Replace Perimeter Fencing
Closed Pre-Solicitation Posted
A newer solicitation was posted. See the latest solicitation from .
- Solicitation number
- W50S6M-20-B-0003
- Agency
- Alabama National Guard Army National Guard, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238990 All Other Specialty Trade Contractors
- Place of performance
- Birmingham, Alabama 35217, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This pre-solicitation notice seeks to replace perimeter fencing and construct access roads at the 117th Air Refueling Wing of the Alabama Army National Guard located in Birmingham, Alabama. The scope of work includes removing over 5,800 linear feet of existing fencing and installing new galvanized steel fencing and hardware per Unified Facilities Criteria standards. Additional requirements include clearing vegetation, installing vehicle cabling and bollards, constructing concrete foundations, and placing signage. Contractors must be able to perform materials testing and quality control. The deadline for questions is November 15, 2021.
The opportunity is set aside for total small businesses. The primary NAICS code is 238990 for all other specialty trade contractors, and the predominant PSC code covers fencing construction. The scope also includes over 2,000 square yards of earthwork, 1,050 linear feet and 875 linear feet of asphalt road construction, 180 linear feet of additional vehicle cabling and 16 bollards. Tree clearing will take place on property of the Birmingham Airport Authority, requiring contractors' employees to obtain security badges.
Notice text
2 versions
Update #2 · Latest ·
PRESOLICITATION NOTICE - THIS IS NOT A SOLICITATION
The purpose of this memorandum is to explain the Contracting Officer's logic supporting the inclusion of the following four option items in the solicitation W50S6M-22-B-0001, project number BRKR202005, Replace Base Perimeter Fence at the 117 Air Refueling Wing, Birmingham, AL.
1. Construct an asphalt access road for AT/FP measures. Provide all labor, tools, parts transportation, tools, equipment, materials, supplies, services, permits, insurance, supervision necessary to install asphalt access road as per Specifications and Drawings.
2. Install concrete driveway. Provide all labor, tools, parts transportation, tools, equipment, materials, supplies, services, permits, insurance, supervision necessary to install concrete driveway as per Specifications and Drawings.
3. Install erosion control measures and clear trees. Provide all labor, tools, parts transportation, tools, equipment, materials, supplies, services, permits, insurance, supervision necessary to install erosion control measures and clear trees
4. Install security bollards. Provide all labor, tools, parts transportation, tools, equipment, materials, supplies, services, permits, insurance, and supervision necessary to install security bollards.
This project will consist of replacing the boundary fence line according to UFC
4-022-03, and constructing access road for security concerns, located at the
117ARW, 5401 East Lake Blvd, Birmingham, AL 35217. Any plans provided
are original construction documents for information to the bidder and any
reference to new work should be ignored. Field verification of all work items,
site conditions, or any questions about the work to be performed are required
before submission of bids.
B. Replace 5,867 linear feet of chain link fence. Removal of fence includes posts,
fabric, and portions of the old fence posts that remain visible. Contractor will
haul the old fence and attachments off base, and dispose of. Use of concrete for
the fence project will be subject to compressive tests. Government will take
samples, and perform 7, 14, and 28 day tests. Compressive tests must be in
compliance with UFC standards. The section of fence that will be replaced is
indicated on Section 3-15.
C. Clearing and grubbing of 7,260 square yards of trees and vegetation.
Dimensions to clear the designated area include 30’ on the outside of fence,
and a 20’ on the inside of the fence. Clearing and grubbing include any
vegetation over 8” in height. This includes clearing small shrubs all the way to
large trees 24” in diameter.
D. Earthwork will be needed on the east fence line to make way for riprap. Remove
4” of top soil from future fence line to retaining wall to equivalent to 370 square
yards. Section 3-15 will indicate area. Geotextile will be placed on the remaining
subgrade, before riprap is laid. Riprap will be 9” in size.
E. Remove existing outriggers with the three strand barbed wire, and install new
“Y” outriggers with six strand of barbed wire for 545 LF. Indicated on map.
F. Installation of the new fence line will follow the same route as the existing fence
line unless directed otherwise.
G. Fencing fabric must be minimum 9-gauge wire mesh and mesh openings must
not be greater than 2-inches per side. Fence fabric material will be galvanized
steel. The fencing fabric must be extended to within 2 inches of firm ground
and anchored using horizontal bottom rails, tension wires, or concrete curbs
materials. Locate all posts, rails, bracing and tension wires on the
secure/protected side of the fencing fabric. See drawing 3.1
H. Fencing fabric must be mounted on steel posts that are set in concrete with
additional bracing at corners and gate openings, as necessary. Posts, bracing,
and all other structural members must be placed on the secure-side of the
fencing fabric.
I. Steel truss rods used for bracing must have a minimum nominal diameter of
5/16 inch and provided with turnbuckles for tensioning. Provide bracing for
each gate, terminal and end post. Install truss rods diagonally from near
ground level of the gate, terminal or end post to within 6 inches from the top of
the fabric at the adjacent line post. Fencing fabric can be securely fastened to
tension wires on the top and bottom with 9 gage galvanized tie wires
incorporating at least three full twists, 9 gage round wire galvanized hog rings,
or in a manner that provides a tensile strength equal to or greater than the
strength of the fencing fabric. Securing all fastening and hinge hardware by
welding to prevent disassembly of fencing and gate components.
J. All security and perimeter fencing must have a minimum fence fabric height of
7 feet excluding the top guard. Fence height including outriggers must be a
minimum of 8 feet.
K. When required, install outriggers at 45-degree angles in a "Y"/"V"
configuration, constructed of a double outrigger consisting of 18-inch arms,
each having three strands of barbed wire at regular intervals along the top of
the fence.
L. The outriggers must provide a minimum of an additional 12 inches to the
fence height. The top guard fencing adjoining gates with vertical height of 18
inches, but for a limited distance along the fence line to adequately open the
gates. Outriggers must be permanently affixed to the fence posts with screws
or by spot welding. Screws used to affix outriggers to posts must be made
tamper-proof either by design, peening, or welding.
M. Fences require 6 strands of barbed wire equally spaced. Barbed wire must
consist of two 12.5-gauge twisted line wires with 15-gauge round barbs.
Barbed wire must be zinc-coated steel. All barbs must consist of four points
and spacing of barbs must be at 5-inch centers.
N. Fences must be grounded at each side of a gate or other opening. In addition
to openings, grounding will be added at the start and last post of fence
section. Gates must be bonded to the grounding conductor, jumper, or fence.
A buried bonding jumper must be used to bond across a gate or other opening
in the fence, unless a nonconducting fence section is used. If barbed wire
strands are used above the fence fabric, the barbed wire strands must be
bonded to the grounding conductor, jumper, or fence. When fence posts are of
conducting material, the grounding conductor must be connected to the fence
post or posts, as required, with suitable connecting means. When fence posts
are of nonconducting material, suitable bonding connection must be made to
the fence mesh strands and the barbed wire strands at each grounding
conductor point. See section 3.1 for grounding detail.
O. Ditches and swales must provide additional fencing below, suspending from
the lower rail of the main fence to the auxiliary frame and around the sides of
the ditch. The added fence must be attached every 2 inches along the
intersection of the two fence sections and either attached to a series of ground
stakes secured to the sides and bottom of the ditch, or embedded in a
concrete sill in the ditch or swale. Concrete curbing must be used to fill areas
between fencing and ground surface. Several cases in this project will include
adding additional fabric to extend into the ditches. Most will only include a few
additional inches in depth. See section 3.3 and 3.4 drawing.
P. Provide a screen arrangement below fencing using vertical and/or horizontal
steel bars or pipes for ditches and swales receiving frequent water flow.
Provide a maximum spacing of 9 inches between either vertical or horizontal
bars. Possible debris must be considered when designing the spacing
between bars. Crossing bars must be welded at each intersection, with bars
embedded 6 inches into concrete and fastened to the bottom rail of the
crossing fence.
Q. Where cabling exist, replace post by post to ensure holding tension of the
cabling. Do not demo entire fence line with cabling, unless COR approves. As
new fabric and accessories are installed, ensure cabling is installed same
height as previously on old fence. Please refer to the DOD Anti-Ram Vehicle
Barrier listing to choose the correct cabling. Cabling must be securely bolted
back on. See section 3.5 and 3.6 for drawing.
R. Roughly 1575 LF of cabling will be added to fence line. Reinforcing cables
must be terminated to concrete deadman anchors. Anchors are to be placed
at intervals of 200 feet on the secure/protected side of the perimeter fencing.
Offset deadman anchors from fence at the minimum distance required to
avoid interference with post and to allow maintenance access to the
turnbuckles, clamps, and other accessories. Terminations for 200’ sections
should overlap the adjacent cabling section to ensure no lapse of coverage.
DOD Anti-Ram Vehicle Barrier listing will be provided to contractor. See
drawing 3.7 for cable terminations.
S. Eyebolts embedded in the concrete deadman anchors may have either a
welded "T" or "L" end. The eyebolt can either be in-line with the attached
cable or flush against the deadman surface. When used, eyebolts should be
welded and galvanized to the anchor rods. The top side of the deadman can
be placed flush with or below the ground surface with the eye of the eyebolt
above ground. Threaded rods may also be used as an alternative to the eye
bolt when securing the cables to the deadman anchor. When using threaded
rods, the threaded rod and wire rope connection must be visible above ground
like the eyebolt previously described.
T. With the case of cable terminations, bollards will be placed in the weaken
areas. This is to ensure protection is still provided. Eight bollards will be
placed at 4’ intervals or less. See section 3.5, 3.7, and 3.8 for bollard details.
CAD drawings will indicate location of needed bollards.
U. For concrete pipes that pass under fences, the grill ends must be welded to a
steel rim that fits snugly over the concrete pipe. The rim and grillwork will be
fastened over the concrete pipe and bolted or pinned to the rim of the
concrete pipe. Grill ends may be embedded in a concrete headwall that
encapsulates the concrete pipe. Grills must be placed on attack side of the
fence. Care must be taken during design to assure that bars and grills across
culverts are not susceptible to clogging. All utility openings are intended to be
designed with a debris catcher to permit either rapid clearing or removal of
grating for cleaning when required. Steel used for grill must be in accordance
with ASTM A529 and the corrosion prevention control section of the UFC. See
section 3.12 for drawing. Contractor may submit their plan for options other
than mentioned.
V. The double swing vehicular gate must be designed to swing inward, toward
secured area. A 2 inch maximum clearance must be maintained between the
bottom of fence and the road surface when gate is in closed position. Gate
openings for double swing gates 12 feet. Provide 3’ 6” deep concrete
foundation must be used for swing gate posts. Gate swings must be designed
with a large arc space for proper operation. Weld hinges to the gate post and
gate. Provide chain for swing gate, and ensure chain is reasonably tight but
easy to remove with the lock. Government will provide lock.
W. Reweave bottom fabric which includes 500 LF of existing fence fabric to
horizontal post, or wire. Use the same standards as new fence line using 9-
gauge tension wire.
X. Access road will begin south of detention pond, indicated on Section 3-15, and
tie into existing asphalt near church. 3” of ¾” stone to be compacted to 95%
for ASTM standards. Compact every 2” lifts. Two foot shoulders for each side
which will make a total of 16’ width. 2” of asphalt binder course, and 1.5” of
asphalt wearing surface for a width of 12’. The difference from wearing
surface, and aggregate shoulder should not exceed more than a 1” drop off in
height. Asphalt compaction of 94lbf, plus or minus 2lbf. Earthwork will be
needed to ensure asphalt is no more than 2” above existing surface. Asphalt
will be roughly 1,050LF. ALDOT sign R5-11, Authorized Vehicles Only, will be
placed at both ends of new street. On same pole, street name plate will be
added on both poles. Contractor will provide all four signs, posts, and concrete
to set posts. See drawings for more information. Base Civil Engineer will
determine street name at a later time.
Y. Access road will begin behind CE warehouse, and travel east to CE aggregate
pit. 4” of ¾” stone, and 2” of 8910 to be compacted to 95% for ASTM
standards. Compact every 2” lifts. 4” of asphalt binder course, and 2” wearing
surface with a 12’ width. The difference from wearing surface, and existing
surface should not exceed more than a 1” drop off in height. Asphalt
compaction of 94lbf, plus or minus 2lbf. Asphalt will be roughly 875LF.
Earthwork will be needed. ALDOT sign R5-11, Authorized Vehicles Only, will
be placed at beginning of new street. On same pole, street name plate will be
added. Contractor will provide both signs, post, and concrete to set post. See
drawings for more information. Base Civil Engineer will determine street name
at a later time.
Z. Base must stay secured at all times. Contractor must not demo the existing fence
unless plans are in place to install new fence in its place same day. Contractor
will not leave worksite for the day unless boundary fence is still connected.
AA. The tree clearing, and fence replacement of the eastern most fence line will be
conducted on Birmingham Airport Authority property. Any crews that will be a
part of this portion of the project must have a STA badge from the Airport. Each
badge will cost $65. This badge will include the contractor taking three airfield
courses. These courses are offered at the BAA badge office. Contractor must set
up time with BAA through project COR to take courses, and register their
employees.
1.3 ADDITIONAL BID ITEM
A. Install 180 linear feet of vehicle cabling to secure secondary gates near building
40. Install 16 bollards to help secure the new cabling. Cabling and bollards will
follow UFC 4-022-03 standards. See Section 3-5, and map for indicated area.
1.4 CONTRACT RESPONSIBILITIES
A. The work is one contract bid package that will be contracted directly with the
CONTRACTING OFFICER.
B. Responsibilities of CONTRACTOR:
1. Except as specifically noted, provide and pay for:
a) Labor, materials, and equipment.
b) Tools, construction equipment andmachinery.
c) Other facilities and services necessary for proper execution and
completion of work (locating and flagging underground utilities, etc.)
d) Independent testing lab to do all materials and quality control testing
if required.
e) “Provide” means to furnish and install, complete and ready for
operation.
2. Give required notices.
3. Comply with codes, ordinances, rules and regulations, orders and other
legal requirements of public authorities which bear on performance of
work.
4. Promptly submit written notice to CONTRACTING OFFICER of observed
variance of contract documents from legal requirements.
a) Assume responsibility for work to be contrary to such
requirements, without notice.
b) Appropriate modifications to Contract Documents will adjust
changes necessary due to legal requirements.
5. Enforce strict discipline and good order among employees. Do not
employ on work:
a) Unfit persons.
b) Persons not skilled on assigned tasks.
6. Furnish all submittals (including shop drawings, catalog cuts, brochures,
test reports, progress schedules, estimates and general correspondence)
promptly and on time to be approved before starting the work for which
submittals are required.
C. Responsibilities of CONTRACTINGOFFICER:
1. CONTRACTING OFFICER to review materials testing lab qualifications
submitted by the CONTRACTOR. This responsibility is generally
delegated to the Base Civil Engineer Office.
2. Construction Drawings.
1.5 CONTRACTOR USE OF PREMISES
A. Confine operations at site to areas permitted by:
1. Law
2. Ordinances
3. Permits
4. Contract Documents
5. Existing Staging Areas
6. Where directed by CONTRACTING OFFICER.
B. Do not unreasonable encumber site with materials or equipment.
C. Assume full responsibility for protection and safekeeping of products stored on
premises.
D. Move any stored products which interfere with operations of CONTRACTING
OFFICER or other CONTRACTORS engaged in work for the CONTRACTING
OFFICER.
E. Use of Site: Government will occupy the site during construction. Coordinate so
that the least amount of disruption is caused, that traffic and personnel safety is
maintain.
F. CLEANLINESS IS THE ESSENCE OF QUALITY. Keep site clean. Remove
waste material from the site weekly. Failure to comply will result in notice to
clean site given by CONTRACTING OFFICER; if not cleaned within twelve (12)
hours from time of notice, the CONTRACTING OFFICER will clean the site and
charge the CONTRACTOR $200.00/hour for this work.
1.6 SUBMITTALS
A. Approval for all materials must be given before installation.
B. No work can be started until such work has been discussed and reviewed by the
CONTRACTING OFFICER
C. Test reports shall be checked by the Base Civil Engineer and the
CONTRACTING OFFICER to insure compliance with the Specifications.
D. Any deviations will be made known to the CONTRACTOR and
CONTRACTING OFFICER.
E. It is the CONTRACTOR’S responsibility to achieve compliance with the
Specifications.
PART 2 PRODUCT SUBMITTAL
2.1 Fence fabric (wire gauge)
2.2 Fence post
2.3 Extension arm
2.4 Barbed wire
2.5 Fence bracing rod and turnbuckles
2.6 Fasteners/Weld
2.7 Concrete
2.8 Rebar
2.9 Bollard
2.10 Steel culvert grate/other option
2.11 Vehicle Cable
2.12 Riprap
2.13 Geotextile fabric
2.14 Tree Trimming equipment (Approval from FAA)
Update #1 ·
PRESOLICITATION NOTICE - THIS IS NOT A SOLICITATION
This project will consist of replacing the boundary fence line according to UFC
4-022-03, and constructing access road for security concerns, located at the
117ARW, 5401 East Lake Blvd, Birmingham, AL 35217. Any plans provided
are original construction documents for information to the bidder and any
reference to new work should be ignored. Field verification of all work items,
site conditions, or any questions about the work to be performed are required
before submission of bids.
B. Replace 5,867 linear feet of chain link fence. Removal of fence includes posts,
fabric, and portions of the old fence posts that remain visible. Contractor will
haul the old fence and attachments off base, and dispose of. Use of concrete for
the fence project will be subject to compressive tests. Government will take
samples, and perform 7, 14, and 28 day tests. Compressive tests must be in
compliance with UFC standards. The section of fence that will be replaced is
indicated on Section 3-15.
C. Clearing and grubbing of 7,260 square yards of trees and vegetation.
Dimensions to clear the designated area include 30’ on the outside of fence,
and a 20’ on the inside of the fence. Clearing and grubbing include any
vegetation over 8” in height. This includes clearing small shrubs all the way to
large trees 24” in diameter.
D. Earthwork will be needed on the east fence line to make way for riprap. Remove
4” of top soil from future fence line to retaining wall to equivalent to 370 square
yards. Section 3-15 will indicate area. Geotextile will be placed on the remaining
subgrade, before riprap is laid. Riprap will be 9” in size.
E. Remove existing outriggers with the three strand barbed wire, and install new
“Y” outriggers with six strand of barbed wire for 545 LF. Indicated on map.
F. Installation of the new fence line will follow the same route as the existing fence
line unless directed otherwise.
G. Fencing fabric must be minimum 9-gauge wire mesh and mesh openings must
not be greater than 2-inches per side. Fence fabric material will be galvanized
steel. The fencing fabric must be extended to within 2 inches of firm ground
and anchored using horizontal bottom rails, tension wires, or concrete curbs
materials. Locate all posts, rails, bracing and tension wires on the
secure/protected side of the fencing fabric. See drawing 3.1
H. Fencing fabric must be mounted on steel posts that are set in concrete with
additional bracing at corners and gate openings, as necessary. Posts, bracing,
and all other structural members must be placed on the secure-side of the
fencing fabric.
I. Steel truss rods used for bracing must have a minimum nominal diameter of
5/16 inch and provided with turnbuckles for tensioning. Provide bracing for
each gate, terminal and end post. Install truss rods diagonally from near
ground level of the gate, terminal or end post to within 6 inches from the top of
the fabric at the adjacent line post. Fencing fabric can be securely fastened to
tension wires on the top and bottom with 9 gage galvanized tie wires
incorporating at least three full twists, 9 gage round wire galvanized hog rings,
or in a manner that provides a tensile strength equal to or greater than the
strength of the fencing fabric. Securing all fastening and hinge hardware by
welding to prevent disassembly of fencing and gate components.
J. All security and perimeter fencing must have a minimum fence fabric height of
7 feet excluding the top guard. Fence height including outriggers must be a
minimum of 8 feet.
K. When required, install outriggers at 45-degree angles in a "Y"/"V"
configuration, constructed of a double outrigger consisting of 18-inch arms,
each having three strands of barbed wire at regular intervals along the top of
the fence.
L. The outriggers must provide a minimum of an additional 12 inches to the
fence height. The top guard fencing adjoining gates with vertical height of 18
inches, but for a limited distance along the fence line to adequately open the
gates. Outriggers must be permanently affixed to the fence posts with screws
or by spot welding. Screws used to affix outriggers to posts must be made
tamper-proof either by design, peening, or welding.
M. Fences require 6 strands of barbed wire equally spaced. Barbed wire must
consist of two 12.5-gauge twisted line wires with 15-gauge round barbs.
Barbed wire must be zinc-coated steel. All barbs must consist of four points
and spacing of barbs must be at 5-inch centers.
N. Fences must be grounded at each side of a gate or other opening. In addition
to openings, grounding will be added at the start and last post of fence
section. Gates must be bonded to the grounding conductor, jumper, or fence.
A buried bonding jumper must be used to bond across a gate or other opening
in the fence, unless a nonconducting fence section is used. If barbed wire
strands are used above the fence fabric, the barbed wire strands must be
bonded to the grounding conductor, jumper, or fence. When fence posts are of
conducting material, the grounding conductor must be connected to the fence
post or posts, as required, with suitable connecting means. When fence posts
are of nonconducting material, suitable bonding connection must be made to
the fence mesh strands and the barbed wire strands at each grounding
conductor point. See section 3.1 for grounding detail.
O. Ditches and swales must provide additional fencing below, suspending from
the lower rail of the main fence to the auxiliary frame and around the sides of
the ditch. The added fence must be attached every 2 inches along the
intersection of the two fence sections and either attached to a series of ground
stakes secured to the sides and bottom of the ditch, or embedded in a
concrete sill in the ditch or swale. Concrete curbing must be used to fill areas
between fencing and ground surface. Several cases in this project will include
adding additional fabric to extend into the ditches. Most will only include a few
additional inches in depth. See section 3.3 and 3.4 drawing.
P. Provide a screen arrangement below fencing using vertical and/or horizontal
steel bars or pipes for ditches and swales receiving frequent water flow.
Provide a maximum spacing of 9 inches between either vertical or horizontal
bars. Possible debris must be considered when designing the spacing
between bars. Crossing bars must be welded at each intersection, with bars
embedded 6 inches into concrete and fastened to the bottom rail of the
crossing fence.
Q. Where cabling exist, replace post by post to ensure holding tension of the
cabling. Do not demo entire fence line with cabling, unless COR approves. As
new fabric and accessories are installed, ensure cabling is installed same
height as previously on old fence. Please refer to the DOD Anti-Ram Vehicle
Barrier listing to choose the correct cabling. Cabling must be securely bolted
back on. See section 3.5 and 3.6 for drawing.
R. Roughly 1575 LF of cabling will be added to fence line. Reinforcing cables
must be terminated to concrete deadman anchors. Anchors are to be placed
at intervals of 200 feet on the secure/protected side of the perimeter fencing.
Offset deadman anchors from fence at the minimum distance required to
avoid interference with post and to allow maintenance access to the
turnbuckles, clamps, and other accessories. Terminations for 200’ sections
should overlap the adjacent cabling section to ensure no lapse of coverage.
DOD Anti-Ram Vehicle Barrier listing will be provided to contractor. See
drawing 3.7 for cable terminations.
S. Eyebolts embedded in the concrete deadman anchors may have either a
welded "T" or "L" end. The eyebolt can either be in-line with the attached
cable or flush against the deadman surface. When used, eyebolts should be
welded and galvanized to the anchor rods. The top side of the deadman can
be placed flush with or below the ground surface with the eye of the eyebolt
above ground. Threaded rods may also be used as an alternative to the eye
bolt when securing the cables to the deadman anchor. When using threaded
rods, the threaded rod and wire rope connection must be visible above ground
like the eyebolt previously described.
T. With the case of cable terminations, bollards will be placed in the weaken
areas. This is to ensure protection is still provided. Eight bollards will be
placed at 4’ intervals or less. See section 3.5, 3.7, and 3.8 for bollard details.
CAD drawings will indicate location of needed bollards.
U. For concrete pipes that pass under fences, the grill ends must be welded to a
steel rim that fits snugly over the concrete pipe. The rim and grillwork will be
fastened over the concrete pipe and bolted or pinned to the rim of the
concrete pipe. Grill ends may be embedded in a concrete headwall that
encapsulates the concrete pipe. Grills must be placed on attack side of the
fence. Care must be taken during design to assure that bars and grills across
culverts are not susceptible to clogging. All utility openings are intended to be
designed with a debris catcher to permit either rapid clearing or removal of
grating for cleaning when required. Steel used for grill must be in accordance
with ASTM A529 and the corrosion prevention control section of the UFC. See
section 3.12 for drawing. Contractor may submit their plan for options other
than mentioned.
V. The double swing vehicular gate must be designed to swing inward, toward
secured area. A 2 inch maximum clearance must be maintained between the
bottom of fence and the road surface when gate is in closed position. Gate
openings for double swing gates 12 feet. Provide 3’ 6” deep concrete
foundation must be used for swing gate posts. Gate swings must be designed
with a large arc space for proper operation. Weld hinges to the gate post and
gate. Provide chain for swing gate, and ensure chain is reasonably tight but
easy to remove with the lock. Government will provide lock.
W. Reweave bottom fabric which includes 500 LF of existing fence fabric to
horizontal post, or wire. Use the same standards as new fence line using 9-
gauge tension wire.
X. Access road will begin south of detention pond, indicated on Section 3-15, and
tie into existing asphalt near church. 3” of ¾” stone to be compacted to 95%
for ASTM standards. Compact every 2” lifts. Two foot shoulders for each side
which will make a total of 16’ width. 2” of asphalt binder course, and 1.5” of
asphalt wearing surface for a width of 12’. The difference from wearing
surface, and aggregate shoulder should not exceed more than a 1” drop off in
height. Asphalt compaction of 94lbf, plus or minus 2lbf. Earthwork will be
needed to ensure asphalt is no more than 2” above existing surface. Asphalt
will be roughly 1,050LF. ALDOT sign R5-11, Authorized Vehicles Only, will be
placed at both ends of new street. On same pole, street name plate will be
added on both poles. Contractor will provide all four signs, posts, and concrete
to set posts. See drawings for more information. Base Civil Engineer will
determine street name at a later time.
Y. Access road will begin behind CE warehouse, and travel east to CE aggregate
pit. 4” of ¾” stone, and 2” of 8910 to be compacted to 95% for ASTM
standards. Compact every 2” lifts. 4” of asphalt binder course, and 2” wearing
surface with a 12’ width. The difference from wearing surface, and existing
surface should not exceed more than a 1” drop off in height. Asphalt
compaction of 94lbf, plus or minus 2lbf. Asphalt will be roughly 875LF.
Earthwork will be needed. ALDOT sign R5-11, Authorized Vehicles Only, will
be placed at beginning of new street. On same pole, street name plate will be
added. Contractor will provide both signs, post, and concrete to set post. See
drawings for more information. Base Civil Engineer will determine street name
at a later time.
Z. Base must stay secured at all times. Contractor must not demo the existing fence
unless plans are in place to install new fence in its place same day. Contractor
will not leave worksite for the day unless boundary fence is still connected.
AA. The tree clearing, and fence replacement of the eastern most fence line will be
conducted on Birmingham Airport Authority property. Any crews that will be a
part of this portion of the project must have a STA badge from the Airport. Each
badge will cost $65. This badge will include the contractor taking three airfield
courses. These courses are offered at the BAA badge office. Contractor must set
up time with BAA through project COR to take courses, and register their
employees.
1.3 ADDITIONAL BID ITEM
A. Install 180 linear feet of vehicle cabling to secure secondary gates near building
40. Install 16 bollards to help secure the new cabling. Cabling and bollards will
follow UFC 4-022-03 standards. See Section 3-5, and map for indicated area.
1.4 CONTRACT RESPONSIBILITIES
A. The work is one contract bid package that will be contracted directly with the
CONTRACTING OFFICER.
B. Responsibilities of CONTRACTOR:
1. Except as specifically noted, provide and pay for:
a) Labor, materials, and equipment.
b) Tools, construction equipment andmachinery.
c) Other facilities and services necessary for proper execution and
completion of work (locating and flagging underground utilities, etc.)
d) Independent testing lab to do all materials and quality control testing
if required.
e) “Provide” means to furnish and install, complete and ready for
operation.
2. Give required notices.
3. Comply with codes, ordinances, rules and regulations, orders and other
legal requirements of public authorities which bear on performance of
work.
4. Promptly submit written notice to CONTRACTING OFFICER of observed
variance of contract documents from legal requirements.
a) Assume responsibility for work to be contrary to such
requirements, without notice.
b) Appropriate modifications to Contract Documents will adjust
changes necessary due to legal requirements.
5. Enforce strict discipline and good order among employees. Do not
employ on work:
a) Unfit persons.
b) Persons not skilled on assigned tasks.
6. Furnish all submittals (including shop drawings, catalog cuts, brochures,
test reports, progress schedules, estimates and general correspondence)
promptly and on time to be approved before starting the work for which
submittals are required.
C. Responsibilities of CONTRACTINGOFFICER:
1. CONTRACTING OFFICER to review materials testing lab qualifications
submitted by the CONTRACTOR. This responsibility is generally
delegated to the Base Civil Engineer Office.
2. Construction Drawings.
1.5 CONTRACTOR USE OF PREMISES
A. Confine operations at site to areas permitted by:
1. Law
2. Ordinances
3. Permits
4. Contract Documents
5. Existing Staging Areas
6. Where directed by CONTRACTING OFFICER.
B. Do not unreasonable encumber site with materials or equipment.
C. Assume full responsibility for protection and safekeeping of products stored on
premises.
D. Move any stored products which interfere with operations of CONTRACTING
OFFICER or other CONTRACTORS engaged in work for the CONTRACTING
OFFICER.
E. Use of Site: Government will occupy the site during construction. Coordinate so
that the least amount of disruption is caused, that traffic and personnel safety is
maintain.
F. CLEANLINESS IS THE ESSENCE OF QUALITY. Keep site clean. Remove
waste material from the site weekly. Failure to comply will result in notice to
clean site given by CONTRACTING OFFICER; if not cleaned within twelve (12)
hours from time of notice, the CONTRACTING OFFICER will clean the site and
charge the CONTRACTOR $200.00/hour for this work.
1.6 SUBMITTALS
A. Approval for all materials must be given before installation.
B. No work can be started until such work has been discussed and reviewed by the
CONTRACTING OFFICER
C. Test reports shall be checked by the Base Civil Engineer and the
CONTRACTING OFFICER to insure compliance with the Specifications.
D. Any deviations will be made known to the CONTRACTOR and
CONTRACTING OFFICER.
E. It is the CONTRACTOR’S responsibility to achieve compliance with the
Specifications.
PART 2 PRODUCT SUBMITTAL
2.1 Fence fabric (wire gauge)
2.2 Fence post
2.3 Extension arm
2.4 Barbed wire
2.5 Fence bracing rod and turnbuckles
2.6 Fasteners/Weld
2.7 Concrete
2.8 Rebar
2.9 Bollard
2.10 Steel culvert grate/other option
2.11 Vehicle Cable
2.12 Riprap
2.13 Geotextile fabric
2.14 Tree Trimming equipment (Approval from FAA)
Notice history
| Notice | Type | Posted |
|---|---|---|
| Replace Perimeter Fencing | Solicitation | |
| Replace Perimeter Fencing | Pre-Solicitation | |
| Replace Perimeter Fencing | Pre-Solicitation | |
| Replace Perimeter Fencing | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity