Recovery - automatic bus transfer (ABT) switch replacement
Awarded Award Notice Posted
- Solicitation number
- HSCG40-10-Q-50044
- Agency
- Coast Guard Department of Homeland Security
- Awarded
- to Ward's Marine Electric, Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- HSCG4010C50022 Federal contract award
- NAICS code
- 336611 Ship Building and Repairing
- PSC
- Not on record
- Place of performance
- To be addressed in the solicitation package., United States
Notice details come from SAM.gov. Updated .
Notice text
Added: Jan 25, 2010 12:01 pm
This project is being conducted in accordance with the American Reinvestment and Recovery Act project (ARRA) requirements. Any resulting solicitation and contract is subject to applicable ARRA provisions and clauses, including the Recovery Act reporting requirements as specified in FAR 52.204-11. The U.S. Coast Guard SFLC intends to issue a solicitation and award a contract for purchase of and removal and installation of Automatic Bus Transfer (ABT) Switches onboard eight (8) 378 WHEC Coast Guard Cutters. The solicitation will be issued on a brand name or equal basis using the brand name ASCO. The following is a list of salients that will be purchased: (1) 100 Amp, Automatic Bus Transfer Switch ASCO A94231009A3D, QTY 128 EA; Mil-Spec. requirement- Transfer Switch must meet requirements of Military Specification MIL-SPF-17773 -- Shock requirements- Each transfer switch must meet requirements of MIL-S-901 for Grade A, Class1, Type A equipment - Vibration requirement- Each Transfer switch must meet requirements of MIL-STD-167-1 - Type- Each transfer switch shall be of the magnetic switching type- Control Panel- Each transfer switch shall be constructed with Interchangeable Solid State Controls. - Operator- Each transfer switch shall be constructed with Single-solenoid operator to drive contacts from one source to another. Must also have manual built-in operating handle for use if needed. - Amperage Each Transfer switch must be rated for 100 Amps. - Voltage Each transfer switch must be rated for 450 volts immediately adjacent to the purifier itself in the same dimensional envelope - Frequency Each Transfer switch must be rate for 60 Hertz - Application- Each Transfer switch shall meet application 3 with in-phase monitoring with drop-out se t for 80-85% of nominal voltage and pick-up set for 85-95% of nominal voltage with single phase sensing on Normal. - Enclosure Each Transfer switch must be contained in a dripproof enclosure. - Dimensions Each Transfer switch must meet the dimensions of 21H x 12 W x 13 D, 60-80 lbs. - Electrical - The electrical installations and equipment shall meet 46CFR Subchapter J, IEEE STD 45 and NEMA standards as applicable, and shall be compatible with the cutter standard 440VAC, 3 phase, 60 hertz ungrounded system. - Wiring Shall be in accordance with IEEE STD 45 and NEMA standard ICS. - Construction- Unit shall be of modular construction to facilitate the ease of maintenance. -- (2) 150 Amp, Automatic Bus Transfer switch ACSO A94231509A3D, QTY 8 EA; Transfer switch -- Mil-Spec. Requirement- Transfer Switch must meet requirements of Military Specification MIL-SPF-17773 -- Shock requirements- Each transfer switch must meet requirements of MIL-S-901 for Grade A, Class1, Type A equipment - - Vibration requirement- Each Transfer switch must meet requirements of MIL-STD-167-1 -- Type- Each transfer switch shall be of the magnetic switching type -- Control Panel- Each transfer switch shall be constructed with Interchangeable Solid State Controls. -- Amperage Each Transfer switch must be rated for 150 Amps.-- Voltage Each transfer switch must be rated for 450 volts immediately adjacent to the purifier itself in the same dimensional envelope -- Frequency Each Transfer switch must be rate for 60 Hertz -- Application- Each Transfer switch shall meet application 3 with in-phase monitoring with drop-out se t for 80-85% of nominal voltage and pick-up set for 85-95% of nominal voltage with single phase sensing on Normal. -- Enclosure Each Transfer switch must be contained in a dripproof enclosure. - Dimensions Each Transfer switch must meet the dimensions of 25H x 18 W x 13 D, 100-110 lbs. -- Electrical - The electrical installations and equipment shall meet 46CFR Subchapter J, IEEE STD 45 and NEMA standards as applicable, and shall be compatible with the cutter standard 440VAC, 3 phase, 60 hertz ungrounded system. - Wiring Shall be in accordance with IEEE STD 45 and NEMA standard ICS. - Construction- Unit shall be of modular construction to facilitate the ease of maintenance. -- 3) 300 Amp, Automatic Bus Transfer switch A94233009A3D, QTY 8 EA, Mil-Spec. Requirement- Transfer Switch must meet requirements of Military Specification MIL-SPF-17773 -- Shock requirements- Each transfer switch must meet requirements of MIL-S-901 for Grade A, Class1, Type A equipment - Vibration requirement- Each Transfer switch must meet requirements of MIL-STD-167-1 -Type- Each transfer switch shall be of the magnetic switching type - Control Panel- Each transfer switch shall be constructed with Interchangeable Solid State Controls. - Amperage Each Transfer switch must be rated for 300 Amps. - Voltage Each transfer switch must be rated for 450 volts immediately adjacent to the purifier itself in the same dimensional envelope - Frequency Each Transfer switch must be rate for 60 Hertz - Application- Each Transfer switch shall meet application 3 with in-phase monitoring with drop-out se t for 80-85% of nominal voltage and pick-up set for 85-95% of nominal voltage with single phase sensing on Normal. - Enclosure Each Transfer switch must be contained in a dripproof enclosure. - Dimensions Each Transfer switch must meet the dimensions of 25H x 18 W x 13 D, 100-110 lbs. - Electrical - The electrical installations and equipment shall meet 46CFR Subchapter J, IEEE STD 45 and NEMA standards as applicable, and shall be compatible with the cutter standard 440VAC, 3 phase, 60 hertz ungrounded system. - Wiring Shall be in accordance with IEEE STD 45 and NEMA standard ICS. - Construction- Unit shall be of modular construction to facilitate the ease of maintenance.
The contractor will be responsible for providing all labor, material, tools and manpower to remove the ABT switches and replace 1 shipset onboard each 378 WHECs Coast Guard Cutter. A shipset consists of the following: (1) ACSO 100 AMPS = 16 EA, (2) ASCO 150 AMP = 1 EA, (3) ACSO 300 AMPS 1 EA -- The solicitation will address the timeframe and geographic locations of the Coast Guard Cutters. The solicitation will be posted on FedBizOpps on or about 02/05/10. It is the contractors responsibility to check FedBizopps on a regular basis for the solicitation and any amendments issued. Contractors shall be registered in the Central Contractors Registration (CCR). To register in CCR go to www.bpn.gov.
Attachments
| File | Type | Posted |
|---|---|---|
| SF30Amdmt1.doc | DOC document | |
| ABT Solicitation.doc | DOC document |