LI-600PF Porometer/Fluorometer

Closed Solicitation Posted

Solicitation number
12405B24Q0075
Agency
Southeast Area Field Research Implementation and Information Delivery, Department of Agriculture
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
334516 Analytical Laboratory Instrument Manufacturing
PSC
6640 Laboratory Equipment And Supplies
Place of performance
Mayaguez, Puerto Rico 00680, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery is seeking quotes for an LI-600PF Porometer/Fluorometer instrument that can measure both stomatal conductance and chlorophyll fluorescence on the same leaf area within 10 seconds. The solicitation requires the instrument incorporate built-in sensors for photosynthetically active radiation, orientation, location, and include an internal barcode scanner. Quotes are due no later than February 9, 2024 and will be evaluated based on technical compliance with requirements, past performance, and price.

There is no set-aside designation for this procurement. The NAICS code is 334516 and PSC code is 6510, with performance to take place in Mayagüez, Puerto Rico. Quotes should provide pricing for the instrument, shipping, and an optional two-year warranty extension. Award will be made using best value tradeoff procedures, with the contract to be firm-fixed-price. The government estimates a single instrument procurement up to $100,000 total value.

Notice text

List of equipment specifications:

  • The instrument must have the option to do both stomatal conductance and chlorophyll fluorescence on the same leaf area.
  • Built in Photosynthetically Active Radiation (PAR) sensor measures ambient light with each measurement.
  • Built in accelerometer/magnetometer to measure heading, pitch, and roll.
  • Built in GPS to record latitude, longitude, and altitude with every measurement.
  • Software calculates leaf angle of incident with data from accelerometer/magnetometer and GPS.
  • The instrument must have an internal bar code scanner to help with both repetition speed and data organization.
  • The instrument must include a software application to configure, calibrate, download and stream data.
  • The instrument desktop software must include a barcode generator for creating custom barcode labels.
  • The instrument must include a tripod mount for teaching and lab studies.
  • The instrument must be able to take a combined stomatal conductance and chlorophyll fluorescence measurement in less than 10 seconds.
  • The instrument aperture size must be 0.76 cm diameter to ensure the majority of leaf area morphologies can be measured.
  • Infrared leaf temperature (IRT) sensor eliminates the leaf contact point.
  • The instrument must be ergonomic and lightweight (<2lbs) for effortless measurements all day.
  • The instrument must have a display to show the instrument status and the last measurement.
  • The instrument must contain internal Lithium/Ion batteries for 8 hours of nominal operation.
  • The measurements must be made with one handed operation without a separate console.
  • Fluorometer must have options for both rectangular and multiphase flash events.

Attachments

Files attached to this notice, newest first
File Type Posted
12405B24Q0075.pdf PDF
Beta Sam Solicitation.docx DOCX document
Equipment Specificatios.docx DOCX document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity