The Network Contracting Office 17 intends to award a firm-fixed price contract in accordance with FAR Part 12, Acquisition of Commercial Items for the purchase of CAAS Workstation (See description below). This is a Combined Synopsis/Solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Quotes are being requested and a written solicitation will not be issued. The solicitation number is 36C25719Q0818. This acquisition is issued as a Request for Quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2019-02TA May 6, 2019. The associated North American Industrial Classification System Code (NAICS) for this procurement is 541519 with a Small Business (SB) standard of 1000 employees. This acquisition is solicited as a set aside for SB.
This procurement is for new Equipment ONLY; no remanufactured or "gray market" items. All Equipment must be covered by the manufacturer's warranty.
***Brand-name or equal items accepted. However, similar items must meet or exceed selected technical capabilities of the listed equipment. ***
Responses to the solicitation are due by 31 May 2019 @ 0800 AM Central Time (CT) via e-mail: rolando.pasayan@va.gov
ITEM NO. DESCRIPTION QUANTITY UNIT ESTIMATED
OR STOCK NO. UNIT COST
-----------------------------------------------------------------------------
PIE000 1 CAAS 8.1 BASE MODULE
CAAS Workstation is a dedicated
analysis program for the
quantification of coronary and
peripheral arteries, analysis of left
and right ventricle of the heart, and
enhanced visualization of stent
deployment regions. The flexible GUI
layout enables analysis in both Cath
lab and workstation settings. Multiple
analyses can be performed
simultaneously and side by side. The
different workflows are: CAAS QCA,
CAAS QCA3D, CAAS QVA, CAAS LVA, CAAS
RVA, CAAS IV-LINQ and CAAS Stent
Enhancer. 1 EA
PIE010 2 CAAS 8.1 QCA
CAAS QCA (Quantitative Coronary
Analysis) is the worldwide accepted
standard for the assessment of
coronary artery dimensions. The QCA
workflow can assist in the selection
of the optimal size of balloon and
stent. QCA features single vessel and
bifurcation analysis including
calibration, automatic contour
detection, and quantification of the
severity of stenosis. Resulting
measurements:
Minimum luminal diameter
Reference diameter
Percentage diameter stenosis
Length stenotic segment
Bifurcation angles 1 EA
PIE011 3 CAAS 8.1 OPTION 3D QCA
CAAS QCA can be extended to CAAS QCA3D
which allows 3D analysis of single and
bifurcated coronary arteries based on
two angiographic projections. These
projections are used to calculate the
true geometric shape in 3D space and
create an interactive rendered view of
the artery of interest. The key
product features of CAAS QCA3D are:
Quantification of lesion length and
percentage stenosis in a 3D
reconstruction
Elimination of foreshortening and
out-of-plane magnification errors
Interactive 3D rendered view for
assessment of shape
Full automatic calibration: this
eliminates the need for manual input
Resulting measurements:
3D bifurcation angles
Minimum luminal diameter
Reference diameter
Percentage diameter stenosis
Length stenotic segment 1 EA
PIE070 4 CAAS vFFR ANALYSIS
Pie Medical Imaging developed a new
non-invasive analysis called vFFR
(vessel FFR). The new workflow is
available in CAAS Workstation 8.0.
CAAS vFFR calculates the pressure drop
and vFFR value in coronary vessels,
this will expand the cardiologists
tooling for patient diagnostics. vFFR
can be performed online during the
patient procedure without the need for
a pressure wire and hyperaemic agent.
The vFFR analysis builds a 3D coronary
reconstruction using two angiograms
and assesses pressure drop, resulting
in a vFFR value. Furthermore, with the
3D reconstruction anatomical lesion
information can be calculated, like
percentage stenosis. Pressure drop
and vFFR calculation based on 3D
vessel reconstruction:
Simple and fast workflow
X-Ray system independent
Additional stenosis measurements
510(k) Cleared, CE Marked and PMDA
Compliant Key Results:
Pressure drop in coronary artery
vFFR value
Quantification of percentage
stenosis and lesion length 1 EA
PIE030 5 CAAS 8.1 QVA
The CAAS QVA (Quantitative Vascular
Analysis) workflow offers fast and
intuitive peripheral vessel analysis,
including the abdominal aorta and the
carotid, renal, iliac and femoral
arteries. The QVA workflow features
single vessel analysis including
calibration, contour detection and
quantification of the severity of
stenosis. Resulting measurements:
Minimum luminal diameter
Reference diameter
Percentage diameter stenosis
Length stenotic segment
Area at minimum luminal diameter 1 EA
PIE010FL 6 FLOATING LICENSE FOR CAAS QCA 2 EA
PIE012FL 7 FLOATING LICENSE FOR CAAS QCA
RESEARCH 2 EA
PIE070FL 8 FLOATING LICENSE FOR CAAS vFFR
ANALYSIS
The floating license allows many users
to share the Pie Medical / 3mensio
analysis software across a facilities
network. It enables the application(s)
to be loaded on as many workstations
as desired. It is only limited by the
number of concurrent user connections
purchased; i.e.: single user only one
person can be using the application at
any given time. 2 users, 2 people can
be using the application at the same
time, etc. Floating licensing is
provided as either a software license
or hardcoded to a USB dongle and needs
to be located on the network, VLAN, or
VPN of the client systems. The
Floating license, single user, reduces
the cost of purchasing a second
standalone license by 75%. 2 EA
TOTAL COST:.