DRYDOCK REPAIRS - USCGC SITKINAK (WPB 1329) 110 FOOT B CLASS PATROL BOAT.
Added: Nov 17, 2011 4:43 pm The United States Coast Guard is considering whether or not to set aside an acquisition for HUBZone concerns, for Service-Disabled Veteran-Owned Small Business Concerns (SDVOSB) or for Small Business. The small business size standard is less than 1,000 employees. The NAICS Code is 336611. The acquisition is for DRYDOCK repairs to the USCGC SITKINAK (WPB 1329) 110 FOOT "B CLASS" PATROL BOAT.The vessel has a Geographical Restriction of 576 Nautical Miles one-way, or 1,152 Nautical Miles round trip from its homeport in Miami, FL. All work will be performed at the contractor's facility. The performance period will be FIFTY-NINE (59) calendar days with a start date of 25 APR 2012 tough 22 JUN 2012.The scope of the acquisition is for the overhauling, cleaning and repairing of various items aboard the USCGC SITKINAK (WPB 1329). This work will include, but is not limited to:1. Hull Plating, U/W Body, Inspect2. Hull Plating (U/W Body), Ultrasonic Testing 3. Aluminum Hull and Structural Repairs - 1/4" Plate4. Aluminum Hull and Structural Repairs - 3/16" Plate5. Aluminum Hull and Structural Repairs - 5/16" Plate6. Hull and Structural Plating Repairs -Crack (Aluminum) 7. Hull and Structural Plating Repairs - Crack (Steel) 8. Hull and Structural Plating Repairs - Eroded Weld (Aluminum) 9. Steel Hull and Structural Plating Repairs (5-Pound) 10. Steel Hull and Structural Plating Repairs ( 7.0 Pound, 7.5-Pound or 7.65-Pound) 11. Steel Hull and Structural Plating Repairs, Corrugated Plate (4.0-Pound) 12. Hull and Structural Plating Repairs (6.0-Pound or 5.63-Pound)13. Perform Steel Hull and Structural Plating Repairs (10-Pound or 10.2-Pound) 14. Appendages (U/W), Leak Test15. Appendages (U/W) - Internal, Preserve16. Tanks (Fuel Service), Clean and Inspect17. Voids (Non-Accessible), Leak Test18. Tanks (Fuel Stowage and Overflow), Clean and Inspect19. Voids (Non-Accessible), Preserve Internal Surfaces20. Tanks, Air Test21. Tanks (Dirty Oil and Waste), Clean and Inspect22. Propulsion Shafting, Remove, Inspect, and Reinstall23. Mechanical Shaft Seal Assemblies, Overhaul24. Propulsion Shaft Bearings (External), Renew25. Prop ulsion Shaft Stern Tube Bearings, Renew26. Propellers ; Remove, Inspect, and Reinstall27. Exhaust System, MDE , Inspect28. Fathometer Transducer, Renew29. Speed Doppler, Renew, Doppler Valve, Overhaul30. Sea Strainers - Duplex (All Sizes), Overhaul31. Fin Stabilizers (General), Overhaul32. Tanks, (Grey Water) Clean and Inspect33. Forward Void, Preserve34. Tanks (Aft Grey Water), Preserve " 100% " 35. Tanks (Aft Grey Water), Preserve "Partial " 36. Tanks (Dirty Oil ), Preserve " 100% " 37. Tanks (Dirty Oil ) , Preserve " Partial " 38. Tank (Oily Water), Preserve " 100% " 39. Tanks (Oily Water), Preserve " Partial " 40. U/W Body, Preserve "100%41. U/W Body, Preserve "Partial - Condition A " 42. U/W Body, Preserve "Partial - Condition B" 43. U/W Body, Preserve "Partial - Condition C " 44. Cathodic Protection System (Bilge and Sea Chest), Renew45. Drydocking46. Temporary Services, Provide47. Data Service, Provide48. Sea Trial Performance, Provide Support49. CCTV Security System, Install (EC-110-C-111) 50. Sea Valves and Waster Pieces , Overhaul or Renew51. Firemain Valves, Overhaul Or Renew52. Bilge and Ballast Valves, Overhaul or Renew53. Tanks (Potable Water), Clean and Inspect54. Propulsion System , Alignment Check55. SW Heat Exchangers , Clean , Inspect and Hydro56. Rudder Assembly, Remove, Inspect and Reinstall57. Tanks, (Sewage Holding) Clean and Inspect58. Grey Water Piping, Clean and Flush59. Sewage Piping , Clean and Flush60. Forward Peak Compartment, Preserve61. Tanks (Sewage Holding) , Preserve " 100% " 62. Tanks (Sewage Holding) , Preserve " Partial "63. Tanks (Potable Water), Preserve " 100% " 64. Tanks (Potable Water), Preserve " Partial " 65. Bilge Surfaces, Preserve66. Cathodic Protection System, Inspect and Maintain67. Cofferdams, Drain Line, Repair68. Deck Covering (Galley), Renew69. Deck Covering (Shower Stall), Renew70. Hull, Structural, (Magazine Locker), Preserve and Insulate71. Piping, Fuel Oil System, Stripping Line, Renew72. Structural , (Aluminum), Deck Plating , Repairs (CSMP 2011006) 73. Steering Gear (General), Overhaul74. Tanks, Potable Water, Structural RepairsAll welding and brazing shall be accomplished by trained welders who have been certified by the applicable regulatory code performance qualification procedures.In accordance with FAR 19.1305, if your firm is HUBZone certified or FAR 19.1404 if your firm is SDVOSB or FAR 19.501 if your firm is a Small Business and intends to submit an offer on this acquisition, please respond by e-mail to Bradley.S.Lantz@uscg.mil or by fax (757) 628-4628. Questions may be referred to Bradley Lantz at (757) 628-4602.In response please include the following: (a) a positive statement of your intent to submit a bid for this solicitation as a prime contractor; (b) evidence of experience in work similar in type and scope to include contract numbers, project titles, dollar amounts, points of contact and telephone numbers; (c) past performance references with points of contact and phone numbers, at least two references are requested, but more are desirable.Your response is required by November 25, 2011. All of the above must be submitted in sufficient detail for a decision to be made on a HUBZone, SDVOSB or Small Business set aside. Failure to submit all information requested may result in an unrestricted acquisition. A decision on whether this will be pursued as a HUBZone or SDVOSB or a Small Business set aside will be posted on the FedBizOps website at http://www.fedbizopps.gov. HSCG80-12-Q-PHM606 Department of Homeland Security US Coast Guard
Award Notice 1/2 11/17/11, 4:43 PM