100 DWG FY22 Replace Damaged and Leaking Roofs_643 746_042822.pdf
PDF 5 MB Posted
- Attached to
- Roof Replacement BLDGs 643 and 746 Federal contract opportunity
- Solicitation number
- W911SG22B0032
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| OF 1419A2 B0032.pdf | ||
| OF 1419 B0032.pdf | ||
| OF 1419A B0032.pdf | ||
| Sign in Roster 643 and 746.pdf | ||
| W911SG22B0032 0002 SOLICITATION AMENDMENT CONFORM COPY.pdf | ||
| W911SG22B0032 0002 SOLICITATION AMENDMENT MOD COPY.pdf | ||
| MOD W911SG22B0032 0001.pdf | ||
| Wage Determination DBA.pdf | ||
| Conform W911SG22B0032 0001.pdf | ||
| Solicitation W911SG22B0032.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D E S C R
IP
TI
O N
M A R K
D A
TE
D P
W
FO
R T
B
LI
SS
MERRITT ROAD
TAYLOR ROAD PL
EA
SO
N
TO
N
R O
A D
H O
LB
R
O O
K A
V E.
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
SPEC. #
AutoCAD SHX Text W.O. #
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NUMBER:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS
AutoCAD SHX Text
BUILDING 643 ROOF REPLACEMENT
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A-100
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
FORT BLISS, TEXAS
AutoCAD SHX Text
INDEX OF DRAWINGS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
CONCURRENCES
AutoCAD SHX Text
USING AGENCY
AutoCAD SHX Text
FIRE DEPARTMENT
AutoCAD SHX Text
ENVIRONMENTAL DIVISION
AutoCAD SHX Text
PHYSICAL SECURITY OFFICER
AutoCAD SHX Text
ANTI-TERRORISM/FORCE PROTECTION
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
SIGNATURES INDICATE THAT THOSE SIGNING HAVE REVIEWED PROJECT
AutoCAD SHX Text
PLANS AND SPECIFICATIONS AND ARE IN CONCURRENCE WITH THEM.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SAFETY OFFICER
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NEC
AutoCAD SHX Text
DATE
AutoCAD SHX Text
MASTER PLANNING DIVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
OPERATIONS & MAINTENANCE DIVISION
AutoCAD SHX Text
INDUSTRIAL HYGIENE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHIEF, ENGINEERING SERVICES DIVISION, DPW
AutoCAD SHX Text
CHIEF, DESIGN BRANCH, ESD, DPW
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
BUILDING 643 ROOF REPLACEMENT PROJECT
AutoCAD SHX Text
PROJECT LOCATION MAP
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT LOCATIONS
AutoCAD SHX Text 1 = COVER SHEET 2 = SITE LOCATION MAP 3 = DEMOLITION WORK PLAN 4 = NEW WORK PLAN 5 = DETAILS 6 = DETAILS (CONT.)
AutoCAD SHX Text A.F.
AutoCAD SHX Text C.V.R.
AutoCAD SHX Text A.F.
AutoCAD SHX Text
BLDG. 643
AutoCAD SHX Text
FE-00499-5J
AutoCAD SHX Text 04/28/2022
N
E S C R
IP
TI
O N
M A R K
D A
TE
D P
W
FO
R T
B
LI
SS
MERRITT ROAD
PL
EA
SO
N
TO
N
R O
A D
AutoCAD SHX Text
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text
SCALE: 1/32" = 1'-0"
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
SPEC. #
AutoCAD SHX Text W.O. #
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NUMBER:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS
AutoCAD SHX Text
EXISTING SITE PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A-101
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text A.F.
AutoCAD SHX Text A.F.
AutoCAD SHX Text
BLDG. 643
AutoCAD SHX Text 0'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 32'
AutoCAD SHX Text C.V.R.
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text CONSTRUCTION LIMITS - CONSTRUCTION AREA TO USE DEMARCATION POINTS SUCH AS FENCING, CURBS, ETC., WHEREVER FEASIBLE UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
REMOVE EXISTING ROOF SYSTEM
AutoCAD SHX Text LAY DOWN YARD TO BE SUBMITTED BY CONTRACTOR AND APPROVED BY COR & MASTER PLANNING
AutoCAD SHX Text
GENERAL NOTES (EXISTING CONDITIONS)
AutoCAD SHX Text
UTILITY NOTES
AutoCAD SHX Text
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, WHETHER INDICATED ON THE DRAWING OR NOT, TO VERIFY THE LOCATION, DEPTH, AND CONDITION OF ALL EXITING UTILITIES AND SUBSTRUCTURES AND PROTECT THEM FROM ANY DAMAGE. 2. THE CONTRACTOR SHALL CONTACT ALL THE UTILITY COMPANIES AND CONDUCT ALL NECESSARY FIELD INVESTIGATIONS PRIOR TO ANY EXCAVATION. ANY DAMAGE TO EXISTING UTILITIES SHALL BE PROMPTLY REPAIRED BY THE CONTRACTOR AT NO EXPENSE TO GOVERNMENT. 3. NOTIFY THE DPW REPRESENTATIVE IN WRITING AT LEAST 14 NOTIFY THE DPW REPRESENTATIVE IN WRITING AT LEAST 14 DAYS BEFORE ANY UTILITY OUTAGE OR ROAD CLOSURE.
AutoCAD SHX Text
LAY-DOWN AREA NOTES
AutoCAD SHX Text
1. LAY-DOWN AREA SHALL BE DESIGNATED PRIOR TO THE START LAY-DOWN AREA SHALL BE DESIGNATED PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL COORDINATE WITH DPW MASTER PLANNING. 2. THE CONTRACTOR SHALL RESTORE ANY ACCESS ROADS AND THE CONTRACTOR SHALL RESTORE ANY ACCESS ROADS AND LAY-DOWN AREAS USED BACK TO THEIR ORIGINAL STABILIZED CONDITION OR BETTER. 3. CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT AND SUPPLIES REQUIRED TO SECURE THE TEMPORARY STORAGE AREA.
AutoCAD SHX Text
1. CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA AS PER CONTRACT AND SAFETY RECOMMENDATIONS. 2. CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL FOR AREA ADJACENT TO CONSTRUCTION AREA. CONTRACTOR CONTRACTOR SHALL PROVIDE ALL REQUIRED TRAFFIC CONTROL PLANS. ALL SIGNS, BARRICADES, CHANNELIZATION DEVICES, SIGN FRAMES AND ERECTION OF SUCH DEVICES SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL TRAFFIC CONTROL AUTHORITY. 3. BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. PROVIDE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. PROVIDE ACCESS/TEMPERATURE COOLING/HEATING IF NECESSARY DURING PERIODS AC AND HEATER ARE DOWN. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. 4. CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING SPACES. 5. ALL WORK SHALL COMPLY WITH ALL MANUFACTURER'S ALL WORK SHALL COMPLY WITH ALL MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL REGULATIONS/CODES. 6. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 7. NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF FIRE HYDRANTS. 8. ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS MATERIALS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER REPRESENTATIVE PRIOR TO CONTINUING ANY ADDITIONAL WORK. 9. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO EXISTING ELECTRICAL CONDUIT, GAS LINES, WIRES, ETC., AS REQUIRED TO ALLOW FOR CONSTRUCTION. 10. CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS AND FINISHES THAT ARE TO REMAIN, AND WITHOUT NECESSARY DAMAGE. ANY DAMAGES SHALL BE REPLACED OR RESTORED WITHOUT ADDITIONAL COST TO THE GOVERNMENT. 11. ALL REMOVED EQUIPMENT SHALL BE REINSTALLED AND ALL REMOVED EQUIPMENT SHALL BE REINSTALLED AND TESTED IN THE PRESENCE OF A CONTRACTING OFFICER REPRESENTATIVE. 12. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION WASTE AND DEMOLITION MATERIALS AND DEBRIS BE RECYCLED. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION FOR APPROVAL 13. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITIES BEFORE COMMENCING WORK. 14. PRIOR TO CONSTRUCTION START, CONTRACTOR SHALL PRIOR TO CONSTRUCTION START, CONTRACTOR SHALL CONDUCT A THOROUGH PHOTOGRAPHIC SURVEY OF THE SITE. CRACKED SIDEWALKS, BROKEN WINDOWS, BENT EQUIPMENT, ETC. THIS INCLUDES INVENTORY OF ALL ITEMS ON SITE AND THEIR CONDITION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RESPONSIBILITY TO REPAIR. 15. ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE DAMAGED DUE TO NEW WORK IN PROGRESS, SHALL BE PATCHED AND REPAIRED AS REQUIRED. 16. EXISTING SITE IMPROVEMENTS DAMAGED BY THE CONTRACTOR EXISTING SITE IMPROVEMENTS DAMAGED BY THE CONTRACTOR SHALL BE REMOVED AND REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 17. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD VIA RFI, ASAP TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 18. CONTRACTOR SHALL UTILIZE ALL CONSTRUCTION DOCUMENTS, CONTRACTOR SHALL UTILIZE ALL CONSTRUCTION DOCUMENTS, SCOPE, CONTRACT, SPECIFICATIONS, AND DRAWINGS TO ENSURE ALL CONSTRUCTION, DELIVERABLES, AND RESOURCES ARE DELIVERED TO THE GOVERNMENT. 19. PRIOR TO ANY CHANGE OR MODIFICATION TO THESE PRIOR TO ANY CHANGE OR MODIFICATION TO THESE DRAWINGS DUE TO ACTUAL CONDITIONS, DPW REPRESENTATIVE SHALL BE NOTIFIED FOR REVIEW AND APPROVAL.
AutoCAD SHX Text
CONSTRUCTION LIMITS
AutoCAD SHX Text
BUILDING 643 ROOF REPLACEMENT
AutoCAD SHX Text
FE-00499-5J
AutoCAD SHX Text
LAY DOWN AREA
S C R
IP
TI
O N
M A R K
D A
TE
D P
W
FO
R T
B
LI
SS
N
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
SPEC. #
AutoCAD SHX Text W.O. #
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NUMBER:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS
AutoCAD SHX Text
DEMOLITION WORK PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A-102
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text 0'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 32'
AutoCAD SHX Text A.F.
AutoCAD SHX Text A.F.
AutoCAD SHX Text
AutoCAD SHX Text
DEMOLITION PLAN
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"
AutoCAD SHX Text C.V.R.
AutoCAD SHX Text
DEMOLITION GENERAL NOTES
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
EXISTING PIPE PENETRATIONS
AutoCAD SHX Text
EXISTING VENT PENETRATIONS
AutoCAD SHX Text
EXISTING ELECTRICAL PENETRATIONS
AutoCAD SHX Text
EXISTING DOWNSPOUT
AutoCAD SHX Text
EXISTING ELECTRICAL PENETRATIONS
AutoCAD SHX Text
DEMOLITION KEY NOTES
AutoCAD SHX Text 1.
AutoCAD SHX Text REMOVE EXISTING SHINGLE ROOF SYSTEM IN ITS ENTIRETY SHINGLE ROOF SYSTEM IN ITS ENTIRETY ROOF SYSTEM IN ITS ENTIRETY DOWN TO STRUCTURAL DECK. CLEAN AND PREPARE SURFACE FOR NEW ROOF SYSTEM.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 5.
AutoCAD SHX Text
EXISTING ROOF SYSTEM
AutoCAD SHX Text EXISTING, HISTORIC RIDGE VENT TO REMAIN, REMOVE EXISTING FLASHING, AND PREPARE FOR NEW FLASHING, TYPICAL. PROTECT DURING CONSTRUCTION.
AutoCAD SHX Text EXISTING PIPE PENETRATION, REMOVE EXISTING FLASHING, AND PREPARE FOR NEW FLASHING, TYPICAL.
AutoCAD SHX Text SCRAPE AND REMOVE LOOSE PAINT ON EXPOSED WOOD DECK SOFFIT, EAVES AND FASCIA. TYPICAL AT ALL ROOFS. PREPARE FOR PAINT.
AutoCAD SHX Text EXISTING MECHANICAL EQUIPMENT AND EQUIPMENT STAND, REPLACE ROOF CURB WHERE NECESSARY. CONTRACTOR TO FIELD VERIFY AND VALIDATE.
AutoCAD SHX Text
BUILDING 643 ROOF REPLACEMENT
AutoCAD SHX Text
FE-00499-5J
AutoCAD SHX Text
AutoCAD SHX Text
2 TYP.
AutoCAD SHX Text
3 TYP.
AutoCAD SHX Text
3 TYP.
AutoCAD SHX Text
4 TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
2 TYP.
AutoCAD SHX Text
1. THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT REFLECT ALL AVAILABLE INFORMATION, THE EXACT LOCATION AND QUANTITY OF EXISTING DUCTWORK, PENETRATIONS AND EQUIPMENT MAY DEVIATE FROM LOCATIONS AND QUANTITY SHOWN ON DRAWINGS. CONTRACTOR MUST FIELD VERIFY AND EXAMINE EXISTING STRUCTURES, NOTE ALL CONDITIONS AS TO CHARACTER AND EXTENT OF ALL WORK INVOLVED, VALIDATE AND BID ACCORDINGLY. 2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITIES BEFORE COMMENCING WORK. 3. GENERAL CONTRACTOR SHALL ASSURE THAT ALL GENERAL CONTRACTOR SHALL ASSURE THAT ALL SUB-CONTRACTORS HAVE REVIEWED THE ENTIRE SET OF CONSTRUCTION DOCUMENTS, THIS INCLUDES BUT NOT LIMITED TO CONSTRUCTION DRAWINGS, PROJECT MANUAL (SPECIFICATIONS), AMENDMENTS, MODIFICATIONS, AND CHANGE ORDERS. THE CONTRACT IS BASED ON CONSTRUCTION DOCUMENTS AS A WHOLE AND COORDINATION BETWEEN SUBCONTRACTOR IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. THE DEMOLITION PLAN INDICATES THE GENERAL SCOPE OF ITEMS THE DEMOLITION PLAN INDICATES THE GENERAL SCOPE OF ITEMS AND EXISTING CONSTRUCTION ELEMENTS TO BE REMOVED. ANY ADDITIONAL ITEMS ENCOUNTERED IN THESE GENERAL DEMOLITION AREAS, WHICH WILL INTERFERE WITH THE NEW CONSTRUCTION SHALL ALSO BE REMOVED AT NOT ADDITIONAL COST. 5. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 6. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD VIA RFI, ASAP TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 7. CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING DURING CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING DURING CONSTRUCTION AND SHALL PROVIDE ALL REQUIRED BARRICADES, FENCING, COVERED WALKS, PLANKING, LIGHTING, BRACING, SHORING, WARNING SIGNS, ETC. AS REQUIRED BY OSHA AND FORT BLISS REGULATIONS FOR THE PROTECTION OF WORKMEN, STAFF AND USERS. 8. CONTRACTOR SHALL PROTECT ALL GOVERNMENT PROPERTY TO CONTRACTOR SHALL PROTECT ALL GOVERNMENT PROPERTY TO INCLUDE CARS, EQUIPMENT AND BUILDING SYSTEMS. 9. THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS, AND FINISHES THAT ARE TO REMAIN AND WITHOUT UNNECESSARY DAMAGE. ITEMS AND MATERIAL TO BE REMOVED SHALL BE DONE IN SUCH A MANNER AS TO PREVENT DAMAGES TO ITEMS AND MATERIALS THAT REMAIN. SUCH DAMAGES SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE DPW REPRESENTATIVE AND AT NO ADDITIONAL COST TO THE GOVERNMENT. ITEMS INCLUDE BUT ARE NOT LIMITED TO BROKEN CURBS, CRACKED SIDEWALKS, ETC. 10. THE CONTRACTOR SHALL OVERSEE CLEANING AND ENSURE THAT THE CONTRACTOR SHALL OVERSEE CLEANING AND ENSURE THAT THE PREMISES ARE MAINTAINED RUBBISH FREE DURING DEMOLITION WORK. FINAL CLEANUP IS THE RESPONSIBILITY OF THE CONTRACTOR. 11. ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL CODES. 12. THE GOVERNMENT RESERVES THE FIRST RIGHT OF REFUSAL FOR THE GOVERNMENT RESERVES THE FIRST RIGHT OF REFUSAL FOR ALL DEMOLITION ITEMS. THOSE DEMOLITION ITEMS THE GOVERNMENT DOES NOT WISH TO KEEP SHALL BECOME PROPERTY OF THE CONTRACTOR FOR PROPER DISPOSAL. 13. ANY ITEMS SCHEDULED FOR DEMOLITION SUSPECTED TO CONTAIN ANY ITEMS SCHEDULED FOR DEMOLITION SUSPECTED TO CONTAIN HAZARDOUS MATERIALS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE COR PRIOR TO DEMOLITION. 14. CONTRACTOR TO VALIDATE/VERIFY LEAD OR ASBESTOS MATERIAL CONTRACTOR TO VALIDATE/VERIFY LEAD OR ASBESTOS MATERIAL TO BE REMOVED/ABATED. CONTRACTOR SHALL COMPLY WITH ALL REGULATORY REQUIREMENTS APPLICABLE TO LEAD AND ASBESTOS ABATEMENT AS INDICATED IN SURVEYS AND TESTED. 15. CONTRACTOR SHALL IDENTIFY AREAS OF ROOF WHERE ROOF CONTRACTOR SHALL IDENTIFY AREAS OF ROOF WHERE ROOF DECK OR STRUCTURAL REPAIRS ARE NEEDED FOR GOVERNMENT CONSIDERATION. UNLESS NOTED OTHERWISE, CONTRACTOR WILL BID ON AN ESTIMATED 500 SF OF ROOF DECK AREA TO BE REPLACED DUE TO CORROSION AND PROVIDE FULL REPLACEMENT TO INCLUDE STEEL ANGLE REINFORCEMENT SUPPORT AS NEEDED. 16. REMOVE AND REPLACE ALL DAMAGED NAILERS, SOFFIT, AND REMOVE AND REPLACE ALL DAMAGED NAILERS, SOFFIT, AND FASCIA BOARDING TO MATCH EXISTING MATERIALS. 17. CONTRACTOR TO LIFT ALL MECHANICAL EQUIPMENT IN PLACE TO CONTRACTOR TO LIFT ALL MECHANICAL EQUIPMENT IN PLACE TO ALLOW FOR CONSTRUCTION AND REINSTALL ONCE CONSTRUCTION IS COMPLETE. 18. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO ELECTRICAL CONDUIT, GAS LINES, WIRES, ETC., AS REQUIRED TO ALLOW FOR CONSTRUCTION. 19. SECURE AND SAFEGUARD EXISTING AND\OR NEW GAS LINES SECURE AND SAFEGUARD EXISTING AND\OR NEW GAS LINES EXPOSED ON THE ROOF. PRIME WITH ONE COAT AND PROVIDE TWO COATS OF SAFETY YELLOW PAINT. 20. ANY ABANDONED PENETRATIONS SHALL BE REMOVED AND THE ANY ABANDONED PENETRATIONS SHALL BE REMOVED AND THE DECK REPAIRED PRIOR TO INSTALLATION OF THE NEW ROOF SYSTEM. SECURE ALL SLEEVES AND PIPES BEFORE ROOF MATERIAL IS REMOVED. 21. CONTRACTOR WILL FIELD VERIFY BEFORE MOVING ANY CONTRACTOR WILL FIELD VERIFY BEFORE MOVING ANY ABANDONED PENETRATIONS. 22. ALL EQUIPMENT TO BE REMOVED SHALL BE DONE SO IN THE ALL EQUIPMENT TO BE REMOVED SHALL BE DONE SO IN THE PRESENCE OF A GOVERNMENT REPRESENTATIVE AND INSTALLED AND TESTED IN THE PRESENCE OF A GOVERNMENT REPRESENTATIVE. 23. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION AND DEMOLITION MATERIALS AND DEBRIS FROM LANDFILLS. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION. 24. THE CONTRACTOR SHALL NOT EMPLOY FORT BLISS TRASH BINS THE CONTRACTOR SHALL NOT EMPLOY FORT BLISS TRASH BINS TO DISPOSE OF CONSTRUCTION MATERIALS. 25. BURNING ON FORT BLISS PROPERTY IS NOT PERMITTED.BURNING ON FORT BLISS PROPERTY IS NOT PERMITTED.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
S C R
IP
TI
O N
M A R K
D A
TE
D P
W
FO
R T
B
LI
SS
N
AutoCAD SHX Text 386'
AutoCAD SHX Text 386'
AutoCAD SHX Text 38'
AutoCAD SHX Text 38'
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
SPEC. #
AutoCAD SHX Text W.O. #
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NUMBER:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS
AutoCAD SHX Text
NEW WORK PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A-103
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text A.F.
AutoCAD SHX Text A.F.
AutoCAD SHX Text
AutoCAD SHX Text
NEW WORK PLAN
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"
AutoCAD SHX Text C.V.R.
AutoCAD SHX Text
EXISTING PIPE PENETRATIONS
AutoCAD SHX Text
EXISTING VENT PENETRATIONS
AutoCAD SHX Text
EXISTING ELECTRICAL PENETRATIONS
AutoCAD SHX Text
NEW DOWNSPOUT AND CONCRETE SPLASH BLOCK BELOW
AutoCAD SHX Text
EXISTING ELECTRICAL PENETRATIONS
AutoCAD SHX Text
KEY NOTES
AutoCAD SHX Text 1.
AutoCAD SHX Text
NEW WORK GENERAL NOTES
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text EXISTING, HISTORIC RIDGE VENT TO REMAIN. PROVIDE NEW FLASHING AND SEALANT. PAINT WITH ZINC PAINT OR TO MATCH NEW ASPHALT SHINGLE ROOF SYSTEM, TWO COATS.
AutoCAD SHX Text EXISTING PIPE PENETRATION, PROVIDE NEW FLASHING AND SEALANT ACCORDING TO MANUFACTURE'S RECOMMENDATIONS.
AutoCAD SHX Text 7.
AutoCAD SHX Text EXISTING MECHANICAL EQUIPMENT AND EQUIPMENT STAND, INSTALL ROOFING UP AND OVER CURBS AND PROVIDE NEW FLASHING AND SEALANT, TYPICAL.
AutoCAD SHX Text
BUILDING 643 ROOF REPLACEMENT
AutoCAD SHX Text
FE-00499-5J
AutoCAD SHX Text 0'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 32'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
2 TYP.
AutoCAD SHX Text
3 TYP.
AutoCAD SHX Text
3 TYP.
AutoCAD SHX Text
4 TYP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
2 TYP.
AutoCAD SHX Text NEW ASPHALT SHINGLE ROOF SYSTEM AND UNDERLAYMENT. 30 YEAR WARRANTY WITH 130 MPH PEAK GUST WIND SPEED COVERAGE FROM MANUFACTURER. NEW GALVANIZED METAL DRIP EDGE AT ALL ROOF PERIMETERS TO MATCH EXISTING DRIP EDGE DIMENSION.
AutoCAD SHX Text
1. THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT REFLECT ALL AVAILABLE INFORMATION, THE EXACT LOCATION AND QUANTITY OF EXISTING DUCTWORK, PENETRATIONS AND EQUIPMENT MAY DEVIATE FROM LOCATIONS AND QUANTITY SHOWN ON DRAWINGS. CONTRACTOR MUST FIELD VERIFY AND EXAMINE EXISTING STRUCTURES, NOTE ALL CONDITIONS AS TO CHARACTER AND EXTENT OF ALL WORK INVOLVED, VALIDATE AND BID ACCORDINGLY. 2. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, ALL CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITY BEFORE COMMENCING WORK. 3. GENERAL CONTRACTOR SHALL ASSURE THAT ALL GENERAL CONTRACTOR SHALL ASSURE THAT ALL SUB-CONTRACTORS HAVE REVIEWED THE ENTIRE SET OF CONSTRUCTION DOCUMENTS, THIS INCLUDES BUT NOT LIMITED TO CONSTRUCTION DRAWINGS, PROJECT MANUAL (SPECIFICATIONS), AMENDMENTS, MODIFICATIONS, AND CHANGE ORDERS. THE CONTRACT IS BASED ON CONSTRUCTION DOCUMENTS AS A WHOLE AND COORDINATION BETWEEN SUBCONTRACTOR IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 5. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD VIA RFI, ASAP TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 6. CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING DURING CONSTRUCTION AND SHALL PROVIDE ALL REQUIRED BARRICADES, FENCING, COVERED WALKS, PLANKING, LIGHTING, BRACING, SHORING, WARNING SIGNS, ETC. AS REQUIRED BY OSHA AND FORT BLISS REGULATIONS FOR THE PROTECTION OF WORKMEN, STAFF AND USERS. 7. ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL CODES. 8. NO NEW MATERIALS SHALL CONTAIN ASBESTOS, LEAD, OR NO NEW MATERIALS SHALL CONTAIN ASBESTOS, LEAD, OR ANY REGULATED MATERIALS. 9. PROVIDE NEW ASPHALT SHINGLE ROOF SYSTEM AND PROVIDE NEW ASPHALT SHINGLE ROOF SYSTEM AND UNDERLAYMENT. 30 YEAR WARRANTY WITH 130 MPH PEAK GUST WIND SPEED COVERAGE FROM MANUFACTURER. 10. ALL ROOF PENETRATION AND FLASHING WORK SHALL BE THE ALL ROOF PENETRATION AND FLASHING WORK SHALL BE THE RESPONSIBILITY OF ROOFING CONTRACTOR USING MANUFACTURER'S STANDARD DETAILS AND SHALL BE COVERED AS PART OF THE MANUFACTURER'S WARRANTY. CONTRACTOR WILL PROVIDE ALL NEW ACCESSORIES, PIPE SUPPORTS, PIPE BOOTS, CANT STRIPS, ETC. SUPPORTS SHALL NOT PENETRATE THE NEW ROOF SYSTEM. 11. ALL SHEET METAL INCLUDING COPING, GUTTERS, FLASHING, ALL SHEET METAL INCLUDING COPING, GUTTERS, FLASHING, TRIM, LEADER BOXES AND LEADERS ARE TO BE SUPPLIED BY METAL ROOFING MANUFACTURER AND INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. ALL GAUGES OF SHEET METAL SHALL BE ACCORDING TO MANUFACTURERS RECOMMENDATIONS. 12. ALL ROOF AND WALL PANEL TERMINATIONS, COPING, EDGE ALL ROOF AND WALL PANEL TERMINATIONS, COPING, EDGE METAL, SHALL MEET ES-1 STANDARDS. 13. SECURE AND SAFEGUARD EXISTING AND\OR NEW GAS LINES SECURE AND SAFEGUARD EXISTING AND\OR NEW GAS LINES EXPOSED ON THE ROOF. PRIME WITH ONE COAT AND PROVIDE TWO COATS OF SAFETY YELLOW PAINT. 14. CONTRACTOR SHALL IDENTIFY AREAS OF ROOF WHERE ROOF CONTRACTOR SHALL IDENTIFY AREAS OF ROOF WHERE ROOF DECK OR STRUCTURAL REPAIRS ARE NEEDED FOR GOVERNMENT CONSIDERATION. UNLESS NOTED OTHERWISE, CONTRACTOR WILL BID ON AN ESTIMATED 500 SF OF ROOF DECK AREA TO BE REPLACED DUE TO CORROSION AND PROVIDE FULL REPLACEMENT TO INCLUDE STEEL ANGLE REINFORCEMENT SUPPORT AS NEEDED. 15. PROVIDE PRECAST, REINFORCED CONCRETE SPLASHBLOCKS AT PROVIDE PRECAST, REINFORCED CONCRETE SPLASHBLOCKS AT ALL DOWNSPOUTS. 16. PROVIDE AND INSTALL TWELVE, STAINLESS STEEL, MINIMUM PROVIDE AND INSTALL TWELVE, STAINLESS STEEL, MINIMUM 5,000 LB (22.2 kN) TENSILE STRENGTH PERMANENT FALL PROTECTION D-RING TYPE ROOF ANCHORS. ROOF ANCHORS SHALL COMPLY WITH OSHA 1926.502. INSTALL IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 17. REMOVE AND REPLACE ALL DAMAGED NAILERS, SOFFIT, AND REMOVE AND REPLACE ALL DAMAGED NAILERS, SOFFIT, AND FASCIA BOARDING TO MATCH EXISTING MATERIALS. 18. ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE DAMAGED DUE TO NEW WORK IN PROGRESS, SHALL BE PATCHED AND REPAIRED AS REQUIRED. 19. EXISTING SITE DAMAGED BY THE CONTRACTOR SHALL BE EXISTING SITE DAMAGED BY THE CONTRACTOR SHALL BE REMOVED AND REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. ITEMS INCLUDE BUT ARE NOT LIMITED TO BROKEN CURBS, CRACKED SIDEWALKS, ETC. 20. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION AND DEMOLITION MATERIALS AND DEBRIS FROM LANDFILLS. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION. 21. THE CONTRACTOR SHALL NOT EMPLOY FORT BLISS TRASH THE CONTRACTOR SHALL NOT EMPLOY FORT BLISS TRASH BINS FOR DISPOSE OF CONSTRUCTION MATERIALS. 22. BURNING ON FORT BLISS PROPERTY IS NOT PERMITTED.BURNING ON FORT BLISS PROPERTY IS NOT PERMITTED.
AutoCAD SHX Text 6.
AutoCAD SHX Text WALL FLASHING SHOP DRAWINGS TO BE APPROVED BY CONTRACTING OFFICER REPRESENTATIVE AND CULTURAL RESOURCE MANAGER PRIOR TO INSTALLATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
7 TYP.
AutoCAD SHX Text PRIME AND PAINT (TWO COATS) ALL EXISTING, EXPOSED WOOD DECK SOFFIT, EAVES AND FASCIA. COLOR TO BE APPROVED BY CONTRACTING OFFICER REPRESENTATIVE AND CULTURAL RESOURCE MANAGER PRIOR TO WORK.
AutoCAD SHX Text 5.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NEW ASPHALT SHINGLE ROOF SYSTEM AS MANUFACTURED BY OWENS CORNING ROOFING AND ASPHALT, LLC. OR APPROVED EQUAL. PRODUCT NAME: "DURATION" SERIES SHINGLES AND "DURARIDGE" HIP AND RIDGE SHINGLES OR APPROVED EQUAL. COLOR TO MATCH: OWENS CORNING: "ONYX BLACK". PROVIDE A SIX NAIL PATTERN FOR INSTALLATION. SELF-ADHERING UNDERLAYMENT AS MANUFACTURED BY OWENS CORNING ROOFING AND ASPHALT, LLC. OR APPROVED EQUAL. PRODUCT NAME: "TITANIUM PSU30"
AutoCAD SHX Text
NEW FALL PROTECTION ROOF ANCHOR
AutoCAD SHX Text NEW PERMANENT FALL PROTECTION ROOF ANCHOR, REFERENCE GENERAL NOTE #16 THIS SHEET.
SL
OP
E
D E S C R
IP
TI
O N
M A R K
D A
TE
D P
W
FO
R T
B
LI
SS
AutoCAD SHX Text
T- OR L-TYPE DRIP EDGE METAL, SEE NOTE 1SEE NOTE 1
AutoCAD SHX Text
STARTER COURSE
AutoCAD SHX Text
FASTENERS
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
SEALING STRIP
AutoCAD SHX Text
UNDERLAYMENT
AutoCAD SHX Text
1. FOR L-TYPE DRIP EDGE METAL, STARTER COURSE EXTENDS UP TO 3/4" BEYOND THE PERIMETER EDGE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
STARTER COURSE
AutoCAD SHX Text
FASTENERS
AutoCAD SHX Text
UP TO 3/4" OVERHANG WITH L-TYPE DRIP EDGE METAL
AutoCAD SHX Text
GUTTER
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
1. THIS DETAIL SHOWS ONE TYPE OF GUTTER SUPPORT. GUTTER SECUREMENT AND SUPPORT OPTIONS VARY.
AutoCAD SHX Text
L- OR T-TYPE DRIP EDGE METAL
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
SEALING STRIP
AutoCAD SHX Text
UNDERLAYMENT
AutoCAD SHX Text
T- OR L-TYPE DRIP EDGE METAL
AutoCAD SHX Text
FASTENERS
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SEALING STRIP
AutoCAD SHX Text
UNDERLAYMENT
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
T- OR L-TYPE DRIP EDGE METAL
AutoCAD SHX Text
FASTENERS
AutoCAD SHX Text
SEALING STRIP
AutoCAD SHX Text
UNDERLAYMENT
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
STARTER COURSE
AutoCAD SHX Text
1. MOST MANUFACTURERS SUPPLY SPECIAL RIDGE SHINGLES. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
UNDERLAYMENT WRAPPED OVER RIDGE
AutoCAD SHX Text
RIDGE SHINGLES
AutoCAD SHX Text FASTENERS SHOULD BE LONG ENOUGH TO PENETRATE THROUGH ALL LAYERS OF ROOFING MATERIALS AND INTO DECK
AutoCAD SHX Text
SEALING STRIPS
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
UNDERLAYMENT
AutoCAD SHX Text
1. MOST MANUFACTURERS SUPPLY SPECIAL HIP SHINGLES. FOLLOW INSTALLATION INSTRUCTIONS.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text FASTENERS SHOULD BE LONG ENOUGH TO PENETRATE THROUGH ALL LAYERS OF ROOFING MATERIAL AND INTO THE DECK
AutoCAD SHX Text
SEALING STRIP
AutoCAD SHX Text
UNDERLAYMENT WRAPPED OVER HIP
AutoCAD SHX Text
HIP SHINGLE
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
SPEC. #
AutoCAD SHX Text W.O. #
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NUMBER:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A-104
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text A.F.
AutoCAD SHX Text A.F.
AutoCAD SHX Text C.V.R.
AutoCAD SHX Text
BUILDING 643 ROOF REPLACEMENT
AutoCAD SHX Text
FE-00499-5J
AutoCAD SHX Text C1
AutoCAD SHX Text
EAVE DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text C2
AutoCAD SHX Text
EAVE WITH GUTTER DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text C3
AutoCAD SHX Text
RAKE DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text A2
AutoCAD SHX Text
NON-VENTED RIDGE DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text A3
AutoCAD SHX Text
HIP DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text A1
AutoCAD SHX Text
RAKE WITH STARTER COURSE DETAIL
AutoCAD SHX Text
NOT TO SCALE
¾
¾
¾
¾
¾
¾
D E S C R
IP
TI
O N
M A R K
D A
TE
D P
W
FO
R T
B
LI
SS
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
FIELD UNDERLAYMENT AND ROOF DECK NOT SHOWN FOR CLARITY
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
EXTEND SHINGLE 12" MIN. BEYOND CENTER OF VALLEY
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
TRIM CORNER OF SHINGLES
AutoCAD SHX Text
SEALING STRIPS
AutoCAD SHX Text
VALLEY UNDERLAYMENT
AutoCAD SHX Text
2. THE CUT SIDE OF THE VALLEY SHOULD BE ON THE SIDE WITH THE GREATEST ROOF AREA.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
1. NO FASTENERS WITHIN 6 INCHES OF VALLEY CENTER.
AutoCAD SHX Text
SHEET-METAL STEP FLASHING AT EACH COURSE
AutoCAD SHX Text
UNDERLAYMENT TURNED UP WALL
AutoCAD SHX Text
MAINTAIN 1" ABOVE ROOF SURFACE
AutoCAD SHX Text
TWO-PIECE SHEET-METAL COUNTERFLASHING¾ OVERLAP STEP FLASHING MIN. 2"
AutoCAD SHX Text
BUILDING WRAP¾OVERLAP OVERLAP COUNTERFLASHING MIN. 2"
AutoCAD SHX Text
WALL SIDING/CLADDING NOT SHOWN FOR CLARITY
AutoCAD SHX Text
2" MIN.
AutoCAD SHX Text
APPROPRIATE FASTENERS
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
SEALING STRIP
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
1. FOR SECUREMENT AND JOINERY OPTIONS FOR SHEET METAL AND COUNTERFLASHING OPTIONS, REFER TO THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
SEALING STRIP
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
SOFT-METAL FLASHING SLEEVE¾ ROLL INTO PIPE APPROX. 1"
AutoCAD SHX Text
SEALANT UNDER SHINGLES
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
PIPE PENETRATION FLASHING
AutoCAD SHX Text
UNDERLAYMENT
AutoCAD SHX Text LAP UNDERLAYMENT OVER FLASHING OR SEAL UPPER FLANGE TO UNDERLAYMENT WITH ROOF CEMENT
AutoCAD SHX Text LAP UNDERLAYMENT OVER TOP OF FLASHING FLANGE OR SEAL UPPER FLANGE TO UNDERLAYMENT WITH ROOF CEMENT
AutoCAD SHX Text
OPTIONAL: SEALANT
AutoCAD SHX Text
FIELD UNDERLAYMENT AND ROOF DECK NOT SHOWN FOR CLARITY
AutoCAD SHX Text
SHEET-METAL COUNTERFLASHING
AutoCAD SHX Text
SHEET-METAL APRON FLASHING WITH HEMMED EDGE
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
SOLDER OR SEAL CORNERS
AutoCAD SHX Text
SHEET-METAL STEP FLASHING
AutoCAD SHX Text
UNDERLAYMENT TURNED UP WALL
AutoCAD SHX Text
SHEET-METAL COUNTERFLASHING
AutoCAD SHX Text
SHEET-METAL CRICKET FLASHING¾SOLDER OR SEAL SOLDER OR SEAL CORNERS
AutoCAD SHX Text
STEP FLASHING¾BOTH BOTH SIDES OF CHIMNEY
AutoCAD SHX Text
CRICKET FLASHING AT MASONRY CHIMNEY
AutoCAD SHX Text
2. FOR SECUREMENT AND JOINERY OPTIONS FOR SHEET METAL AND COUNTERFLASHING OPTIONS, REFER TO THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING.
AutoCAD SHX Text
1. THIS DETAIL APPLIES TO CHIMNEYS WIDER THAN 24 INCHES.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
APRON FLASHING AT MASONRY CHIMNEY
AutoCAD SHX Text
3" MIN.
AutoCAD SHX Text
LAP UNDERLAYMENT OVER FLASHING
AutoCAD SHX Text
SHEET-METAL COUNTERFLASHING
AutoCAD SHX Text
SHEET-METAL BACKER FLASHING¾ SOLDER OR SEAL CORNERS
AutoCAD SHX Text
STEP FLASHING¾BOTH BOTH SIDES OF CHIMNEY
AutoCAD SHX Text
BACKER FLASHING AT MASONRY CHIMNEY
AutoCAD SHX Text
APRON FLASHING AT MASONRY CHIMNEY
AutoCAD SHX Text
SHEET-METAL APRON FLASHING WITH HEMMED EDGE
AutoCAD SHX Text B
AutoCAD SHX Text
SHEET-METAL COUNTERFLASHING
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text
SOLDER OR SEAL CORNERS
AutoCAD SHX Text
SHEET-METAL STEP FLASHING
AutoCAD SHX Text
UNDERLAYMENT TURNED UP WALL
AutoCAD SHX Text
2. FOR SECUREMENT AND JOINERY OPTIONS FOR SHEET METAL AND COUNTERFLASHING OPTIONS, REFER TO THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING.
AutoCAD SHX Text
1. THIS DETAIL APPLIES TO CHIMNEYS THAT ARE 24 INCHES WIDE OR LESS.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
LAP UNDERLAYMENT OVER FLASHING
AutoCAD SHX Text
ROOF DECK
AutoCAD SHX Text
ROOF SYSTEM EXTENDED ABOVE TRANSITION
AutoCAD SHX Text
SHINGLES HELD BACK 10" MIN.
AutoCAD SHX Text
FIRST COURSE SHALL COVER BASE FLASHING
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
SEALING STRIP
AutoCAD SHX Text
UNDERLAYMENT
AutoCAD SHX Text
STARTER COURSE
AutoCAD SHX Text
ASPHALT SHINGLES
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
SPEC. #
AutoCAD SHX Text W.O. #
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NUMBER:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A-105
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
MUST USE INDICATED SCUPPER
AutoCAD SHX Text
DETAILS (CONT.)
AutoCAD SHX Text A.F.
AutoCAD SHX Text A.F.
AutoCAD SHX Text C.V.R.
AutoCAD SHX Text
BUILDING 643 ROOF REPLACEMENT
AutoCAD SHX Text
FE-00499-5J
AutoCAD SHX Text C4
AutoCAD SHX Text
CLOSED-CUT VALLEY DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text C5
AutoCAD SHX Text
PIECE COUNTER FLASHING DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text C6
AutoCAD SHX Text
VENT PIPE PENETRATION DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text A4
AutoCAD SHX Text
CHIMNEY WITH CRICKET FLASHING DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text A5
AutoCAD SHX Text
(24" WIDE OR LESS) DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text A6
AutoCAD SHX Text
ROOF SYSTEM TRANSITION DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
SIDEWALL FLASHING WITH TWO -
AutoCAD SHX Text
CHIMNEY WITH BACKER FLASHING
AutoCAD SHX Text
STEEP TO LOW SLOPE
E S C R
IP
TI
O N
M A R K
D A
TE
D P
W
FO
R T
B
LI
SS
PL
EA
SO
N
TO
N
R O
A D
H O
LB
R
O O
K A
V
E. CHAFFEE ROAD
CARTER ROAD
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
SPEC. #
AutoCAD SHX Text W.O. #
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NUMBER:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS
AutoCAD SHX Text
BUILDING 746 ROOF REPLACEMENT
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A-100
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text
FORT BLISS, TEXAS
AutoCAD SHX Text
INDEX OF DRAWINGS
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
CONCURRENCES
AutoCAD SHX Text
USING AGENCY
AutoCAD SHX Text
FIRE DEPARTMENT
AutoCAD SHX Text
ENVIRONMENTAL DIVISION
AutoCAD SHX Text
PHYSICAL SECURITY OFFICER
AutoCAD SHX Text
ANTI-TERRORISM/FORCE PROTECTION
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
SIGNATURES INDICATE THAT THOSE SIGNING HAVE REVIEWED PROJECT
AutoCAD SHX Text
PLANS AND SPECIFICATIONS AND ARE IN CONCURRENCE WITH THEM.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SAFETY OFFICER
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NEC
AutoCAD SHX Text
DATE
AutoCAD SHX Text
MASTER PLANNING DIVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
OPERATIONS & MAINTENANCE DIVISION
AutoCAD SHX Text
INDUSTRIAL HYGIENE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHIEF, ENGINEERING SERVICES DIVISION, DPW
AutoCAD SHX Text
CHIEF, DESIGN BRANCH, ESD, DPW
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
BUILDING 746 ROOF REPLACEMENT PROJECT
AutoCAD SHX Text
PROJECT LOCATION MAP
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text N
AutoCAD SHX Text
PROJECT LOCATIONS
AutoCAD SHX Text 1 = COVER SHEET 2 = SITE LOCATION MAP 3 = DEMOLITION WORK PLAN 4 = NEW WORK PLAN 5 = DETAILS 6 = DETAILS (CONT.)
AutoCAD SHX Text A.F.
AutoCAD SHX Text C.V.R.
AutoCAD SHX Text A.F.
AutoCAD SHX Text
BLDG. 746
AutoCAD SHX Text
FE-00497-5J
N
E S C R
IP
TI
O N
M A R K
D A
TE
D P
W
FO
R T
B
LI
SS
CARTER ROAD
H O
LBRO
O
K A
V E.
AutoCAD SHX Text
AutoCAD SHX Text
SITE PLAN
AutoCAD SHX Text
SCALE: 1/32" = 1'-0"
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
SPEC. #
AutoCAD SHX Text W.O. #
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NUMBER:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS
AutoCAD SHX Text
EXISTING SITE PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A-101
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text A.F.
AutoCAD SHX Text A.F.
AutoCAD SHX Text
BLDG. 746
AutoCAD SHX Text 0'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 32'
AutoCAD SHX Text C.V.R.
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text CONSTRUCTION LIMITS - CONSTRUCTION AREA TO USE DEMARCATION POINTS SUCH AS FENCING, CURBS, ETC., WHEREVER FEASIBLE UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
REMOVE EXISTING ROOF SYSTEM
AutoCAD SHX Text LAY DOWN YARD TO BE SUBMITTED BY CONTRACTOR AND APPROVED BY COR & MASTER PLANNING
AutoCAD SHX Text
GENERAL NOTES (EXISTING CONDITIONS)
AutoCAD SHX Text
UTILITY NOTES
AutoCAD SHX Text
1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, WHETHER INDICATED ON THE DRAWING OR NOT, TO VERIFY THE LOCATION, DEPTH, AND CONDITION OF ALL EXITING UTILITIES AND SUBSTRUCTURES AND PROTECT THEM FROM ANY DAMAGE. 2. THE CONTRACTOR SHALL CONTACT ALL THE UTILITY COMPANIES AND CONDUCT ALL NECESSARY FIELD INVESTIGATIONS PRIOR TO ANY EXCAVATION. ANY DAMAGE TO EXISTING UTILITIES SHALL BE PROMPTLY REPAIRED BY THE CONTRACTOR AT NO EXPENSE TO GOVERNMENT. 3. NOTIFY THE DPW REPRESENTATIVE IN WRITING AT LEAST 14 NOTIFY THE DPW REPRESENTATIVE IN WRITING AT LEAST 14 DAYS BEFORE ANY UTILITY OUTAGE OR ROAD CLOSURE.
AutoCAD SHX Text
LAY-DOWN AREA NOTES
AutoCAD SHX Text
1. LAY-DOWN AREA SHALL BE DESIGNATED PRIOR TO THE START LAY-DOWN AREA SHALL BE DESIGNATED PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL COORDINATE WITH DPW MASTER PLANNING. 2. THE CONTRACTOR SHALL RESTORE ANY ACCESS ROADS AND THE CONTRACTOR SHALL RESTORE ANY ACCESS ROADS AND LAY-DOWN AREAS USED BACK TO THEIR ORIGINAL STABILIZED CONDITION OR BETTER. 3. CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT AND SUPPLIES REQUIRED TO SECURE THE TEMPORARY STORAGE AREA.
AutoCAD SHX Text
1. CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA AS PER CONTRACT AND SAFETY RECOMMENDATIONS. 2. CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL FOR AREA ADJACENT TO CONSTRUCTION AREA. CONTRACTOR CONTRACTOR SHALL PROVIDE ALL REQUIRED TRAFFIC CONTROL PLANS. ALL SIGNS, BARRICADES, CHANNELIZATION DEVICES, SIGN FRAMES AND ERECTION OF SUCH DEVICES SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL TRAFFIC CONTROL AUTHORITY. 3. BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. PROVIDE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. PROVIDE ACCESS/TEMPERATURE COOLING/HEATING IF NECESSARY DURING PERIODS AC AND HEATER ARE DOWN. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. 4. CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING SPACES. 5. ALL WORK SHALL COMPLY WITH ALL MANUFACTURER'S ALL WORK SHALL COMPLY WITH ALL MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL REGULATIONS/CODES. 6. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 7. NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF FIRE HYDRANTS. 8. ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS MATERIALS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER REPRESENTATIVE PRIOR TO CONTINUING ANY ADDITIONAL WORK. 9. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO EXISTING ELECTRICAL CONDUIT, GAS LINES, WIRES, ETC., AS REQUIRED TO ALLOW FOR CONSTRUCTION. 10. CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS AND FINISHES THAT ARE TO REMAIN, AND WITHOUT NECESSARY DAMAGE. ANY DAMAGES SHALL BE REPLACED OR RESTORED WITHOUT ADDITIONAL COST TO THE GOVERNMENT. 11. ALL REMOVED EQUIPMENT SHALL BE REINSTALLED AND ALL REMOVED EQUIPMENT SHALL BE REINSTALLED AND TESTED IN THE PRESENCE OF A CONTRACTING OFFICER REPRESENTATIVE. 12. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION WASTE AND DEMOLITION MATERIALS AND DEBRIS BE RECYCLED. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION FOR APPROVAL 13. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITIES BEFORE COMMENCING WORK. 14. PRIOR TO CONSTRUCTION START, CONTRACTOR SHALL PRIOR TO CONSTRUCTION START, CONTRACTOR SHALL CONDUCT A THOROUGH PHOTOGRAPHIC SURVEY OF THE SITE. CRACKED SIDEWALKS, BROKEN WINDOWS, BENT EQUIPMENT, ETC. THIS INCLUDES INVENTORY OF ALL ITEMS ON SITE AND THEIR CONDITION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RESPONSIBILITY TO REPAIR. 15. ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE DAMAGED DUE TO NEW WORK IN PROGRESS, SHALL BE PATCHED AND REPAIRED AS REQUIRED. 16. EXISTING SITE IMPROVEMENTS DAMAGED BY THE CONTRACTOR EXISTING SITE IMPROVEMENTS DAMAGED BY THE CONTRACTOR SHALL BE REMOVED AND REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 17. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD VIA RFI, ASAP TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 18. CONTRACTOR SHALL UTILIZE ALL CONSTRUCTION DOCUMENTS, CONTRACTOR SHALL UTILIZE ALL CONSTRUCTION DOCUMENTS, SCOPE, CONTRACT, SPECIFICATIONS, AND DRAWINGS TO ENSURE ALL CONSTRUCTION, DELIVERABLES, AND RESOURCES ARE DELIVERED TO THE GOVERNMENT. 19. PRIOR TO ANY CHANGE OR MODIFICATION TO THESE PRIOR TO ANY CHANGE OR MODIFICATION TO THESE DRAWINGS DUE TO ACTUAL CONDITIONS, DPW REPRESENTATIVE SHALL BE NOTIFIED FOR REVIEW AND APPROVAL.
AutoCAD SHX Text
CONSTRUCTION LIMITS
AutoCAD SHX Text
LAY DOWN AREA
AutoCAD SHX Text
BUILDING 746 ROOF REPLACEMENT
AutoCAD SHX Text
FE-00497-5J
S C R
IP
TI
O N
M A R K
D A
TE
D P
W
FO
R T
B
LI
SS
N
AutoCAD SHX Text
REVIEWED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
SPEC. #
AutoCAD SHX Text W.O. #
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
NUMBER:
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS
AutoCAD SHX Text
DEMOLITION WORK PLAN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A-102
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AS SHOWN
AutoCAD SHX Text 0'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text 32'
AutoCAD SHX Text A.F.
AutoCAD SHX Text A.F.
AutoCAD SHX Text
AutoCAD SHX Text
DEMOLITION PLAN
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"
AutoCAD SHX Text C.V.R.
AutoCAD SHX Text
DEMOLITION GENERAL NOTES
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
EXISTING PIPE PENETRATIONS
AutoCAD SHX Text
EXISTING VENT PENETRATIONS
AutoCAD SHX Text
EXISTING ELECTRICAL PENETRATIONS
AutoCAD SHX Text
EXISTING DOWNSPOUT
AutoCAD SHX Text
EXISTING ELECTRICAL PENETRATIONS
AutoCAD SHX Text
DEMOLITION KEY NOTES
AutoCAD SHX Text 1.
AutoCAD SHX Text REMOVE EXISTING SHINGLE ROOF SYSTEM IN ITS ENTIRETY SHINGLE ROOF SYSTEM IN ITS ENTIRETY ROOF SYSTEM IN ITS ENTIRETY DOWN TO STRUCTURAL DECK. CLEAN AND PREPARE SURFACE FOR NEW ROOF SYSTEM.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 5.
AutoCAD SHX Text
EXISTING ROOF SYSTEM
AutoCAD SHX Text EXISTING VENT PENETRATION, REMOVE EXISTING FLASHING, AND PREPARE FOR NEW FLASHING, TYPICAL.
AutoCAD SHX Text EXISTING PIPE PENETRATION, REMOVE EXISTING FLASHING, AND PREPARE FOR NEW FLASHING, TYPICAL.
AutoCAD SHX Text EXISTING MECHANICAL EQUIPMENT AND EQUIPMENT STAND, REPLACE ROOF CURB WHERE NECESSARY. CONTRACTOR TO FIELD VERIFY AND VALIDATE.
AutoCAD SHX Text
BUILDING 746 ROOF REPLACEMENT
AutoCAD SHX Text
FE-00497-5J
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
5 TYP.
AutoCAD SHX Text
5 TYP.
AutoCAD SHX Text EXISTING BUILDING EXPANSION JOINT, REPLACE EXPANSION MATERIAL WHERE NECESSARY. CONTRACTOR TO FIELD VERIFY AND VALIDATE.
AutoCAD SHX Text
AutoCAD SHX Text
1. THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT REFLECT ALL AVAILABLE INFORMATION, THE EXACT LOCATION AND QUANTITY OF EXISTING DUCTWORK, PENETRATIONS AND EQUIPMENT MAY DEVIATE FROM LOCATIONS AND QUANTITY SHOWN ON DRAWINGS. CONTRACTOR MUST FIELD VERIFY AND EXAMINE EXISTING STRUCTURES, NOTE ALL CONDITIONS AS TO CHARACTER AND EXTENT OF ALL WORK INVOLVED, VALIDATE AND BID ACCORDINGLY. 2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITIES BEFORE COMMENCING WORK. 3. GENERAL CONTRACTOR SHALL ASSURE THAT ALL GENERAL CONTRACTOR SHALL ASSURE THAT ALL SUB-CONTRACTORS HAVE REVIEWED THE ENTIRE SET OF CONSTRUCTION DOCUMENTS, THIS INCLUDES BUT NOT LIMITED TO CONSTRUCTION DRAWINGS, PROJECT MANUAL (SPECIFICATIONS), AMENDMENTS, MODIFICATIONS, AND CHANGE ORDERS. THE CONTRACT IS BASED ON CONSTRUCTION DOCUMENTS AS A WHOLE AND COORDINATION BETWEEN SUBCONTRACTOR IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. THE DEMOLITION PLAN INDICATES THE GENERAL SCOPE OF ITEMS THE DEMOLITION PLAN INDICATES THE GENERAL SCOPE OF ITEMS AND EXISTING CONSTRUCTION ELEMENTS TO BE REMOVED. ANY ADDITIONAL ITEMS ENCOUNTERED IN THESE GENERAL DEMOLITION AREAS, WHICH WILL INTERFERE WITH THE NEW CONSTRUCTION SHALL ALSO BE REMOVED AT NOT ADDITIONAL COST. 5. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 6. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD VIA RFI, ASAP TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 7. CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING DURING CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING DURING CONSTRUCTION AND SHALL PROVIDE ALL REQUIRED BARRICADES, FENCING, COVERED WALKS, PLANKING, LIGHTING, BRACING, SHORING, WARNING SIGNS, ETC.
This is the start of the file's text. The full file is on GovTribe.