Amendment 0002_Final.docx
DOCX document 36 KB Posted
- Attached to
- Bulk Helium Supply and Fill Service Federal contract opportunity
- Solicitation number
- 1333ND24QNB610174
About this file
This document is an Amendment 0002 to a Request for Quote (RFQ) for Bulk Helium Supply & Services, Solicitation Number 1333ND24QNB610174. The amendment provides responses to six questions submitted by potential offerors. The key details include:
The RFQ is for the Department of Commerce's National Institute of Standards and Technology (NIST) to procure bulk helium supply and fill services. The NIST has a bank of 6 helium storage tubes with a total water volume of 372.75 cubic feet. The tubes have a maximum allowable working pressure (MAWP) of 2400 psig and must be filled to 2200 psig. The contractor does not need to provide a hose as one is already attached to the fill connection. The minimum operating pressure is 150 psig, and the NIST's helium storage tanks are ASME-certified. All other terms and conditions of the RFQ remain unchanged.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 0001.docx | DOCX document | |
| Pricing Table.docx | DOCX document | |
| PPQ.pdf | ||
| Provisions_Clauses_.pdf | ||
| Experience Project Data Sheet.docx | DOCX document | |
| CSS_SOW_Bulk Helium.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT 0002
Request for Quote (RFQ): 1333ND24QNB610174 Title: Bulk Helium Supply & Services Date: 06/26/24 Purpose: Provide Government’s response to submitted questions
QUESTION 1: When the Helium Transport comes there to refill the Ground Tubes at Building 235, is there a hose there for us to use or do we need to bring one?
RESPONSE 1: There is a hose attached to the fill connection; Airline Hydraulics Part# 3R8008108208SG-240. The hose to trailer adapter is a CGA 1450 connection. The Contractor may recommend a different hose and connection adapter.
QUESTION 2: If we need to bring one, what are the fittings on the Tubes that we need to connect too?
RESPONSE 2: The Contractor does not need to bring a hose with fittings to perform fills.
QUESTION 3: What is the MAWP of the bank and piping?
RESPONSE 3: The Safety Valves on the bulk Helium tubes relieve at 2400 psig. NIST requires the Bulk Helium Tubes to be filled to 2200 psig on each fill.
QUESTION 4: How many tubes are in each bank?
RESPONSE 4: NIST has a bank of 6 tubes with a water volume of 62.125 cubic feet each for a total of water volume of 372.75 cubic feet in the bank.
QUESTION 5: What is the minimum pressure to operate?
RESPONSE 5: 150 psig.
QUESTION 6: Please advise if the customer owned storage is ASME or DOT.
RESPONSE: The NCNR’s Helium storage tanks are ASME
All other terms and conditions remain unchanged and in full force and effect.
END OF AMENDMENT