140L3625Q0015_Specifications.pdf
PDF 108 KB Posted
- Attached to
- EMDD HELITACK OFFICE TRAILERS Federal contract opportunity
- Solicitation number
- 140L3625Q0015
About this file
This is a Solicitation Specification document for the Bureau of Land Management (BLM) seeking installation of two temporary mobile offices to support two 11-person helitack crews. The mobile office units must be 10' x 32' to 10' x 36' in size and include specific requirements such as emergency exits compliant with local Fire Marshall regulations, natural lighting through windows, single phase 120/220v 100-amp electrical hookups, and insulated walls, floors, and ceilings.
Each mobile office must feature an electric HVAC system, an enclosed office area with desk space for two personnel, a larger commons area for the crew, and ADA-compliant stairs. The units will be positioned next to a government-supplied electrical panel. Vendors are requested to submit quotes and identify any additional rules or regulations that BLM employees must follow. The solicitation is specifically for the EMDD Helitack Office Trailers, issued under solicitation number 140L3625Q0015 by the Department of the Interior Bureau of Land Management.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140L3625Q0015_Amd_0001.pdf | ||
| Sol_140L3625Q0015.pdf | ||
| 140L3625Q0015_Schedule_of_Items-Price_Schedule.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation #: 140L3625Q0015
Specifications
Installation of two (2) temporary mobile offices that would support the needs of two 11-person helitack crews (22 total personnel), and that meet local, state, and federal health and safety requirements.
Level and anchor the two mobile offices next to a government-supplied electrical panel.
Each mobile office unit shall include the following:
o be between 10’ x 32’ and 10’ x 36’.
o possess functional ingress/egress emergency exits that meet federal, state, and local regulations, and that comply with local Fire Marshall office.
o possess an adequate number of windows to provide natural lighting.
o possess single phase 120/220v 100-amp electrical hookups.
o be constructed with insulated walls, floors, and ceilings.
o possess an electric HVAC heating and air conditioning system.
o provide 1 office area with door that closes to provide privacy and includes desk top space for 2 personnel, and a larger commons area for crew.
o provide stairs that are compliant with the Americans Disability Act (ADA).
If there are any additional rules and regulations that need to be adhered to by the BLM employees, please submit these with your quote.