6515--Microtome Tissue Processors for Oklahoma City VA Healthcare System
SYNOPSIS DESCRIPTION: The Department of Veterans Affairs, Network Contracting Office (NCO) 19 Rocky Mountain Acquisition Center, 6162 S. Willow Drive, Suite 300, Greenwood Village, CO 80111 intends to solicit sources to enter into a firm-fixed price, to provide (3) Microtromes for the following location: VA Oklahoma City Health Care Systems located at 921 NE 13th St. Oklahoma City, OK 73104 The contractor shall provide 3 (tee) Microtromes with separate control panel and in-housing integrated instrument control panel. The solicitation package will be available for download on or about June 17, 2022, and proposals shall be 14 days after the issuance of the solicitation, and no later than 9:00 a.m. mountain time. The applicable NAICS code is 334516- Analytical Laboratory Instrument Manufacturing with a small business size standard of 1000 employees. This solicitation is Full and Open Competition. The solicitation reference is 36C25922Q0391 VISN 19 OKC Microtomes and should be referenced in all correspondence/ inquiries. The locations for services are stated above. All information for this solicitation will be posted on the Contracting Opportunities (CO) website at www.betasam.gov. No hard copies of the solicitation will be provided. Any amendments to this solicitation will be available at this website and offerors are advised that they are responsible for obtaining amendments to this solicitation at this website prior to the time of responding to the solicitation. Any questions pertaining to the solicitation must be provided to the contract specialist, in writing within 7 days of the posting of the solicitation, at Julie.wright4@va.gov and NCO19Services2@va.gov . This is the pre-solicitation notice only. 36C25922Q0391 Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19
Pre-Solicitation 1/3 6/17/22, 3:46 PM 6640--Microtome Tissue Processors for Oklahoma City VA Healthcare System
Awarded contract 36C25922P0807 to GOVERNMENT SCIENTIFIC SOURCE, INC. for 81820.68000000 on 2022-07-15. 36C25922Q0391 Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19
Award Notice 3/3 7/14/22, 5:13 PM 6515--Microtome Tissue Processors for Oklahoma City VA Healthcare System
Scope: The contractor shall provide 3 (tee) Microtomes with the follow specifications for the VA Oklahoma City Health Care System. General Type: Motorized Nominal Supply Voltage: 100 / 120 / 230 / 240 V AC Nominal Frequency: 50/60 Hz Maximum Power Consumption: 100 VA Protection Class: I Power Fuses: 2 x T 3.15 AL, 250V Pollution Degree: 2 Overvoltage Category: II Maximum Heat Emission: 340 J/s Operating Temperature Range: +18AC to +35AC Temperature Range During Storage: +5AC to +50AC Relative Humidity During Operation: 20% to Max. 80% Non-Condensing Relative Humidity During Storage: 10% to Max. 85% Non-Condensing Dimensions & Weight BASIC INSTRUMENT A Width (including handwheel and coarse feed wheel): 477 mm Depth (including waste tray): 620 mm Height (without top tray): 295 mm Weight (without accessories): Approx. 40 kg CONTROL PANEL A Type: Separate control panel & in-housing integrated instrument control panel Width: 119 mm Depth: 193 mm Height: 50 mm Height (in inclined position): 81 mm Weight (net): 0.6 kg Microtome Performance Specs Specimen Feed: approx. 24 mm A1 mm Vertical Stroke: 70 mm A1 mm A Large Standard Clamp: 55 x 50 x 30 mm Super Cassette Clamp: 68 x 48 x 15 mm Motorized Sectioning Speeds: 0 - 420 mm/s A10% A SPECIMEN RETRACTION A In Manual Sectioning Mode: 5 - 100 Am (in 5 Am increments); can be turned off In Motorized Sectioning Mode: Speed-Dependent; can be turned off A SPECIMEN ORIENTATION A Horizontal: A 8A Vertical: A 8A SECTION THICKNESS SETTINGS A Range: 0.5 - 100 Am Setting Values: 0.5 - 5 Am (in 0.5 Am increments) A 5 - 20 Am (in 1 Am increments) A 20 - 60 Am (in 5 Am increments) A 60 - 100 Am (in 10 Am increments) A TRIMMING SECTION THICKNESS SETTINGS: A Range: 1 - 600 Am Setting Values: 1 - 10 Am (in 1 Am increments) A 10 - 20 Am (in 2 Am increments) A 20 - 50 Am (in 5 Am increments) A 50 - 100 Am (in 10 Am increments) A 100 - 600 Am (in 50 Am increments) Additional Specifications Handwheel Balance System: Handwheel Lock / Brake: 2 Mechanical Locks, 1 Electronic Brake Safety Hand Wheel: Handle can be Centered Coarse Feed Wheel Turn Direction: Clockwise or Counter-Clockwise A WASTE TRAY A Type: Anti-static Waste Tray Volume: 1400 ml A SELECTABLE CUTTING MODES A Rock Mode: A - with activated retraction Single Mode: Continuous Mode: Step Mode: Program Mode: BLADE HOLDER A Type: 2-in 1 for high and low profile blades North-South Movement: A 24 mm East-West Movement: 3 Positions Lateral Displacement Function: via knife holder CE clamping top A SPECIAL FEATURES A Remaining Feed Indicator: Visual and Acoustical 36C25922Q0391 Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19
Solicitation 2/3 6/17/22, 5:08 PM