13449800- material order data.pdf

PDF 123 KB Posted

Attached to
ELECTRODE Federal contract opportunity
Solicitation number
SPMYM2-22-P-0749
Issued by
Defense Logistics Agency Land and Maritime

About this file

This document contains a solicitation for electrodes and related ordering data. The solicitation is seeking quotes for electrodes in accordance with specification MIL-E-23765/2E, including type MIL-100S-1 electrodes in coil form with a 3/32 inch size. Level A packaging and Level C packing is required, as well as special marking per the specification. The ordering data provides additional requirements for the copper and phosphorus content, mechanical properties, and stress-relieved testing. Quotes are due to the Defense Logistics Agency Land and Maritime and must include the offeror's cage code or DUNS number, SAM registration status, pricing FOB Destination to Bremerton, Washington, lead time, manufacturer details, and a signed copy of the solicitation.

View the file

Other files for this federal contract opportunity

Other files attached to ELECTRODE, newest first.
File Type Posted
22-Q-0749 SOLICITATION.pdf PDF
13349801- CDRL.pdf PDF
13349800 - CDRL.pdf PDF
13349801- material order data.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MATERIAL ORDERING DATA

MIL-E-23765/2

IDN: N4523A 1344-9800

ICN: 38PAA56601 KO: S01 KOI: 007

Paragraph 6.2 Ordering Data

A. MIL-E-23765B, ELECTRODES AND RODS- WELDING, BARE, SOLID AND ALLOY

CORED; GENERAL SPECIFICATION FOR, dated 22 AUGUST 1985, including AMENDMENT 1, dated 15 SEPTEMBER 1989.

B. MIL-E-23765/2E, ELECTRODES AND RODS - WELDING, BARE, SOLID, OR ALLOY

CORED; AND FLUXES, LOW ALLOY STEEL, dated 22 APRIL 1994.

C. TYPES: MIL-100S-1

FORMS: Form 3c - Electrode wound on coils with support SIZES: 3/32 inch

D. First article test is not required.

E. Alloy identity testing of each electrode or rod after final marking is not is required F. Length of rods required: N/A G. Level A packaging and Level C packing is required.

H. Special marking per the spec is required.

Additional Requirements:

N/A

MIL-E-23765/2E Paragraph 6.2 Ordering Data

A. The copper and phosphorus content should not be restricted.

B. Whether higher maximum yield strength is allowed: N/A C. The required mechanical properties for type MIL-120s test welds, which have been stress-relieved: N/A D. Time at the stress relief temperature shall be per spec.

E. Whether type MIL-100s or MIL-120s weld metal test plates should be tested for conformance with stress-relieved requirements: N/A.

F. Which specific brand name electrode and flux combination(s) shall be used for conformance testing: N/A G. Other base metal steel for use in testing in the stress-relieved condition, if required: no other base metal steels are required.

H. A second test weldment is not required for quality conformance testing in the as-welded condition.

I. Whether bags and drums shall be palletized for shipment: N/A.

J. Shielding gas required for GMAW shall be: N/A.

Figure 3, Note 3: The neutral granular flux for the SAW process shall be in accordance with 4.2.1 or 4.2.3 herein which is consistent with MIL-type electrodes being tested:

MIL-100S-1F

QPL Applies.

Additional Requirements:

N/A

Prepared By: Jordan Mize Code: Code 260V

File details come from the government source that posted it. Updated .