Amendment 1 36C26026Q0357
Closed Special Notice Posted
- Solicitation number
- 36C26026Q0357_2
- Agency
- Veterans Integrated Service Network 20 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Place of performance
- Oregon 97408, United States
- Points of contact
-
- Maureen Sundstrom maureen.sundstrom@va.gov (253) 888-4935
Notice details come from SAM.gov. Updated .
About this opportunity
Amendment 1 to solicitation 36C26026Q0357 has been issued by the Department of Veterans Affairs Veterans Health Administration, Veterans Integrated Service Network 20 on behalf of the Eugene VA Medical Center. This amendment corrects the original solicitation document for the procurement of electrosurgical units. The solicitation is a total set-aside exclusively for certified Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The requirement falls under NAICS code 334510 (Electromedical and Electrotherapeutic Apparatus Manufacturing) with a 1,250-employee size standard. The procurement is structured as a Brand Name or Equal solicitation with Medtronic as the reference manufacturer.
The solicitation requires vendors to supply four line items: three Generator FT10 units, three Cart FT10 units, three Standard Footswitches, and three BIP Footswitches, with delivery required 30 days after receipt of order FOB Destination to Eugene, Oregon. Interested contractors must submit responses by March 2, 2026, at 8:00 AM PST and provide a completed SF1449 form, pricing schedules, limitations on subcontracting certificate, Buy American Certificate, technical specifications for equal products with descriptive literature, and a signed manufacturer authorization letter. Only SDVOSB-certified firms are eligible to compete for this contract. Offerors must demonstrate that their electrosurgical units meet specified technical requirements including sealing/fusion cycle time under four seconds, tissue impedance monitoring, multiple operational capabilities, and other functional specifications, along with providing a minimum one-year warranty and identifying the place of manufacture.
Notice text
The purpose of this Amendment is to correct the solicitation document. Please see the attached corrected copy.
Attachments
| File | Type | Posted |
|---|---|---|
| S02 36C26026Q0357 Electrosurgical Units.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Amendment 1 36C26026Q0357 | Special Notice | |
| 6515--Electrosurgical Units | Solicitation | |
| 6515--Electrosurgical Units | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity