Hazardous Material Buildings
Awarded Award Notice Posted
- Solicitation number
- W91364-16-R-0005
- Agency
- Ohio National Guard Army National Guard, Department of Defense
- Awarded
- to Environmental Compliance Products, Inc.
- Set-aside
- Total Small Business
Opportunity facts
- Contract number
- W91364-16-P-0054 Federal contract award
- NAICS code
- 332311 Prefabricated Metal Building and Component Manufacturing
- PSC
- Not on record
- Place of performance
- See CLIN0001: Locations, and CLIN0002: Locations., Ohio, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Added: Apr 19, 2016 1:36 pm
1. Will 54" doors would be acceptable instead of 56" doors?
Yes
2. We can insulate the building but I would like to know if you wanting it in the walls, ceiling and floor or just the walls?
Floors, walls, and ceiling. Insulation is primarily to protect from extreme weather conditions.
3. How many tiers of shelving are you needing inside each building?
2 Tiers of shelving.
4. Would each of these locations have the capability to unload these buildings on site, or would that cost need to be included in the quote as well ?
No, the locations do not have the capability to offload the buildings. Offloading and installation is the contractors responsibility.
5. Which electrical Classification and Division?
No electric
6. What substances will be stored in the building?
The majority of stored substance is POL, solvents, and paint waste.
7. Which sensors are required in the building?
None
8. Liquid detection?
None
9. Heavier than air fume detection?
None
10. Are explosion relief panels required?
Yes
11. What type of fire suppression?
None
12. Water, dry chem, Halon?
None
13. Are fork lift tubes in the base desired for ease of moving the building?
Yes
14. Is 24/7 ventilation needed with a back-up exhaust fan?
No
15. Will the building need to be heated and/or air conditioned?
No
16. Our standard building is 16 x 8 x 9, is this acceptable?
Square footage as determined by length and width but cannot exceed 10% of original scope dimensions. Also, dimensions for length, width, and height cannot deviate more than 6in from original scope dimensions. Spacing is limited at these locations, therefore dimensions specified are critical. Please send cut sheets with building sizes and dimensions with quote.
17. You call out a partition wall, do you want this centered in the building?
Yes
18. Does the partition wall need to be fire rated?
Yes
19. You call out for insulation, but you have not requested any temperature control.
Insulation will not provide any value to the building without heating/cooling options.
Update #1 ·
Added: Mar 25, 2016 1:35 pm
(I) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued.
(II) Solicitation W91364-16-R-0005 is issued as a Request for Proposal (RFP).
(III) This requirement is being issued as a Request for Proposal (RFP). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-83.
(IV) This procurement is a 100% Small Business set-aside IAW FAR 19.502-2 (a). The NAICS code is 332311 and the small business size standard is 500 Employees. The following commercial items are requested in this solicitation:
(V) SCHEDULE OF SUPPLIES/SERVICES:
CLIN 0001:
Steel Building: Nine (9) prefabricated welded steel constructed buildings with the dimensions of 15'x 9'x 9'; interior separation wall with two (2) 56" doors that open on corner posts. The buildings will be constructed with 12 gauge noncommercial grade A-570 steel and a coating that includes two-part anti-corrosive epoxies and polyurethanes which serve as insulators from climactic variations. The buildings will contain secondary containment shelving that can be adjusted to fit any size containers. The non-combustible or gypsum board insulation will have a 2 hour fire rating.
Hazardous waste storage buildings are designed to store hazardous waste in a safe, segregated and secure area, and to prevent chemicals from leaking out into the environment in case of a spill. The buildings must have the following features:
a. Prefabricated welded steel constructed building
b. One-piece sump with drain fittings to contain any leaks or spills
c. Secondary containment shelving
d. Grounding rod and cable
e. Steel loading ramps at each door
f. 2 hour fire rated insulation
Secondary Containment Sump: Must be at least a 6-7" deep well in the bottom of the prefabricated steel building which is continuously welded to be "leak-proof'. The sump must contain drain fittings and covered by a steel floor grating.
Finishes: The building will include a protective coating that will serve as insulators from climactic variations.
Ramps: Two heavy duty steel ramps, one for each 56" door.
Locations:
(1) 15'x9'x9' Building- 3000 Symmes Rd., Hamilton, Ohio 45015
(1) 15'x9'x9' Building- 2555 County Line Rd., Kettering, Ohio 45430
(2) 15'x9'x9' Building- 855 South Collett St., Lima, Ohio 45804
(1) 15'x9'x9' Building- 1000 Lawrence Rd., Bldg 2008, Port Clinton, Ohio 43452
(1) 15'x9'x9' Building- 7246 2nd St., Bldg 846, Columbus, Ohio 43217
(1) 15'x9'x9' Building- 1438 SR 534 SW., Newton Falls, Ohio 44444
(1) 15'x9'x9' Building- 6000 West Airport Dr., Green, Ohio 44720
(1) 15'x9'x9' Building- 7750 South Access Rd., Bldg 918, Columbus, Ohio 43217
CLIN 0002:
Steel Building: Two (2) prefabricated welded steel constructed buildings with the dimensions of 7'x 9'x 9' with one (1) 56" door. The buildings will be constructed with 12 gauge noncommercial grade A-570 steel and a coating that includes two-part anti-corrosive epoxies and polyurethanes which serve as insulators from climactic variations. The buildings will contain secondary containment shelving that can be adjusted to fit any size containers. The non-combustible or gypsum board insulation will have a 2 hour fire rating. One heavy duty steel ramps for the 56" door.
Hazardous waste storage buildings are designed to store hazardous waste in a safe, segregated and secure area, and to prevent chemicals from leaking out into the environment in case of a spill. The buildings must have the following features:
g. Prefabricated welded steel constructed building
h. One-piece sump with drain fittings to contain any leaks or spills
i. Secondary containment shelving
j. Grounding rod and cable
k. Steel loading ramps at each door
l. 2 hour fire rated insulation
Secondary Containment Sump: Must be at least a 6-7" deep well in the bottom of the prefabricated steel building which is continuously welded to be "leak-proof'. The sump must contain drain fittings and covered by a steel floor grating.
Finishes: The building will include a protective coating that will serve as insulators from climactic variations.
Ramps: Two heavy duty steel ramps, one for each 56" door.
Locations:
(1) 7'x9'x9' Building- 8208 South Perimeter Rd., Columbus, Ohio 54217
(1) 7'x9'x9' Building- 1438 SR 534 SW., Newton Falls, Ohio 44444
Please include any additional overage charges, delivery-pickup charges, delivery fee in your quote.
(VI) The provision FAR 52.212-1, Instructions to Offerors, Commercial in its latest edition applies to this
solicitation.
(VII) Quotes will be technically evaluated for conformance with the requirements of paragraph (V). Technical acceptance will be determined on a pass/fail basis. The government intends to award a contract to the lowest priced technically acceptable quote without discussions. The government, however, reserves the right to conduct discussions if deemed in the best interest of the government.
(VIII) Offerors are to include a completed copy of the provision at 52.212-3 Alt 1, Offeror Representations and Certifications - Commercial Items with their offer. This can be completed electronically at https://sam.gov/.
(IX) The clause FAR 52.212-4, Contract Terms and Conditions - Commercial Items in its latest edition applies to this solicitation.
(X) The following clauses in their latest editions apply to this acquisition:
FAR
52.212-5 (Deviation), Contract Terms and Conditions Required to Implement Statutes or Executive Orders
52.204-7, System for Award Management
52.204-9, Personal Identity Verification of Contractor Personnel
52.204-10, Reporting Executive Compensation and First-Tier Subcontract Awards
52.204-13, System for Award Management Maintenance
52.204-16, Commercial and Government Entity Code Reporting
52.204-18, Commercial and Government Entity Code Maintenance
52.212-2, Evaluation-Commercial Items
52.219-6, Notice of Total Small Business Set-Aside
52.219-28, Post Award Small Business Program Representation
52.222-36, Equal Opportunity for Workers with Disabilities
52.223-18, Encouraging Contractor Policies to Ban Text Messaging While Driving
52.225-13, Restrictions on Certain Foreign Purchases
52.232-33, Payment by Electronic Funds Transfer--Central Contractor Registration
52.233-3, Protest After Award
52.233-4, Applicable Law for Breach of Contract Claim
52.237-1, Site Visit
52.237-2 Protection of Government Buildings, Equipment and Vegetation
52.252-2, Clauses Incorporated by Reference
52.252-6, Authorized Deviations in Clauses
DFARS
252.203-7000, Requirements Relating to Compensation of Former DOD Officials.
252.203-7002, Requirement to Inform Employees of Whistleblower Rights
252.203-7005, Representation Relating to Compensation of Former DOD Officials
252.203-7996, Prohibition on Contracting with Entities that Require Certain internal Confidentiality Agreements-Representation (DEVIATION)
252.230-7997, Prohibition on Contracting with Entities that Require Certain Internal Confidentiality Agreements (DEVIATION)
Representation (DEVIATION 2015-O0010)
252.204-7011, Alternative Line Item Structure
252.209-7992, Representation by Corporations Regarding an Unpaid Delinquent Tax Liability or a Felony
Conviction under any Federal Law-Fiscal Year 2015 Appropriations
252.225-7048, Export-Controlled Items
252.232-7003, Electronic Submission of Payment Requests
252.232-7010, Levies on Contract Payments
Additional FAR clauses cited within the above clauses, which are applicable, will be incorporated into the
solicitation and the resulting contract.
(XI) All information relating to this solicitation, including, changes/amendments, questions and answers, will be posted on the following website: http://www.FBO.gov. Formal communications such as request for clarifications and/or information concerning this solicitation must be submitted in writing or via e-mail to the address below. All answers (on a non-attribution basis) will be posted on the acquisition.army.mil web site. They will be contained in a document titled quote mark Questions and Answers quote mark. Offerors are requested to submit questions to the email address noted below not later than, 12:00 P.M. EST, 19 April 2016. Terms of the solicitation and specification remain unchanged unless the solicitation is amended in writing. If an amendment is issued, normal procedures relating to the acknowledgement and receipt of solicitation shall apply. Award can only be made to contractors registered in SAM (http://www.sam.gov).
Email questions no later than 12:00 P.M. EST, 19 April 2016. All responsible sources may submit a response which, if timely received, must be considered by the agency. Emailed quotes will be accepted and is the preferred method no later than 12:00 P.M. EST 22 April 2016, at randy.d.reis.mil@mail.mil and/or mark.h.miesse.civ@mail.mil. Point of Contact for this solicitation is Randy Reis; randy.d.reis.mil@mail.mil, 614-336-7001.
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity