Respirometer Complete System
Added: Jul 13, 2017 11:10 am The US Department of Agriculture, Agricultural Research Service WRRC in Albany CA has a requirement to add to our respirometry capability by the acquisition of a new, complete respirometer system. The addition also includes upgrading our current system in order to bring it up to present-day specifications. The system must meet the following specifications:a. Must use a Closed Loop Measurement Method+ Protected by the following patents• U.S. No. 4947339• European No. 0372429• Japanese No. 2117492b. Must have high sensitivity of up to 2x10·7 liter of gas per hour (0.2 μL/hour) and support thefollowing gases:• 02 (oxygen): 0-1%, 19-21%, 0-100%+ CO2 (carbon dioxide): 0-1%, 0-3%, 0-10%, 0-100%+ CH4 (methane): 0-1%, 0-5%, 0-10%, 0-30%, 0-100%+ CO (carbon monoxide): 0-1%, 0-10%• H2 (hydrogen): 0-2000 ppm• H2S (hydrogen sulfide): 200 ppm+ NO2 (nitric oxide): 150 ppmc. Must be expandable to measure up to 80 samples and be a highly adaptable respirometerthat monitors single or multiple gases contained in an enclosed head space. Must allowcalculations of incremental and accumulated values for consumption and production of gases.The system must be configurable to monitor from one to 80 chambers.d. Must be suitable for meeting the Standardized Aerobic and Anaerobic Tests including: ASTMD5271, ISO 14855, EN 13432 for Plastics in Compost, ASTM D5209 for Plastics in SewageSludge, ASTM D5338 for Plastics in Controlled Compost, ASTM D5988 for Plastics in Soil, ISO14852 for Plastics in Aqueous Medium, ASTM D5210 for Plastics in Sewage Sludge, ASTMD5511 for Plastics under High Solids, and ISO 15985 for Digestione. Multiple Chamber Sensing: 1 to 80 Chambersf. Fully automated operationg. Maximum Head Space Volume: (50ml to l0L m), H2 (0-2000 and 0-10,000ppm).h. Additionally, we'd like to be able to use our current flasks and other disposables that we havefor our current system.The USDA ARS intends on negotiating with the only known source on a sole source bases for a Micro-Oxymax 40 Chamber Complete System from Columbus Instruments International Corporation 950 North Hague Avenue, Columbus, OH 43204-2121. Interested firms may present capability statements. This notice of intent is not a request for competitive proposals. However, all capability statements received within FIVE days after date of publication of this synopsis will be considered by the government. A determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the government reference is made to .FAR PART 13. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. Capability statements are to be sent the attention Fred Gifford as listed in this notice. At the present time funding is not available to support this project and an award may never be made. ag32sds170059 Department of Agriculture Agricultural Research Service Central Program Planning Coordination and Support
Award Notice 1/1 7/13/17, 11:10 AM