This document package includes architectural drawings and specifications for upgrading motor control centers at a Department of Veterans Affairs medical facility in Gainesville, Florida. The drawings show existing conditions and proposed work in the facility's basement mechanical rooms, including replacement of motor control centers, switchgear, variable frequency drives, and associated electrical equipment. Offerors are advised that an addendum has been issued in response to a request for information, extending the proposal due date to September 15, 2022. The work is to be performed for the Veterans Health Administration under contract with the Veterans Integrated Service Network 8.

View the file

Other files for this federal contract opportunity

Other files attached to J061--Upgrade Motor Control Centers at BLDG One, newest first.
File Type Posted
SF30 Amendment 36C24822R0166 0003.pdf PDF
180-19-EP722.pdf PDF
RFIs 573-19-615.xlsx XLSX spreadsheet
180-19-EP723.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

K.3

MECHANICAL

ROOM

FB29-1

ELECT.

FB30-1

UP

K.3

STAIR

#8

MECHANICAL

ROOM

FB29-1

ELECT.

FB30-1

N

FLOOR PLAN - FB29-1 - NEW WORK

N

EXISTING & DEMOLITION PLAN - FB29-1

ELECTRICAL PLANS - FB29-1

3603 NW 98th Street, Suite B Gainesville, FL 32606 Phone: (352) 474-6124 Fax: (352) 553-4437

QBO: FL #29758

AKEA Design Project No. AD180-19 RAH KLL / KS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved: Project Director

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

321 4 5 6 7 8 9 10

UPGRADE MOTOR CONTROL

CENTERS AT BUILDING 1

GAINESVILLE, FLORIDA

573-19-615

MARCH 23, 2022Revisions: Date:

Design, Inc.

Office of Construction and Facilities Management

ARCHITECT / ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

BID DOCUMENTS

(FOR CONSTRUCTION)

BID DOCUMENTS

EP-105

SHEET NOTES

SHEET KEYNOTES

N

KEY PLAN - BLDG 1 BASEMENT

STATE OF

P R

O

FES S IO NA L ENGIN

E E

R

R O

BER T A . HA FFEM

A

NNo. 66321 L I C E N S E

F L O R I D A

AutoCAD SHX Text

1-RF1

AutoCAD SHX Text

MCC-GB

AutoCAD SHX Text

STORM DRAIN

AutoCAD SHX Text

FIRE/SPRINKLER

AutoCAD SHX Text

CONDENSATE PIPE

AutoCAD SHX Text

HIGH PRESSURE STEAM

AutoCAD SHX Text

COLD WATER SUPPLY

AutoCAD SHX Text

COLD WATER RETURN

AutoCAD SHX Text

VFD

AutoCAD SHX Text

1-RF4

AutoCAD SHX Text

SF5

AutoCAD SHX Text

SIEMENS

AutoCAD SHX Text

1-SF4

AutoCAD SHX Text

CONTROLS

AutoCAD SHX Text

1-RF3

AutoCAD SHX Text

SIEMENS CAB

AutoCAD SHX Text

1-RF2

AutoCAD SHX Text

1-SF3

AutoCAD SHX Text

VFD

AutoCAD SHX Text

DISC. SW.

AutoCAD SHX Text 1-P9

AutoCAD SHX Text

CNTRL PNL

AutoCAD SHX Text

MCC-GA

AutoCAD SHX Text

1-SF1

AutoCAD SHX Text

ATS EQ3B

AutoCAD SHX Text

ATS EQ3C

AutoCAD SHX Text

US-5

AutoCAD SHX Text

PNL H-GA

AutoCAD SHX Text

SIEMENS

AutoCAD SHX Text

CONTROLS

AutoCAD SHX Text

SIEMENS CAB

AutoCAD SHX Text

1-RF2

AutoCAD SHX Text

1-SF3

AutoCAD SHX Text

VFD

AutoCAD SHX Text

DISC. SW.

AutoCAD SHX Text

VFD

AutoCAD SHX Text

1-RF4

AutoCAD SHX Text

SF5

AutoCAD SHX Text

1-SF4

AutoCAD SHX Text

1-RF3

AutoCAD SHX Text

SIEMENS

AutoCAD SHX Text

CONTROLS

AutoCAD SHX Text

CONDENSATE PIPE

AutoCAD SHX Text

HIGH PRESSURE STEAM

AutoCAD SHX Text

COLD WATER SUPPLY

AutoCAD SHX Text

COLD WATER RETURN

AutoCAD SHX Text

STORM DRAIN

AutoCAD SHX Text

FIRE/SPRINKLER

AutoCAD SHX Text

1-RF1

AutoCAD SHX Text

CNTRL PNL

AutoCAD SHX Text

1-SF1

AutoCAD SHX Text 1-P9

AutoCAD SHX Text

ATS EQ3B

AutoCAD SHX Text

ATS EQ3C

AutoCAD SHX Text

US-5

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 1/8" = 1' - 0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text 1/8" = 1' - 0"

AutoCAD SHX Text This item has been electronically signed and sealed by the individual named at right. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.

AutoCAD SHX Text

ENGINEER-OF-RECORD

AutoCAD SHX Text

ROBERT A. HAFFEMAN

AutoCAD SHX Text 66321

AutoCAD SHX Text

FL. P.E. NO.

AutoCAD SHX Text

A. NOT USED.NOT USED.

AutoCAD SHX Text

1. NOT USED NOT USED

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

NTS

AutoCAD SHX Text

PNL H-GB

AutoCAD SHX Text

PROJECT AREA

AutoCAD SHX Text DEDUCTIVE ALTERNATIVE #1 WORK SHOWN IN THIS DOMAIN SHALL BE DEDUCTIVE ALTERNATIVE #1

Sheets and Views
EP105

File details come from the government source that posted it. Updated .