Replace Fire Alarm Ph. II
Awarded Award Notice Posted
- Solicitation number
- VA24217B0426
- Agency
- Veterans Integrated Service Network 2 Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to A Vet Communications, Inc.
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- Contract number
- VA24217C0140 Federal contract award
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Not on record
- Place of performance
- New York Harbor Healthcare System Manhattan Campus 423 E 23rd St New York, NY 10010 USA
Notice details come from SAM.gov. Updated .
Notice text
Added: Mar 21, 2017 2:00 pm
This notice is for Solicitation Number VA242-17-B-0426 - Project Number 630-13-125 Replace Fire Alarm Ph. II at the New York Harbor Healthcare System, Manhattan Campus, 423 E. 23rd St., New York, NY 10010.
This shall be a Service Disabled Veteran Owned Small Business Set-Aside (SDVOSB). As a result, all SDVOSB's may submit a bid, which will be considered by the agency. This project is classified under NAICS Code 236220 Commercial and Institutional Building Construction, and has a Size Standard of $36.5 million.
The cost estimate range for this project is $1,000,000.00 to $2,000,000.00.
Background:
The VAMC Manhattan Campus currently has a Notifier fire alarm system installed which was completed in 2014. Due to flooding and damage incurred from Hurricane Sandy, the fire alarm system needs to be brought up to code.
The phase II project will address some of those compromised items damaged and bring the system up to code and VA standards. This project will build upon the existing system and in order for optimal compatibility, uniformity and performance, the same Notifier product should be provided. This will also streamline service and maintenance down the line.
Scope of Work:
Furnish and provide all work, products, materials, installation, programming, and execution associated with removal of selected existing fire alarm devices and installation of selected new fire alarm devices in the main hospital building (Building 1), as well as Building 6 (OPC) and identified outbuildings at the Veteran s Affairs Medical Center, 423 East 23rd Street, New York, NY 10010.
The scope includes, but is not limited to installation and programming of new smoke detectors, heat detectors, strobes, automatic door closers, the installation of conduits for existing exposed fire alarm wiring, painting of all cross corridor smoke barrier door frames to match existing fire alarm control panel enclosure in Building 1 Elevator Lobby and update as-built drawings to incorporate all major projects completed during or prior to this work.
Contractor shall update existing Onyx work stations located in Building 1 room G273N and Building 2 room 108-A to reflect all changes to the fire alarm system. Contractor shall cross reference all system input/outputs between the fire alarm control panel and the Onyx workstations.
Contractor shall test the entire fire alarm system to include Buildings 1,2,3,5,6 in accordance with NFPA 72 to ensure complete functionality of all initiating and indicating devices, along with all associated equipment for a full and complete functioning system. The work includes all associated aspects, including but not limited to primary power supply, cutting and patching, and repair of finishes.
D. Fire alarm systems shall comply with requirements of the most recent VA FIRE PROTECTION DESIGN MANUAL and NFPA 72 unless variations to NFPA 72 are specifically identified within these contract documents by the following notation: "variation". The design, system layout, document submittal preparation, and supervision of installation and testing shall be provided by a technician that is certified NICET level III or a registered fire protection engineer. The NICET certified technician shall be on site for the supervision and testing of the system. Factory engineers from the equipment manufacturer, thoroughly familiar and knowledgeable with all equipment utilized, shall provide additional technical support at the site as required by the COR or his authorized representative. Installers shall have a minimum of 2 years experience installing fire alarm systems.
Project Completion: Period of Performance is 400 Calendar Days from Notice to Proceed.
All other details and information shall be contained in the solicitation which shall be posted on www.fbo.gov. The solicitation will be released on or about April 10, 2017. The response submittal address, date and time will be included in the solicitation. This project requires bonding and all responses/submissions shall be in hardcopies; faxed or e-mailed bids will not be accepted. All prospective bidders must be currently registered in www.sam.gov , www.experian.com, and be registered and verified as a SDVOSB in www.vip.vetbiz.gov at the time of offer submission and before award of this procurement.
Point of Contact is Sharon Pierce at Sharon.Pierce@va.gov.
End of Description.
Attachments
| File | Type | Posted |
|---|---|---|
| VA242-17-B-0426-A00001001.pdf | ||
| VA242-17-B-0426-A00001000.docx | DOCX document | |
| VA242-17-B-0426-002.pdf | ||
| VA242-17-B-0426-003.pdf | ||
| VA242-17-B-0426-001.docx | DOCX document | |
| VA242-17-B-0426-000.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Replace Fire Alarm Ph. II | Award Notice | |
| Replace Fire Alarm Ph. II | Award Notice |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity