Pre-Exit Telemetry Re-Transmission Amplifier (PETRA) GEN 2
Awarded Award Notice Posted
- Solicitation number
- N64267-17-T-0160
- Agency
- Naval Sea Systems Command Department of the Navy, Department of Defense
- Awarded
- to Systems Engineering & Management Company
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- N6426717P0160 Federal contract award
- NAICS code
- 334220 Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
- PSC
- Not on record
Notice details come from SAM.gov. Updated .
Notice text
Added: Jun 06, 2017 11:33 am
This sources sought notice is being posted to satisfy the requirement under the Defense Federal Acquisition Regulation Supplement PGI 206.302-1(d).
The Naval Surface warfare Center (NSWC), Corona Division intends to award on a sole source basis to Systems Engineering & Management Company 1430 Vantage Court Vista, Ca 92081 for the following:
(6 ea) Pre-Exit Telemetry Re-Transmission Amplifier due to proprietary rights and data.
This notice is published for informational purposes only and not a request for competitive proposals. However, all responsible sources may submit their technical capabilities, which if received by 26 May 2017, shall be considered by NSWC Corona.
Responses must be submitted in writing to the procurement specialist, Luke Salazar, via email at luke.salazar@navy.mil no later than 12:00 pm PST on the date noted above. Email should reference Sources Sought Notice N64267-17-T-0160 in the subject.
A determination by the Government not to compete this requirement based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement.
ELECTRICAL |
|
Type | Pre-Exit Telemetry Retransmission and Amplification System |
Frequency Band | S Band (2200 MHz - 2395 MHz) |
Input Voltage | 90 to 265 VAC (115/230 VAC auto ranging) |
Input Frequency | 50 to 60 Hz |
Input/Output RF Impedance | 50 ohms, 2:1 max VSWR |
|
|
PERFORMANCE |
|
RF Input level to activate Transmission | No greater than -39 dBm |
Maximum Usable Linear Level | 0 dBm |
Maximum input level without damage | +10 dBm |
RF Input level to deactivate Transmission after it has already been activated (Hysteresis) | No less than -43 dBm |
RF Output Level |
|
High Gain Mode | 40 dBm |
Low Gain Mode | 23 dBm |
RF Monitor Output | 7 + 1 dB below RF input level (unamplified output) |
Two Tone, Third Order Inter-Modulation Distortion Product |
|
High Gain Mode | No greater than 13dBm |
Low Gain Mode | No greater than -27dBm |
Maximum Noise Level in a 1MHz Bandwidth | -60 dBm |
Noise Suppression Circuit (Threshold enable/disable switch) | Required to disable the output amplifier to prevent noise from being radiated when no signals above threshold are being transmitted |
Leveling Circuit | Required to drive the output amplifier at a constant level and take care not to over drive or under drive the output at max power |
Self-Test | Should include some kind of built in self-test capability to assure user of functionality |
|
|
ANTENNA |
|
Type | Colinear Array Omnidirectional Narrow Beam |
Gain | 8 dBi |
Polarization Type | Vertical |
Beamwidth |
|
Azimuth | OMNI (360 degrees) |
Elevation | 15 degrees |
Connection | 50 ohm N-type RF out |
Equipment | 50 ft. low loss RF cable, and sturdy stainless steel pole mounts |
|
|
PHYSICAL |
|
Location | All switches/connections/LED are required to be on one side similar to the current design. There should be consideration to the configuration of the PETRA installation. The current design allows for a "standing" installation or installation lying down on its side. We would like to retain these options. |
|
|
Switches | Power On/Off switch, and High Gain/Low Gain switch, each with a cover to protect from accidental switching |
Connections |
|
Inputs |
|
AC Power | MILSPEC locking connector, which includes weather-sealed 6ft power cable |
RF | Two 50 ohm N-type connectors labeled FWD and AFT |
Outputs |
|
RF Antenna | 50 ohm N-type connecter labeled ANT |
RF Monitor | Two 50 ohm N-type connector labeled MON |
Indications |
|
Visual | Two LED Indicators, POWER ON and TRANSMITTING |
Audio | A loud audible tone to indicate system is transmitting |
Dimensions | One side no greater than 8", two sides no greater than 12", Maximum volume of 1152 cubic inches |
Weight | No greater than 30 lbs. |
|
|
ENVIRONMENTAL |
|
Operating Temperature | 50 to 140 degrees F |
Relative Humidity | 15 to 95% |
Storage Temperature | -4 to 158 degrees F |
Material | Ruggedized and resistant to heavy shock and vibration, water and EMI |
|
|
Notice history
| Notice | Type | Posted |
|---|---|---|
| Pre-Exit Telemetry Retransmission and Amplifications System (PETRA) | Award Notice | |
| Pre-Exit Telemetry Retransmission and Amplifications System (PETRA) | Award Notice | |
| Pre-Exit Telemetry Retransmission Amplification System (PETRA) | Award Notice | |
| Pre-Exit Telemetry Re-Transmission Amplifier (PETRA) GEN 2 | Award Notice |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity