Walk-through Ferromagnetic Dual Detector System
Closed Solicitation Posted
- Solicitation number
- 36C25524Q0433
- Agency
- Veterans Integrated Service Network 15 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Place of performance
- Marion, Illinois 62959, United States
- Points of contact
-
- Jon Lutmer jonathan.lutmer@va.gov (410) 446-3862
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration is seeking to procure a walk-through ferromagnetic dual detector system to replace the existing system for notification of MR projectile hazards. The system must have adjustable acoustic and multiple location optical alarm capabilities, operator programmable sensitivity limitation settings, and be compatible with the existing door and power supply configuration. The system must comply with IEC 60601-1-8 AMD2:2020 and IEC 60101-1:2005 medical device specifications. Offerors will be evaluated on their ability to meet the technical requirements and provide on-site training for safe operation and troubleshooting.
This opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses. The place of performance is Marion, IL. No details on potential incumbent contractors or award values are provided, but the required system must accommodate a 72-inch high by 53-inch wide coverage area and be designed to withstand potential impacts from hospital equipment during patient transfers.
Notice text
Statement of Requirement
Replacement including installation of the walk-through ferromagnetic dual detector system with equivalent system for notification of MR projectile hazards.
- Ferromagnetic detection system must have adjustable acoustic and multiple location optical alarm capabilities with technology designed to decrease alarm fatigue and false- positive notifications.
- System shall have operator programable sensitivity limitation settings.
- Detector(s) able to be mounted to entrance doorway of the current design for the magnet room (zone 3). Consideration of structural factors accordant for product include ability to mount on outside of cased opening with a seven (7) inch inset with permanent hardwired sign located eight (8) inches above door frame. The product shall be compatible for door with outswing operation only. See Appendix Basis of Design
- Product design consistent to existing position of power supply at 14 inches from framed casing of door. Must have standard AC power with no special requirements.
- Detector range must accommodate the seventy-two (72) inch high by fifty-three (53) inch wide coverage area.
- Designed to withstand potential impact of hospital equipment during patient transfers with MR safe equipment.
- On-site training for staff shall be provided for safe operation, problem-solving, and information on technical support.
- System must be ferromagnetic detector system designed to alarm on only ferromagnetic objects, shall not accept a metal detector designed to alarm on both ferrous and non- ferrous metal types.
- Complies with IEC 60601-1-8 AMD2:2020
***Conforms to IEC 60101-1:2005 medical device specification requirements (the Ferromagnetic detectors are not considered to be medical devices; however, they are an integral part of the medical environment. As such, it is highly important that the power supply used in the detectors complies with standards for medical equipment used by the FDA, UL, as well as agencies around the world).
Attachments
| File | Type | Posted |
|---|---|---|
| 36C25524Q0433.pdf |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity