Cryogen Free Cryostat
Awarded Award Notice Posted
- Solicitation number
- SB1341-15-RQ-0608
- Agency
- National Institute of Standards and Technology Department of Commerce
- Awarded
- to Montana Instruments Corporation
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- SB1341-15-SU-0610 Federal contract award
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- Not on record
- Place of performance
- 100 Bureau Drive Gaithersburg, Maryland 20899, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Added: Jul 16, 2015 2:06 pm
Amendment I:
The purpose of this amendment is revise the minimum required specification on specification 11 and to extend the due date for quotes as follows:
Specification 11 is hereby revised as follows:
FROM:
11. Must include a cryogenic and vacuum compatible XYZ nanopositioning stage mounted to cryostat cold plate. The stage must have at least 3mm of travel in each direction with 10 nm scale resolution at cryogenic temperatures. The positioners must supply at least 25 g of force in each direction. All wiring inside the cryostat, electrical feedthrough connections, and air-side cabling must be provided. An electronic controller capable of controlling all three axes must be provided. The stage controller must be computer controllable. The footprint of the stage must take up less than one half of the cryostat cold plate area.
TO:
11. Must include a cryogenic and vacuum compatible XYZ nanopositioning stage mounted to cryostat cold plate. In two directions (X and Y) the stage must have at least 3mm of travel in each direction with 50 nm scale resolution at cryogenic temperatures and supply at least 25 g of force. In the third direction (Z) the stage must have at least 2.5mm of travel with 50 nm scale resolution at cryogenic temperatures and supply at least 25 g of force. All wiring inside the cryostat, electrical feedthrough connections, and air-side cabling must be provided. An electronic controller capable of controlling all three axes must be provided. The stage controller must be computer controllable. The footprint of the stage must take up less than one half of the cryostat cold plate.
The due date for quotes has been extended as follows:
FROM: July 14, 2015 at 12 pm ET
TO: July 22, 2015 at 12 pm ET
All other terms and conditions and minimum required specifications remain unchanged.
Update #1 ·
Added: Jun 30, 2015 12:40 pm Please see the attached document entitled "SB1341-15-RQ-0608" for the complete solicitation details...
Attachments
| File | Type | Posted |
|---|---|---|
| SB1341-15-RQ-0608.docx | DOCX document |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity