Added: Jun 09, 2016 5:32 pm The Department of Veteran Affairs, Jack C Montgomery medical center, 1011 Honor Heights Dr, Muskogee, OK 74401 is seeking to replace existing dental chairs and dental handpieces. This replacement of chairs shall include the contractor to perform the installation of the dental chairs to three treatment rooms. The existing chairs will be removed by VA employees prior to the installation date that is coordinated at time of award. New equipment procured must be compatible with existing ADEC equipment that will remain within the department for use.



Items requested or Brand name, ADEC, or comparable

Items must meet minimum salient characteristics below to meet technically acceptable.



Minimum Requirements to continue care of patients.



Adec 500 Dental Chair Model 511 brand name or equal

Double Articulating Headrest

Cover upholstery that is able to withstand disinfection after each patient.

Multi-position armrests

Floor Box

Footswitch

Chair Stop Plate

Swivel Brake

Program chair preset positions (Treatment 1 and Treatment 2)

Double-articulating headrest that can accommodate patients in a wheel chair.



Adec 500 Delivery Systems Model 532 brand name or equal

Standard Touch pad

Adjustable Holder

Tray Holder

Master Toggle

FlexArm Brake

Foot Control Wet/Dry Toggle

Self-contained water system

Deluxe touchpad that controls: chair, cuspidor, light, handpieces, and electric motors.

Endodontics Mode Programming

Attachment ratio setting

Warning beep indicator

File torque limit/unit indicator

Forward/reverse and torque mode indicator

File speed setting

Water coolant adjustment keys

Air coolant adjustment key

Piezo attachment

Electric Motor LED System

Floor boxes must hook into existing Adec air/water lines and chairs must be air driven.

Must work on air at a minimum of 80 psi

Must work on water at a minimum of 40 psi

Must work on Vacuum at 12cfm at 8 inches of mercury



ADDITIONAL MINIMUM REQUIREMENTS

- Handpieces must connect to existing Adec motors

- Handpieces must have sterilization instructions for gravity and or prevac. Gravity can only be up to 270 degrees.

- Installation must be included and warrantied.

- Warranty begins once equipment has been installed.

Attachments

Files attached to this notice, newest first
File Type Posted
VA256-16-Q-0803-001.docx DOCX document
VA256-16-Q-0803-000.docx DOCX document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity