Pre-Exit Telemetry Re-Transmission Amplifier (PETRA) GEN 2

Awarded Award Notice Posted

Solicitation number
N64267-17-T-0160
Agency
Naval Sea Systems Command Department of the Navy, Department of Defense
Awarded
to Systems Engineering & Management Company
Set-aside
No set-aside

Opportunity facts

Contract number
N6426717P0160 Federal contract award
NAICS code
334220 Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
PSC
Not on record

Notice details come from SAM.gov. Updated .

Notice text

Added: Jun 06, 2017 11:33 am

This sources sought notice is being posted to satisfy the requirement under the Defense Federal Acquisition Regulation Supplement PGI 206.302-1(d).


 The Naval Surface warfare Center (NSWC), Corona Division intends to award on a sole source basis to Systems Engineering & Management Company 1430 Vantage Court Vista, Ca 92081 for the following:


 (6 ea) Pre-Exit Telemetry Re-Transmission Amplifier due to proprietary rights and data.


 This notice is published for informational purposes only and not a request for competitive proposals.  However, all responsible sources may submit their technical capabilities, which if received by 26 May 2017, shall be considered by NSWC Corona.


 Responses must be submitted in writing to the procurement specialist, Luke Salazar, via email at luke.salazar@navy.mil no later than 12:00 pm PST on the date noted above.  Email should reference Sources Sought Notice N64267-17-T-0160 in the subject.


 A determination by the Government not to compete this requirement based on responses to this notice is solely within the discretion of the Government.  Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement.

 


ELECTRICAL



 



Type



Pre-Exit Telemetry Retransmission and Amplification System



Frequency Band



S Band (2200 MHz - 2395 MHz)



Input Voltage



90 to 265 VAC (115/230 VAC auto ranging)



Input Frequency



50 to 60 Hz



Input/Output RF Impedance



50 ohms, 2:1 max VSWR



 



 



PERFORMANCE



 



RF Input level to activate Transmission



No greater than -39 dBm



Maximum Usable Linear Level



0 dBm



Maximum input level without damage



+10 dBm



RF Input level to deactivate Transmission after it has already been activated (Hysteresis)



No less than -43 dBm



RF Output Level



 



               High Gain Mode



40 dBm



               Low Gain Mode



23 dBm



RF Monitor Output



7 + 1 dB below RF input level (unamplified output)



Two Tone, Third Order Inter-Modulation Distortion Product



 



               High Gain Mode



No greater than 13dBm



               Low Gain Mode          



No greater than -27dBm



Maximum Noise Level in a 1MHz Bandwidth



-60 dBm



Noise Suppression Circuit


(Threshold enable/disable switch)



Required to disable the output amplifier to prevent noise from being radiated when no signals above threshold are being transmitted



Leveling Circuit



Required to drive the output amplifier at a constant level and take care not to over drive or under drive the output at max power



Self-Test



Should include some kind of built in self-test capability to assure user of functionality



 



 



ANTENNA



 



   Type



Colinear Array Omnidirectional Narrow Beam



   Gain



8 dBi



   Polarization Type



Vertical



   Beamwidth



 



      Azimuth



OMNI (360 degrees)



      Elevation



15 degrees



   Connection



50 ohm N-type RF out



   Equipment



50 ft. low loss RF cable, and sturdy stainless steel pole mounts



 



 



PHYSICAL



 



Location



All switches/connections/LED are required to be on one side similar to the current design. There should be consideration to the configuration of the PETRA installation. The current design allows for a "standing" installation or installation lying down on its side. We would like to retain these options.



 



 



Switches



Power On/Off switch, and High Gain/Low Gain switch, each with a cover to protect from accidental switching



Connections



 



   Inputs



 



          AC Power



MILSPEC locking connector, which includes weather-sealed 6ft power cable



          RF



Two 50 ohm N-type connectors labeled FWD and AFT



   Outputs



 



          RF Antenna



50 ohm N-type connecter labeled ANT



          RF Monitor



Two 50 ohm N-type connector labeled MON



Indications



 



       Visual



Two LED Indicators, POWER ON and TRANSMITTING



       Audio



A loud audible tone to indicate system is transmitting



Dimensions



One side no greater than 8", two sides no greater than 12", Maximum volume of 1152 cubic inches



Weight



No greater than 30 lbs.



 



 



ENVIRONMENTAL



 



Operating Temperature



50 to 140 degrees F



Relative Humidity



15 to 95%



Storage Temperature



-4 to 158 degrees F



Material



Ruggedized and resistant to heavy shock and vibration, water and EMI



 



 



Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Pre-Exit Telemetry Retransmission and Amplifications System (PETRA) Latest Award Notice
Pre-Exit Telemetry Retransmission and Amplifications System (PETRA) Award Notice
Pre-Exit Telemetry Retransmission Amplification System (PETRA) Award Notice