1121-05 (042-B51) - Cables - Drawing_93893-B.PDF

PDF 201 KB Posted

Attached to
Cables Federal contract opportunity
Solicitation number
N0017824Q6656
Issued by
Department of the Navy Naval Sea Systems Command

About this file

This combined synopsis and solicitation from the Department of the Navy seeks cable assemblies from Carlisle Interconnect Technologies as the incumbent supplier. The Naval Surface Warfare Center Dahlgren Division intends to procure cable assemblies per drawing number 93893 on a brand name basis from Carlisle, as the assemblies are part of existing weapon systems and redesigning them for a new supplier would significantly increase technical and programmatic risks. Interested suppliers must be able to meet a deadline of 31 January 2024 to submit fixed price quotes for shipping the cable assemblies to Dahlgren, Virginia. The award determination will be based on lowest price technically acceptable and is targeted to be made by 29 February 2024.

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REVINSPECTIONLOCATIONCCs

SUMMATION OF CCs

CRITICAL MAJOR MINOR

CLASSIFICATION OF CHARACTERISTICS (CCs)

CLASSIFICATION OF CHARACTERISTICS (CCs)

DISTRIBUTION STATEMENT D. DISTRIBUTION AUTHORIZED TO DEPARTMENT OF DEFENSE

AND THEIR CONTRACTORS: ADMINISTRATIVE/OPERATIONAL USE: 06 AUGUST 2008

OTHER REQUESTS FOR THIS DOCUMENT SHALL BE REFERRED TO NSWCDD,

ANTENNA PRODUCTION AND TESTING FACILITY, BLDG 1530.

CONTROLLED BY: DEPARTMENT OF THE NAVY

CONTROLLED BY: NSWCDD, B51

CUI CATEGORY: CTI; EXPT

DISTRIBUTION/DISSEMINATION CONTROL: DISTRIBUTION D

POC: BRENT STEFFEY, B51, 540-653-0300

DISTRIBUTION STATEMENT D - DISTRIBUTION AUTHORIZED TO DEPARTMENT OF DEFENSE

AND THEIR U.S. DOD CONTRACTORS ONLY: CRITICAL TECHNOLOGY; EXPORT CONTROLLED:

1/5/2023. OTHER REQUESTS SHALL BE REFERRED TO COMMANDER, DAHLGREN DIVISION,

NAVAL SURFACE WARFARE CENTER, 17320 DAHLGREN RD, DAHLGREN VA 22448-5100.

WARNING - WARNING -THIS DOCUMENT CONTAINTS TECHNICAL DATA WHOSE EXPORT IS

RESTRICTED BY THE ARMS EXPORT CONTROL ACT (SECTION 2751 OF TITLE 22, UNITED

STATES CODE) OR THE EXPORT CONTROL REFORM ACT OF 2018 (CHAPTER 58 SECTIONS

4801-4852 OF TITLE 50, UNITED STATES CODE). VIOLATIONS OF THESE EXPORT LAW ARE

SUBJECT TO SEVERE CRIMINAL PENALTIES. DISSEMINATE IN ACCORDANCE WITH

PROVISIONS OF DOD DIRECTIVE 5230.25 AND DOD INSTRUCTIONS 2040.

DESTRUCTION NOTICE - FOR UNCLASSIFIED, LIMITED DISTRIBUTION

DOCUMENTS DESTORY BY ANY METHOD THAT WILL PREVENT DISCLOSURE OF

CONTENTS OR RECONSTRUCTION OF THE DOCUMENT.

CUI

CUI

FIND

NO.

QTY

REQD

CAGE

CODE PART NUMBER NOMENCLATURE OR DESCRIPTION MATERIAL

OR NOTE

PARTS LIST

4 1 93508 2 WAY TO 8 WAY, CABLE ASSEMBLY

3 1 93507 J3, CABLE ASSEMBLY

2 1 93506 CROSSOVER, CABLE ASSEMBLY

1 1 93505 J2, CABLE ASSEMBLY

REVISIONS

REV DESCRIPTION DATE APPROVED

A ADDED NOTE 5.

B ADDED NOTE 6.

N/A

93893

INTERPRET DRAWING IAW ASME Y14.100

.03 .010 --

T.ROLLINS 09-08-23

DWG NO.

93893

G64

SH REV1 B

CAD MAINTAINED. CHANGES

SHALL BE INCORPORATED BY

THE DESIGN ACTIVITY.

8 7 6 5 4 3 1

D

C

B

A

D

C

B

A

8 7 6 5 4 3 2 1

B-07609NEXT ASSY USED ON

APPLICATION DO NOT SCALE THIS DRAWING

MATERIAL:

REMOVE BURRS AND BREAK SHARP

EDGES .03 MAX

INSIDE CORNERS R .03 MAX.

SURFACE ROUGHNESS 125

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

GENERAL TOLERANCES

ANGLESXXX DECIMALSXX DECIMALS

ENGR

CHECKED

DRAWN

APPROVED FOR DATE

SIZE CAGE CODE

D

GIN DWG NO. REV

SCALE: WEIGHT: SHEET

DEPARTMENT OF THE NAVY

PHASE MATCHED, 4 SET,

CABLE ASSEMBLY

NAVAL SURFACE WARFARE CENTER

DAHLGREN DIVISION

17320 DAHLGREN RD

DAHLGREN, VA 22448-5000

C:\Sokha Backup\_Q53\Q53\Projects\B52\Solidworks-Goodman Files\AS-4127A\NSWC DWG'S\ 93893 Monday, January 30, 2023 9:56:14 AM sokha.pann

ENGR

NOTES:

1. CABLE ASSEMBLIES SHALL HAVE A MAXIMUM INSERTION LOSS OF .48 dB FOR FIND NO. 1, .25 FOR FIND NO. 2, .34 FOR FIND NO. 3, 1.03 FOR FIND NO. 4 AND A MAXIMUM

VSWR OF 1.2:1 IN THE 0.960 TO 1.215 GHz BAND.

2. ASSEMBLY OF CONNECTORS WITH CABLE SHALL CONFORM WITH MANUFACTURER'S

SPECIFICATIONS. GASKETS SHALL BE IN ALL CONNECTORS.

3. CABLE ASSEMBLY, FIND, NO. 1, 2 AND 3, WHEN CONNECTED TOGETHER

SHALL BE THE SAME PHASE LENGTH WITHIN 2 AT 1.0 GHz OF FIND NO. 4

CABLE ASSEMBLY.

4. INTERPRET DIMENSIONS AND TOLERANCING IAW Y14.5M-1994.

5. SUGGESTED SOURCE OF SUPPLY:

CARLISLE INTERCONNECT TECHNOLOGIES

2400 GRAND AVE.

LONG BEACH, CA. 90815

VOICE: 1-360-696-7427

OR 1-877-864-8735 (VANCOUVER)

OR 1-562-494-0955 (LONG BEACH)

FAX: 1-360-694-9230

6. BEND RADIUS SHOULD NOT EXCEED 20X DIAMETER OF CABLE IN ORDER

TO MAINTAIN PROPER PHASE.

AS-

4127A/URC-

107(V)

09-10-06STR

09-10-06D. MASON

Sheet1
Drawing View14
Drawing View15
Drawing View17
Drawing View19

File details come from the government source that posted it. Updated .