Ground Penetrating Radar

Cancelled Solicitation Posted

Solicitation number
2121451PKF163
Agency
Coast Guard Department of Homeland Security
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
237130 Power and Communication Line and Related Structures Construction
PSC
C213 Architect And Engineering- General: Inspection (Non-Construction)
Place of performance
Kodiak, Alaska 99619, United States

Notice details come from SAM.gov. Updated .

Notice text

3 versions

Update #3 · Latest ·

Update to this solicitation.  Due to funding constraints this requirement is cancelled.

Requesting quotes for a Ground Penetrating Radar with the following requirements:

Must be able to locate and mark:

- Metal utilities, including pipes and cables

- Non-metallic pipes, including PVC and asbestos cement

- Concrete storm and sewer systems

- Utilities where installed tracer wiring has failed

- Underground storage tanks and drainage tiles

- Septic system components

- Non-utility structures such as vaults, foundation walls and concrete pads

Must be able to penetrate to a depth of up to 26 ft with high resolution.

Must have an integrated GPS receiver for geo-referencing data.

Must be able to export geo-referenced data to .csv files.

Provide free interactive, online and on-demand courses on utility locating with GPR.

Award will be based on lowest price technically acceptable. 

For questions contact SKC Mason Ferril at mason.s.ferril@uscg.mil.

Update #2 ·

Requesting quotes for a Ground Penetrating Radar with the following requirements:

Must be able to locate and mark:

- Metal utilities, including pipes and cables

- Non-metallic pipes, including PVC and asbestos cement

- Concrete storm and sewer systems

- Utilities where installed tracer wiring has failed

- Underground storage tanks and drainage tiles

- Septic system components

- Non-utility structures such as vaults, foundation walls and concrete pads

Must be able to penetrate to a depth of up to 26 ft with high resolution.

Must have an integrated GPS receiver for geo-referencing data.

Must be able to export geo-referenced data to .csv files.

Provide free interactive, online and on-demand courses on utility locating with GPR.

Award will be based on lowest price technically acceptable. 

For questions contact SKC Mason Ferril at mason.s.ferril@uscg.mil.

Update #1 ·

GPR Requirements

Must be able to locate and mark:

- Metal utilities, including pipes and cables

- Non-metallic pipes, including PVC and asbestos cement

- Concrete storm and sewer systems

- Utilities where installed tracer wiring has failed

- Underground storage tanks and drainage tiles

- Septic system components

- Non-utility structures such as vaults, foundation walls and concrete pads

Must be able to penetrate to a depth of up to 26 ft with high resolution.

Must have an integrated GPS receiver for geo-referencing data.

Must be able to export geo-referenced data to .csv files.

Provide free interactive, online and on-demand courses on utility locating with GPR.

Award will be based on lowest price technically acceptable. 

For questions contact SKC Mason Ferril at mason.s.ferril@uscg.mil.

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities