The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY) is soliciting offers for the procurement of various copper-nickel pipe, elbows, and fittings. The required items include 20 feet of 5-inch OD pipe tubing, 3 each 5-inch 90-degree short radius elbows, 2 each 5-inch 200# butterfly flanges, 2 each 6-inch tees, 1 each 6-inch 45-degree elbow, and 3 each 6-inch 90-degree short radius elbows. The items must conform to various military specifications such as MIL-T-16420, MIL-F-24202, and MIL-F-20042. Quotes are due by 12:00 PM EST on June 5, 2024, and the anticipated delivery date is 30 days after contract award.

This procurement is set aside for small business concerns under NAICS code 326122 (Plastics Pipe and Pipe Fitting Manufacturing) with a size standard of 500 employees. The solicitation number is SPMYM123Q0108 and will be available electronically on SAM.gov on or about May 28, 2024. The place of performance is Portsmouth, VA 23709, USA.

Notice text

The Defense Logistics Agency (DLA) Maritime Norfolk at Norfolk Naval Shipyard (NNSY) intends to award a Firm Fixed Price (FFP) Single Award Contract for the items listed below. The required items are for commercial items prepared in accordance with the information in FAR Part 13 and FAR Subpart 12.6, as supplemented with the additional information included in this notice.

The Contract Line Items (CLINs) are as follows:

Clin 0001-4108C016 PIPE (TUBING) 5" (5.563" OD) .220W 70/30 CL700 , PART# 720700.650 MIL-T-16420K AMD 1

Quantity: 20 FT

Ordering data

a) Tube, Copper-Nickel Alloy, Seamless and Welded (Copper Alloy Numbers 715 and 706), MIL-T-

16420K Amendment 1 16 September 1988

b) 70-30, Annealed, Type I, Class 700, Grade 1

c) Hydrostatic Testing Required IAW 4.4.3

d) N/A

e) N/A

f) N/A

g) N/A

h) Dimensions IAW 5” NPS Class 700 straight tube (0.220” minimum thickness)

i) N/A

j) 20 ft

k) Tube marking is required per 3.10

l) An inspection per 4.1.1 is required

m) N/A

n) Level C packaging, packing and marking

o) N/A

OQE Ordering Requirements for CIM

Provide written verification that the chemical and mechanical properties have been determined and are

acceptable IAW the required specification MIL-T-16420 as applicable for document 4108C016 are as follows:

a.) Provide written verification that the chemical analysis and mechanical properties tests have been

determined and are acceptable. All test reports will contain a signed certification that the results represent the

actual values for the material provided and that they are in full compliance with the contract specification.

Material certification data shall be recorded on the testing company's letterhead and shall bear the name, title and

signature of the authorized company representative. The name and title shall be clearly legible. Certification data

supplied to the government shall be either the original mill material certification, the original copy from the testing

facility, or exact photocopies of these documents. The data forwarded by the manufacturer shall contain a signed

certification that the reported results represent the actual attributes of the material furnished and indicate full

compliance with all applicable specification and contract requirements. Statements on material certification

documents must be positive and unqualified. The material certification data reports shall include quantitative data

representing the actual values obtained during testing.

b.) Test reports will list all verified attributes and will be traceable to the material via a heat, lot, or batch

number applied to the material by the manufacturer. Each piece of material must be marked with the applicable

heat, lot, or batch number shown on the test reports provided. In the case of a finished product identified by a lot

number manufactured from a start material identified by a heat number, the final test reports performed on the

finished product samples shall be marked with the lot number. The test reports for the raw material shall be

marked with the heat number of that material.

c.) Test reports labeled "Typical," those with words such as "to the best of our knowledge" or "we believe

the information contained herein is true" or those that have results transcribed from other reports or documents,

or test reports with the heat/lot/batch number information handwritten on them are not acceptable.

d.) Test reports for loose MIL-DTL-1222, K-Monel (QQ-N-286), fasteners and for all assemblies which

contain MIL-DTL-1222 K-Monel fasteners, shall include a certification statement describing the forming process

used to manufacture the fasteners (i.e. hot headed with cold rolled threads, hot headed with machined threads,

etc.), the heat treatments performed, and the order in which these actions were performed (i.e., fasteners

manufactured and then solution annealed and age hardened, etc.). This action is required to ensure compliance

with MIL-DTL-1222, paragraph 3.3.4, which requires fasteners with formed heads (i.e., hot headed, cold headed,

etc.) and rolled threads to be solution annealed and age hardened after the manufacturing process.

e) Certifications for QQ-N-286 Rev G materials shall show that slow strain rate tensile {SSRT} test of “start

material” has been accomplished per QQ-N-286 Rev G requirements.

f.) Where headed fastener specifications require a yield strength test AND a wedge tensile test, a separate

(new, untested) fastener is required for each of the two test methods, and both of these tests shall be reported.

NOTE: This does not apply to steel hex head fasteners (grades 2, 5, 8, B7, and B16) are certified to a proof load and

NOT yield strength; therefore, this issue does NOT apply to those fasteners.

NOTE: This does apply to All CRES and non-ferrous bolts and screws, and ALL steel socket head cap screws

(grade A574 and 4340).

Wedge tensile test a required test for including ones that had their yield strength and tensile strength certified by

alternative testing IAW MIL-DTL-1222.

Clin 0002- 4108C017 ELBOW 5" BUTT WELD SHORT RADIUS 90 DEG CUNI 70/30 CL700 PART# 6027101.650 MIL-F-24202

Quantity: 3 ea

Ordering data

a) Fittings, Butt-Welding, Seamless or Welded, 70-30 Copper-Nickel Alloy, 700 PSI, 200 °F, MIL-F-

24202 w/ AMENDMENT 1 26 July 1985

b) Ty I or II is acceptable

c) N/A

d) Commercial packaging

e) 5” NPS 90 degree short radius elbow

f) Dimensions are IAW Table II, Table III, Table VII, and Figure 3 of MIL-F-24202.

g) 3 (ea)

Additional Information: Burst testing not required

Clin 0003-4108C018 FLANGE 5" 200# BUTTERFLY FLANGE CUNI 70/30 PART# 687188.700 MIL-F-20042 DWG 810- 4715319 2C REV E

Quantity: 2 ea

Ordering data:

5” Butterfly Flange

8.1) Flange

8.2) 5” NPS,

8.3) Item Number 6

8.4) Figure 2-C

8.5) 200 psi

8.6) CuNi (70/30) Alloy

8.7) NAVSEA Drawing 810-4715319 Rev. E

8.8) SPECIFICATION: MIL-F-20042

Flange, 5” NPS, Item Number 6, Figure 26-D (socket weld), 200 psi, CuNi (70/30) Alloy, NAVSEA Drawing

810-4715319 Rev. E,

Clin 0004 4108C019 TEE 6" 70/30 BW CL700 P/N 6027121.700 MIL-F-24202

Quantity: 2 ea

a) Fittings, Butt-Welding, Seamless or Welded, 70-30 Copper-Nickel Alloy, 700 PSI, 200 °F, MIL-F-

24202 w/ AMENDMENT I 26 July 1985

b) Ty I or II is acceptable

c) N/A

d) Commercial packaging

e) 6” NPS Tee

f) Dimensions are IAW Table II, Table III, Table VI, and Figure 5 of MIL-F-24202.

g) 2 (ea)

Additional Information: Burst testing not required

Clin 0005 4108C020 ELBOW 6" 70/30 45 DEG. BW . CL700 PART# 6027104.700 MIL-F-24202

Quantity: 1 ea

Ordering data:

a) Fittings, Butt-Welding, Seamless or Welded, 70-30 Copper-Nickel Alloy, 700 PSI, 200 °F, MIL-F-

24202 w/ AMENDMENT 1 26 July 1985

b) Ty I or II is acceptable

c) N/A

d) Commercial packaging

e) 6” NPS 45 degree elbow

f) Dimensions are IAW Table II, Table III, Table VII, and Figure 4 of MIL-F-24202.

g) 1 (ea)

Additional Information: Burst testing not required

Clin 0006 4108C021 ELBOW 6". 70/30 SHORT RADIUS 90 DEG BUTT WELD CUNI CL700 PART# 6027101.700 MIL-F-24202

Quantity: 3 ea

Ordering data:

a) Fittings, Butt-Welding, Seamless or Welded, 70-30 Copper-Nickel Alloy, 700 PSI, 200 °F, MIL-F-

24202 w/ AMENDMENT 1 26 July 1985

b) Ty I or II is acceptable

c) N/A

d) Commercial packaging

e) 6” NPS 90 degree short radius elbow

f) Dimensions are IAW Table II, Table III, Table VII, and Figure 3 of MIL-F-24202.

g) 3 (ea)

Additional Information: Burst testing not required

The requirement will be solicited as a total small business set aside. The NAICS code applicable to this procurement is 326122, Plastics Pipe and Pipe Fitting Manufacturing with a size standard of 500. The Product Service Code is 4730, Plastics Pipe and Pipe Fitting Manufacturing.

The anticipated delivery date for this acquisition is 30 days after contract award. The solicitation, any documents related to this procurement, and all amendments issued will be in electronic form only. THE SOLICITATION IS NOT YET AVAILABLE.

The solicitation number is SPMYM123Q0108, and it is expected to be available on or about 28 MAY 2024 and posted to SAM.gov, https://sam.gov/  Quotes will be due by 12:00 PM EST on 05 JUNE 2024. Responses to the solicitation notice shall be emailed to the attention of Sheree McDonnell at sheree.mcdonnell@dla/mil. Please make sure that the solicitation number (SPMYM123Q0108) is included in the subject line of any email correspondence. Emails without subject lines will not be read because of security issues.

Potential offerors are hereby notified that the solicitation and any subsequent amendments will only be available by downloading the documents at www.SAM.gov (Contracting Opportunities). The Government is not responsible for inability of the Offeror's to access solicitation documents posted. No telephone or FAX requests will be accepted, and no hardcopy solicitation/amendment will be mailed or faxed.

All responsible sources may submit a proposal which may be considered by the Government. By submitting a quote, the offeror will be self-certifying that neither the principal corporate officials nor owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the proposal. By submission of a proposal, the offeror acknowledges the requirement that a prospective awardee must be registered in the System for Award Management (SAM) database prior to award, during performance, and through final payment of any contract resulting from the solicitation, except for awards to foreign vendors for work to be performed outside the United States. Lack of registration in the SAM database will make an offeror ineligible for award. Offerors may obtain information on registration and annual confirmation requirements by calling 1-866-606-8220, or via the Internet at https://www.sam.gov. All questions shall be submitted in accordance with the solicitation, dates, and procedures. Please direct all questions regarding this requirement to Sheree McDonnell at sheree.mcdonnell@dla/mil.

Attachments

Files attached to this notice, newest first
File Type Posted
RELEASED SOLICITATION SPMYM124Q0108.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Pipe, elbow, and fittings This notice · Latest solicitation Solicitation
Pipe, elbow, and fittings Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity