About this opportunity

The Department of the Navy Naval Air Systems Command seeks preventative and emergency maintenance services for two Aluminum Ion Vapor Deposition systems located at Fleet Readiness Center Southeast in Jacksonville, Florida. The contractor must provide all necessary personnel, equipment, supplies, and materials to perform scheduled preventative maintenance, equipment self-testing to validate coating specifications, and emergent repair services. The opportunity is a sole source acquisition justified by the proprietary software copyright and service authorization held by Pregl Services as the sole provider. Proposals are due by July 15, 2022.

This requirement has no set-aside designation. The primary NAICS code is 238220 and PSC code is J067. The estimated value for the base period of July 2022 to June 2023 is $74,460 to be performed at Fleet Readiness Center Southeast in Jacksonville, Florida. Pregl Services is the incumbent and potential sole awardee given their proprietary software ownership and service authorization for the two specialized Aluminum Ion Vapor Deposition systems.

Notice text

The Contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform Preventive and Emergency maintenance on two (2) Aluminum Ion Vapor Deposition (AIVD) systems located at the Fleet Readiness Center Southeast (FRCSE), Naval Air Station (NAS) Jacksonville, FL 32212-0016. The Government will dispose of any debris and/or leftover materials upon completion of services. All work will be pre-scheduled and performed on-site. After each Preventive Maintenance (PM), an equipment self-test shall be conducted to ensure the systems can deposit Type I and Type II IVD Aluminum coating per specifications. Test acceptance must be completed in the presence of a Government Technical Representative (GTR). Contractor shall also provide Emergent Repair capability for both AIVD systems. The Contractor shall comply with all applicable laws and regulations, including but not limited to Federal Law, Florida State Law(s), Occupational Safety and Health Administration (OSHA) regulations, Navy and installation regulations. This work will be done on two AIVD specific systems, 1.AIVD System N65886011434 (serial # 41) and 2.AIVD System N65886014437 (serial # BM1255).

THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, all responsible sources may submit a capability statement, which, if received within two (2) calendar days after the date of the publication of this synopsis, will be considered. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. A determination by the Government not to compete this requirement based upon responses received as a result of this notice is solely within the discretion of the Government.

Attachments

Files attached to this notice, newest first
File Type Posted
I- IVD OTHER THAN FULL AND OPEN COMPETITION FOR AN ACQUISITION UNDER THE SIMPLIFIED ACQUISITION THRESHOLD_ 22.pdf PDF

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity