DENTAL CHAIRS And Handpieces, includes installation chairs
Awarded Award Notice Posted
- Solicitation number
- VA25616Q0803
- Agency
- Veterans Integrated Service Network 16 Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to R & M Government Services Inc.
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- Contract number
- VA25616P0893 Federal contract award
- NAICS code
- 339114 Dental Equipment and Supplies Manufacturing
- PSC
- Not on record
Notice details come from SAM.gov. Updated .
Notice text
Added: Jun 09, 2016 5:32 pm
The Department of Veteran Affairs, Jack C Montgomery medical center, 1011 Honor Heights Dr, Muskogee, OK 74401 is seeking to replace existing dental chairs and dental handpieces. This replacement of chairs shall include the contractor to perform the installation of the dental chairs to three treatment rooms. The existing chairs will be removed by VA employees prior to the installation date that is coordinated at time of award. New equipment procured must be compatible with existing ADEC equipment that will remain within the department for use.
Items requested or Brand name, ADEC, or comparable
Items must meet minimum salient characteristics below to meet technically acceptable.
Minimum Requirements to continue care of patients.
Adec 500 Dental Chair Model 511 brand name or equal
Double Articulating Headrest
Cover upholstery that is able to withstand disinfection after each patient.
Multi-position armrests
Floor Box
Footswitch
Chair Stop Plate
Swivel Brake
Program chair preset positions (Treatment 1 and Treatment 2)
Double-articulating headrest that can accommodate patients in a wheel chair.
Adec 500 Delivery Systems Model 532 brand name or equal
Standard Touch pad
Adjustable Holder
Tray Holder
Master Toggle
FlexArm Brake
Foot Control Wet/Dry Toggle
Self-contained water system
Deluxe touchpad that controls: chair, cuspidor, light, handpieces, and electric motors.
Endodontics Mode Programming
Attachment ratio setting
Warning beep indicator
File torque limit/unit indicator
Forward/reverse and torque mode indicator
File speed setting
Water coolant adjustment keys
Air coolant adjustment key
Piezo attachment
Electric Motor LED System
Floor boxes must hook into existing Adec air/water lines and chairs must be air driven.
Must work on air at a minimum of 80 psi
Must work on water at a minimum of 40 psi
Must work on Vacuum at 12cfm at 8 inches of mercury
ADDITIONAL MINIMUM REQUIREMENTS
- Handpieces must connect to existing Adec motors
- Handpieces must have sterilization instructions for gravity and or prevac. Gravity can only be up to 270 degrees.
- Installation must be included and warrantied.
- Warranty begins once equipment has been installed.