076200_-_SHEET_METAL_FLASHING_AND_TRIM.pdf
PDF 118 KB Posted
- Attached to
- Bogard Engine Bay Roof Installation Federal contract opportunity
- Solicitation number
- 129AC718Q0061
About this file
076200
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 129AC718Q0061_Amendment_1.pdf | ||
| WD_CA180009_27Jul18.pdf | ||
| 129AC718Q0061.pdf | ||
| Project_Location_Map.pdf | ||
| 074113_-_METAL_ROOF_PANELS.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Copyright 2013 AIA MasterSpec Small Project 10/13
SHEET METAL FLASHING AND TRIM 076200 - 1
SECTION 076200 - SHEET METAL FLASHING AND TRIM
1.1 SECTION REQUIREMENTS
A. Submittals: Product Data, and Shop Drawings.
B. Coordinate installation of sheet metal flashing and trim with adjoining roofing and wall materials, joints, and seams to provide a leak-proof, secure, and noncorrosive installation.
C. Fabricator Qualifications: For copings and low-slope roof edge flashings that are SPRI ES-1 tested and FM Approvals approved, shop shall be listed as able to fabricate required details as tested and approved.
D. Warranty on Finishes: Manufacturer agrees to repair or replace sheet metal flashing and trim that shows evidence of deterioration of factory-applied finishes within 20 years.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Standard: Comply with NRCA's "The NRCA Roofing Manual" unless otherwise indicated.
Conform to dimensions and profiles shown unless more stringent requirements are indicated.
B. FM Approvals' Listing: Manufacture and install roof edge flashings that are listed in FM
Approvals' "RoofNav" and approved for windstorm classification, Class 1-60. Identify materials with name of fabricator and design approved by FM Approvals.
C. SPRI Wind Design Standard: Manufacture and install roof edge flashings tested according to
SPRI ES-1 and capable of resisting the following design pressure:
1. Design Pressure: 30 psf.
2.2 SHEET METAL
A. Metallic-Coated Steel Sheet: Galvanized steel sheet, ASTM A 653/A 653M, G90 (Z275);
0.022-inch (0.56-mm) nominal thickness.
1. Finish: Manufacturer's standard two-coat fluoropolymer system with color coat containing not less than 70 percent PVDF resin by weight.
2.3 ACCESSORIES
A. Felt Underlayment: ASTM D 226, Type II (No. 30), asphalt-saturated organic felts.
B. Slip Sheet: Rosin-sized building paper, 3-lb/100 sq. ft. (0.16-kg/sq. m) minimum.
Copyright 2013 AIA MasterSpec Small Project 10/13
SHEET METAL FLASHING AND TRIM 076200 - 2
C. Fasteners: annular-threaded nails, self-tapping screws, self-locking rivets and bolts, and other suitable fasteners according to manufacturer’s recommendation.
1. Exposed Fasteners: Heads matching color of sheet metal roofing using plastic caps or factory-applied coating.
D. Butyl Sealant: ASTM C 1311, solvent-release butyl rubber sealant.
2.4 FABRICATION
A. Fabricate sheet metal flashing and trim to comply with roof manufacturer’s recommendations for design, dimensions, geometry, thickness and other characteristics.
B. Expansion Provisions: Where lapped expansion provisions cannot be used, form expansion joints of intermeshing hooked flanges, not less than 1 inch (25 mm) deep, filled with butyl sealant concealed within joints.
C. Fabrication Tolerances: Fabricate sheet metal flashing and trim that are capable of installation to tolerances specified in MCA's "Guide Specification for Residential Metal Roofing."
PART 3 - EXECUTION
3.1 INSTALLATION
A. Comply with cited sheet metal standards. Allow for thermal expansion; set true to line and level. Install Work with laps, joints, and seams permanently watertight and weatherproof;
conceal fasteners where possible.
B. Sealant Joints: Where movable, nonexpansion-type joints are required, form metal to provide for proper installation of elastomeric sealant according to cited sheet metal standard.
C. Seams: Fabricate nonmoving seams with flat-lock seams.
D. Metal Protection: Where dissimilar metals contact each other, protect against galvanic action or corrosion by painting contact surfaces with bituminous coating.
END OF SECTION 076200
File details come from the government source that posted it.