Isotopic Water Analyzer
Closed Solicitation Posted
- Solicitation number
- W913E521Q0004
- Agency
- US Army Corps of Engineers Department of the Army, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- Place of performance
- Hanover NH 03755 USA
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
This combined synopsis/solicitation for commercial items prepared in accordance with the format at FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.
The solicitation number W913E521Q0004 is being issued as a request for quotation (RFQ).
The associated North American Industry Classification System (NAICS) code is 334516 – Analytical Laboratory Instrument Manufacturing.
The U.S. Army Engineer Research and Development Center (ERDC), Cold Regions Research and Engineering Laboratory (CRREL) has a requirement for an Isotopic Water and Vapor Analyzer with the following specifications:
Requirement
Details
Isotope Water Analyzer
Analyzer able to measure of 18O, D, 17O and 17O-excess in water or water vapor
Water Vaporizer
Required system component
Autosampler
Required system component
Monitor
Required system component
Onsite installation and training; One Day
Required system component
Desiccant Drier Kit
Required system component
Salt Liner Package
Required system component (to enable isotope analyses of high saline concentrations up to 20% concentration)
Pump
Required system component
Dry Gas “Zero Air” Kit
Required system component. This is defined as a gas plumbing and regulator kit that connects the isotope analyzer system to tanks containing compressed dry air or “Zero Air”.
Field Portable Analyzer (weight less than 50lbs, volume less than 2200 cubic inches)
Field Portable is defined as a system that can easily be carried into the field by a scientist for use in remote camps or boats for field analyses; specifically a field portable analyzer must weigh less than 50lbs and occupy less than 2200 cubic inches (i.e., the approximate size of a desktop computer) while meeting all the measurement precision and sensitivity standards of the DOR. Peripheral accessories (monitor, pump, tray) are generally minor so are not included in the above weight/volume limits.
Saline water sample concentrations
Isotope Analyzer must be able to measure accurately in saline water sample concentrations up to 20%
Independent Operation
Independent Operation means that the system does not require a separate computer for operation
Export Data File as .csv Format
Analyzer data files may be recorded in .csv compatible format for export
Analysis of matrix bound water in solid samples (OPTION)
The analyzer shall have the optionality to expand via add-on peripherals to allow analysis of matrix-bound water in solid samples (e.g., soils, leaf matter, wood matter)
Maximum 24-hour Drift (vapor and liquid)
δ18O = 0.2‰
δ17O = 0.2‰
δD = 0.8‰
17O-excess = 0.2‰
Data Output Modality
Digital (RS-232)
Ethernet
USB
Sample Conditions (Water Vapor)
Sample Temperature: -10 to 45°C
Operating Temperature: 10 to 35°C
Sample Conditions (Liquid Water)
Sample Temperature: 10 to 35°C
Operating Temperature: 10 to 35°C
Vapor Water Precision (1σ) at 12,500 ppm
δ18O = 0.12/0.04‰ at 10/100 sec
δD = 0.3/0.1‰ at 10/100 sec
Vapor Water Precision (1σ) at 12,500 ppm
δ18O at 300 sec = 0.04‰
δ17O at 300 sec = 0.04‰
δD at 300 sec = 0.1‰
17O-excess at 3600 sec = 0.015‰
Liquid Water Sample Precision (1σ)
δ18O = 0.025‰
δ17O = 0.025‰
δD = 0.1‰
17O-excess = 0.015‰
Equipment Warranty
A warranty of at least 12 months is required
Please reference the attached RFQ for applicable provisions and clauses. The following factors shall be used to evaluate offers: ability to meet the required technical specifications and price.
Please provide responses to this notice, no later than Thursday, February 4, 2021, 12:00 PM, Eastern Standard Time (EST) to:
William.A.McFarland@usace.army.mil
Telephone responses will not be accepted.
*Note: In order to be eligible for award of a Government contract, vendors must be actively registered in the System for Award Management (SAM), have no active exclusions, and complete representations and certifications.
Update #1 ·
This combined synopsis/solicitation for commercial items prepared in accordance with the format at FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.
The solicitation number W913E521Q0010 is being issued as a request for quotation (RFQ).
The associated North American Industry Classification System (NAICS) code is 334516 – Analytical Laboratory Instrument Manufacturing.
The U.S. Army Engineer Research and Development Center (ERDC), Cold Regions Research and Engineering Laboratory (CRREL) has a requirement for an Isotopic Water and Vapor Analyzer with the following specifications:
Requirement
Details
Isotope Water Analyzer
Analyzer able to measure of 18O, D, 17O and 17O-excess in water or water vapor
Water Vaporizer
Required system component
Autosampler
Required system component
Monitor
Required system component
Onsite installation and training; One Day
Required system component
Desiccant Drier Kit
Required system component
Salt Liner Package
Required system component (to enable isotope analyses of high saline concentrations up to 20% concentration)
Pump
Required system component
Dry Gas “Zero Air” Kit
Required system component. This is defined as a gas plumbing and regulator kit that connects the isotope analyzer system to tanks containing compressed dry air or “Zero Air”.
Field Portable Analyzer (weight less than 50lbs, volume less than 2200 cubic inches)
Field Portable is defined as a system that can easily be carried into the field by a scientist for use in remote camps or boats for field analyses; specifically a field portable analyzer must weigh less than 50lbs and occupy less than 2200 cubic inches (i.e., the approximate size of a desktop computer) while meeting all the measurement precision and sensitivity standards of the DOR. Peripheral accessories (monitor, pump, tray) are generally minor so are not included in the above weight/volume limits.
Saline water sample concentrations
Isotope Analyzer must be able to measure accurately in saline water sample concentrations up to 20%
Independent Operation
Independent Operation means that the system does not require a separate computer for operation
Export Data File as .csv Format
Analyzer data files may be recorded in .csv compatible format for export
Analysis of matrix bound water in solid samples (OPTION)
The analyzer shall have the optionality to expand via add-on peripherals to allow analysis of matrix-bound water in solid samples (e.g., soils, leaf matter, wood matter)
Maximum 24-hour Drift (vapor and liquid)
δ18O = 0.2‰
δ17O = 0.2‰
δD = 0.8‰
17O-excess = 0.2‰
Data Output Modality
Digital (RS-232)
Ethernet
USB
Sample Conditions (Water Vapor)
Sample Temperature: -10 to 45°C
Operating Temperature: 10 to 35°C
Sample Conditions (Liquid Water)
Sample Temperature: 10 to 35°C
Operating Temperature: 10 to 35°C
Vapor Water Precision (1σ) at 12,500 ppm
δ18O = 0.12/0.04‰ at 10/100 sec
δD = 0.3/0.1‰ at 10/100 sec
Vapor Water Precision (1σ) at 12,500 ppm
δ18O at 300 sec = 0.04‰
δ17O at 300 sec = 0.04‰
δD at 300 sec = 0.1‰
17O-excess at 3600 sec = 0.015‰
Liquid Water Sample Precision (1σ)
δ18O = 0.025‰
δ17O = 0.025‰
δD = 0.1‰
17O-excess = 0.015‰
Equipment Warranty
A warranty of at least 12 months is required
Please reference the attached RFQ for applicable provisions and clauses. The following factors shall be used to evaluate offers: ability to meet the required technical specifications and price.
Please provide responses to this notice, no later than Thursday, February 4, 2021, 12:00 PM, Eastern Standard Time (EST) to:
William.A.McFarland@usace.army.mil
Telephone responses will not be accepted.
*Note: In order to be eligible for award of a Government contract, vendors must be actively registered in the System for Award Management (SAM), have no active exclusions, and complete representations and certifications.
Attachments
| File | Type | Posted |
|---|---|---|
| B08.02 RFQ W913E521Q0004.pdf |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity