Fire_Alarm_Inspection_Report_06_02_21_0001.pdf

PDF 539 KB Posted

Attached to
Fire Alarm Testing and Maintenance Federal contract opportunity
Solicitation number
140D8122Q0002
Issued by
Department of the Interior Departmental Offices Interior Business Center

View the file

Other files for this federal contract opportunity

Other files attached to Fire Alarm Testing and Maintenance, newest first.
File Type Posted
AWWU_Report_06_02_21_0001.pdf PDF
Sprinkler_Inspection_Report_06_02_21_0001.pdf PDF
Amended_Exhibit_1_0001.pdf PDF
Main_Bldg_Hangar_2nd_Floor_0001.pdf PDF
Secondary_Hangar_0001.pdf PDF
Sol_140D8122Q0002_Amd_0001.pdf PDF
Main_Bldg_Hangar_1st_Floor_0001.pdf PDF
B03_WD_2015-5681_Rev_14.pdf PDF
Sol_140D8122Q0002.pdf PDF
B08_SOL_140D8122Q0002_Fire_Alarm_Mx.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Office of Aviation Services

No.

07155 www.gocanvas.com 9980416A-0C21-4C5B-8A85-1956637A844A

5887 E. Blue Lupine Dr.

Palmer, , AK 99645

907-373-1760 www.taylorfire.com

Fire Alarm Inspection Report Status

Status

Date

06/02/2021 Time

13:13

Owner /Client / Contracting Agency

Name

Office of Aviation Services Address 1

4405 Lear Court Address 2

City

Anchorage State

AK

Zip

99502

Representative

Bryant Telephone

907-382-1781 Fax

Email

Property Name (User)

Name

Office of Aviation Services Address 1

4405 Lear Court Address 2

Anchorage City

Anchorage State

Contact

Bryant Telephone

907-382-1781 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link

No.

07155 www.gocanvas.com 9980416A-0C21-4C5B-8A85-1956637A844A

AK

Zip

AK

Monitoring Entity

Contact / Agency

TYCO

Telephone

Monitoring Account Ref. No.

023749745

Approving Agency

Contact

Bryant Telephone

907-382-1781

Service

Service

Annually Other (Specify)

Prior To Any Testing Notifications Are

Made To Other (Specify) Yes/No Who Time

Monitoring Entity Yes 13:15 Fire Department Yes 13:15

Type Transmission

Type Transmission

Digital Other (Specify)

Control Panel

Control Panel Manufacturer

Simplex Control Panel Model

Control Panel Location

Entry

Is Panel in "normal" conditions upon arrival?

Yes Circuit Styles

Slc Number of Circuits

Software Rev.

Last Date System Had Any Service Performed

Last Date that Any Software or Configuration Was Revised

No.

07155 www.gocanvas.com 9980416A-0C21-4C5B-8A85-1956637A844A

Printer

Printer Model

None Location

Did Printer Function Properly

Is Printer Supervised?

Alarm-Initiating Devices and Circuit Information Description If Other

(Specify) Quantity of

Devices Installed

Quantity of Devices Tested

Quantity of Devices Passed

Quantity of Devices

Failed

Circuit Style

Manual Fire Alarm Boxes

15 15 15

Smoke Detectors 52 52 52 Heat Detectors 6 6 6 Waterflow Switches

1 1 1

Supervisory Switches

2 2 2

Other Beam detectors 2 2 2

Alarm Verification

Alarm Verification feature is

Alarm Notification Appliances & Circuit Info Description If Other

(Specify) Quantity of Appliances

Installed

Quantity of Appliances

Tested

Quantity of Devices Passed

Quantity of Devices

Failed

Circuit Style

Horn/Strobes 53 53 52 1 Bells 1 1 1 Horns 1 1 1 Decibel Levels

Location Description Ambient Level Alarm Level Office areas 96db

Alarm Notification Circuits

No. of alarm notification appliance circuits

Are circuits monitored for integrity?

Yes

Control Equipment Description of

Equipment If Other (Specify)

Quantity Installed

Quantity Tested Quantity Passed Quantity Failed

Elevator Recall 2 2 2 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link

No.

07155 www.gocanvas.com 9980416A-0C21-4C5B-8A85-1956637A844A

Initiating Device Circuit

Quantity

N/A Style(s)

Signaling Line Circuits

Quantity and style of signaling line circuits connected to system (see 2007 NFPA 72, Table 6.6.1) Quantity

Style(s)

System Primary Power Supply

(a) Primary (Main) Location (of Primary Supply Panelboard)

Electrical room panel 1b ckt 23 Nominal Voltage

Amps

Overcurrent Protection Type

Overcurrent Protection Amps

Disconnecting Means Location

Secondary (standby) Power Supply Type Location Battery

Dated:

Storage Battery:

Amp Hour Rating

Battery Type

Other Battery

Type

Calculated capacity in Amp-Hours to operate system for 24 hours.

Calculated capacity in Amp-Hours to operate system for 60 hours.

Control Panel In panel 2019 12ah Sealed Lead- Acid

Booster Panel

1fl electrical 2019 7ah Sealed Lead-

Booster Panel

2nd floor electrical

2018 7ah Sealed Lead-

Secondary (standby) Power Primary Power Supply Location of

Primary Power Supply

(Distribution Panel)

Nominal Voltage of Primary Power

Supply

Amps of Primary Power Supply

Overcurrent Protection Type

Overcurrent Protection Amps

Disconnecting Means Location

Generator System http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link

No.

07155 www.gocanvas.com 9980416A-0C21-4C5B-8A85-1956637A844A

Engine-driven generator dedicated to fire alarm system.

Location of fuel storage:

Other Backup

(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:

Emergency system described in NFPA 70, Article 700

Legally required standby described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701

Transient Suppressors

Transient Suppressors Visual

Comments

Central Station Monitoring Type of Signal Yes/No Time Comments

Alarm Signal Yes 13:21 Notifications That Testing is Complete Notification Given

To Other (Specify) Yes/No Who Time

Building Management Yes 13:21 Monitoring Agency Yes 13:22

Deficiencies and Issues

The following did not operate correctly

Horn strobe just inside office 208 did not sound during alarm.

Recommend replacement System restored to normal operation

Date

06/02/2021 Time

13:22 http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link

No.

07155 www.gocanvas.com 9980416A-0C21-4C5B-8A85-1956637A844A

Pictures

Photo 1

Photo 1 Description

Alarm panel

Photo 2

Photo 2 Description

Location of horn strobe that failed

Photo 3

Photo 3 Description

Model number of horn strobe needing replacement

Notes and Recommendations

Notes and Recommendations

Could not test beam detectors with filters as they were not on site. Tested with remote test stations underneath beam detectors Plan of Corrective Action:

Corrective Action and Date Taken:

Inspector Information http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link

No.

07155 www.gocanvas.com 9980416A-0C21-4C5B-8A85-1956637A844A

This testing was performed in accordance with (Standard/Edition)

Nfpa 72-2019 Name of Inspector

Robert Doehler License Number

13-021

Date

06/02/2021 Time

13:24

Inspector Signature

Inspector Signature

Owner or Representative Information

Name of Owner or Representative

Bryant Date

06/02/2021

Time

13:24

Owner or Representative Signature

Owner or Representative Signature http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link http://www.gocanvas.com/?utm_source=canvas_pdf&utm_medium=pdf_link&utm_campaign=canvas_pdf_link

File details come from the government source that posted it. Updated .