEMBRANE CAN BE
REMOVED OR THAT THE MEMBRANE CAN SERVE AS A SATISFACTORY BASE FOR THE LATER
APPLICATION.
CONCRETE REINFORCING NOTES:
1. REINFORCING STEEL ASTM A615, 60 KSI YIELD GRADE; DEFORMED BILLET STEEL BARS.
2. STIRRUP STEEL ASTM A82.
3. WELDED STEEL WIRE REINFORCING (WWR) ASTM A1064 PLAIN TYPE; IN FLAT SHEETS.
4. TIE WIRE MINIMUM 16 GAGE ANNEALED TYPE.
5. CHAIRS, BOLSTERS, BAR SUPPORTS, SPACERS SIZED AND SHAPED FOR STRENGTH AND SUPPORT
OF REINFORCEMENT DURING CONCRETE PLACEMENT CONDITIONS INCLUDING LOAD BEARING PAD
ON BOTTOM TO PREVENT PUNCTURING VAPOR RETARDER.
6. MAINTAIN CONCRETE COVER AROUND REINFORCING AS FOLLOWS
A. WALLS (EXPOSED TO WEATHER OR BACKFILL) - 1 1/2 INCHES
B. FOOTINGS AND CONCRETE FORMED AGAINST EARTH - 3 INCHES
C. SLABS ON FILL - 1 1/2 INCHES
D. ELEVATED SLABS, BEAMS AND INTERIOR COLUMNS - 1 INCH
7. SYNTHETIC STRUCTURAL FIBER REINFORCEMENT PROVIDE SYNTHETIC STRUCTURAL FIBERS
COMPLYING WITH THE FOLLOWING REQUIREMENTS
A. SYNTHETIC STRUCTURAL FIBERS SHALL MEET THE REQUIREMENTS OF ASTM C 1116
B. SYNTHETIC STRUCTURAL FIBERS SHALL BE MADE OF POLYPROPYLENE AND
POLYETHYLENE.
C. SYNTHETIC STRUCTURAL FIBERS SHALL HAVE A MINIMUM LENGTH OF 1.5”
D. SYNTHETIC STRUCTURAL FIBERS SHALL HAVE AN ASPECT RATIO (LENGTH DIVIDED BY THE
EQUIVALENT DIAMETER OF THE FIBER) BETWEEN 80 AND 100.
E. SYNTHETIC STRUCTURAL FIBERS SHALL BE GRACE STRUX 90/40 SYNTHETIC FIBER
REINFORCEMENT.
F. THE MINIMUM ADDITION RATE OF…