SOLICITATION QUESTIONS AND ANSWERS

(As of 01/10/2023)

Contract Opportunities Solicitation 20136794 USBP Yuma Storage Containers w/ 4 Roll Doors

1. Will High cube containers 40’ x 8 ‘ x 9’ 6” high be acceptable as they may have more availability at this time?

Yes.

2. Is the wood floor necessary as an extra or would the original flooring in the container 1-1/8” thick marine plywood be sufficient?

The original 1 1/8” thick marine plywood flooring is acceptable provided the flooring shows no significant signs of wear and tear.

3. Can these be water tight air tight used containers or must they be new? 40ft WWT used containers?

Either used or new is acceptable.

4. What size doors do you want for the roll ups?

Doors shall be sized based on a door size opening of approximately 7’6” H x 7’8”W.

5. How do you want the doors spaced?

Doors must be evenly spaced to create uniform/equal interior dimensions of approximately 8’ High x 9 1/2’ wide”. (Height dimension increased by 1-foot if high cube container is provided)

6. Do you need a specific color?

No.

7. Will they have offloading capabilities at the delivery site?

No. In accordance with Statement of Work (SOW) section 3.2, contractor shall be responsible for all offload tasks and placement as directed by the Yuma Sector point of contact.

8. Is the evaluation based on LPTA or is past performance required. If my company doesn't have past performance, will it just be viewed as "Neutral"?

A quoter will not be evaluated favorably or unfavorably on past performance if the quoter has no record of relevant past performance or for whom information on past performance is not available. Please see Solicitation Attachment 2, provision II.10 (52.212-2 EVALUATION -- COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES (NOV 2021)), for full LPTA evaluation criteria details.

9. Can you please provide details what you mean by sufficient vents? Please provide a size requirement.

A minimum of two 16”x16” air vents with a bug screen per partitioned area on opposite locations to improve air flow.