Two (2) Laser Based N2O Analyzers for Chassis Testing

Awarded Award Notice Posted

Solicitation number
SOL-CI-14-00017
Agency
Cincinnati Procurement Operations Division Office of Acquisition Management, Environmental Protection Agency
Awarded
to Horiba Instruments Incorporated
Set-aside
No set-aside

Opportunity facts

Contract number
EPC15014 Federal contract award
NAICS code
334516 Analytical Laboratory Instrument Manufacturing
PSC
Not on record
Place of performance
Assessment and Standards DivisionUS Environmental Protection AgencyNational Vehicle and Fuel Emissions2565 Plymouth RoadAnn ArborMI48105USA 48105 USA
More information

Notice details come from SAM.gov. Updated .

Notice text

3 versions

Update #3 · Latest ·

Added: May 08, 2014 10:22 am Modified: Jun 26, 2014 4:07 pmTrack Changes Competitive procurement of two Laser Based N2O Analyzers for EPA/NVFEL Chassis Sites D002 & D005. The EPA seeks to purchase two laser based N2O analyzers to be used in (1) light-duty chassis testing D005 (Site 3 - Room 511) and (2) light-duty chassis testing D002 (Site 1 - Room 515) at the EPA National Vehicle and Fuel Emissions Laboratory in Ann Arbor, MI.

Update #2 ·

Added: May 08, 2014 10:22 am Modified: Jun 23, 2014 12:56 pmTrack Changes ***Amendment*** The purpose of this amendment is to change the solicitation posting date. The solicitation will be posted to FedConnect on or about July 1, 2014.



The U.S. Environmental Protection Agency (EPA), Assessment and Standards Division, National Vehicle and Fuel Emissions Laboratory (NVFEL), Ann Arbor, Michigan, intends to purchase two (2) Laser Based N2O Analyzers with an optional additional analyzer to be used in light -duty chassis testing D005 (Site 3 ? Room 511) and light-duty chassis testing D002 (Site 1 ? Room 515). The acquisition of this Commercial item will be subject to full and open competition and will be processed in accordance with FAR Parts 12 and 13. The North American Industry Classification System (NAICS) code is 334516 Analytical Laboratory Instrument Manufacturing.

Recently, in response to new N2O emission regulations, instrument manufacturers have developed laser based infrared spectrometers in which the source emits infrared radiation in a narrow band width. This, in turn, eliminates the opportunity for interference as the infrared wavelength emitted by the source is focused in the region where N2O absorbs.

One (1) N2O analyzer will be used for continuous and batch analysis of dilute exhaust gas sampled either directly from a CVS (continuous sampling) or a Kynar bag (batch sampling). The system will be installed in light -duty chassis testing D005 (Site 3 ? Room 511) at the NVFEL. This test site is equipped with a Horiba MEXA-One analytical system and Horiba CVS-One sampling system for both continuous and bag analysis of criteria pollutants controlled through a Horiba CDTCS test cell controller.

One (1) N2O analyzer will be used for continuous and batch analysis of dilute exhaust gas sampled either directly from CVS exhaust stream or from Kynar bags. The system shall be installed in a light-duty chassis testing D002 (Site 1 ? Room 515) at the NVFEL. This site is equipped with a MEXA 7200 analytical system and a Horiba CVS-7200 sampling system for both continuous and bag analysis of criteria pollutants. The system is controlled through a Horiba CDTCS test controller.

The full Statement of Work, which will be included in the solicitation, describes and sets forth the installation and analyzer requirements for the two (2) N20 analyzers and other optional items. The equipment implementation described in the full Statement of Work shall allow for the integration and the ability to fully control the analyzer functions, and data collection, processing and reporting in keeping with the minimum requirements of current operations, while meeting the requirements of 40 CFR Part 86 & 1065/1066 in terms of features, performance, usage requirements, and calibration/verification requirements. Award will be made on a Best Value Basis. All non-price evaluation criteria, when combined, are significantly more important than price. Anticipated non-price evaluation criteria include demonstrated ability of the proposed system to meet or exceed the SOW requirements; past performance record under comparable contracts; and relevant previous experience. The solicitation should be issued on or about May 26, 2014 on FedConnect.net. This office does not intend to mail hard copies of the solicitation.

All responsible sources may submit a proposal which shall be considered by the Agency. Point of Contact for this requirement is Gerold Young, Contract Specialist, at (513) 487-2660, or by email at young.gerold@epa.gov. Questions must be submitted in writing to Gerold Young via email. Telephone queries will not be honored.

Update #1 ·

Added: May 08, 2014 10:22 am The U.S. Environmental Protection Agency (EPA), Assessment and Standards Division, National Vehicle and Fuel Emissions Laboratory (NVFEL), Ann Arbor, Michigan, intends to purchase two (2) Laser Based N2O Analyzers with an optional additional analyzer to be used in light -duty chassis testing D005 (Site 3 ? Room 511) and light-duty chassis testing D002 (Site 1 ? Room 515). The acquisition of this Commercial item will be subject to full and open competition and will be processed in accordance with FAR Parts 12 and 13. The North American Industry Classification System (NAICS) code is 334516 Analytical Laboratory Instrument Manufacturing.

Recently, in response to new N2O emission regulations, instrument manufacturers have developed laser based infrared spectrometers in which the source emits infrared radiation in a narrow band width. This, in turn, eliminates the opportunity for interference as the infrared wavelength emitted by the source is focused in the region where N2O absorbs.

One (1) N2O analyzer will be used for continuous and batch analysis of dilute exhaust gas sampled either directly from a CVS (continuous sampling) or a Kynar bag (batch sampling). The system will be installed in light -duty chassis testing D005 (Site 3 ? Room 511) at the NVFEL. This test site is equipped with a Horiba MEXA-One analytical system and Horiba CVS-One sampling system for both continuous and bag analysis of criteria pollutants controlled through a Horiba CDTCS test cell controller.

One (1) N2O analyzer will be used for continuous and batch analysis of dilute exhaust gas sampled either directly from CVS exhaust stream or from Kynar bags. The system shall be installed in a light-duty chassis testing D002 (Site 1 ? Room 515) at the NVFEL. This site is equipped with a MEXA 7200 analytical system and a Horiba CVS-7200 sampling system for both continuous and bag analysis of criteria pollutants. The system is controlled through a Horiba CDTCS test controller.

The full Statement of Work, which will be included in the solicitation, describes and sets forth the installation and analyzer requirements for the two (2) N20 analyzers and other optional items. The equipment implementation described in the full Statement of Work shall allow for the integration and the ability to fully control the analyzer functions, and data collection, processing and reporting in keeping with the minimum requirements of current operations, while meeting the requirements of 40 CFR Part 86 & 1065/1066 in terms of features, performance, usage requirements, and calibration/verification requirements. Award will be made on a Best Value Basis. All non-price evaluation criteria, when combined, are significantly more important than price. Anticipated non-price evaluation criteria include demonstrated ability of the proposed system to meet or exceed the SOW requirements; past performance record under comparable contracts; and relevant previous experience. The solicitation should be issued on or about May 26, 2014 on FedConnect.net. This office does not intend to mail hard copies of the solicitation.

All responsible sources may submit a proposal which shall be considered by the Agency. Point of Contact for this requirement is Gerold Young, Contract Specialist, at (513) 487-2660, or by email at young.gerold@epa.gov. Questions must be submitted in writing to Gerold Young via email. Telephone queries will not be honored.

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Two (2) Laser Based N2O Analyzers for Chassis Testing Latest Award Notice
Two (2) Laser Based N2O Analyzers for Chassis Testing This notice · Original Award Notice

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity